• Title/Summary/Keyword: aged material

Search Result 547, Processing Time 0.023 seconds

A Study on the Estimation of the Number of the Household for the Elderly Living Alone and Living with Spouse Only - Cases in Gyeongsangbuk-Do - (고령1인 및 고령부부가구수의 예측에 관한 연구 - 경상북도를 중심으로 -)

  • Bae, Jeong-In
    • Journal of the Korean housing association
    • /
    • v.19 no.2
    • /
    • pp.31-42
    • /
    • 2008
  • Research outcome shows the following: 1. Estimation by the year 2015 on the number of the aged people and on the number of the household of living alone and living with spouse only, per age-cohort by 5 years, per basic self-govern-ins local groups and the city of Daegu. The result is supposed to serve as meaningful basic material in building up future policies in many areas for the aged people living in their homes. 2. Estimation varies according to the areas and the age-cohorts. In urban areas, increase of the numbers of the households of the aged people living alone and living with spouse only is estimated in every age-cohort. In rural areas, variance between two age-groups, old-old and young-old, is observed. Both of the numbers of the households for the aged living alone and the aged living with spouse only have increased continuously by the year 2005. But the hither-to increase tendency is estimated to reverse itself to a decrease starting from the younger within the young-old age group, and the ratio of the old-old age-group in rural population will sharply increase starting from the year 2005. Such increase in the number of the aged people in need of the housing and the social support requires the increasing policy consideration for the issue of housing for the aged living in their homes. In spite of the decreasing tendency in the number of the aged people living alone and living with spouse only in rural areas, still there will continue to be more number of such households than in urban area for the time being. The government of Gyeongsangbuk-Do should pay more consideration to the old-old aged living alone and living with spouse only in rural areas, while being prepared for the sharply increasing households for the aged living alone and living with spouse only in urban areas.

Analysis and Suggestion of Environment-friendly Interior Finishing Materials for Aged Apartment Remodeling (노후 공동주택 리모델링의 친환경 실내 마감재료 분석 및 제안)

  • Kim, Ki-Hyun;Kim, Kyung-Rai
    • Korean Journal of Construction Engineering and Management
    • /
    • v.8 no.2
    • /
    • pp.118-126
    • /
    • 2007
  • Environmentally Sound and Sustainable Development (ESSD)" is a key word in recent years. The construction industry, have put a great influence on ergonomic and sustainable environment. Recently, "green building certifications", such as Indoor Air Quality (IAQ) and eco-friendly material regulation have been established. With this regard, new construction and aged-housing remodeling projects are required to meet these certification criteria. Apartment residents have great concern on eco-product, since many cases are reported that Sick Building Syndrome is caused by toxic substance from building materials. Aged-housing remodeling construction has a unique characteristic in that the residents are already determined prior to construction execution. Therefore, the analysis of resident's need for building materials in aged-housing remodeling is relatively easy compared to new building construction. As such, it is very important to analyze their preferences for eco-friendly materials prior to project execution. The purpose of this study is to find the needs of residents and priority of their needs. Based on their needs and priority, this paper provides a new strategy in using environment-friendly materials and maximizing their satisfaction level when aged housing remodeling is constructed. In addition, this paper provide new criteria in selecting new developed environmental materials in remodeling projects for the purpose of improving the safety and health level in construction industry.

Accelerating Aging of Transmission Line Porcelain Suspension Insulators by Autoclaving

  • Lee, Won-Kyo;Choi, In-Hyuk;Shin, Koo-Yong;Hwang, Kab-Cheol;Han, Se-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.4
    • /
    • pp.147-150
    • /
    • 2008
  • Porcelain suspension insulators aged for 1, 5 and 10 years on Korean transmission lines and new insulators are tested for autoclave expansion. The compressive strength of the insulators aged in an autoclave with conditions of $250\;^{\circ}C$ and at 20 atm for 30 minutes, was about $7.6\;kgf/mm^2$, which is close to that measured on insulators aged for 10 years in the field. From simulation results, the cement displacement changed linearly with temperature. At a temperature of $200\;^{\circ}C$, the shear stress was approximately $7\;kgf/mm^2$; a stress that is brought about by a 0.07 % expansion of the cement. It is evident that the cement would fracture at a 0.07 % expansion, because the cement has about 7 to $9\;kgf/mm^2$ flexure strength. A turning point in the shear stress with mechanical load occurred at 0.02 % cement expansion. From an analysis of the porcelain body it is shown that there is sufficient margin of strength to guard against fracture of the porcelain body even for a cement expansion more than 0.12 %.

Numerical Analysis of Fracture Behavior in Aged RC Structures (보강된 노후 구조물 파괴거동 예측을 위한 수치해석기법 개발)

  • 신승교;고태호;김문겸;임윤묵
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10b
    • /
    • pp.1031-1036
    • /
    • 2000
  • In this study, a numerical simulation that can effectively predict the strengthening effect of repaired aged RC structures is developed using the axial deformation link elements. In repaired structures, concrete and interface are modeled as quasi-brittle materials. An elastic-perfectly plastic constitutive relationship is introduced for reinforcing bars. Also, a linear-elastic relationship for repair materials such as FRP or CFS. Structural deterioration in terms of corrosion of steel rebar is considered. The interfacial property between steel and concrete which is reduced by corrosion of steel rebar is obtained by comparing numerical results with experimental results of pull out tests. Obtained values are used in repaired reinforced concrete structures under flexural loading conditions. To investigate strengthening effect of the structures repaired with carbon fiber sheet(CFS), repaired and unrepaired RC structures are analyzed numerically. From analysis, rip-off, debonding and rupture failure mechanisms of interface between substrate and CFS can be determined. Finally, strengthening effect according to the variation of interfacial material properties is investigated, and it is shown that interfacial material properties have influence on the mechanical behavior of repaired structure systems Therefore, the developed numerical method using axial deformation link elements can use for determining the strengthening effects and failure mechanism of repaired aged RC structure.

Study on Performance and Aging Test of Porcelain Insulators for Transmission Line (송전용 자기재 애자의 성능평가 및 가속열화시험)

  • 한세원;조한구;박기호;이동일;최인혁
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.9
    • /
    • pp.842-850
    • /
    • 2003
  • The suspension insulators are subjected to harsh environments in service for a long time. The long-term reliability of tile insulators is required for both mechanical and electrical performances. This study describes some basic performance tests and accelerated aging test by cool-heat cycling methods and thermal mechanical performance test methods on alumina porcelain insulators (new and aged) used for transmission line in KOREA. There was no fail in electrical and mechanical performance tests such as a high voltage strength, a flashover voltage, and an impact strength in all samples. But in the case of accelerating aging tests which have above 9$0^{\circ}C$ temperature gradient, fracture phenomena was happened by a thermal shock in tile aged sample(sample A) with low alumina porcelain body. It was indicated that sample A was more severely aged than other samples. According to results of HRB test and microstructural analysis, it was reasoned that insulator bodies with the matrix reinforced with alumina crystalline phase have advantages over the suppression of crack advance. And cool-heat aging and mechanical thermal ageing tests shows that a temperature gradient is more effective to accelerating than a cycling number.

슬리브 시공유형별 기계적 및 열적 가속열화특성 분석 연구

  • An, Sang-Hyeon;Kim, Byeong-Geol;Kim, Sang-Su;Son, Hong-Gwan;Park, In-Pyo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.286-286
    • /
    • 2009
  • According to previous report, aged sleeves for old transmission lines have various defect such as biased installation or corrosion of steel sleeve. These defects can cause serious accidents such as rapid increasing of sag or falling out of overhead conductor from sleeves. Moreover, the defects have been limited power capacity of transmission line. This paper study on mechanical and thermal behavior of ACSR $410mm^2$ conductor and sleeve with various defect model. The conductor has been aged artificially for 50 years. The detailed results were presented in the text.

  • PDF

A Study on Electrical Fire of Small Ventilators due to Aged Degradation (경년열화에 의한 소형 환풍기의 전기화재에 관한 연구)

  • Lim, Jong Yong;Lee, Sung Ill
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.4
    • /
    • pp.22-26
    • /
    • 2016
  • "Always-on" small ventilators are likely to experience thermal decomposition of insulating material due to thermal, electrical, mechanical and environmental influences, and lose insulating properties by the process of oxidation and physiochemical reaction. This increases the risk of electrical fire because of layer short, short circuit, overload and Plastics are usually used to make ventilator and ventilator enclosures since they make less noise and are cheaper. Although more preferred than iron, plastic, a combustible material, has a higher risk of fire. In this study, several experiments were carried out to find out how RCD(Residual Current Protective Device) and Thermal fuses, which are electric motor protection devices, work and what needs to be done to reduce the risk of fire.

Characterization of Undergrounded Distribution Cables - Chemical Structural Defects, Impurities, Degree of Crosslinking and Shrinkage (지중배전 케이블의 특성분석 - 화학구조결함, 불순물, 가교도, 수축율 -)

  • 김종은;고정우;서광석
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.130-134
    • /
    • 1997
  • The structural defects, impurities, degree of crosslinking and shrinkage of 38 field-aged distribution cables have been analyzed. For the comparison of data, 9 new cables were also subjected to an analysis. It is observed that the structural defects and degree of crosslinking show a radial profile. The structural defects are different depending on the manufacturer. A large amount of impurities is present in the insulation shield, which hold true for the new cables manufactured recently. The degree of crosslinking near both shields is lower than that at the central region of the insulation layer. It was also found that, in some cal)toes, the ins난lation was not fully crosslinked. The shrinkage of field-aged cables is higher than that of new cables.

  • PDF

Properties of Insulation System in Rotating Machine Stator Windings (회전기 고정자 권선에서 절연재료의 특성)

  • 박종정;김희동;김희곤;강도열;한상옥
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.326-329
    • /
    • 1997
  • The surface of mica/epoxy paper(130${\mu}{\textrm}{m}$) is investigated with SEM(scanning electron microscope). SEM micrographs revealed that thermal aging has a strong influence on aged specimens. The mica/epoxy paper was exposed at 187$^{\circ}C$ in an ordinary electrical oven for 72hour. Stater windings from two generators were measured by tan delta(tan $\delta$)and maximum partial discharge(Qm). The values of tan $\delta$and Qm were fecund to be higher for new generator than old one. The insulation condition of mica/epoxy paper were measured by ac current and tan $\delta$. Test results are observed that the sound specimens are higher than those aged. Model bar coils subjected to various accelerated agings were evaluated by Qm.

  • PDF

The Evaluation of Thermal Aging Characteristics in Insulating Materials of the Pole Transformers (가속열화 방법에 의한 주상변압기 절연물의 열 열화 특성 평가)

  • 이병성;송일근;이재봉;한상옥
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.12
    • /
    • pp.1136-1141
    • /
    • 2003
  • The primary insulation materials used in an oil filled transformer are kraft paper, wood, porcelain and oil. Modern transformers use chemically treated paper to improve its tensile strength and resistance to aging caused by immersion in oil. But these insulation papers are mainly aged by thermal stress. Over the life time of the insulation paper and oil, it is exposed to high temperatures, oxygen and water. Its interaction with the steel of the tank and core plus the copper and aluminium of the windings will eventually cause the chemical properties of the oil to decay. High temperature have an effect on mechanical strength of cellulous paper used in the layer insulation. We made two aging cells in which insulation papers and mineral oil are conducted to test thermal properties. It is measured dielectric strength, number of acid, moisture, etc. of insulation paper and oil aged in the aging cells.