• Title/Summary/Keyword: age

Search Result 48,782, Processing Time 0.07 seconds

The detection of collapsible airways contributing to airflow limitation (기류 제한에 영향을 미치는 허탈성 기도의 분석)

  • Kim, Yun Seong;Park, Byung Gyu;Lee, Kyong In;Son, Seok Man;Lee, Hyo Jin;Lee, Min Ki;Son, Choon Hee;Park, Soon Kew
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.4
    • /
    • pp.558-570
    • /
    • 1996
  • Background : The detection of Collapsible airways has important therapeutic implications in chronic airway disease and bronchial asthma. The distinction of a purely collapsible airways disease from that of asthma is important because the treatment of the dormer may include the use of pursed lip breathing or nasal positive pressure ventilation whereas in the latter, pharmacologic approaches are used. One form of irreversible airflow limitation is collapsible airways, which has been shown to be a Component of asthma or to emphysema, it can be assessed by the volume difference between what exits the lung as determined by a spirometer and the volume compressed as measured by the plethysmography. Method : To investigate whether volume difference between slow and forced vital Capacity(SVC-FVC) by spirometry may be used as a surrogate index of airway collapse, we examined pulmonary function parameters before and after bronchodilator agent inhalation by spirometry and body plethysmography in 20 cases of patients with evidence of airflow limitation(chronic obstructive pulmonary disease 12 cases, stable bronchial asthma 7 cases, combined chronic obstructive pulmonary disease with asthma 1 case) and 20 cases of normal subjects without evidence of airflow limitation referred to the Pusan National University Hospital pulmonary function laboratory from January 1995 to July 1995 prospectively. Results : 1) Average and standard deviation of age, height, weight of patients with airflow limitation was $58.3{\pm}7.24$(yr), $166{\pm}8.0$(cm), $59.0{\pm}9.9$(kg) and those of normal subjects was $56.3{\pm}12.47$(yr), $165.9{\pm}6.9$(cm), $64.4{\pm}10.4$(kg), respectively. The differences of physical characteristics of both group were not significant statistically and male to female ratio was 14:6 in both groups. 2) The difference between slow vital capacity and forced vital capacity was $395{\pm}317ml$ in patients group and $154{\pm}176ml$ in normal group and there was statistically significance between two groups(p<0.05). Sensitivity and specificity were most higher when the cut-off value was 208ml. 3) After bronchodilator inhalation, reversible airway obstructions were shown in 16 cases of patients group, 7 cases of control group(p<0.05) by spirometry or body plethysmography d the differences of slow vital capacity and forced vital capacity in bronchodilator response group and nonresponse group were $300.4{\pm}306ml$, $144.7{\pm}180ml$ and this difference was statistically significant. 4) The difference between slow vital capacity and forced vital capacity before bronchodilator inhalation was correlated with airway resistance before bronchodilator(r=0.307 p=0.05), and the difference between slow vital capacity and forced vital capacity after bronchodilator was correlated with difference between slow vital capacity and forced vital capacity(r=0.559 p=0.0002), thoracic gas volume(r=0.488 p=0.002) before bronchodilator and airway resistance(r=0.583 p=0.0001), thoracic gas volume(r=0.375 p=0.0170) after bronchodilator, respectively. 5) The difference between slow vital capacity and forced vital capacity in smokers and nonsmokers was $257.5{\pm}303ml$, $277.5{\pm}276ml$, respectively and this difference did not reach statistical significance(p>0.05). Conclusion : The difference between slow vital capacity and forced vital capacity by spirometry may be useful for the detection of collapsible airway and may help decision making of therapeutic plans.

  • PDF

Relationship between Systemic Inflammatory Marker, Oxidative Stress and Body Mass Index in Stable COPD Patient (안정된 만성폐쇄성폐질환 환자에서 신체질량지수와 전신 염증인자, 산화 스트레스와의 관련성)

  • Ham, Hyun Seok;Lee, Hae Young;Lee, Seung Jun;Cho, Yu Ji;Jeong, Yi Young;Kim, Ho Cheol;Ham, Jong Ryeal;Park, Chan Hoo;Lee, Jong Deok;Sohn, Hyun Joon;Youn, Hee Shang;Hwang, Young Sil
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.4
    • /
    • pp.330-338
    • /
    • 2006
  • Background: The main factors associated with weight loss in patients with COPD are not well known. Since chronic inflammation and oxidative stress play a major pathogenic role in COPD, these factors may be responsible for the patients' weight loss. Therefore, this study measured the body mass index (BMI) in COPD patients and evaluated the variables, such as systemic inflammatory marker, oxidative stress and lung function, that correlate with the BMI. Method: The stable COPD patients (M:F=49:4, mean age=$68.25{\pm}6.32$) were divided into the lower (<18.5), normal (18.5-25) and higher (>25) BMI group. The severity of the airway obstruction was evaluated by measuring the $FEV_1$. The serum IL-6 and TNF-$\alpha$ levels were measured to determine the degree of systemic inflammation, and the carbonyl protein and 8-iso-prostaglandin $F_2{\alpha}$ level was measured to determine the level of oxidative stress. Each value in the COPD patients and normal control was compared with the BMI. Results: 1) Serum 8-iso-prostaglandin $F_2{\alpha}$ in COPD patients was significantly higher ($456.08{\pm}574.12pg/ml$) than that in normal control ($264.74{\pm}143.15pg/ml$) (p<0.05). However, there were no significant differences in the serum IL-6, TNF-$\alpha$, carbonyl protein between the COPD patients and normal controls. 2). In the COPD patients, the $FEV_1$ of the lower BMI group was significantly lower ($0.93{\pm}0.25L$) than that of the normal BMI ($1.34{\pm}0.52L$) and higher BMI groups ($1.72{\pm}0.41L$) (p<0.05). The lower $FEV_1$ was significantly associated with a lower BMI in COPD patients (p=0.002, r=0.42). The BMI of very severe COPD patients was significantly lower ($19.8{\pm}2.57$) than that of the patients with moderate COPD ($22.6{\pm}3.14$) (p<0.05). 3). There were no significant differences in the serum IL-6, TNF-$\alpha$, carbonyl protein and 8-iso-prostaglandin $F_2{\alpha}$ according to the BMI in the COPD patients. Conclusion: The severity of the airway obstruction, not the systemic inflammatory markers and oxidative stress, might be associated with the BMI in stable COPD patients. Further study will be needed to determine the factors associated with the decrease in the BMI of COPD patients.

Study on Acknowledge and State of Clinical Experience for 3-years Dental Technology Department (3년제 치기공과 임상실습에 대한 인식 및 실태조사 - 일부 치과기공소 소장을 중심으로 -)

  • Park, Myung-Ja
    • Journal of Technologic Dentistry
    • /
    • v.17 no.1
    • /
    • pp.41-57
    • /
    • 1995
  • This study was conducted to collect and analyze previous information in order to manage efficience, improve experience effect and promote employment rate. The questionnaire interview with 27 chief of dental Laboratory refered clinical experience in technology department about clinical experience in 14 Jumior colleges were also investigated. The results were summarried as follows : The portion of age of 35-39 among chief of dental Laboratory was 40.7% which was the highest, that of male was 96.3%, that of junior college graduate was 97.5%, that of 10years experience was 92.6% and that of ceramic technician was 85.2%, 63.0% dental laboratory for clinical experience was a bore space of 30pyong. Aspect of dental laboratory management, manufacturing all part of prosthetic restoration was 29.6%, othodontic appliance and ceramic restoration was 7.4%, 3.8%, each. The percentage of 40.7 was having connection with 30-3a dental clinics and referring case per day was 10-19 cases(40.7%), manufacturing time of referred prosthetic restoration was 3-4 days(77.8%), places preparing seminar room for education was 29.6%, above a place of 40pyong was 11.1% 30-34 pyong and 35-39 pyong was 7.4% each. During training of 2 years education course student, 18.5% was rack of thorough occupational career. While 44.4% will want the more salary among 3years education course student, 74.1% will expect the more dental techmicians would engaged in their field, 51.9% will hope improve of their theory and practice, 29.6% be expected better skill and 14.8% be expected better theory. Attitude of clinical experience places was distributed by 59.3% of offering only experience chance, 25.9% of wasting time and 29.0% of annoying. The big emphasis of climical experience was thorough occupational career(44.4%). The clinical experience places of our college were selected after direct visiting, so their condition of management was not that bad but most of dental laboratory were poor in management state and working environment. Therefore it is difficult to choose appropriate places and dental Laboratory are also limited manpower and time as suppliers. So that it recommended to induce flexible management of experience period by interval and rotation of experience places among college and to applicate intern-system for employment ant industry-college cooperation aspect.

  • PDF

Smoking-Induced Dopamine Release Studied with $[^{11}C]Raclopride$ PET ($[^{11}C]Raclopride$ PET을 이용한 흡연에 의한 도파민 유리 영상 연구)

  • Kim, Yu-Kyeong;Cho, Sang-Soo;Lee, Do-Hoon;Ryu, Hye-Jung;Lee, Eun-Ju;Ryu, Chang-Hung;Jeong, In-Soon;Hong, Soo-Kyung;Lee, Jae-Sung;Seo, Hong-Gwan;Jeong, Jae-Min;Lee, Won-Woo;Kim, Sang-Eun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.421-429
    • /
    • 2005
  • Purpose: It has been postulated that dopamine release in the striatum underlies the reinforcing properties of nicotine. Substantial evidence in the animal studies demonstrates that nicotine interacts with dopaminergic neuron and regulates the activation of the dopaminergic system. The aim of this study was to visualize the dopamine release by smoking in human brain using PET scan with $[^{11}C]raclopride$. Materials and Methods: Five male non-smokers or ex-smokers with an abstinence period longer than 1 year (mean age of $24.4{\pm}1.7$ years) were enrolled in this study $[^{11}C]raclopride$, a dopamine D2 receptor radioligand, was administrated with bolus-plus-constant infusion. Dynamic PET was performed during 120 minutes ($3{\times}20s,\;2{\times}60s,\;2{\times}120s,\;1{\times}180s\;and\;22{\times}300s$). following the 50 minute-scanning, subjects smoked a cigarette containing 1 mg of nicotine while in the scanner. Blood samples for the measurement of plasma nicotine level were collected at 0, 5, 10, 15, 20, 25, 30, 45, 60, and 90 minute after smoking. Regions for striatal structures were drawn on the coronal summed PET images guided with co-registered MRI. Binding potential, calculated as (striatal-cerebellar)/cerebellar activity, was measured under equilibrium condition at baseline and smoking session. Results: The mean decrease in binding potential of $[^{11}C]raclopride$ between the baseline and smoking in caudate head, anterior putamen and ventral striatum was 4.7%, 4.0% and 7.8%, respectively. This indicated the striatal dopamine release by smoking. Of these, the reduction in binding potential in the ventral striatum was significantly correlated with the cumulated plasma level of the nicotine (Spearman's rho=0.9, p=0.04). Conclusion: These data demonstrate that in vivo imaging with $[^{11}C]raclopride$ PET could measure nicotine-induced dopamine release in the human brain, which has a significant positive correlation with the amount or nicotine administered bt smoking.

An Ultrastructural Study on the Development of the Knee Joint in the Human Fetus (인태아 슬관절 발육에 관한 전자현미경적 연구)

  • Kim, Baik-Yoon;Joo, Ki-Jung;Nam, Kwang-Il;Yoon, Jae-Rhyong
    • Applied Microscopy
    • /
    • v.30 no.2
    • /
    • pp.213-232
    • /
    • 2000
  • The development of the knee joint was studied by electron microscopy in human fetuses ranging from 20 mm to 260 mm crown-rump length ($7\sim30$ weeks of gestational age). The appearance of the primordium of the meniscus and cruciate ligament was conspicuous as the mesenchymal cells , preceeding that of joint space at 30 mm fetus. The primitive joint cavity was first seen in the interzone from the 40 mm fetus and its intermediate layer proceeded developing as a narrow cleft which was closely incorporated with two chondrogenic layers. Poorly differentiated mesenchymal cells of the meniscus at 40 mm fetus containing predominantly free ribosomes differentiated into fibroblasts at 60 mm fetus. By 100 mm fetus, the fibroblast in inner zone of the meniscus presented as oval profiles with a short cell processes, whereas middle and peripheral zones presented as elongated cells. Differentiation of the synovial membrane coincided with clarification of the joint cavity When dilatation of the synovial cavity occurred, the two types of synovial cells were identified at 60 mm fetus. By 100 mm fetus a majority of the intimal cells were B-type. B-type cells were clearly distinguishable from A-type cells by their content of extensive rough endoplasmic reticula and well developed Golgi complexes. In contrast, A-type cells had numerous filopodia, pinocytotic vesicles, lysosomes and large vacuoles. At 260 mm fetus the B-type cells were also a majority of intimal cells. At 260 mm fetus the inner zone of the meniscus was filled with parallel oriented fascicles of collagenous fibers and oval fibroblasts. The middle zone was constituted of parallel and radially arranged fibers and fibroblasts. The outer zone was populated by elongated fibroblasts encircled by crossed collagenous fibers with the blood vessels. At 30 mm fetus the fibroblasts of the cruciate ligament contained rough endoplasmic reticula and mitochondria. Collagen fibrils were noted within narrow cytoplasmic processes which were continued with the extracellular space. Collagen fibrils of ligament were filled in the bulk of extracellular space at 100 mm fetus. By $150\sim260mm$ fetus, the cruciate ligaments were constituted of longitudinally oriented bundle of collagen fibrils with irregular rows of round cells between.

  • PDF

A Study on the Extraction Rate of Brain Tissues from a $^{99m}Tc$-HMPAO Cerebral Blood flow SPECT Examination of a Patient ($^{99m}Tc$-HMPAO 뇌혈류 SPECT 검사 시 환자에 따른 뇌조직 추출률에 대한 고찰)

  • Kim, Hwa-San;Lee, Dong-Ho;Ahn, Byeong-Pil;Kim, Hyun-Ki;Jung, Jin-Yung;Lee, Hyung-Nam;Kim, Jung-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.17-26
    • /
    • 2012
  • Purpose: This study mainly focuses on the patients treated with chemically stable radiopharmaceutical product $^{99m}Tc$-HMPAO (d,l-hexamethylpropylene amine oxime) which yielded reduced image quality due to a decreased brain extraction rate. $^{99m}Tc$-HMPAO will be examined further to determine whether this product may be accounted as a factor for this cause. Material and Methods: From January 2010 until December 2010, out of 272 patients who were all subjected to $^{99m}Tc$-HMPAO brain blood flow SPECT scans resulting from Cerebral Infarction; 23 patients(ages $55.3{\pm}9$, 21 males, 3 females) with decreased tissue extraction rate were examined in detail. The radiopharmaceutical product $^{99m}Tc$-HMPAO was used on patients with normal brain tissue exchange rate as well as those with reduced rate in order to prove its' chemical stability. The patients' age, sex, blood pressure, existence of diabetes, drug use, current health status, known side effects from CT/MRI, examination of the patients' past SPECT before/after images were accounted to determine the factors and correlations affecting the rate of blood tissue extractions. Result: After multiple linear regression analysis, there were no unusual correlations between the 6 factors excluding sex, and before/after examination images. Male subjects showed reduced brain tissue extraction rate than the females ($p$ > 0.05) 91.3% male, 8.7% female. Wilcoxon Matched-Pairs Signed-Ranks Test was used on the before/after images which yielded a value of 0.06, which did not indicate a significant amount of difference on the 2 tests ($p$ > 0.05). As a result, the before/after images indicated similar brain tissue extraction rates, and there were variations depending on the individual patient. Conclusion: The effects of the chemically stable radiopharmaceutical product $^{99m}Tc$-HMPAO depended on the patient's personal characteristics and status, therefore was considered to be a factor in reducing brain tissue extraction rate. The related articles of $^{99m}Tc$-HMPAO cerebral blood flow SPECT speculates a cerebrovascular disease and factors resulting from portal veins, and it was not possible to pin point the exact cause of decreasing brain tissue extraction rate. However, the $^{99m}Tc$-HMPAO cerebral blood flow SPECT scan proved to be extremely useful in tracking and inspecting brain diseases, as well as offering accurate results from patients suffering from reduced brain tissue extraction rates.

  • PDF

Analysis of Patient Effective Dose in PET/CT; Using CT Dosimetry Programs (CT 선량 측정 프로그램을 이용한 PET/CT 검사 환자의 예측 유효 선량의 분석)

  • Kim, Jung-Sun;Jung, Woo-Young;Park, Seung-Yong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.77-82
    • /
    • 2010
  • Purpose: As PET/CT come into wide use, it caused increasing of expose in clinical use. Therefore, Korea Food and Drug Administration issued Patient DRL (Diagnostic Reference Level) in CT scan. In this study, to build the basis of patient dose reduction, we analyzed effective dose in transmission scan with CT scan. Materials and Methods: From February, 2010 to March 180 patients (age: $55{\pm}16$, weight: $61.0{\pm}10.4$ kg) who examined $^{18}F$-FDG PET/CT in Asan Medical Center. Biograph Truepoint 40 (SIEMENS, GERMANY), Biograph Sensation 16 (SIEMENS, GERMANY) and Discovery STe8 (GE healthcare, USA) were used in this study. Per each male and female average of 30 patients doses were analyzed by one. Automatic exposure control system for controlling the dose can affect the largest by a patient's body weight less than 50 kg, 50-60 kg less, 60 kg more than the average of the three groups were divided doses. We compared that measured value of CT-expo v1.7 and ImPACT v1.0. The relationship between body weight and the effective dose were analyzed. Results: When using CT-Expo V1.7, effective dose with BIO40, BIO16 and DSTe8 respectably were $6.46{\pm}1.18$ mSv, $9.36{\pm}1.96 $mSv and $9.36{\pm}1.96$ mSv for 30 male patients respectably $6.29{\pm}0.97$ mSv, $10.02{\pm}2.42$ mSv and $9.05{\pm}2.27$ mSv for 30 female patients respectably. When using ImPACT v1.0, effective dose with BIO40, BIO16 and DSTe8 respectably were $6.54{\pm}1.21$ mSv, $8.36{\pm}1.69$ mSv and $9.74{\pm}2.55$Sv for 30 male patients respectably $5.87{\pm}1.09$ mSv, $8.43{\pm}1.89$ mSv and $9.19{\pm}2.29$ mSv for female patients respectably. When divided three groups which were under 50 kg, 50~60 kg and over 60 kg respectably were 6.27 mSv, 7.67 mSv and 9.33 mSv respectably using CT-Expo V1.7, 5.62 mSv, 7.22 mSv and 8.91 mSv respectably using ImPACT v1.0. Weight and the effective dose coefficient analysis showed a very strong positive correlation(r=743, r=0.693). Conclusion: Using such a dose evaluation programs, easier to predict and evaluate the effective dose possible without performing phantom study and such dose evaluation programs could be used to collect basic data for CT dose management.

  • PDF

The Quantitative Assessment of Renal Function and Size by Differences of Acquisition Counts in $^{99m}Tc$-DMSA Renal Scan ($^{99m}Tc$-DMSA 신장검사에서 획득 계수의 차이에 따른 기능 및 형태 평가)

  • Shim, Dong-Oh;Kim, Ho-Sung;Chung, Eun-Mi
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.117-121
    • /
    • 2010
  • Purpose: In nuclear medicine study, there are two methods, preset count method and preset time method, to acquire static images. We usually use preset count method for static image in $^{99m}Tc$-DMSA renal scan, but occasionally use preset time method. In case of using preset count method, we always acquire same counts but it causes a difference of scan time. In case of using preset time method, it takes same scan time to acquire images but it causes different counts. Therefore, the purpose of this study is to investigate any differences of function and formal information in both kidney by acquisition counts Materials and Methods: From January 11, 2010 to March 31, 2010, we analyzed the 30 patients (M: 11, W: 19). who were examined by $^{99m}Tc$-DMSA scan and have one side of functioning kidney relatively between 40~60%. And the patients who have cold and hot region in image were analyzed but we did not accept images of patients when it was hard to divide kidney into cortex. There was no division between subjects and age of subjects is $14.83{\pm}22.07$ old. We used the BrightView gamma camera from PHILIPS. To analyze function and formal of kidney, we used JET stream release 3.0 version from PHILIPS. Using SPSS 12.0 program, we compared descriptive statistics and paired T-test. Images were acquired sequentially in the same parameters, but there are three methods which different from acquisition time and scan time, 100 kcounts, 300 kcounts and 7 minutes method (exceed 300 kcounts). To assess function and formal information of kidney, we measured renal relative function, geometric mean and size of kidney and analyzed each difference. Results: In case of renal relative function in both kidney, 100 kcounts method was $50.52{\pm}3.64%$. 300 kcounts method was $50.38{\pm}3.66%$ and 7 minutes method was $49.91{\pm}3.40%$ and there were no statistical significant differences between each method. In case of geometric mean, 100 kcounts method was $50.08{\pm}3.25%$. 300 kcounts method was $49.89{\pm}3.40%$ and 7 minutes method was $49.91{\pm}3.24%$. And also, there were no statistical significant differences. When comparing size of kidney, 100 kcounts method was $8.23{\pm}1.96$ cm. 300 kcounts method was $8.12{\pm}1.90$ cm and 7 minutes method was $8.35{\pm}1.97$ cm. In case of right kidney, 100 kcounts method was $7.91{\pm}1.88$ cm. 300 kcounts method was $8.12{\pm}1.90$ cm and 7 minutes method was $8.25{\pm}1.96$ cm. From those values, we recognized that there were significant differences each method (p<0.05). Conclusion: From results of this study, there were no statistical differences in renal relative function and geometric mean by acquisition counts. However, in shape of kidney, the more acquisition counts are increasing, the more size of kidney is getting big. And there were statistical significant differences. Therefore, to perform reliable quantitative result, preset count method is more desirable than preset time method. Especially, in case of a follow-up test, if we use preset time method, it will cause differences of formal results in kidney due to acquisition counts each time we examine patients.

  • PDF

Evaluation of Artifacts by Dental Metal Prostheses and Implants on PET/CT Images: Phantom and Clinical Studies (PET/CT 영상에서의 치과재료에 의한 인공물에 관한 연구)

  • Bahn, Young-Kag;Park, Hoon-Hee;NamKoong, Hyuk;Cho, Suk-Won;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.110-116
    • /
    • 2010
  • Purpose: The X-ray attenuation coefficient based on CT images is used for attenuation correction in PET/CT. The polychromatic X-ray beam can introduce beam-hardening artifact on CT images. The aims of the study were to evaluate the effect of dental metal prostheses in phantom and patients on apparent tracer activity measured with PET/CT when using CT attenuation correction. Materials and Methods: 40 normal patients (mean age $54{\pm}12$) was scanned between Jan and Feb 2010. NEMA(National Electrical Manufactures Association) PET $Phantom^{TM}$ (NU2-1994) was filled with $^{18}F$-FDG injected into the water that insert implant and metal prostheses dental cast. Region of interest were drawn in non-artifact region, bright steak artifact region and dark streak artifact region on the same transaxial CT and PET slices. Patients and phantom with dental metal prostheses and dental implant were evaluated the change rate of CT Number and $SUV_{mean}$ in PET/CT. A paired t-test was performed to compare the ratio and the difference of the calculated values. Results: In patients with dental metal prostheses, $SUV_{mean}$ was reduced 19.64% (p<0.05) in the non-steak artifact region than the brightstreak artifact region whereas was increased 90.1% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In phantom with dental metal prostheses, $SUV_{mean}$ was reduced 18.1% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 18.0% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In patients with dental implant, $SUV_{mean}$ was increased 19.1% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 96.62% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In phantom with dental implant, $SUV_{mean}$ was increased 14.4% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 7.0% (p>0.05) in the non-steak artifact region than the dark streak artifact region. Conclusion: When CT is used for attenuation correction in patients with dental metal prostheses, 19.1% reduced $SUV_{mean}$ is anticipated in the dark streak artifact region on CT images. The dark streak artifacts of CT by dental metal prostheses may cause false negative finding in PET/CT. We recommend that the non-attenuation corrected PET images also be evaluated for clinical use.

  • PDF

A Study to Decrease Exposure Dose for the Radiotechnologist in PET/CT (PET/CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구)

  • Cho, Seok-Won;Park, Hoon-Hee;Kim, Jung-Yul;Ban, Yung-Kak;Lim, Han-Sang;Oh, Ki-Beak;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.159-165
    • /
    • 2010
  • Purpose: Positron emission tomography scan has been growing diagnostic equipment in the development of medical imaging system. Compare to $^{99m}Tc$ emitting 140 keV, Positron emission radionuclide emits 511 keV gamma rays. Because of this high energy, it needs to reduce radioactive emitting from patients for radiotechnologist. We searched the external dose rates by changing distance from patients and measure the external dose rates when we used shielder investigate change external dose rates. In this study, the external dose distribution were analyzed in order to help managing radiation protection of radiotechnologists. Materials and Methods: Ten patients were searched (mean age: $47.7{\pm}6.6$, mean height: $165.5{\pm}3.8$ cm and mean weight: $65.9{\pm}1.4$ kg). Radiation were measured on the location of head, chest, abdomen, knees and toes at the distance of 10, 50, 100, 150 and 200 cm. Then, all the procedure was given with a portable radiation shielding on the location of head, chest and abdomen at the distance of 100, 150 and 200 cm and transmittance was calculated. Results: In 10 cm, head (105.40 ${\mu}Sv/h$) was the highest and foot (15.85 ${\mu}Sv/h$) was the lowest. In 200 cm, head, chest and abdomen showed similar. On head, the measured dose rates were 9.56 ${\mu}Sv/h$, 5.23 ${\mu}Sv/h$, and 3.40 ${\mu}Sv/h$ in 100, 150 and 200 cm respectively. When using shielder, it shows 2.24 ${\mu}Sv/h$, 1.67 ${\mu}Sv/h$, and 1.27 ${\mu}Sv/h$ in 100, 150 and 200 cm on head. On chest, the measured dose rates were 8.54 ${\mu}Sv/h$, 4.90 ${\mu}Sv/h$, 3.44 ${\mu}Sv/h$ in 100, 150 and 200 cm, respectively. When using shielder, it shows 2.27 ${\mu}Sv/h$, 1.34 ${\mu}Sv/h$, and 1.13 ${\mu}Sv/h$ in 100, 150 and 200 cm on chest. On abdomen, the measured dose rates were 9.83 ${\mu}Sv/h$, 5.15 ${\mu}Sv/h$ and 3.18 ${\mu}Sv/h$ in 100, 150 and 200cm respectively. When using shielder, it shows 2.60 ${\mu}Sv/h$, 1.75 ${\mu}Sv/h$ and 1.23 ${\mu}Sv/h$ in 100, 150 and 200 cm on abdomen. Transmittance was increased as the distance was expanded. Conclusion: As the distance was further, the radiation dose were reduced. When using shielder, the dose were reduced as one-forth of without shielder. The Radio technologists are exposed of radioactivity and there were limitations on reducing the distance with Therefore, the proper shielding will be able to decrease radiation dose to the radiotechnologists.

  • PDF