• 제목/요약/키워드: ageing test

검색결과 141건 처리시간 0.043초

열수노화 조건에서 레저선박용 탄소섬유강화플라스틱의 강도변화에 관한 실험적 연구 (Experimental Study on the Hygrothermal Ageing Effect to the Strength of CFRP Materials for Marine Leisure Boat)

  • 정한구;노재규
    • 대한조선학회논문집
    • /
    • 제55권3호
    • /
    • pp.205-214
    • /
    • 2018
  • This paper deals with the experimental study on the hygrothermal ageing effect to the strength of Carbon Fiber Reinforced Plastics (CFRP) materials for marine leisure boat manufactured by vacuum assisted resin infusion method. The experiments performed consist of tensile, flexural and shear tests according to American Society for Testing and Materials (ASTM) and Korean Industrial Standards (KS) test methods. Test coupons are varied from uni-directional(UD, $0^{\circ}$, $90^{\circ}$), Bi-Directional (BD), and Double-Bias (DB) carbon fiber fabrics in conjunction with epoxy resin. The results of tensile test show that tensile strength reduces significantly while not the same degree of reduction is observed for elasticity modulus with respect to the existence of hygrothermal ageing effect. This implies that the tensile strain induced from external load holds steady values but ultimate strength values change widely under hygrothermal ageing effect. In case of the flexural test, $0^{\circ}$ UD shows more strength reduction than $90^{\circ}$ UD while BD has reduced values in both flexural strength and elasticity modulus under hygrothermal ageing effect. It is learned that the bending strain induced from external load and ultimate strength values are reduced with respect to hygrothermal ageing effect. Shear test performed only on DB materials, and the results show marginal reduction in ultimate strength and moderate reduction in elasticity modulus. This means that the shear strain varies more than ultimate shear strength with respect to hygrothermal ageing effect. The experiment conducted in this paper clearly demonstrates the differences in material properties of the CFRP for the consideration of hygrothermal ageing effect. Findings obtained from this experimental study can serve as a fundamental input data for the realistic structural responses of marine leisure boat built in CFRP materials.

송전용 자기애자의 열충격 특성 연구 (Study on Thermal Stress of Porcelain Insulator for T/L)

  • 한세원;조한구;최인혁;이동일
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.208-209
    • /
    • 2006
  • This study presents the thermal stress characteristics of TL porcelain insulators(healthy and ageing) by the accelerating thermal mechanical ageing test with forced temperature gradient. The test temperature gradient is $95^{\circ}C(-35{\sim}60^{\circ}C)$, it was focused to high temperature thermal stress as compared with IEC 60575 standard. There was no a discrimination in the case of healthy aluminous porcelain insulators, dissimilarly in crystoballite insulators according to this test method. It was indicated that the long tenn reliability by thermal stress was conformed reasonably through the conventional accelerating ageing test methods.

  • PDF

뇌서지전류와 Ageing에 의한 산화아연형 피뢰기 소자의 미세구조변화 (Change of the Microstructure of ZnO Arrester block by Lightning Surge Current and Ageing test)

  • 이복희;강성만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1877-1879
    • /
    • 2000
  • This paper deals with the change of the micro-structure of ZnO associated with lightning surge current and ageing test. In this work, a surge current generator which can produce 8/20 [${\mu}s$], 6 [kA] impulse current is designed and fabricated to simulate the lightning impulse current. The residual voltage and leakage current flowing to ZnO blocks are observed. Also a compensation circuit was used in resistive current measurement. The micro-structures of ZnO arrester block were significantly changed by lightning surge current and accelerated temperature ageing test.

  • PDF

The Effect of Ageing Time and Temperature on the Strain Ageing Behaviour of Quenched Zircaloy-4

  • Rheem, Karp-Soon;Park, Won-Koo;Yook, Chong-Chul
    • Nuclear Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.117-123
    • /
    • 1977
  • 소입된 질칼로이-4의 가공시효(strain ageing) 현상에 미치는 시효시간 및 온도의 효과를 523-588 狂 온도 구간에서 1~52초의 짧은 시효기간에 조사하였다. 이 실험 조건하에서, 가공시효응력은 5.55$\times$$10^{-4}$ sec$^{-1}$ 신연속도(strain rate) 경우 시효시간 및 시효온도가 증가할수록 증가하였다. 소입된 질칼로이-4의 응력부하 하의 가공시효 현상이 두 한계로 나타나는 것이 확인되었는데 첫단계는 0.39ev의 활성화 에너지 값의 구간으로 이는 전위 (dislocation) 주위의 응력상태로 인한 침입형 산소원자들의 Snoek타입의 배열 (ordering)로 인한 것으로 고려되었으며 두번째 단계는 0.6ev 활성화에너지 값을 갖는 구간으로 이는 주로 산소원자들의 장범위확산에 기인하는 것으로 해석되었다.

  • PDF

Recovery Voltage Measurements of Oil-immersed Transformer

  • Li, Ming-Hua;Dong, Ming;Qu, Yan-Ming;Yan, Zhang
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권5호
    • /
    • pp.230-234
    • /
    • 2006
  • One of the methods currently being investigated as a possible non-intrusive diagnostic tool for condition monitoring of power transformer and cable is the recovery voltage measurement, which will be improving the ability to detect the content of water concentration and the ageing process in the insulation system and may thus be an indicator of insulation quality and its ageing status. The polarization phenomenon was studied using RVM with oil-paper samples. In order to interpret its mechanism, the Extended Debye model was introduced. With different circuit parameters, various simulation results were gotten. Furthermore, with the test samples of different ageing condition, measurements are accomplished in the lab. On the basis of this experiment as well as theoretical analysis, correlations between polarizations and ageing were analyzed.

Study of the ageing of hollow fibers in an industrial module for drinking water production

  • Wang, S.;Wyart, Y.;Perot, J.;Nauleau, F.;Moulin, P.
    • Membrane and Water Treatment
    • /
    • 제4권1호
    • /
    • pp.53-67
    • /
    • 2013
  • In this study, ageing characteristics of an industrial hollow-fiber membrane module were investigated after 50 months of drinking water production. For this purpose, the industrial module was opened to make 18 smaller modules with hollow-fibers taken from different parts of the industrial module. These modules were probed by the use of a magnetic nanoparticle (NP) challenge test based on magnetic susceptibility (K) measurement of permeate. No magnetic susceptibility was detected in permeate when the challenge test was performed on an intact membrane module, indicating the complete retention of nanoparticles by the membrane. The compromised membrane module can be successfully detected by means of magnetic susceptibility measurement in permeate. So, this study clearly demonstrates that ageing of ultrafiltration membranes can be monitored by measuring the magnetic susceptibility of permeate from an ultrafiltration membrane module. These results showed that the hollow fibers in the center zones of the bundle would age faster than those in the outer zones around the bundle. This result is in agreement with numerical simulation (Daurelle et al. 2011).

직류 평활용 전해 커패시터 노화 평가 (Ageing evaluation of electrolytic capacitor for dc-link)

  • 이성희;이진희;이치환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.634_635
    • /
    • 2009
  • Large aluminium electrolytic capacitors are widely used in inverter systems for smoothing dc-link voltage. If capacitors in dc-link are deteriorated by ageing, dc-link voltage is fluctuated by lessened capacitance and their bodies are heated by raised ESR(equivalent serial resistance) and finally system faults can be occurred. In this paper, on-load ageing test method of electrolytic capacitor in inverter system is proposed and test results are shown.

  • PDF

발변전급 피뢰기용 산화아연소자의 AC 가속열화특성 (AC Accelerated Ageing Characteristics of Zinc Oxide Varistors for the Station Class Lightning Surge Arresters)

  • 조한구;윤한수;김석수;한동희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.315-316
    • /
    • 2005
  • This paper describes the AC accelerated ageing characteristics of zinc oxide varistors for the station class lightning surge arresters. ZnO varistors whose rated voltage were 3.27kV, 4.00kV, and 6.00kV were manufactured with general ceramic production methods. The power loss of sample A varistors rapidly increased and eventually showing the thermal run-away, but sample B and sample C varistors exhibited negative creep phenomena in power losses during the test.

  • PDF

RTV 실리콘 코팅재의 코로나 방전 열화 특성 (A Study on Ageing Characteristics of RTV Silicone Coating Materials by Corona Discharge)

  • 한세원;한동희;조한구
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권8호
    • /
    • pp.359-364
    • /
    • 2003
  • Ageing characteristics of RTV coating materials by corona discharge have been studied. The hydrophobicity recovery of RTV coating materials with 300${\mu}{\textrm}{m}$ thickness was identical with a bulk silicone materials. The RTV coating materials hydrophobicity has been almost lost when its were discharged during 40 seconds by corona discharge of 10㎸, and recovered after about 45 hours. The resistivity of RTV coating materials has not been recovered after 45 hours, though after 80 hours the initiation resistivity value has been recovered up to 95%. There was no critical change of compounds(such as Si and Al) on RTV surfaces by the corona discharge treatment until 100 seconds. In the test of arc erosion, it was seen that the coating sample with silicone rubber as a base material have more longer burn-out time than other samples with FRP or glass base.

The Influence of Successful Ageing Indicators on Life Satisfaction among Elders in Korea

  • Chang, Jin-Kyung;Han, Eun-Joo;Won, So-Yean
    • International Journal of Human Ecology
    • /
    • 제10권2호
    • /
    • pp.25-37
    • /
    • 2009
  • This study investigated differences in related factors affecting life satisfaction with the elderly in or above middle class experiencing successful ageing. In the study, the respondents were 206 elderly people whose occupation (professional career) placed them in the middle and upper class range residing in metropolitan Seoul. Major results are summarized as follows: (1) In order to test gender differences, results of t-test show that there are 13 variables with seven of those being statistically significant and the rest being insignificant. (2) Needs fulfillment and physical functioning are significant factors for Korean male elders to be satisfied with their later lives. Needs fulfillment, physical functioning, group activity, and learning activity are significant factors for Korean female elders to be satisfied with their later lives.