• 제목/요약/키워드: aerosol

검색결과 1,733건 처리시간 0.029초

마스크 필터의 효율 최적화 및 호흡 저항 감소에 관한 연구 (A Study on Optimization of Mask Filter and Reduction in Respiratory Resistance)

  • 권세현;홍자영;정상빈;허기준;이병욱
    • 한국입자에어로졸학회지
    • /
    • 제12권3호
    • /
    • pp.103-107
    • /
    • 2016
  • We conducted experiments on mask filters. We measured filtering efficiencies of several new mask filters which were manufactured by disassembling and reassembling of one type of mask filter. New filter (A+C: combination of the first layer and the third layer of the tested mask filter) showed the highest efficiency (97.7%) with the respiratory resistance of 98 pa.

연삭가공에서 절삭유 에어로졸 측정평가에 관한 연구 (A Study on the Analysis of Cutting Fluid Aerosol in Grinding Process)

  • 황준;황덕철;우창기;정의식
    • 한국공작기계학회논문집
    • /
    • 제14권5호
    • /
    • pp.1-6
    • /
    • 2005
  • Machining is a one of the broadly used manufacturing process to produce the parts, products and various molds and dies. The environmental impact due to aerosol generation via atomization process is a major concern associated with environmental consciousness. This paper presents the experimental results to analyze the characteristics of cutting fluid aerosol generation in grinding process. Experimental results show that the generated fine aerosol which particle size less than 10micron appears near worker's breath zone under given operational conditions. The aerosol concentration is much higher enough to affect human health risk with its generated aerosol quantities. This quantitative analysis can be provided the basic knowledge f3r further research for environmentally conscious machining technology developments.

연삭가공에서 절삭유 에어로졸 측정평가에 관한 연구 (A Study on the Analysis of Cutting Fluid Aerosol in Grinding Process)

  • 황준;황덕철;우창기;정의식
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2005년도 춘계학술대회 논문집
    • /
    • pp.282-287
    • /
    • 2005
  • This paper presents the experimental results to analyze the characteristics of cutting fluid aerosol generation in grinding process. Machining is a one of the broad manufacturing process to produce the parts, products and various molds and dies. The environmental impact due to aerosol generation via atomization process is a major concern associated with environmental consciousness. Experimental results show that the generated fine aerosol which particle size less than 10 micron appears near worker's breath zone under given operational conditions. The aerosol concentration is much higher enough to affect human health risk with its generated aerosol quantities. This qualitative analysis can be provided the basic knowledge for further research for environmentally conscious machining technology developments.

  • PDF

잠실내에 있어서 병원성 Aspergilli에 대한 Aerosol의 살균효과 (Studies on fungicidal effectiveness of aerosol for pathogenic aspergilli)

  • 김충흠;사기언;한계용
    • 미생물학회지
    • /
    • 제8권4호
    • /
    • pp.173-177
    • /
    • 1970
  • In this study the effect of aerosol for the control of the parasitic Aspergilli in the sericultural room was investigated. The results obtained are summarized as follows : 1) The aerosol of PPS-A and PPS-B were quite effective for the control of parasitic Aspergilli in the room of sericulture, while the solution of formalin and chlor kalk, on the other hand, were inconclusive. 2) The activities of the aerosol of PPS-A and PPS-B are more effective when it is applied on the upper part of the room than the lower.

  • PDF

Aerosol Mass Spectrometer (AMS)-Based Real-Time Physicochemical Characterization of Atmospheric Aerosols

  • Kim, Donghwi
    • Mass Spectrometry Letters
    • /
    • 제13권2호
    • /
    • pp.27-34
    • /
    • 2022
  • Atmospheric aerosols have become a major environmental concern because of their adverse effects on human health, air quality, and climate change. Over the last few decades, several mass spectrometry (MS)-based techniques have been developed and applied in the field of atmospheric aerosol research. Particularly, real-time measurement of ambient aerosols using an aerosol mass spectrometer (AMS) has become one of the most powerful tools for aerosol chemistry. This review provides a brief description of AMS and its applications for understanding the physicochemical properties of atmospheric aerosols, as well as its sources and evolution processes.

ECMWF/MACC와 OPAC자료를 이용한 시너지 에어로솔 모델 산출 (Derivation of Synergistic Aerosol Model by Using the ECMWF/MACC and OPAC)

  • 이권호;이규태;문관호;김정호;정경진
    • 대한원격탐사학회지
    • /
    • 제34권6_1호
    • /
    • pp.857-868
    • /
    • 2018
  • 특정 지점에서 대기 에어러솔의 미세물리적 특성과 시공간적 분포는 에어로솔 입자의 광학특성을 파악하기 위한 중요한 변수이다. 이러한 에어러솔의 광학특성값에 대한 정확한 산출은 복사전달 모의 과정에서 정확한 값을 제공함으로 중요한 역할을 가지게 된다. 따라서 본 연구는 사용자가 요구하는 시공간적 조건에서 정확한 에어로솔 모델을 산출하기 위한 방법으로서 재분석 자료와 광학 특성 데이터 베이스를 이용한 시너지 에어로솔 모델을 산출하는 방법을 제시하였다. 제안된 시너지 에어로솔 모델은 에어로솔의 주요 성분별 광학두께(Aerosol Optical Depth; AOD)값에 의하여 가중치가 적용된 혼합 에어러솔 형태의 광학 모델을 산출하기 위함이며, $40{\mu}m$까지의 파장영역에서 광학특성값을 제공한다. 주요 에어로솔 이벤트 사례에 대하여, 시너지적 에어러솔 모델(Synergy Aerosol Model; SAM)은 기존의 복사전달 모델에서 사용되고 있는 표준 에어러솔 모델과는 차별적인 결과를 보여주었으며, 지상관측 Aerosol Robotic Network(AERONET) inversion 산출물과의 비교를 통하여 오차범위 내의 정량적인 결과를 가지고 있는 것을 보였다. 따라서, 복사전달 모의에 있어 시너지 에어로솔 모델의 사용은 실제 대기 중 에어러솔에 의한 영향을 정량적으로 평가하는데 도움을 줄 수 있을 것이며, 개선된 복사 모의 결과를 얻을 수 있을 것이다.

Effects of Aerosolized Sanitizers of Different Droplet Sizes on Foodborne Pathogen Reduction

  • Kim, Young-Ho;Jo, Young-Jun;Kim, Yun-Ji;Koo, Min-Seon;Lee, Jong-Kyung;Oh, Se-Wook
    • Food Science and Biotechnology
    • /
    • 제17권3호
    • /
    • pp.664-668
    • /
    • 2008
  • The diffusivity of aerosol sanitizers may be determined by the weight and droplet size of the aerosol. To test the effects of droplet size, 2 types of aerosol sanitizers were prepared using different ultrasonic nebulizer frequencies (1.6 and 2.4 MHz) and their reduction activities were determined against Escherichia coli O157:H7, Listeria monocytogenes, and Salmonella typhimurium. A sodium hypochlorite aerosol was treated for 10, 30, or 60 min in a model aerosol cabinet. When the aerosol prepared by nebulizing at 1.6 MHz was treated for 30 min, a 0.2 log reduction was observed in E. coli O157:H7 and 0.3 log reductions were exhibited in L. monocytogenes and S. typhimurium, respectively. After 60 min, the 3 pathogens were reduced by 1.7, 0.6, and 0.8 log units, respectively. However, when the aerosol prepared by nubulizing at 2.4 MHz was treated, the microbes presented 1.6, 0.5, and 0.6 log reductions at 30 min, and 1.8, 0.9, and 1.1 log reductions at 60 min of treatment, respectively.

405 nm 광원을 이용한 생물입자탐지기의 에어로졸 분석성능 (The performance of Bio-aerosol Detection System (BDS) with 405 nm laser diode)

  • 정영수;정유진;이종민;최기봉
    • 한국입자에어로졸학회지
    • /
    • 제13권1호
    • /
    • pp.25-31
    • /
    • 2017
  • This paper offer the characteristics for the detection and classification of biological and non-biological aerosol particles in the air by using laser-induced-fluorescence (LIF) based Bio-aerosol Detection System (BDS). The BDS is mainly consist of an optical chamber, in-outlet nozzle system, 405 nm diode laser, an avalanche photo detector (APD) for scattering signal and photomultiplier tubes (PMT) for fluorescence signals in two different wavelength range ; F1, 510-600 nm and F2, 435-470 nm. The detection characteristics, especially ratio of fluorescence signal intensity were examined using well-known components : polystylene latex (PSL), fluorescence PSL, $2{\mu}m$ of SiO2 micro sphere, dried yeast, NADH, ovalbumin, fungicide powder and standard dust. The results indicated that the 405 nm diode laser-based LIF instrument can be a useful bio-aerosol detection system for unexpected biological threaten alter in real-time to apply for dual-use technology in military and civilian fields.

패러데이 케이지와 에어로졸 하전기의 설계 및 성능평가 (Design and Performance Evaluation of a Faraday Cage and an Aerosol Charger)

  • 지준호;배귀남;황정호
    • 대한기계학회논문집B
    • /
    • 제28권3호
    • /
    • pp.315-323
    • /
    • 2004
  • An electrical cascade impactor is a multi-stage impaction device to separate airborne particles into aerodynamic size classes using particle charging and electrical detection techniques. A Faraday cage and an aerosol charger, which are basic components of the electrical cascade impactor, were designed and evaluated in this study. The low-level current response of the Faraday cage was investigated with changing particle size and air flow rate by using sodium chloride (NaCl) particles. The response of the prototype Faraday cage was very similar to that of a commercial aerosol electrometer (TSI model 3068) within ${\pm}$5% for singly-charged particles. The response linearity of the prototype Faraday cage could be extended up to flow rate of 30 L/min. For the performance evaluation of the aerosol charger the monodisperse liquid dioctyl sebacate (DOS) particles, with diameters of 0.1∼0.8$\mu\textrm{m}$, were generated using spraying from an atomizer followed by evaporation-condensation process. Typical performance parameters of the aerosol charger such as P$.$n, wall loss, and elementary charges per particle were evaluated. The performance of the prototype aerosol charger was found to be close to that of the aerosol charger used in an electrical low pressure impactor (ELPI, Dekati).

Estimation and Validation of Collection 6 Moderate Resolution Imaging Spectroradiometer Aerosol Products for East Asia

  • Lee, Kwon-Ho
    • Asian Journal of Atmospheric Environment
    • /
    • 제12권3호
    • /
    • pp.193-203
    • /
    • 2018
  • The operational aerosol retrieval algorithm for the Moderate Resolution Imaging Spectroradiometer (MODIS) measurements was recently updated and named collection 6 (C6). The C6 MODIS aerosol algorithm, a substantially improved version of the collection 5 (C5) algorithm, uses an enhanced aerosol optical thickness(AOT) retrieval process consisting of new surface reflection and aerosol models. This study reports on the estimation and validation of the two latest versions, the C5 and C6 MODIS aerosol products over the East Asian region covering $20^{\circ}N$ to $56^{\circ}N$ and $80^{\circ}E$ to $150^{\circ}E$. This study also presents a comparative validation of the two versions(C5 and C6) of algorithms with different methods(Dark Target(DT) and Deep Blue (DB) retrieval methods) from the Terra and Aqua platforms to make use of the Aerosol Robotic Network (AERONET) sites for the years 2000-2016. Over the study region, the spatially averaged annual mean AOT retrieved from C6 AOT is about 0.035 (5%) less than the C5 counterparts. The linear correlations between MODIS and AERONET AOT are R = 0.89 (slope = 0.86) for C5 and R = 0.95 (slope = 1.00) for C6. Moreover, the magnitude of the mean error in C6 AOT-the difference between MODIS AOT and AERONET AOT-is 40% less than that in C5 AOT.