• 제목/요약/키워드: ageing temperature

검색결과 111건 처리시간 0.027초

액체질소에서의 극저온 절연매질의 Warm-up/Cool-down 특성 (Warm-up and Cool-down Characteristics of Cryogenic Insulation Materials in Liquid Nitrogen)

  • 이상화;신우주;;오석호;성재규;이방욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.119-119
    • /
    • 2010
  • Among the various factors influencing the service life of the electric equipment, the performance of dielectric insulation materials has an important role to determine their whole service life. In order to determine the degradation of insulating materials immersed in extremely low temperature media such as liquid nitrogen, the abrupt temperature change from cryogenic to normal room temperature should be considered. But the assessments of low-temperature aging test method for the dielectric materials immersed in liquid nitrogen considering these conditions were not fully reported. Therefore, for the fundamental step to establish the suitable degradation test methods for cryogenic dielectric materials, we focused on the evaluation of ageing test methods for dielectric materials exposed to low temperature environments considering thermal shock by cool-down and warm up test.

  • PDF

생체 환경 정보 센싱 모듈 및 농장 제어 게이트웨이를 이용한 스마트 낙농 관리 시스템 개발 (Smart Dairy Management System Development Using Biometric/Environmental Sensors and Farm Control Gateway)

  • 박용주;문준
    • 대한임베디드공학회논문지
    • /
    • 제11권1호
    • /
    • pp.15-20
    • /
    • 2016
  • Recently, the u-IT applications for plants and livestock become larger and control of livestock farm environment has been used important in the field of industry. We implemented wireless sensor networks and farm environment automatic control system for applying to the breeding barn environment by calculating the THI index. First, we gathered environmental information like livestock object temperature, heart rate and momentum. And we also collected the farm environment data including temperature, humidity and illuminance for calculating the THI index. Then we provide accurate control action roof open and electric fan in of intelligent farm to keep the best state automatically by using collected data. We believed this technology can improve industrial competitiveness through the u-IT based smart integrated management system introduction for industry aversion and dairy industries labor shortages due to hard work and old ageing.

구형 가돌리늄화합물 입자 제조 (Preparation of Spherical Gadolinium Compound Particles)

  • 김응호;최청송;정경채;박진호;장인순
    • 한국세라믹학회지
    • /
    • 제30권7호
    • /
    • pp.563-570
    • /
    • 1993
  • Spherical, monosized gadolinium compound was prepared by the reaction of Gd(NO3)3 solution with decomposition products of urea in the solution at evaluated temperature. Chemical composition and calcination characteristics of spherical gadolinium compound prepared were investigated by X-ray IR and TG-DTA. The approximate chemical composition of the spherical particle precipitated was Gd(OH)CO3.1.5H2O. Gd(OH)CO3.1.5H2O was calcined to monoclinic type Gd2O3 at 115$0^{\circ}C$ via cubic type Gd2O3 near $600^{\circ}C$. The effects of various parameters such as pH, temperature, concentration ratio of urea to gadolinium precusor, ageing time, and others material (CCl3COOH and HOCNH2) in stead of urea as precipitating agent on the properties of the resulting precipitates were studied systematically.

  • PDF

H종 주상용 몰드 변압기의 덕크구조에 따른 열해석 특성 (Surface Ageing Property of Polymer Insulator for Transmission line with Forest Fire Test)

  • 조한구;김광용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.111-111
    • /
    • 2010
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss, but it needs some cooling method because heat radiation between each winding is difficult. In this paper, the temperature distribution and thermal stress analysis of H class 100kVA pole cast resin transformer for power distribution are investigated by FEM program.

  • PDF

열처리효과에 따른 저밀도 폴리에틸렌 박막의 유전특성 (The Dielectric Characteristics of Low Density Polyethylene Film due to Thermal Treatment Effect)

  • 김왕곤;가출현;이용우;홍진웅
    • 한국안전학회지
    • /
    • 제11권1호
    • /
    • pp.67-74
    • /
    • 1996
  • In order to investigate the effect and reliability coming up to properties of the matter due to the change of solid structure in dielectrics, the effect of dielectric characteristics for thermal treated LDPE film was made researches. Specimens of LDPE with thickness 100 [$\mu\textrm{m}$] were investigated into the change of solid structure by ageing. Thermal treated specimen were made, that were after applying heat at 100 [$^{\circ}C$] for 1 [hour] \circled1 air-cooled specimen slowly, \circled2 water-cooled specimen under the ,com temperature, \circled3 liquid nitrogen gas-cooled specimen rapidly. With specimen of thermal treated three types turn out and original, it was for dielectric characteristics to be experimented in the temperature range of 20~120 [$^{\circ}C$], frequency range of 30~1.5${\times}10^5/$[Hz], appling voltage from 300 to 1500[㎷]. Consequently, the degree of crystallinity was changed with 49~57 [%] according to the thermal treatment. In case of frequency, 100 [Hz], on the thermal dependance in dielectric characteristics, tan decreases due to cooling method.

  • PDF

HTV 실리콘 고무에서 열화인자에 따른 저분자량 성분과 표면 발수성의 변화 (Effects of Ageing Factors on Low Molecular Weight Silicone Fluids Content Fluids Content and Surface Hydrophobicity in HTV Silicone Rubber)

  • 허창수;연복희;조한구
    • 한국전기전자재료학회논문지
    • /
    • 제12권1호
    • /
    • pp.1-10
    • /
    • 1999
  • In this paper, we have investigated the effects of the environmental factors on Low Molecular Weight (LMW) silicone fluid contents existing in high temperature vulcanized (HTV) silicone rubber sample, using dipping method and contact angle, current measurement. Artificial treatments such as immersion in water, elevated temperature, UV irradiation and dry band arcing under salt-fog condition are selected as the environmental factors. This results will be helpful to investigate the degradation with time and to expect a life time, because the LMW silicone content, which is important to recovery the hydrophobicity of silicone rubber surface, show different results by each environmental factors.

  • PDF

알루미늄합금의 열간 액압성형법 성형성에 대한 가열조건의 영향도 분석 (The Effect of the Heating Conditions on the Warm Hydro-Formability of the Alumium Alloys)

  • 김봉준;박광수;류종수;손성만;문영훈
    • 열처리공학회지
    • /
    • 제18권3호
    • /
    • pp.172-176
    • /
    • 2005
  • Modern automobiles are built with a steadily increasing variety of materials and semifinished products. The traditional composition of steel sheet and cast iron is being replaced with other materials such as aluminum and magnesium. But low formability of these materials has prevented the application of the automotive components. The formability can be enhanced by conducting the warm hydroforming using induction heating device which can raise the temperature of the specimen very quickly. The specimen applied to the test is A6061, A7075 extruded tubes which belong to the age-hardenable aluminum alloys. But in the case of A6061 age hardening occurs at room temperature or at elevated temperatures before and after the forming process. In this study the effects of the heating condition such as heating time, preset temperature, holding time during die closing and forming time on the hydroformability are analyzed to evaluate the phenomena such as dynamic strain hardening and ageing hardening at high temperatures after the hydroforming process.

소형 변압기 안전성 실태 분석 및 고찰 (The Safety Survey Analysis and Consideration of Small Transformer)

  • 김성삼
    • 한국안전학회지
    • /
    • 제29권2호
    • /
    • pp.1-6
    • /
    • 2014
  • In this paper, safety certification products and safety condition of small transformer is analyzed in industries field and educational facilities. In transformer of 50places, absolute majority is step down transformer to measure of instrument. Most transformers were below 5kVA and 1~3kVA capacity was the mainstream. In industries field, 5 transformers were found without safety certification according to the Electrical Appliances Safety Control Act as cheap product prefer and lack of safety consciousness. Mark & number, voltage, date of manufacture of safety certification must show item of certification. However date of manufacture showed in product of 18%, 9places. As result of thermal imaging camera, running temperature of transformer was showed in below of target temperature. However as a narrow space of transformer and wall, power cable was touched on a ventilating flue in transformer. It was simple carelessness case that surface fouling and temperature ageing of transformer accelerate. Power poor connection, neglect of transformer in production equipment, fall damage by setup incongruity and ground omission were found in case of illogicality item of transformer.

휘도비 측정을 통한 유도등의 경년변화 연구 (A Study on the Aging Change of Exit Light by Measuring the Ratio of Luminance)

  • 정종진
    • 한국화재소방학회논문지
    • /
    • 제33권6호
    • /
    • pp.181-185
    • /
    • 2019
  • 본 연구에서는 유도등의 광원과 경년변화에 따른 휘도성능을 분석하기 위하여 사무실, 상가, 병원, 공장 등에 설치된 유도등을 발취하여 CCFL, LED광원별 경년변화에 따른 휘도성능을 분석하였다. 이는 유도등과 같은 전기적 특성을 갖는 소방제품은 설치된 곳의 주위온도나 습도, 먼지 등이 그 성능에 변화를 줄 수 있기 때문에 설치장소별로 발취하여 그 특성을 분석하였다. 실험결과, CCFL유도등은 대형, 중형, 소형 모두 '휘도비 2'정도의 값을 나타내었다. 기술기준 규정값이 '휘도비 9이하'인 점을 감안할 때 매우 양호한 값을 나타냈으며, 경년변화에 의한 휘도비 변화도 거의 없음을 확인할 수 있었다. LED유도등은 '휘도비 5'정도의 값을 나타냈으며, 이는 표시면의 빛이 균일하지 못함을 뜻한다. 또한 경년변화에 의한 휘도비 변화는 거의 없으나, 휘도비의 값은 LED유도등보다 크게 나타났다. 이는 시각적인 측면에서는 만족스럽지 못한 결과이다. 이를 개선하기 위해서는 LED광원의 빛 분산이 필요하며 휘도비 관련 규정을 강화할 필요가 있다.

Stress Relaxation Behavior of Cold-worked and Annealed Zircaloy-4 Tubing

  • Rheem, K.S.;Choi, C.B.;Park, W.K.
    • Nuclear Engineering and Technology
    • /
    • 제8권4호
    • /
    • pp.203-207
    • /
    • 1976
  • 질칼로이-4에 있어서 flow stress strain rate 의존성을 냉간가공 및 소둔된 시편에 대해 20$0^{\circ}C$-45$0^{\circ}C$ 온도 구간에서 응력이완 실험으로 조사하였다. 전체 실험온도에서 In-3-ln i 관계식은 $10^{-5}$-$10^{-3}$ sec$^{-1}$ strain rate의 구간에 걸쳐 선형관계를 보였다. 냉간 가공된 질칼로이 -4의 strain rate sensitivity, m값은 30$0^{\circ}C$에서 최소값을 보인 반면, 소둔된 시편의 경우 30$0^{\circ}C$와 45$0^{\circ}C$에서 최소값들을 보였다. 최소값의 m이 나타나는 온도는 가공시효값이 극대값을 보이는 온도와 일치한다는 사실이 확인되었다. m값의 감소는 활동자유전위들이 산소원자에 의해 pinning된 결과로 유발되는 가공 시효와 관련된 것으로 고려된다. 그리고 소둔된 시편이 45$0^{\circ}C$에서 가지는 최소 m값은 철 원자들로 인한 가공 시효에서 기인된 것으로 생각된다.

  • PDF