• 제목/요약/키워드: air circulation

검색결과 545건 처리시간 0.024초

대기오염관리의 새로운 접근방법 (New Approach to Air Quality Management)

  • 윤명조
    • 환경위생공학
    • /
    • 제8권2호
    • /
    • pp.25-48
    • /
    • 1993
  • International concern over the environmental pollution is ever increasing, and diversified countermeasures must be devised in Korea also. Global trend, damages, problems and countermeasures with respect to issues mentioned in the Rio Declaration, such as prevention of ozone layer destruction, reduction of migratory atmospheric pollution between neighboring countries, and prevention of global greenhouse effect, were discussed in this report. Conclusion of the report is summarized as follows : A. Measurement, Planning and Monitoring (1) Development and implementation of a global network for measurement and monitoring from the global aspects such factors as related to acid rain(Pioneer substances, pH, sulfate, nitrate), effect of global temperature(Air temperature, $CO_2$, $CH_4$, CFC, $N_2O$) and destruction of ozone layer($CFC_S$). (2) Establishment of network system via satellite monitoring movement of regional air mass, damage on the ozone layer and ground temperature distribution. B. Elucidation of Present State (1) Improvement and development of devices for carbon circulation capable of accurately forecasting input and output of carbon. (2) Developmental research on chemical reactions of greenhouse gas in the air. (3) Improvement and development of global circulation model(GCM) C. Impact Assessment Impact assessment on ecosystem, human body, agriculture, floodgate, land use, coastal ecology, industries, etc. D. Preventive Measures and Technology Development (1) Development and consumption of new energy (2) Development of new technology for removal of pioneer substances (3) Development of substitute matter for $CFC_S$ (4) Improvement of agriculture and forestry means to prevent the destruction of ozone layer and the greenhouse effect of the globe (5) Improvement of housing to prevent the destruction of ozone layer and the greenhouse effect of the globe (6) Development of new technology for probing underground water (7) Preservation of forest (8) Biomass 5. Policy Development (1) Development of strategy model (2) Development of long term forecast model (3) Development of penalty charge effect and expense evaluation methods (4) Feasibility study on regulations By establishing the above mentioned measures for environmentally sound and sustainable development to establish the right to live for humankind and to preserve the one and only earth.

  • PDF

태양열과 지열을 이용한 난방용 공기순환시스템 기초연구 - 태양열을 이용한 트롬월식의 축열성능 중심으로 - (A Basic Study on the Air Circulation System for Heating using Solar and Geothermal Heat - Focused on Trombe Wall Thermal Storage Performance using Solar Heat -)

  • 김병윤;최용석
    • 한국농촌건축학회논문집
    • /
    • 제19권4호
    • /
    • pp.49-56
    • /
    • 2017
  • Each country in the world currently concentrates on shifting into clean energy, which can be alternative energy, for global environment protection and solution to the problem of fossil fuel depletion. The Korean government is predicted to develop renewable energy, such as solar power, ground power, and offshore wind power, and to increase their supply ratios by ending the use of coals and nuclear power plants. This study conducted experiments on thermal storage performance of Trombe wall thermal storage materials using solar power and simulations in order to offer baseline data for the development of a hybrid air circulation system for heating that can maximize efficiency by simultaneously using solar and geothermal power. The study results are as follows: (1) In all the specimens with 3m, 5m, and 7m in the length of thermal storage pipe, $5.7^{\circ}C$, $7.8^{\circ}C$, and $10.5^{\circ}C$ rose, respectively, as the thermal storage effect of the specimens attaching insulation film and black tape to the general funnel. They were most excellent in terms of thermal storage effect. (2) As a result of thermal performance evaluation on the II type specimens, II-3 ($7.8^{\circ}C$ rise) > II-4 ($5.3^{\circ}C$ rise) > II-1 ($3.9^{\circ}C$ rise) > II-2 ($2.3^{\circ}C$ rise) was revealed, and thus II-3 (insulation film + black tape) was most effective as shown in the I type. (3) This study analyzed air current and temperature distribution inside of the greenhouse by linking actually measured values and simulation interpretation results through the interpretation of CFD (computational fluid dynamics). As a result, the parts absorbing heat and discharging heat around the thermal storage pipe could be visibly classified, and temperature distribution inside of the greenhouse around the thermal storage pipe could be figured out.

에너지플러스 시뮬레이션을 통한 하천수 열원 히트펌프 시스템의 적용 가능성 분석 (An Applicability Analysis of River Water Source Heat Pump System using EnergyPlus Simulation)

  • 손병후
    • 한국지열·수열에너지학회논문집
    • /
    • 제18권2호
    • /
    • pp.10-21
    • /
    • 2022
  • A water source heat pump (WSHP) system is regarded as an energy-efficiency heating and cooling supply system for buildings due to its high energy efficiency and low greenhouse gas emissions. Recently, water sources such as river water, lake water, and raw water are attracting attention as heat sources for a heat pump system in Korea. This paper analyzed the applicability of a river water source heat pump system (RSHP). The river water temperature level was compared with the outdoor air and ground temperature levels to present applicability. In addition, the cooling and heating performance were compared through a simulation approach for the RSHP and a ground source heat pump (GSHP) applied to a large-scale office building. To compare the temperature level, the actual data were applied to the river water and the outdoor air, while the simulation results were applied to the ground circulation water. The results showed that the change in river water temperature throughout the year was similar to the change in outdoor air temperature. However, unlike the outdoor air temperature, the difference between the hourly and daily average river water temperatures was not large. The temperature level of river water was lower during the heating season and somewhat higher during the cooling season than that of the ground circulation water. Finally, the performance of the RSHP system was 13.4% lower than that of the GSHP system on an annual-based.

연안 지역 고농도 PM2.5 사례에 대한 국지 규모 공기괴 재순환 지수 적용 연구 (A Study on the Application of Local-scale Air Mass Recirculation Factor to High-concentration PM2.5 Episode in Coastal Areas)

  • 유정우;김지선;김은지;이순환
    • 한국환경과학회지
    • /
    • 제32권8호
    • /
    • pp.521-531
    • /
    • 2023
  • This study analyzed the impact of recirculation on high-concentration PM2.5 in the coastal area. Through the analysis of observational data, it was observed that the development of sea breeze led to an increase in PM2.5 and SO42- concentrations. Hysplit backward trajectory analysis confirmed the occurrence of air mass recirculation. Results from WRF and CMAQ numerical simulations indicated that pollutants transported from land to sea during the night were re-transported to the land by daytime sea breeze, leading to high-concentration PM2.5 in Busan. To quantitatively investigate the recirculation a recirculation factor (RF) was calculated, showing an increase in RF values during high-concentration PM2.5 episodes. However, the RF values varied slightly depending on the time resolution of meteorological data used for the calculations. This variation was attributed to the terrain characteristics at observation sites. Additionally, during long-range transported days leading to nationwide high-concentration PM2.5 events, synoptic-scale circulation dominated, resulting in weaker correlation between PM2.5 concentration and RF values. This study enhances the understanding of the influence of recirculation on air pollution. However, it is important to consider the impact of temporal resolution and terrain characteristics when using RF for evaluating recirculation during episodes of air pollution.

복잡지형에서 도시화에 따른 대기오염 확산에 관한 시뮬레이션 (Random Walk Simulation of Atmospheric Dispersion on Surface Urbanization over Complex Terrain)

  • 이순환;이화운;김유근
    • 한국대기환경학회지
    • /
    • 제18권2호
    • /
    • pp.67-83
    • /
    • 2002
  • The coupled model (SMART) of dynamic meteorology model and particle dispersion model was developed. The numerical experiment on the relationship between change of land use and diffusion behavior in complex terrain was carried out using this model. It tried to investigate the change of particle diffusion behavior and local weather under the condition in which land-land breeze and sea breeze and mountain breeze intermingled. The numerical experiment results are as follows; 1) The more complicated local circulation field of the interaction of sea breeze, mountain breeze and Land -land breeze is formed. Then, the region circulation in which the urbanization is specific by location of the region is strengthened and is weakened. 2) Though in the region with dominant sea breeze, Land-land breeze does not appear directly, the progress of the sea wind to the inland is affected. 3) In the prediction of the air diffusion, emission high quality and accurate information of the emission site are important. That is to say, the dispersion predicting result which emission high quality and small error of the site perfectly vary for Land - land breeze in the effect may be brought about.

이산화탄소 하이드레이트 슬러리의 생성 및 수송기술개발 (Development of Formation and Transportation Techniques for CO2-Hydrate Slurry)

  • ;윤린
    • 설비공학논문집
    • /
    • 제29권7호
    • /
    • pp.341-349
    • /
    • 2017
  • Formation and transportation of $CO_2$-hydrate slurry was conducted by circulating saturated water with $CO_2$ through a double-tube type heat exchanger which was cooled down by brine. The inner diameter and circulation length of the heat exchanger were 1 inch and 20 m, respectively. Water in tank was supersaturated by injected $CO_2$ and the operation pressure was maintained at 3,000 to 4,000 kPa with fluid-temperature of less than $9^{\circ}C$. $CO_2$ hydrate mass fraction was calculated based on density of $CO_2$-hydrate slurry mixture. Results showed that the $CO_2$-hydrate slurry could be circulated without blockage for 1 hr. Circulation status of the $CO_2$-hydrate slurry was also visualized.

대향류 반응 및 비반응 유동장에서의 단일 와동의 동적 거동 (Dynamic Behaviors of a Single Vortex in Counter Non-reacting and Reacting Flow Field)

  • 유병훈;오창보;황철홍;이창언
    • 대한기계학회논문집B
    • /
    • 제27권9호
    • /
    • pp.1262-1272
    • /
    • 2003
  • A two-dimensional direct numerical simulation is performed to investigate the dynamic behaviors of a single vortex in counter reacting and non-reacting flow field. A predictor-corrector-type numerical scheme with a low Mach number approximation is used in this simulation. A 16-step augmented reduced mechanism is adopted to treat the chemical reaction. The budget of the vorticity transport equation is examined to reveal a mechanism leading to the formation, destruction and transport of a single vortex according to the direction of vortex generation in reacting and non-reacting flows. The results show that air-side vortex has more larger strength than that of fuel-side vortex in both non-reacting and reacting flows. In reacting flow, the vortex is more dissipated than that in non-reacting flow as the vortex approach the flame. The total circulation in reacting flow, however, is larger than that in non-reacting flow because the convection transport of vorticity becomes much large by the increased velocity near the flame region. It is also found that the stretching and the convection terms mainly generate vorticity in non-reacting and reacting flows. The baroclinic torque term generates vorticity, while the viscous and the volumetric expansion terms attenuate vorticity in reacting flow. Furthermore, the contribution of volumetric expansion term on total circulation for air-side vortex is much larger than that of fuel-side vortex. It is also estimated that the difference of total circulation near stagnation plane according to the direction of vortex generation mainly attributes to the convection term.

바람통로 예측모델링을 통한 바람통로 계획전략 - 성남판교 신도시 개발지구를 중심으로 - (Air Corridor Planning Strategy based on the Wind Field and Air Corridor Simulation - A Case Study of Pan-Gyo New Town Development Area -)

  • 황기현;송영배
    • 한국조경학회지
    • /
    • 제31권5호
    • /
    • pp.43-57
    • /
    • 2003
  • This paper presents the air corridor planning strategy based on simulation with MUKLMO_3 (Micro-scale Urban Climate Model) to investigate the wind field and air corridor caused by the land-use change of the New Town Development Area in Pan-Gyo. In the first part, the most frequently observed wind field in the New Town Development Area was measured and used as an initial value to simulate a more realistic wind field and air corridor. Several experiments with different initial values of wind fields were carried out to investigate the wind field change affected by the New Town Development. The results show the features of the wind field of the neutral stability condition in the urban canopy layer with a high resolution near the ground. The wind speed is weakened at this level due to the New Town Development. It was found that the wind field and air corridor are influenced by the land-use change. After the development of the New Town, the speed of the wind field decreased and the main wind directions and air corridor changed. In this study, this model is found to be a useful tool for evaluating air corridor and change of wind field in speed and direction.

실내 기류의 수치해석 (Numerical method for Thermal Convection of air in Ondol Room)

  • 민만기;김주균
    • 대한설비공학회지:설비저널
    • /
    • 제7권1호
    • /
    • pp.4-12
    • /
    • 1978
  • At Grashof numbers $10^{10},\;5{\times}10^{10}$, and $10^{11}$ nonlinear partial differential equations for two dimensional thermal circulation of air in a rectangular enclosure heated from below are solved numerically by finite difference explicit methood in time-dependent form. Two vertical walls and ceiling are held at low temperature and floor at high temperture. Results are compared with From's numerical solutions at $10^9{\lesssim}\;N_{Gr}\;<10^{13}$. The effective draft temperature fields are also obtained to examine cold draft problem, there included a line of constant effective draft temperature $-1.667^{\circ}C$ which is essentially Houghten's $80\%$ comfort data.

  • PDF

공기청정 시스템 성능예측을 위한 실내 유동현상에 관한 수치모사 (Numerical Simulation of Flows inside the Various Rooms for Performance Assessment of Air Cleaning System)

  • 손덕영;이두환;길재흥;최윤호;김동현
    • 에너지공학
    • /
    • 제11권4호
    • /
    • pp.306-316
    • /
    • 2002
  • 본 연구에서는 공기청정기의 최적설계에 필요한 자료를 획득하기 위해 다양한 실내공간에서의 유동에 대한 연구를 수치해석적인 방법으로 수행하였다. 실내유동 해석을 위해서 사용된 공기청정기의 사용처로는 물류창고, 아파트 거실과 주방, 6인 병실을 선정하여 계산을 수행하였다 시간에 따른 평균농도 변화는 모든 실내공간에서 완전 혼합(perfect mixing)인 경우와 매우 흡사하게 나타나는 것을 볼 수 있었고, 공기청정기의 설치 위치가 시간에 따른 실내의 평균농도 변화에 미치는 영향은 미미한 것을 볼 수 있었다. 실내의 국부적인 농도를 살펴보면 사용처 별로 유동의 흐름이 원활하지 못해서 생기는 공기정화 취약구 역을 관찰할 수 있었으며, 이는 각 공간모델과 공기청정기의 설치위치에 따라 크게 달라지는 것을 볼 수 있었다.