• Title/Summary/Keyword: aerodynamic distribution

Search Result 284, Processing Time 0.026 seconds

Pneumatic Separation on Separating Unit of a Combine Harvester (콤바인 선별실(選別室)의 기류선별(氣流選別)에 관한 연구(硏究))

  • Chung, C.J.;Nam, S.I.;Joo, B.C.
    • Journal of Biosystems Engineering
    • /
    • v.13 no.3
    • /
    • pp.32-43
    • /
    • 1988
  • This study was attempted to investigate the pneumatic separation on separating unit of a combine harvester. The aerodynamic characteristics of threshed materials were analyzed by experiments. The air velocity distribution within the separation chamber was measured for various speeds of the winnower and suction fans to find out the operational and design conditions of the separating unit which would serve for reducing the grain loss from chaff outlet. The results of study arc summarized as follows: 1. Based on the separation curve of threshed materials analyzed, it was shown that three different kind. of materials-kernels, straw chaff, and leaf chaff were as a whole able to be separated pneumatically, regardless of varieties. However, a small amount of the separation grain loss may be expected to occur if the complete separation between kernels and straw chaff would be undertaken because some portion of their separation curve were overlapping. 2. The analysis of air velocity distribution showed that the separation chamber may be divided into two regions, the discharging and separating. The air velocity of the discharging region was 5-15 m/s and that of the separating region 2-5 m/s. 3. The air movement of the separation chamber may be a turbulence flow, being its speed became greater as it moves from the left to the right section of the separation chamber. The equi-speed line. of air flow had a steep gradient in between the discharging and the separation regions. The air velocity in the discharging region was much higher than the terminal velocity of kernels, because of which those kernels appearing in the region could be possibly exhausted as the grain loss from the chaff outlet. 4. The motion trajectory of threshed material in the separating region was dominantly affected by the winnower fan, on the other hand, its motion in the discharging region was affected by suction fan. 5. The grain loss from the chaff outlet was affected greatly by the winnower fan and the trace of kernel movement. It was observed that the optimum working speed to give minimum grain loss from chaff outlet for the combine tested should be maintained at 950~1,150 rpm for the winnower fan and 1,850 rpm for the suction fan. 6. It was shown that a large portion of grain loss from chaff outlet may occur when the kernels may bump against a portion of separation chamber wall and those kernels thus scattered into the discharging region were sucked by the suction fan. It was accordingly recommended that a new design of the wall of separation chamber so as to bump down kernels may be necessary to reduce grain loss from the chaff outlet.

  • PDF

Condensation processes in transonic two-phase flows of saturated humid air using a small-disturbance model (미교란 모델을 이용한 포화 습공기 천음속 2상 유동에서의 응축현상)

  • Lee, Jang-Chang;Zvi Rusak
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.6
    • /
    • pp.23-29
    • /
    • 2003
  • Transonic two-phase flow of Saturated humid air, in which relative humidity is 100%, with various condensation processes around thin airfoils is investigated. The study uses an extended transonic small-disturbance(TSD) model of Rusak and Lee [11, 12] which includes effects of heat addition to the flow due to condensation. Two possible limit types of condensation processes are considered. In the nonequilibrium and homogeneous process, the condensate mass fraction is calculated according to classical nucleation and droplet growth rate models. In the equilibrium process, the condensate mass fraction is calculated by assuming an isentropic process. The flow and condensation equations are solved numerical1y by iterative computations. Results under same upstream conditions describe the flow structure, field of condensate, and pressure distribution on airfoil's surfaces. It is found that flow characteristics, such as position and strength of shock waves and airfoil’s pressure distribution, are different for the two condensation processes. Yet, in each case, heat addition as a result of condensation causes significant changes in flow behavior and affects the aerodynamic performance of airfoils.

Analysis of Quartz Content and Particle Size Distribution of Airborne Dust from Selected Foundry Operations (주물사업장 주공정별 발생하는 분진의 석영함유량 및 크기분포 연구)

  • Phee, Young Gyu;Roh, Young Man;Lee, Kwang Mook;Kim, Hyoung-Ah;Kim, Yong Woo;Won, Jeoung Il;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.7 no.2
    • /
    • pp.196-208
    • /
    • 1997
  • This study was performed to estimate quartz contents in the both bulk and airborne dust samples and to determine particle size distribution of airborne dust from the selected foundry operations. Total dust samples were collected by a 37mm cassette and respirable by a 10 mm nylon cyclone. Particle size distributions were determined by a Marple's 8-stage cascade impactor at the melting, molding, shakeout and finishing operations. The presence of elements in the dust samples were confirmed by the scanning electron microscopy equipped with the energy dispersive x-ray spectrometry. The quartz contents were estimated using the intensity of the absorption peak of quartz at 799 cm-l by the Fourie Transformed Infrared Spectroscopy (FTIR). The results were as follows: 1. The analysis of data from cascade Impactor showed bimodal distributions of particle size at the melting, molding and shakeout operations. Mass median aerodynamic diameters for the distributions determined by histogram were $0.48-1.65{\mu}m$ for small and $13.43-19.58{\mu}m$ for large modes. In the dust samples collected at the finishing operations, however, only a large mode of $18.89{\mu}m$ was found. 2. The percentages of total to respirable dust concentration calculated from the impactor data ranged from 42 % to 66 %. The average concentrations of respirable dust by cyclone were $0.85-1.28mg/m^3$ collected from the workers, and were $0.23-0.56mg/m^3$ from the areas surveyed. Dust concentrations of personal samples were statistically significantly higher than those of area samples. The highest dust concentration was obtained from the personal samples of the finishing operation. 3. The mean percentages of silicon and oxygen estimated by SEM-EDXA in the bulk samples ranged from 35.83 % to 36.02 % and from 39.93 %-41.64 %, respectively. 4. The average quartz contents estimated by FTIR in the respirable dust from personal samples ranged from 4.32 % to 5.36 % and 4.54 % to 4.70 % in the bulk samples. No statistical difference of quartz content was found between foundry operations. In this study, quartz content was quantified by FTIR. Although no statistically significant difference in quartz content between airborne and bulk, samples and between different foundry operations was found, it is recommended that quartz content in the individual sample of respirable dust be analyzed and the results be used either to select an applicable quartz limits or to calculate the exposure limit. Further studies, however, are needed to compare the results by FTIR and XRD since it is reported that the quartz content determined by FTIR is different from that by XRD.

  • PDF

Cumulative Distributions and Flow Structure of Two-Passage Shear Coaxial Injector with Various Gas Injection Ratio (2중 유로형 전단 동축 분사기의 기체 분사율에 따른 유동 및 입도분포)

  • Lee, Inchul;Kim, Dohun;Koo, Jaye
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.7
    • /
    • pp.675-682
    • /
    • 2013
  • To verify the effect of inner- and outer-stage gas jets, a shear coaxial injector was designed to analyze the axial velocity profile and breakup phenomenon with an increase in the measurement distance. When the measurement position was increased to Z/d=100, the axial flow showed a fully developed shape due to the momentum transfer, aerodynamic drag effect, and viscous mixing. An inner gas injection, which induces a higher momentum flux ratio near the nozzle, produces the greater shear force on atomization than an outer gas injection. Inner- and Outer-stage gas injection do not affect the mixing between the inner and outer gas flow below Z/d=5. The experiment results showed that the main effect of liquid jet breakup was governed by the gas jet of an inner stage. As the nozzle exit of the outer-stage was located far from the liquid column, shear force and turbulence breaking up of the liquid jets do not fully affect the liquid column. In the case of an inner-stage gas injection momentum flux ratio within 0.84, with the increase in the outer gas momentum flux ratio, the SMD decreases. However, at an inner-stage gas jet momentum flux ratio over 1.38, the SMD shows the similar distribution.

Thyroplasty for the Restoration of a Normal Voice (음성개선을 위한 갑상연골성형술)

  • 김기령;김광문;정명현;이원상;정승규
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1982.05a
    • /
    • pp.10.1-10
    • /
    • 1982
  • The use of phonosurgery in the recent development of laryngomicrosurgery has enabled the restoration of a normal voice in respect to functional laryngeal surgery which in Korea in the past limited to simple removal of benign laryngeal tumor such as laryngeal polyp or nodules and cordal injection of $Teflon^{{\circledR}}$ for the treatment of recurrent nerve paralysis under the vision of suspension laryngoscopy. Performance of phonosurgery for the treatment of cord paralysis, mutational dysphonia, vocal cord atrophy, hyperkinetic dysphonia and sulcus vocalis is a happy event in the view point of development of phonosurgery in Korea. In this aspect thyroplasty to change the position and physical characteristics of the cord outside the glottis instead of the direct handling of the vocal cord through direct endoscopy is popular. Among the 4 types of thyroplasty, classified by Insshiki(1974), type I thyroplasty(1ateral compression of vocal cord) and type IV thyroplasty(lengthening of vocal cord) were effective in the treatment of unilateral vocal cord paralysis. Advantages of this operation are the fine adjustment of the degree of lateral compression under local anesthesia according to the phonation of the patient during operation and avoidance of dyspnea and intralaryngeal hemorrhage due to the manipulation outside the internal perichondrium of the thyroid cartilage. We did 7 cases of thyroplasty for the treatment of unilateral vocal cord paralysis in the 7 months from September 1981 to March 1982. Before the operation aerodynamic study, psychoacoustical evaluation, stroboscopy and sound spectrographic analysis were done. Two months after the operation the above procedures were performed again. Results of preoperative and postoperative examination were compared and the following results were obtained. 1) In the aerodynamic study, maximum phonation time increased to 158% of the preoperative value and the phonation quotient and the mean flow rate decreased to 58% and 54% of preoperative values. 2) The degree of hoarseness improved in the psychoacoustical evaluation and the glottic chink during phonation was decreased in the stroboscopic examiantion. 3) In the sound spectrographic analysis, periodicity was much restored and noise distribution decreased especially in the high frequency area.

  • PDF

Characteristics of Size-segregated Mass Concentrations of Indoor Aerosol Particles in University Buildings (대학건물 실내 에어로졸입자의 입경별 질량농도 특성)

  • Suh, Jeong-Min;Wang, Bin;Jang, Seong-Ho;Park, Jeong-Ho;Choi, Kum-Chan
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.4
    • /
    • pp.453-461
    • /
    • 2014
  • Objective: Based on the fact that fine particles are more likely to produce negative influences on the health of occupants as well as the quality of indoor air compared to coarse particles, it is critical to determine concentrations of aerosol particles with different sizes. Thus, this study focused on the size distribution and concentrations of aerosol particles in university buildings. Method: Aerosol particles in indoor air were collected from four areas: corridors in buildings(In-CO), lecture rooms(In-RO), laboratories(In-LR), and a cafeteria(In-RE). Samples were also collected from outside for comparison between the concentrations of indoor and outdoor particles. For the collection of the samples, an eight stage non-viable cascade impactor was used. Result: The average concentration of $PM_{10}$ in the samples collected from indoor areas was $34.65-91.08{\mu}g/m^3$,and the average for $PM_{2.5}$ was $22.65-60.40{\mu}g/m^3$. The concentrations of the aerosol particles in the corridors, lecture rooms, and laboratories were relatively higher than the concentrations collected from other areas. Furthermore, in terms of mass median aerodynamic diameter(MMAD), the corridors and lecture rooms had higher numbers due to their characteristics, showing $2.36{\mu}m$ and $2.11{\mu}m$, respectively. Laboratories running an electrolysis experiment showed $1.58{\mu}m$, and the cafeteria with regular maintenance and ventilation had $1.96{\mu}m$. Conclusion: The results showed that the $PM_{10}$ concentrations of all samples did not exceed indoor air quality standards. However, the $PM_{2.5}$ concentration was over the standard and, in particular, the concentration of fine particles collected from the laboratories was relatively higher, which could be an issue for the occupants. Therefore, it is important to improve the quality of the indoor air in university buildings.

Aeroelastic Compatibility Substantiation of Aircraft External Stores Using the Dynamic Characteristic Data from Ground Vibration Test (지상진동시험 동특성 데이터를 활용한 항공기 외부장착물의 공력탄성학적 적합성 입증)

  • Lim, Hyun Tae;Kwon, Jae Ryong;Byun, Kwan Hwa;Kim, Hee Joong;Kim, Jae hoon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.4
    • /
    • pp.269-275
    • /
    • 2017
  • The aeroelastic stability of a fighter type aircraft can be severly affected by the store mass, aerodynamic characteristics, and store combinations. Hence, the stability for the all store configurations must be substantiated before the aircraft in service. For the aeroelastic analysis, the design data and information for the aircraft structure, mass distribution, control surface characteristics, and external shape etc. are required. This is the reason that the store compatibility substantiations by a third party are restricted. However, according to the change of operational environment or the improvement of avionic technology, a new external store is developed and it should be installed on an aircraft without the support from the original supplier. This paper describe the process to substantiate the aeroelastic compatibility between a new external store and an imported aircraft whose design data is not available to a third party operating the aircraft.

Short-term Effects of Ambient Air Pollution on Emergency Department Visits for Asthma: An Assessment of Effect Modification by Prior Allergic Disease History

  • Noh, Juhwan;Sohn, Jungwoo;Cho, Jaelim;Cho, Seong-Kyung;Choi, Yoon Jung;Kim, Changsoo;Shin, Dong Chun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.49 no.5
    • /
    • pp.329-341
    • /
    • 2016
  • Objectives: The goal of this study was to investigate the short-term effect of ambient air pollution on emergency department (ED) visits in Seoul for asthma according to patients' prior history of allergic diseases. Methods: Data on ED visits from 2005 to 2009 were obtained from the Health Insurance Review and Assessment Service. To evaluate the risk of ED visits for asthma related to ambient air pollutants (carbon monoxide [CO], nitrogen dioxide [$NO_2$], ozone [$O_3$], sulfur dioxide [$SO_2$], and particulate matter with an aerodynamic diameter <$10{\mu}m$ [$PM_{10}$]), a generalized additive model with a Poisson distribution was used; a single-lag model and a cumulative-effect model (average concentration over the previous 1-7 days) were also explored. The percent increase and 95% confidence interval (CI) were calculated for each interquartile range (IQR) increment in the concentration of each air pollutant. Subgroup analyses were done by age, gender, the presence of allergic disease, and season. Results: A total of 33 751 asthma attack cases were observed during the study period. The strongest association was a 9.6% increase (95% CI, 6.9% to 12.3%) in the risk of ED visits for asthma per IQR increase in $O_3$ concentration. IQR changes in $NO_2$ and $PM_{10}$ concentrations were also significantly associated with ED visits in the cumulative lag 7 model. Among patients with a prior history of allergic rhinitis or atopic dermatitis, the risk of ED visits for asthma per IQR increase in $PM_{10}$ concentration was higher (3.9%; 95% CI, 1.2% to 6.7%) than in patients with no such history. Conclusions: Ambient air pollutants were positively associated with ED visits for asthma, especially among subjects with a prior history of allergic rhinitis or atopic dermatitis.

A Study on the Characteristic of Airborne Lead Particle Size by Industry (업종별 공기중 납입자의 입경별 분포특성에 관한 조사 연구)

  • Park, Dong Wook;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.2
    • /
    • pp.160-171
    • /
    • 1995
  • The size characteristics of lead particle which is one of the important factors associated with absorption of lead were ignored in establishing lead standard. This study was conducted to investigate distribution of lead particles by operation of industry. Aerodynamic Mass Median Diameters (MMD) of airborne lead particles in the battery and litharge manufacturing industry were $14.1{\mu}m$ and $15.1{\mu}m$, respectively. There was no significant difference between those two values(p>0.05). However, the diameters in radiator manufacturing and secondary smelting industry were $1.3{\mu}m$, $4.9{\mu}m$, respectively. Those were significantly smaller than the particle sizes in other industries(p<0.05). Total lead concentrations in the secondary smelting industry were higher than those in the battery and litharge manufacturing industry. Total lead concentrations in other industries except radiator manufacturing industry exceeded the standard of $50{\mu}g/m^3$. Only radiator manufacturing industry indicated lead concentrations significantly lower than those in other industries(p<0.05). Concentrations of lead particles smaller than $1{\mu}m$ defined as respirable fraction by OSHA's CPA model assumption were $72.4{\mu}g/m^3$ in the secondary smelting industry, exceeding $50{\mu}g/m^3$. The relationship of concentrations between total lead and lead of particles smaller than $1{\mu}m$ was log Y = 0.46 logX + 0.06(n=119, $r^2=0.44$, p=0.0001). Relationship of respirable lead concentrations between OSHA and ACGIH was significantly detected in the litharge and battery manufacturing industry(p=0.0001), but was not significant in the radiator(p=0.2720) and secondary smelting manufacturing industry(p=0.2394). As MMDs of lead particles generated in industry were small, difference of respirable lead concentration between OSHA and ACGIH became smaller. There was a significant difference between concentrations respirable lead defined by two organizations such as OSHA and ACGIH in the battery and litharge manufacturing industry. Average concentration of respirable lead by ACGIH definition was 43.3 % of total lead in secondary smelting and 48.9 % in radiator manufacturing industry, and lower fractions were indicated in battery and litharge manufacturing industry. Relationships of total lead with IPM, TPM, and RPM were significant respectively(p=0.0001) and lead concentrations by particle size could be estimated using this relationship. Linear regression equation between total lead concentration(X) and ACGIH-RPM concentration(Y) was log Y = 0.76 log X - 0.40($r^2=0.89$, p=0.0001).

  • PDF

The Analysis of PM10 Concentration and Emission Contribution in the Major Cities of Korea (한반도 주요 대도시의 PM10 농도 특성 및 배출량과의 상관성 분석)

  • Kang, Minsung;Kim, Yoo-Keun;Kim, Taehee;Kang, Yoon-Hee;Jeong, Ju-Hee
    • Journal of Environmental Science International
    • /
    • v.25 no.8
    • /
    • pp.1065-1076
    • /
    • 2016
  • This study analyzes the $PM_{10}$ characteristics (particulate matter with aerodynamic diameter less than $10{\mu}m$), concentration, and emissions in eight large South Korean cities (Seoul, Incheon, Daejeon, Daegu, Gwangju, Ulsan, Busan, Jeju). The annual median of $PM_{10}$ concentration showed a decline of $0.02{\sim}1.97{\mu}g/m^3$ in the regions, except for Incheon, which recorded an annual $0.02{\mu}g/m^3$ increase. The monthly distribution levels were high in spring, winter, fall, and the summer, but were lower in summer for all regions except for Ulsan. These differences are thought to be due to the dust in spring and the cleaning effect of precipitation in summer. The variation in concentrations during the day (diurnal variation) showed that $PM_{10}$ levels were very high during the rush hour and that this was most extreme in the cities (10.00 and 18.00-21.00). The total annual $PM_{10}$ emissions analysis suggested that there had been a general decrease, except for Jeju. On-road mobile (OM) sources, which contributed a large proportion of the particulates in most regions, decreased, but fugitive dust (FD) sources increased in the remaining regions, except for Daegu. The correlation analysis between $PM_{10}$ concentrations and emissions showed that FD could be used as a valid, positive predictor of $PM_{10}$ emissions in Seoul (74.5% (p<0.05)), Dajeon (47.2% (p<0.05)), and Busan (59.1% (p<0.01)). Furthermore, industrial combustion (IC) was also a significant predictor in Incheon (61.7% (p<0.01)), and on-road mobile (OC) sources were a valid predictor in Daegu (24.8% (p<0.05)).