• 제목/요약/키워드: advanced placement

검색결과 156건 처리시간 0.023초

Product-Story Congruence and Actor Attractiveness in Product Placements in Television Drama

  • Cheon, Minhye;Ahn, Yena;Mo, Ju Hee;Park, Jee-Sun
    • 패션비즈니스
    • /
    • 제20권3호
    • /
    • pp.104-118
    • /
    • 2016
  • As more consumers avoid ads aided by advanced technologies that conveniently block ads, traditional advertising is becoming less effective than ever before. Product placements are increasingly executed to unobtrusively expose products and brands to consumers while they watch media programs. The current study attempts to enhance our understanding of the factors that affect consumer attitude towards the brands placed in TV dramas. In particular, this study examines whether the attractiveness of actors and the congruency between the products placed and the story of the TV drama influence consumer attitudes towards the TV drama and the brand. A total of 211 male consumers in their 20s and 30s were used for data analyses. Structural equation modelling revealed that the product-story congruence had a positive impact on consumer attitude towards the TV drama as well as their attitude towards the brand. Actor attractiveness (in terms of similarity and likability) positively influenced consumer attitude towards the brand. Only the perceived likability dimension of actor attractiveness was found to affect consumer attitude towards the TV drama.

Immediate loading on mandibular edentulous patient with SFI Bar$^{(R)}$ overdenture

  • Kim, Ha-Young;Kim, Jin-Young-Ryan;Qadeer, Sarah;Jeong, Chang-Mo;Shin, Sang-Wan;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권1호
    • /
    • pp.47-50
    • /
    • 2011
  • Despite the greater retention and low maintenance of bar attachment system, the longer clinical time and increased number of visits were the assignments to overcome in bar attachment system. This case report describes SFI-Bar$^{(R)}$ (Cendres et Me$\'{e}$taux, Biel/Bienne, Switzerland) to be solve those problems. A 65-year-old female, who had severely absorbed mandible, hoped to wear a stable mandibular denture without pain. As soon as two implants were placed on mandible, a tube bar was connected to two adaptors connected to each implant. The length of the tube bar was adjusted considering inter implant distance, and reconnected to the adaptors. Finally a female part was seated beneath the denture. This case report showed that a satisfactory clinical result was achieved by delivering bar overdenture immediately after implant placement without laboratory procedure.

User Experience Validation Using the Honeycomb Model in the Requirements Development Stage

  • Kim, Neung-Hoe
    • International journal of advanced smart convergence
    • /
    • 제9권3호
    • /
    • pp.227-231
    • /
    • 2020
  • Recently, the importance of user experience (UX) has been rapidly increasing. Its utilization is emphasized for development of systems, products, and services. User experience is widely used across industries including services, products, processes, society, and culture. Therefore, if it is unsatisfactory, it is likely to have a direct negative impact on the corresponding system, product, or service. The failure to analyze user experience causes significant damage to the project, which may lead to its failure or redevelopment; it is hence necessary to prioritize the verification of UX in the earliest stages of development. The requirements development stage, which is a preceding stage, is an appropriate stage for the verification of user experience because the identification of user needs is completed and prototypes can be implemented. In this paper, we proposed a systematic requirements development stage; it adds user experience verification activities to the requirements development stage, using the Honeycomb model, which is a widely used tool for verifying the overall UX. User experience verification was added to the existing requirements development activities, which consisted of three steps: model definition and requirements placement, discussions between external and internal stakeholders, and review by internal stakeholders. By easily validating the user experience through this systematic requirements development stage, we expect to minimize the damage to the project due to the failure of the user experience analysis and increase the possibility of success.

The relationship between initial implant stability quotient values and bone -to-implant contact ratio in the rabbit tibia

  • Park, In-Phill;Kim, Seong-Kyun;Lee, Shin-Jae;Lee, Joo-Hee
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권2호
    • /
    • pp.76-80
    • /
    • 2011
  • PURPOSE. Implant stability quotient (ISQ) values have been supposed to predict implant stability. However, the relationship between ISQ values and bone-to-implant contact ratio (BIC%) which is one of the predictors of implant stability is still unclear. The aim of the present study was to evaluate initial ISQ values in relation to BIC% using rabbit model. MATERIALS AND METHODS. Four New Zealand white rabbits received a total of 16 implants in their tibia. Immediately after implant placement ISQ values were assessed. The measurements were repeated at the time of sacrifice of the rabbits after 4 weeks. Peri-implant bone regeneration was assessed histomorphometrically by measuring BIC% and bone volume to total volume values (bone volume %). The relationships between ISQ values and the histomorphometric output were assessed, and then, the osseointegration prediction model via the initial ISQ values was processed. RESULTS. Initial ISQ values showed significant correlation with the BIC%. The bone volume % did not show any significant association with the ISQ values. CONCLUSION. In the limitation of this study, resonance frequency analysis is a useful clinical method to predict the BIC% values and examine the implant stability.

Evaluation of dental panoramic radiographic findings in edentulous jaws: A retrospective study of 743 patients "Radiographic features in edentulous jaws"

  • Kose, Taha Emre;Demirtas, Nihat;Karabas, Hulya Cakir;Ozcan, Ilknur
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권5호
    • /
    • pp.380-385
    • /
    • 2015
  • PURPOSE. The aim of this study was to determine the frequency of significant panoramic radiographic findings and eventual treatment requirements before conventional or implant supported prosthetic treatment in asymptomatic edentulous patients. MATERIALS AND METHODS. A total of 743 asymptomatic edentulous patients were retrospectively evaluated using a digital panoramic system. We analyzed the radiographic findings, including impacted teeth, retained root fragments, foreign bodies, severe atrophy of the posterior maxillary alveolar bone, mucous retention cysts, soft tissue calcifications and radiopaque-radiolucent conditions. RESULTS. Four-hundred-eighty-seven (65.6%) patients had no radiographic finding. A total of 331 radiographic findings were detected in 256 (34%) patients. In 52.9% (n=175) of these conditions, surgical treatment was required before application of implant-supported fixed prosthesis. However, before application of conventional removable prosthesis surgical treatment was required for 6% (n=20) of these conditions. CONCLUSION. The edentulous patients who will have implant placement for implant-supported fixed prosthesis can frequently require additional surgical procedures to eliminate pathological conditions.

Numerical analysis of a plain-fin type heat exchanger with two tubes in a crevice-type heat pipe

  • Kim, Eun-Pil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제40권8호
    • /
    • pp.686-691
    • /
    • 2016
  • This paper employs numerical tools to obtain an optimal thermal design of a heat exchanger with plain-fins. This heat exchanger is located at the condensing section of a crevice-type heat pipe. The plain-fins in the heat exchanger are radically mounted to two tubes in the condensing section. To obtain the optimal design parameters, a computational fluid dynamics technique is introduced and applied to different placement configurations in a system module. Owing to its effects on the heat pipe performance, the temperature difference between the tube surfaces and ambient air is investigated in detail. A greater heat dissipation rate occurs when the plain-fin offsets change from 2 to 3 mm. When this temperature difference is ${\Delta}T=70^{\circ}C$, the upper part of the plain-fins undergoes an accumulation of heat. At below $70^{\circ}C$, the dissipation of heat is accepted. A rectangular plain-fin geometry with varying widths and heights does not have a significant impact on the heat dissipation through-out the overall system. In addition, the temperature distributions between different plain-fin pitches show an equal profile even with different fin pitches.

사각채널에 설치된 배플이 열전달과 마찰계수에 미치는 효과 (Effects of Baffles on Heat Transfer and Friction Factors in a Rectangular Channel)

  • 안수환;강호근;배성택;송민호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권6호
    • /
    • pp.693-701
    • /
    • 2006
  • The present work investigates the local heat transfer characteristics and the associated frictional loss in a rectangular channel with inclined solid and perforated baffles to obtain the basic design data for gas turbine. Five different geometries of baffles such as 1) solid (without hole), 2) three holes, 3) six holes, 4) nine holes, 5) twelve holes were covered. A combination of two baffles of same overall size is used. The flow Reynolds number is ranged from 28,900 to 70,100. The placement of baffles augments the overall heat transfer greatly by combining both jet impingement and the boundary layer separation. The present results show that the average Nusselt number distribution is strongly dependent on number of holes in the baffle plates, i.e., the average Nusselt number increases with increasing number of holes. The friction factor decreases also with increasing the number of holes. however. its value increases with increasing the Reynolds number.

초·중 통합학교의 공간 구성 방향에 관한 연구 - 일본 의무학교 운영 사례를 중심으로 - (A Study on the Space Composition of lementary·Middle integrated school - Focusing on the Case of Japanese Integrated Schools -)

  • 이재림
    • 교육녹색환경연구
    • /
    • 제18권4호
    • /
    • pp.21-32
    • /
    • 2019
  • 본 연구는 초·중 통합학교의 공간 구성 방향을 제시하고자 일본의 초·중 통합학교 형태인 의무학교 사례를 중심으로 공간 배치 특성을 분석하였다. 이를 통해 초·중학교 발달단계별 학급교실의 공간 구성과 배치 특성을 도출하였고, 초·중 통합 활용전용 공간과 공동 활용 교과교실을 도출하였다. 또한 초·중학교 급별 학년별 교과교실 연계 특성을 분석하여 바람직한 교과교실 배치 방안을 도출함으로써 국내 초·중 통합학교 공간 배치 구성 방향에 대한 기본 방향을 제시하였다.

Superficial Keratectomy in a Standing Horse with Advanced Corneolimbal Squamous Cell Carcinoma

  • Ji, Dong-Beom;Choi, Eunsang;Ben-Shlomo, Gil;Kim, Ah-Young;Jeong, Kyu-Shik;Jeong, Manbok
    • 한국임상수의학회지
    • /
    • 제35권4호
    • /
    • pp.161-165
    • /
    • 2018
  • A 12-year-old gelding Warmblood Horse was presented with a corneolimbal mass in the right eye (OD) of 6 months duration. Clinical signs included ocular discomfort, persistent mucoid ocular discharge, and conjunctival hyperemia. The mass was excised by superficial keratectomy under sedation in a standing position, followed by a topical application of 0.04% mitomycin C (MMC), and a placement of a conjunctival advancement graft. The histopathological diagnosis was squamous cell carcinoma. One month after surgery, recurrence of the mass was suspected upon examination of the eye. Topical MMC and 5-fluorouracil followed by cryotherapy were applied as adjunctive therapies after debulking of the mass. The surgical site healed without complications and with a cosmetically acceptable result. No recurrence of the mass was noted four years following the second procedure.

Clinical outcomes of rigid and non-rigid telescopic double-crown-retained removable dental prostheses: An analytical review

  • Seo, Jeong-Gyo;Cho, Jin-Hyun
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권1호
    • /
    • pp.38-48
    • /
    • 2020
  • PURPOSE. The objective of this literature review was to analyze the cumulative survival rates (CSRs) of rigid and non-rigid double-crown-retained removable dental prostheses. MATERIALS AND METHODS. Screening of the literature published from January 1995 to December 2019 was performed by using electronic data base (Pubmed) and manual search. The CSRs of rigid and non-rigid double crown removable dental prostheses were investigated. RESULTS. A total of 403 articles were reviewed and 56 relevant articles of them were selected. Subsequently, 25 articles were included for data extraction. These articles were classified according to rigid and non-rigid type double crowns and further subdivided into teeth, implants, and teeth-implant combination types. The CSRs of rigid type double crown ranged from 68.9% to 95.1% of 5 to 10 years in tooth abutments, 94.02% to 100% over a 3-year mean observation periods in implant abutments, and 81.8% to 97.6% in tooth-implant combination. Non-rigid type double crowns had various CSR ranges from 34% to 94% maximum during 10 years observation in teeth abutment. The CSRs of non-rigid type had over 98% in implant abutments, and ranged from 85% to 100% in tooth-implant combination. CONCLUSION. The CSRs of double crowns varies according to types. With accurate evaluation of the remaining teeth and plan of the strategic implant placement, it could be successful treatment alternatives for partially or completely edentulous patients.