• 제목/요약/키워드: advanced wastewater treatment process

검색결과 237건 처리시간 0.028초

활성슬러지공정과 고도처리공정에 따른 하수처리수의 처리효율과 유기물 특성 (Treatment Efficiency and Organic Matter Characterization of Wastewater through Activated Sludge Process and Advanced Wastewater Treatment Process)

  • 홍지혜;손진식
    • 상하수도학회지
    • /
    • 제18권6호
    • /
    • pp.807-813
    • /
    • 2004
  • Wastewater was treated by two different treatment processes; activated sludge process and advanced wastewater treatment process (KNR process) using lab-scale experiment. Two treated wastewater showed good treatment efficiency of organic matter removal, up to 90% removal. Nitrogen and phosphorus were not effectively removed though activated sludge process, while KNR process showed good removal efficiency of nitrogen and phosphorus; 56% nitrogen removal and 95% phosphorus removal. KNR process showed better removal efficiency of organic matter, nitrogen, and phosphorus compared to activated sludge process. Organic matter characterization was tracked though measurement of UV scan, SUVA, and XAD fractionation. Treated wastewater showed higher SUVA value than wastewater influent, indicting less aromatic characteristic of organic matter. XAD fractionation showed hydrophilic fraction decreased though wastewater treatment, suggesting microbes preferentially digest hydrophilic and aliphatic molecules rather than hydrophobic and aromatic molecules of organic matter.

난분해성 산업폐수 처리를 위한 고도산화기술 (Advanced oxidation technologies for the treatment of nonbiodegradable industrial wastewater)

  • 김민식;이기명;이창하
    • 상하수도학회지
    • /
    • 제34권6호
    • /
    • pp.445-462
    • /
    • 2020
  • Industrial wastewater often contains a number of recalcitrant organic contaminants. These contaminants are hardly degradable by biological wastewater treatment processes, which requires a more powerful treatment method based on chemical oxidation. Advanced oxidation technology (AOT) has been extensively studied for the treatment of nonbiodegradable organics in water and wastewater. Among different AOTs developed up to date, ozonation and the Fenton process are the representative technologies that widely used in the field. Based on the traditional ozonation and the Fenton process, several modified processes have been also developed to accelerate the production of reactive radicals. This article reviews the chemistry of ozonation and the Fenton process as well as the cases of application of these two AOTs to industrial wastewater treatment. In addition, research needs to improve the cost efficiency of ozonation and the Fenton process were discussed.

산업폐수 중의 질소 성분의 제거를 위한 고도처리 공정의 응용 (Application of Advanced Treatment Process for Nitrogen Compounds Removal of Industrial Waste-water)

  • 방성훈;임은태;정귀택;박재희;박석환;김성준;박돈희
    • KSBB Journal
    • /
    • 제23권6호
    • /
    • pp.541-545
    • /
    • 2008
  • This paper was studied to research regarding the removal of contained nitrogen in industrial wastewater which uses the A2O4 advanced water treatment process. The field researches of two companies' wastewater occurred in each wastewater treatment site to apply the A2O4 process system, it was observed them for 20 days. As a result of the A2O4 system advanced wastewater process which applied an altitude control process obtained $10{\sim}76\;mg/L$, and 20 mg/L total nitrogen compound concentration in the two wastewater plants. In conclusion, it applied the A2O4 system in the two companies' wastewater system.

전기응집을 이용한 2차 유출수의 질소.인 제거 공정 연구 (Removal of nitrogen and phosphorus of the secondary effluent by electro-coagulation)

  • 한송희;장인성
    • 상하수도학회지
    • /
    • 제26권4호
    • /
    • pp.579-589
    • /
    • 2012
  • To reduce extensive energy costs of the internal recycling for the purpose of denitrification in the advanced wastewater treatment, a post-treatment process using an electro-coagulation to treat nitrate in the secondary effluents is evaluated in this study. Removals of phosphorus and organics in the secondary effluents by the electro-coagulation were also evaluated to propose an alternative advanced wastewatert treatment process. A series of experiments of the electro-coagulation were carried out with the following 4 different samples: synthetic solution containing nitrate only, synthetic solution containing nitrate as well as phosphorus, secondary effluents from activated sludge cultivated in laboratory, and secondary effluents from real wastewater treatment plants. Removals of nitrate and phosphorus in the synthetic solution were 30 and 97 % respectively, which verified the feasibility of the process. Removals of nitrate, phosphorus and COD in the secondary effluents from the cultivated sludge in laboratory were 49, 90 and 19 % respectively. Removal efficiency of the total nitrogen, nitrrate, phosphorus and COD in the secondary effluent from real wastewater treatment plant were 50, 61, 98 and 80 % respectively. The removal of the total nitrogen was less than the nitrate as expected, which is due to the formation of ammonia nitrogen in the cathode. But the proposed scheme could be an energy saving and alternative process for the advanced wastewater treatment if further studies for the process optimization are carried out.

고급산화공정을 이용한 염료폐수의 처리기술 연구 (A Study on the Dye Wastewater Treatment by Advanced Oxidation Process)

  • 강태희;오병수;박세준;강민구;김종성;강준원
    • 한국물환경학회지
    • /
    • 제21권3호
    • /
    • pp.267-273
    • /
    • 2005
  • Dye wastewater generally contains strong color and non-biodegradable materials. Therefore, the conventional wastewater treatment plant can hardly meet the regulation of wastewater effluent water. In this study, a pilot plant of the conventional process followed by advanced oxidation process (AOP), was set up to treat the dying wastewater. The treatment efficiencies on the various candidate processes, such as ozone alone, UV alone, ozone/UV, $ozone/H_2O_2$, $H_2O_2/UV$ and $ozone/UV/H_2O_2$, were investigated in the various ozone and $H_2O_2$ doses. As the results, the $ozone/H_2O_2$ process, among the tested processes, showed the highest efficiency for removing color and $COD_{Cr}$. For color removal, the ozone alone process was enough without combining UV or $H_2O_2$. No significantly enhanced efficiency for removing color and $COD_{Cr}$ by UV irradiation was observed because of the very low transmittance of UV light in dye wastewater.

산업폐수 재이용을 위한 고급산화공정 시스템 연구 (A Study of Advanced Oxidation Process for Reuse of Industrial Wastewater)

  • 김성준;김명희;원찬희;황정석;이길용
    • 한국물환경학회지
    • /
    • 제26권4호
    • /
    • pp.580-584
    • /
    • 2010
  • As water becomes more scarce around the world the reuse of treated wastewater is being recenlty considered as indispensible trend we need to follow. Especially, industrial area consuming large amount of water has been encouraged to reuse the treated wastewater to secure sufficient water for the production of merchandise. In this study, a study of advanced oxidation process for treatment of industrial wastewater. The treatment performance of UV and ozoznation and five types advanced oxidation processes such as UV/AC, UV/Catalyst, $O_3$/Catalyst, UV/$O_3$/Catalyst was experimentally investigated for reuse of industrial wastewater. The removal efficiency of $COD_{Cr}$, color were relatively evaluated in each treatment unit simulated outflow water of wastewater treatment area. UV/$O_3$/Catalyst process showed the highest $COD_{Cr}$ remaval and color remaval among proposed oxidation process.

펜톤산화와 오존산화 조합에 따른 염색폐수의 유기물질 및 색도 처리효율 비교 평가에 관한 연구 (Eveluation of Comparable Removal Efficiency of Organics and Color for the Dyeing Wastewater by Fenton Oxidation and Ozonation)

  • 김선희;이상호
    • 상하수도학회지
    • /
    • 제18권6호
    • /
    • pp.778-784
    • /
    • 2004
  • Dyeing wastewater contains recalcitrant organics which can not be easily treated by conventional biological treatment. Therefore it has to be treated by other advanced oxidation process in order to remove COD and Color more efficiently. Fenton oxidation process is one of the most commonly applied processes in removal of COD and color for the dyeing wastewater. However it increase the treatment cost and the production of sludge by the use of the excessive chemical reagent. Ozonation is not suitable in Single treatment process because it is not effective in organics removal compared with Color removal. The purpose of this research in order to evaluate the comparable removal efficiency of COD and color by the combination of advanced oxidation processes for the dyeing wastewater. The sequential treatment processes of Fenton process and ozonation was more effective to remove organics and color than ozonation and Fenton process. The result of Fenton process for the pretreatment presented as the 81% removal of organics whereas ozonation process for the pretreatent presented as the 22.1% removal of organics. The removal of colour was higher as 81.3% for the ozonation as the pretreatment than 77.7% for the Fenton process as the pretreatment.

The applications of ozone-based advanced oxidation processes for wastewater treatment: A review

  • Hussain, Mujtaba;Mahtab, Mohd Salim;Farooqi, Izharul Haq
    • Advances in environmental research
    • /
    • 제9권3호
    • /
    • pp.191-214
    • /
    • 2020
  • The rise in population and industrialization accounts for the generation of a huge amount of wastewaters. The treatment of this wastewater is obligatory to safeguard the environment and various life forms. Conventional methods for high strength wastewater treatment coming out to be ineffective. Advanced oxidation processes (AOPs) for such wastewater treatment proved to be very effective particularly for the removal of various refractory compounds present in the wastewater. Ozone based AOPs with its high oxidizing power and excellent disinfectant properties is considered to be an attractive choice for the elimination of a large spectrum of refractory compounds. Furthermore, it enhances the biodegradability of wastewaters after treatment which favors subsequent biological treatments. In this review, a detailed overview of the AOPs (like the Fenton process, photocatalysis, Electrochemical oxidation, wet air oxidation, and Supercritical water oxidation process) has been discussed explicitly focusing on ozone-based AOPs (like O3, O3/H2O2, O3/UV, Ozone/Activated carbon process, Ozone/Ultrasound process, O3/UV/H2O2 process). This review also comprises the involved mechanisms and applications of various ozone-based AOPs for effective municipal/industrial wastewaters and landfill leachate treatment. Process limitations and rough economical analysis were also introduced. The conclusive remarks with future research directions also underlined. It was found that ozonation in combination with other effective AOPs and biological methods enhances treatment efficacies. This review will serve as a reference document for the researchers working in the AOPs field particularly focusing on ozone-based AOPs for wastewater treatment and management systems.

소화탈리액 대상 오존 전처리와 Ultra Violet-Advanced Oxidation Process 연계 처리를 통한 유기물질 지표 개선 (Improvement of Organic Substances Indicators by Linked Ultra Violet-Advanced Oxidation Process After Ozonation for Anaerobic Digested Wastewater)

  • 이재엽;제스민아터;김일호
    • 상하수도학회지
    • /
    • 제37권5호
    • /
    • pp.253-259
    • /
    • 2023
  • Bioreactors are devices used by sewage treatment plants to process sewage and which produce active sludge, and sediments separated by solid-liquid are treated in anaerobic digestion tanks. In anaerobic digestion tanks, the volume of active sludge deposits is reduced and biogas is produced. After dehydrating the digestive sludge generated after anaerobic digestion, anaerobic digested wastewater, which features a high concentration of organic matters, is generated. In this study, the decomposition of organic carbon and nitrogen was studied by advanced oxidation process. Ozone-microbubble flotation process was used for oxidation pretreatment. During ozonation, the TOC decreased by 11.6%. After ozone treatment, the TOC decreased and the removal rate reached 80.4% as a result of the Ultra Violet-Advanced Oxidation Process (UV-AOP). The results with regard to organic substances before and after treatment differed depending on the organic carbon index, such as CODMn, CODCr, and TOC. Those indexes did not change significantly in ozone treatment, but decreased significantly after the UV-AOP process as the linkage treatment, and were removed by up to 39.1%, 15.2%, and 80.4%, respectively. It was confirmed that biodegradability was improved according to the ratio of CODMn to TOC. As for the nitrogen component, the ammonia nitrogen component showed a level of 3.2×102 mg/L or more, and the content was maintained at 80% even after treatment. Since most of the contaminants are removed from the treated water and its transparency is high, this water can be utilized as a resource that contains high concentrations of nitrogen.

하수처리장의 고도처리 upgrading 설계와 공정 최적화를 위한 다변량 통계분석 (Design of a Wastewater Treatment Plant Upgrading to Advanced Nutrient Removal Treatment Using Modeling Methodology and Multivariate Statistical Analysis for Process Optimization)

  • 김민정;김민한;김용수;유창규
    • Korean Chemical Engineering Research
    • /
    • 제48권5호
    • /
    • pp.589-597
    • /
    • 2010
  • 하수처리 시스템에서의 생물학적 영양염류 기준이 강화됨에 따라, 표준활성슬러지공법으로 운전 중인 하수처리장의 고도처리 공법으로의 개보수 필요성이 증가하고 있다. 그러나 실제 하수처리 시스템에서의 다양한 유입조건 및 운전조건의 복잡한 반응 구성으로 인해 실험을 통하여 개보수된 고도처리공법의 최적조건을 찾는 것은 쉽지 않은 일이며, 이는 많은 시간과 비용을 소모하여 비효율적이다. 따라서 본 연구에서는 활성슬러지공정모델(ASMs)을 기반으로 한 하수처리장의 모델링 및 시뮬레이션 기법을 통하여 하수처리장의 고도처리공법으로의 upgrading 설계를 수행하며, 이를 통계적이며 체계적으로 접근하기 위해 반응표면분석법(Response surface method)을 통한 고도처리공법의 설계 최적화를 수행하였다. 또한 실규모 하수처리장에서의 운전 최적화를 위해서는 하수처리의 동력학적 매개변수에 대한 정확한 분석이 수행되어야 한다. 본 연구에서는 다변량 통계분석 기법인 부분최소승자법(PLS)을 통하여 하수처리 시스템의 동력학적 매개변수 간의 상관관계를 파악하며, 고도처리공법 하수처리장의 운전 결과에 가장 큰 영향을 미치는 매개변수를 도출하였다. 본 연구를 통해 하수처리장의 고도처리공법 upgrading 설계 및 운전 최적화를 위한 방법론을 제시하였으며, 이를 통하여 설계시간 및 경비 절감 등 고도처리공법으로의 고효율적인 개보수가 가능할 것으로 예상된다.