• Title/Summary/Keyword: air and air-gel type

Search Result 35, Processing Time 0.029 seconds

A Study on the Heat Release Characteristics of Gel Type Micro Size Latent Heat Storage Material Slurry with Direct Contact Heat Exchange Method (겔 상태의 미세 잠열 축열재 혼합수의 기액직접접촉식 열교환법에 의한 방열 특성)

  • 김명준
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.4
    • /
    • pp.618-623
    • /
    • 2004
  • This paper has dealt with the heat storage characteristics of gel type micro size latent heat storage material slurry. The heat release operation to the gel type micro size latent heat storage material slurry was carried out using hot air bubbles by direct contact heat exchange. This experiment was carried out using phase change material of n-paraffin so the heat release amount is higher than cold water system. The parameters of this experiment were concentration of latent heat phase change material, height of heat release bath and inlet velocity of hot air. The main results obtained are as follows : (1) The effect of concentration of latent heat phase change material dispersed with water is very affective to the direct contact heat exchange between hot air and gel type micro size latent heat storage material slurry. (2) It is clarified that the most effective concentration of latent heat phase change material dispersed with water exists around 20mass% at this type of direct heat exchange model experiment.

Measurement of Effective Thermal Conductivity in Silica Gel Packed Bed (실리카겔 충전층에서의 유효열전도율 측정)

  • Kwon Oh-Kyung;Yun Jae-Ho;Kim Joung-Ha
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1126-1133
    • /
    • 2004
  • This paper presents an experimental measurement of effective thermal conductivity in an adsorbent packed bed with silica gel A type. The effective thermal conductivity was measured under different conditions of the adsorbent bed temperature, pressure, particle size and water content by using the transient hot wire method. The measured effective thermal conductivity showed to become bigger with decreasing particle size or increasing water content, but it was a little affected with increasing bed temperature and pressure. The bed temperature was varied in the range of 1$0^{\circ}C$ (equation omitted) T (equation omitted) 5$0^{\circ}C$ and the pressure in the range of 10 kPa (equation omitted) P (equation omitted) 190 kPa. The results show that 0.10~0.18 W/mㆍK of effective thermal conductivity measured for the zero water content.

Injectable Gel Type Formulation of Hydrated Egg Phosphatidylcholine and Hyaluronate for Local Drug Delivery

  • Kim, Sang-Gyun;Chung, Hesson;Lee, In-Hyun;Kang, Seung-Back;Kwon, Ick-Chan;Sung, Ha-Chin;Jeong, Seo-Young
    • Journal of Pharmaceutical Investigation
    • /
    • v.32 no.3
    • /
    • pp.165-172
    • /
    • 2002
  • Injectable gel composed of egg phosphatidylcholine (egg PC), hyaluronate (HA) and water was formulated for local drug delivery. The lamellar liquid crystalline structure of the egg PC/water system did not change by adding HA in the formulation. However, egg PC/HA/water gel was more resistant to erosion than the egg PC/water gel. The egg PC/HA/water and egg PC/water gels containing model drugs, tetracycline and sudan IV were prepared to perform in vitro and in vivo drug release experiments. In vitro release of tetracycline was sustained in the gel type formulations. The release rate of hydrophobic sudan IV was extremely slow. More than 99% of sudan IV remained inside the gel after 5 days. In vivo release of drugs from the air pouch model in Balb/c mice shows that lipophilic sudan IV remained for more than 10 days whereas tetracycline remained for 1 day in the pouch. The compatibility of the gels was also examined by histopathology. The gels did not cause any adverse inflammatory effect in the air pouch.

Experimental Investigation on Small-scale Sorption Refrigerator (소형 흡착식 냉동기에 대한 실험적 연구)

  • 고준석;정상권
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.4
    • /
    • pp.312-317
    • /
    • 2003
  • This paper describes an experimental study on small-scale sorption refrigerator. Silica gel (type A) as an adsorbent, HFC-l34a as a refrigerant were selected for a sorption refrigerator The focus of the design was to reduce the cycle time of the sorption refrigerator. Through the experiment, pressure and temperature variations in the adsorber were measured and the performance of refrigerator was predicted. In this paper, the small-scale sorption refrigerator operates with the cycle time of 4805. Its predicted cooling capacity is 25 W at -15$^{\circ}C$ and COP is 0.23.

Numerical Analysis of the Heat and Mass Transfer in a Fin Tube Type Adsorber (핀튜브형 흡착탑에서 열 및 물질전달 수치해석)

  • Kwon, Oh Kyung;Chung, Jae Dong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.8
    • /
    • pp.457-463
    • /
    • 2013
  • Nowadays, adsorption chillers have been receiving considerable attention, as they are energy saving and environmentally benign systems. A fin tube type heat exchanger in which adsorption/desorption takes place is required with more compact size. The adsorption chiller is expected to have high energy efficiency in utilizing the waste heat exhausted from a process. The objectives of this paper are to scrutinize the effect of design parameters on the adsorption performance, especially the fin pitch of the fin tube, and to develop an optimal design fin tube heat exchanger in a silica gel/water adsorption chiller. From the numerical results, the fin pitch of 2.5 mm shows the highest adsorption rate, compared to other fin pitches, such as 5 mm, 7.5 mm and 10mm. Also, the adsorption rate is affected by the cooling water and hot water temperature.

Simulation of a Polymer-Water Adsorption Refrigerator using Plate-Type Adsorption Heat Exchangers (판형 흡착열교환기를 사용한 폴리머-물 흡착식 냉동기의 성능예측)

  • Kim, Dong-Seon;Lee, Dae-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.2
    • /
    • pp.94-102
    • /
    • 2015
  • A hydroscopic polymer is used as the adsorbent in an adsorption refrigeration system. A pair of plate-type heat exchangers, thinly coated with the polymer, is simulated using a two-dimensional transient model to predict performance of the system. It is predicted that the system would yield 0.57 kW SCP and 0.47 COP at $80^{\circ}C$ heating and $30^{\circ}C$ cooling temperatures. In comparison with a conventional silica gel-water system, the COP is comparable but SCP is about three times larger. The slow mass diffusion rate of the polymer should be improved for better performance.

Aging Effects on Electrical Characteristics of Sol-gel Processed CuO Thin Film Transistors (Aging 효과가 Sol-gel 공정 기반 CuO 박막 트랜지스터의 전기적 특성에 미치는 영향)

  • Jang, Jaewon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.9
    • /
    • pp.527-531
    • /
    • 2016
  • In this study, p-type thin film transistors consisting of CuO channels were fabricated by sol-gel process, with copper (II) acetate monohydrate precursors. At $500^{\circ}C$, the deposited films were fully converted into monoclinic phase CuO. The fabricated CuO thin film transistors deliver field effect mobility in saturation regime of $0.015cm^2/Vs$, and $I_{on}/I_{off}$ of ${\sim}10^3$. The degradation of the performance of the fabricated CuO thin film transistor caused by the exposure to air has been studied.

A Study on the Effectiveness of Hand Sanitizer compared to Conventional Ultrasound Gel during Ultrasound Examination (초음파검사 시 기존 초음파젤과 비교한 손소독제의 유용성 연구)

  • Sun-Youl Seo;Jin-Ok Lee;Young-Ran Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.957-964
    • /
    • 2023
  • This study focused on hand sanitizer as a medium that can replace ultrasonic gel, which is vulnerable to contamination by bacteria that reside on the hand. Hand sanitizer produces a strong sterilization effect from germs resident on the hands through different sterilization principles depending on the ingredients. Select products of gel type, cream type, and foam type, except for liquid type with low viscosity, and ultrasonically apply one 62% ethanol gel type and one cream type, one benzalkonium chloride 0.066% cream type and one foam type, respectively. Using ATS-539 as a medium, image evaluation was performed on the axial and lateral resolution and penetration depth, and the presence or absence of an air layer between the probe and the phantom. As a result, in the evaluation of the axial and lateral resolution and the depth of penetration, all four experimental groups met the evaluation criteria. However, in the case of the foam type, although it was suitable for the evaluation criteria of resolution and penetration depth, dark shadows appeared on both sides except for the center of observation during image evaluation. Through this experiment, it was possible to confirm the possibility that the remaining three types of hand sanitizers except the foam type could replace the ultrasonic gel.

A Numerical Study for the Heat and Mass Transfer in Silica gel/Water Adsorption Chiller's Adsorber (흡착식 냉동기의 흡착탑에서 열 및 물질전달에 관한 수치적 연구)

  • Kwon, Oh-Kyung;Yun, Jae-Ho;Kim, Joung-Ha;Kim, Yong-Chan;Joo, Young-Ju
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.341-346
    • /
    • 2005
  • Nowadays, adsorption chillers have been receiving considerable attentions as they are energy-saving and environmental1y benign systems. A Fin & tube type heat exchanger in which adsorption/desorption take place is required more compact size. The adsorption chiller is expected to have high energy-efficiency in utilizing the waste heat exhausted from a process. The objectives of this paper are to investigate the effect of fin pitch of fin & tube on the adsorption performance and to develop an optimal design fin & tube heat exchanger in the silica gel/water adsorption chiller. Previous study concluded that optimal particle size selected 0.5mm, type HO silica gel, and fundamental heat transfer & mass transfer experiments carried out. From the numerical results, the adsorption rate for the fin pitch 2.5mm is the highest than that for the fin pitch 5mm, 7.5mm and 10mm. Also cooling water & hot water temperature affect the adsorption rate.

  • PDF