• Title/Summary/Keyword: advanced placement

Search Result 153, Processing Time 0.023 seconds

A Study on Global Field Placement Model co-working with Local Partner University: Based on Kumoh Institute of Technology Case Study (외국대학과 연계한 글로벌 현장실습의 모형에 대한 연구: 금오공과대학교 사례를 중심으로)

  • Lee, Seok-moon;Jeong, Yeon-koo
    • Journal of Practical Engineering Education
    • /
    • v.8 no.2
    • /
    • pp.129-136
    • /
    • 2016
  • In addition to the quantitative growth of domestic field placement, there is a growing interest in global field placement and participation of government and universities is increasing. The global field experience of university students provides students with advanced skills and experience of overseas companies as well as opportunities to acquire foreign language ability and global culture suitable for industrial needs that require global competence. Students can cultivate global mind and major practical skills so that it has the advantage of linking to overseas employment. In order to be successful global field placement, the university has to promote to participate in the company including the curriculum related to the student's major and provide comprehensive support including student safety, but the resources of the university are only limited. In this paper, we propose a method to activate global field placement in cooperation with local partner universities based on Kumoh Institute of Technology case study.

Improved performance of multi tone masks by advanced compensation methods

  • Ekberg, Peter;Sydow, Axel Von
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.520-523
    • /
    • 2009
  • The drive towards lowering costs and increasing frame rates results in new panel designs and thereby new photomasks designs. One common way to reduce cost is to reduce the number of production steps. For this multi tone photomasks (MTM) are needed. MTMs contain more information and increases photomask placement requirements. Increasing frame rates lead to shrinking geometries. The combination of HTM and shrinking geometries drastically increases the requirements imposed on the pattern generators used to print the photomasks. New methods are therefore needed to enable future photomask manufacturing. This paper introduces three advanced image quality enhancing methods.

  • PDF

A Study on Robust Optimal Sensor Placement for Real-time Monitoring of Containment Buildings in Nuclear Power Plants (원전 격납 건물의 실시간 모니터링을 위한 강건한 최적 센서배치 연구)

  • Chanwoo Lee;Youjin Kim;Hyung-jo Jung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.36 no.3
    • /
    • pp.155-163
    • /
    • 2023
  • Real-time monitoring technology is critical for ensuring the safety and reliability of nuclear power plant structures. However, the current seismic monitoring system has limited system identification capabilities such as modal parameter estimation. To obtain global behavior data and dynamic characteristics, multiple sensors must be optimally placed. Although several studies on optimal sensor placement have been conducted, they have primarily focused on civil and mechanical structures. Nuclear power plant structures require robust signals, even at low signal-to-noise ratios, and the robustness of each mode must be assessed separately. This is because the mode contributions of nuclear power plant containment buildings are concentrated in low-order modes. Therefore, this study proposes an optimal sensor placement methodology that can evaluate robustness against noise and the effects of each mode. Indicators, such as auto modal assurance criterion (MAC), cross MAC, and mode shape distribution by node were analyzed, and the suitability of the methodology was verified through numerical analysis.

P&R Porting & Test-chip implementation Using Standard Cell Libraries (표준 셀 라이브러리 P&R 포팅과 테스트 칩의 설계)

  • Lim, Ho-Min;Kim, Nam-Sub;Kim, Jin-Sang;Cho, Won-Kyung
    • Journal of Advanced Navigation Technology
    • /
    • v.7 no.2
    • /
    • pp.206-210
    • /
    • 2003
  • In this paper, we design standard cell libraries using the 0.18um deep submircom CMOS process, and port them into a P&R (Placement and Routing) CAD tool. A simple test chip has been designed in order to verify the functionalities of the 0.18um standard cell libraries whose technical process was provided by Anam semiconductor. Through these experiments, we have found that the new 0.18um CMOS process can be successfully applied to automatic digital system design.

  • PDF

Opposition Based Differential Evolution Algorithm for Capacitor Placement on Radial Distribution System

  • Muthukumar, R.;Thanushkodi, K.
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.45-51
    • /
    • 2014
  • Distribution system is a critical link between customer and utility. The control of power loss is the main factor which decides the performance of the distribution system. There are two methods such as (i) distribution system reconfiguration and (ii) inclusion of capacitor banks, used for controlling the real power loss. Considering the improvement in voltage profile with the power loss reduction, later method produces better performance than former method. This paper presents an advanced evolutionary algorithm for capacitor inclusion for loss reduction. The conventional sensitivity analysis is used to find the optimal location for the capacitors. In order to achieve a better approximation for the current candidate solution, Opposition based Differential Evolution (ODE) is introduced. The effectiveness of the proposed technique is validated through 10, 33, 34 and85-bus radial distribution systems.

Three-dimensional finite element analysis of buccally cantilevered implant-supported prostheses in a severely resorbed mandible

  • Alom, Ghaith;Kwon, Ho-Beom;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.1
    • /
    • pp.12-23
    • /
    • 2021
  • Purpose. The aim of the study was to compare the lingualized implant placement creating a buccal cantilever with prosthetic-driven implant placement exhibiting excessive crown-to-implant ratio. Materials and Methods. Based on patient's CT scan data, two finite element models were created. Both models were composed of the severely resorbed posterior mandible with first premolar and second molar and missing second premolar and first molar, a two-unit prosthesis supported by two implants. The differences were in implants position and crown-to-implant ratio; lingualized implants creating lingually overcontoured prosthesis (Model CP2) and prosthetic-driven implants creating an excessive crown-to-implant ratio (Model PD2). A screw preload of 466.4 N and a buccal occlusal load of 262 N were applied. The contacts between the implant components were set to a frictional contact with a friction coefficient of 0.3. The maximum von Mises stress and strain and maximum equivalent plastic strain were analyzed and compared, as well as volumes of the materials under specified stress and strain ranges. Results. The results revealed that the highest maximum von Mises stress in each model was 1091 MPa for CP2 and 1085 MPa for PD2. In the cortical bone, CP2 showed a lower peak stress and a similar peak strain. Besides, volume calculation confirmed that CP2 presented lower volumes undergoing stress and strain. The stresses in implant components were slightly lower in value in PD2. However, CP2 exhibited a noticeably higher plastic strain. CONCLUSION. Prosthetic-driven implant placement might biomechanically be more advantageous than bone quantity-based implant placement that creates a buccal cantilever.

Effect of rhPMP-2 coated implants on alveolar ridge augmentation in dogs (성견에서 골형성단백질이 코팅된 임플란트가 치조골 증대에 미치는 영향)

  • Park, Chan-Kyung;Kim, Jong-Eun;Shin, Ju-Hee;Ryu, Jae-Jun;Huh, Jung-Bo;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.3
    • /
    • pp.202-208
    • /
    • 2010
  • Purpose: This study was aimed to evaluate the effect of rhPMP-2 coated implants on alveolar ridge augmentation in dogs. Materials and methods: Six Beagle dogs were used in this study. Six 8.0 mm long anodized surface titanium implants were placed 5 mm into the mandibular alveolar ridge following 6 month of healing period after extraction. Each animal received three implants coated with rhBMP-2 and three uncoated control implants using the randomized split-mouth design. Radiographic examinations were undertaken immediately at implant placement (baseline), at weeks 4 and 8 after implant placement. The amount of bone augmentation was evaluated by measuring the distance from the uppermost point of the coverscrew to the marginal bone. Implant Stability Quotient (ISQ) values were measured immediately at implant placement and 8 weeks after implant placement. For the statistical analysis, Man-Whitney ranksum test and Wilcoxon signed rank test of SPSS 12.0 software were used (P=.05). Results: The BMP group exhibited radiographic vertical bone augmentation about $0.6{\pm}0.7$ mm at 8 weeks later while controls showed bone loss about $0.4{\pm}0.6$ mm. There was significant difference among the rhBMP-2 group and controls in bone level change (P<.05). The ISQ values were significantly higher in the BMP-2 group than the control group at 8 weeks later (P<.05), while there was no significant difference at surgery. Conclusion: Within the limitation of this study, the rhBMP-2 coated on anodized implant could stimulate vertical alveolar bone augmentation, which may increase implant stability significantly on completely healed alveolar ridge.

Paresthesia After Inferior Alveolar Nerve Block and Infiltration Anesthesia for Implant Surgery on Mandibular Left First Premolar (하악 좌측 제1소구치 부위의 임플란트 식립을 위한 하치조신경 국소마취 후 발생한 Paresthesia)

  • Jo, Ji-Hun;Lee, Kang-Hee;Pang, Nam-Sim;Park, Wonse;Kim, Kee-Deog;Jung, Bock-Young
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.13 no.2
    • /
    • pp.39-44
    • /
    • 2013
  • Most of the dental treatments have been routinely performed under the local anesthesia and the effectiveness has also been proved safe. However, even not frequently dentists face some complications associated with the local anesthesia. In this report, the experience of the paresthesia after mental nerve block anesthesia for an implant placement of the mandibular premolar was presented to raise awareness of the complications related with local anesthetic procedure and to discuss about the causes, the proper treatments and the preventive approach of the paresthesia.

Students' Perception of Advanced Placement Program between S&T Institute and Science Highschool (과학고등학교 공동AP(대학과목선이수제)에 대한 학생인식)

  • Lee, Young Ju;Kim, Youngmin;Lee, Bumjin;Shin, Yoonjoo
    • Journal of Gifted/Talented Education
    • /
    • v.26 no.2
    • /
    • pp.405-421
    • /
    • 2016
  • The purpose of this study was to investigate students' perception of Advanced Placement Program. Participations of this study were 1144 students from 14 science high schools. The results showed as follows. First, students perceived positively regarding AP program and were willing to take AP courses because of interesting and challenging in academic area which is provided by AP courses. Secondly, many students would like to take AP courses in Differential and Integral Calculus 1, General Physics I, General Chemistry I and General Biology. Also, they would like to take AP courses in first term as a mandatory subjects. Third, responses perceived that AP courses were challenging, difficult, and of high quality. Finally, students perceived the benefit of AP courses in earing college credit. However, 35% of responses wished to receive an exemption for all AP courses. Also, they wished to have dual-major or participate in students exchange program as a benefit of AP program. Implications of the study were discussed in depth based on the results.

A lateral approach to the maxillary sinus for simultaneous extraction of an ankylosed maxillary molar and sinus graft: a case report

  • Hwang, Jae-Ho;Choi, Hee-Seung;Kim, Kee-Deog;Doh, Re-Mee;Park, Won-Se
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.38 no.2
    • /
    • pp.110-115
    • /
    • 2012
  • Ankylosed tooth is defined as 'the discontinuance of normal passive tooth eruption without any mechanical barrier'. Ankylosed tooth treatment is a challenge to dental clinicians. In treatment of maxillary molar ankylosis cases there are risks of oro-antral fistula, displacement of root fragments into the maxillary sinus, as well as the necessity for providing additional sinus bone augmentation for future implant placement. In this study, we suggested a new technique using a piezoelectric device and a lateral side approach to the maxillary sinus leading to the simultaneous removal of the ankylosed maxillary molar and sinus grafting for the purpose of implant site development.