Browse > Article
http://dx.doi.org/10.12989/mwt.2013.4.1.053

Study of the ageing of hollow fibers in an industrial module for drinking water production  

Wang, S. (Aix Marseille Universite, Laboratoire de Mecanique, Modelisation et Procedes Propres (M2P2 - UMR-CNRS 7340))
Wyart, Y. (Aix Marseille Universite, Laboratoire de Mecanique, Modelisation et Procedes Propres (M2P2 - UMR-CNRS 7340))
Perot, J. (SAUR)
Nauleau, F. (SAUR)
Moulin, P. (Aix Marseille Universite, Laboratoire de Mecanique, Modelisation et Procedes Propres (M2P2 - UMR-CNRS 7340))
Publication Information
Membrane and Water Treatment / v.4, no.1, 2013 , pp. 53-67 More about this Journal
Abstract
In this study, ageing characteristics of an industrial hollow-fiber membrane module were investigated after 50 months of drinking water production. For this purpose, the industrial module was opened to make 18 smaller modules with hollow-fibers taken from different parts of the industrial module. These modules were probed by the use of a magnetic nanoparticle (NP) challenge test based on magnetic susceptibility (K) measurement of permeate. No magnetic susceptibility was detected in permeate when the challenge test was performed on an intact membrane module, indicating the complete retention of nanoparticles by the membrane. The compromised membrane module can be successfully detected by means of magnetic susceptibility measurement in permeate. So, this study clearly demonstrates that ageing of ultrafiltration membranes can be monitored by measuring the magnetic susceptibility of permeate from an ultrafiltration membrane module. These results showed that the hollow fibers in the center zones of the bundle would age faster than those in the outer zones around the bundle. This result is in agreement with numerical simulation (Daurelle et al. 2011).
Keywords
drinking water; ageing characteristics; magnetic nanoparticles; magnetic susceptibility;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Choi, S., Yang, J. Suh, C. and Cho, J. (2011), "Use of fluorescent silica particles for checking the integrity of microfiltration membranes", J. Membrane Sci., 367(1-2), 306-313.   DOI   ScienceOn
2 DiLeo, A. and Phillips, M. (1995), "Process for evaluating solute retention characteristics of membranes", US Pate As for the previously used modules, the same observations and the same conclusions can be made regarding the evolution of the magnetic susceptibility in the feed (presence of PAC). nt 5,457,986.
3 Daurelle, J.V., Q. Derekx, Y. Wyart, K. Glucina and P. Moulin (2011), Use of advanced CFD tool to characterize hydrodynamic of commercial UF membrane module, 8th IWA Leading Edge Amsterdam, Netherland, 8-10 Juin
4 Fauconnier, N., Pons, J.N. Roger, J. and Bee, A. (1997), "Thiolation of maghemite nanoparticles by dimercaptosuccinic acid", J. Colloid Inter. Sci., 194(2), 427-433.   DOI   ScienceOn
5 Giglia, S. and Krishnan, M. (2008), "High sensitivity binary gas integrity test for membrane filters", J. of Membrane Sci., 323(1), 60-66.   DOI   ScienceOn
6 Guo, H., Wyart, Y. Perot, J. Nauleau, F. and Moulin, P. (2010), "Application of magnetic nanoparticles for ultrafiltration membrane integrity monitoring at low-pressure operation", J. of Membrane Sci., 350(1-2), 172-179.   DOI   ScienceOn
7 Guo, H., Wyart, Y. Perot, J. Nauleau, F. and Moulin, P. (2010), "Low-pressure membrane integrity tests for drinking water treatment: A review", Water Res., 44(1), 41-57.   DOI   ScienceOn
8 La, J.M., Glucina, K. Chamant, M. and Simonie, P. (1998), "Acoustic sensor: a novel technique for low pressure membrane integrity monitoring", Desalination, 119(1-3), 73-77.   DOI   ScienceOn
9 Moulin, P. (2008) Patent Number(s): FR2901607-A1; EP1862791-A2.
10 Suh, C., Choi, B. Lee, S. Kim, D. and Cho, J. (2011), "Application of genetic programming to develop the model for estimating membrane damage in the membrane integrity test using fluorescent nanoparticle", Desalination, 281(17), 80-87.   DOI   ScienceOn
11 Phattaranawik, J., Fane, A.G. and Wong, F.S. (2008), "Novel membrane-based sensor for online membrane integrity monitoring", J. Membrane Sci., 323(1), 113-124.   DOI   ScienceOn
12 Walsh, M.E., Chaulk, M.P. and Gagnon, G.A. (2005), "Indirect integrity testing on a pilot-scale ultrafiltration membrane", J. Water Supply: Research and Technology., AQUA 54, 105-114.