• Title/Summary/Keyword: advanced control room

Search Result 124, Processing Time 0.032 seconds

Training Requirements for Control Room Operators of an Advanced Nuclear Power Plant

  • Park, Hong Joon;Park, Geun Ok;Kim, Sa Kil;Byun, Seong Nam
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.1
    • /
    • pp.107-115
    • /
    • 2013
  • Objective: The aim of this study is to identify the training requirements of new nuclear power plant by a comprehensive literature review. Background: The design of instrumental and control systems for New NPP is applied fully digitalized systems. For example, soft-control, large display panels(LDP), and an advanced alarm system were applied to the APR-1400 or SMART. Method: The NUREG-0711 and international guideline of training program was analyzed from the following four phases of SAT(Systemic Approach to Training): Analysis, Design, Development, Implementation and Evaluation. Results: To identify the requirement of training program, 'Feedback' phase was considered and each phase of SAT was classified. Conclusion: A more systematic requirement of training program is needed which considers the computerized system was applied to the new NPP. Application: The results of the publishing can be useful for standardization of the systematic training program for the operators of NPP.

A Study on the Automatic Sensing Device for Gas Leakage of Cooling Plate Using the Microprocessor System

  • Wang, Jee-Seok;Yoon, Hee-Jong;Kang, Ki-Seong;Kim, Jong-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.3
    • /
    • pp.329-334
    • /
    • 2011
  • The cooling water circulation plates had been used to drop the temperature of refractory outside shell of common cooling system by using cooling plate or stave type. When they are attacked by surrounding gas, they are corroded and the water flows in the refractory due to leakage of water. So, the life of refractory material is shortened and changed due to the worse conditions of cooling system. The automatic sensing device for water leakage of cooling plate is developed to check the position of trouble by using the microprocessor system when cooling water leak and gas are flowed into the cooling plate through the leakage position. The flowed gas is detected in the micro-process system which delivers the detected position of cooling plate or stave to main control room through the wireless-radio relay station. This system can be possible to detect the position of cooling plate or stave against the water leakage part immediately and then deliver the signal to main control room by using the microprocessor system and wireless-radio relay station. This system will be developed in changing the working condition from manual system to unmanned auto alarm system.

Control of Grain Refinement and Anisotropy of NdFeB Alloy Powder by Severe Plastic Deformation Fabricated by the Gas Atomization Process (가스분무로 제조된 NdFeB 합금분말의 강소성변형을 통한 결정립 미세화 및 이방성 제어)

  • Cho, J.Y.;Park, S.M.;Hussain, J.;Song, M.S.;Kim, T.S.
    • Transactions of Materials Processing
    • /
    • v.31 no.3
    • /
    • pp.124-128
    • /
    • 2022
  • NdFeB magnets have been positioned as the core materials in advanced technologies such as MRI (magnetic resonance imaging), FA (factory automation system), robot, motors, and so on based on the highest magnetic properties. To effectively improve the refined microstructure, the plastic deformation has been known as the good alternatives by the recrystallization. However, it has been regarded as being impossible because of the few slip systems in the RE-Fe-B magnets at room temperature. The purpose of this study was to investigate the possibility of control of grain refinement and magnetic anisotropy of NdFeB alloy powder by the severe plastic deformation. The NdFeB magnet powder was fabricated by gas atomization process, and the powder was pre-compacted at high temperature. The pre-compacted billets were deformed by HPT (high pressure torsion), and then the deformed billets were observed microstructure and magnetic properties. After the HPT process at room temperature, the grain size decreased with increasing because of the melted Nd-rich phase, and the anisotropy of Nd2Fe14B phase was formed after the HPT process.

A Study on an Evaluation Method for Human/System Interface of Advanced Supervisory Control Systems in Nuclear Power Plant (신형 원자력발전소 감시제어체계의 인간/체계 인터페이스 평가 방법에 관한 연구)

  • Lee, Dong-Ha;Im, Hyeon-Gyo;Jeong, Byeong-Yong
    • Journal of the Ergonomics Society of Korea
    • /
    • v.18 no.3
    • /
    • pp.153-169
    • /
    • 1999
  • The design of nuclear control room is advancing toward totally computer based human system interfaces (HSI). Computer based interfaces offer the opportunity to provide improved support of operator performance, but if not properly deployed, can introduce new challenges. This paper reviews the Westinghouse AP-600 Human Factors Verification and Validation Plan selected for HSI evaluation model of Korea next generation nuclear control rooms. The AP-600 HSI evaluation model addressed 15 evaluation issues considering major activity class of operator and task complexity factors. This paper also describes the test procedures experimenters should follow to evaluate the addressed issues.

  • PDF

Development of cryogenic free-piston reciprocating expander utilizing phase controller

  • Cha, Jeongmin;Park, Jiho;Kim, Kyungjoong;Jeong, Sangkwon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.18 no.2
    • /
    • pp.42-47
    • /
    • 2016
  • A free-piston reciprocating expander is a device which operates without any mechanical linkage to a stationary part. Since the motion of the floating piston is only controlled by the pressure difference at two ends of the piston, this kind of expander may indispensably require a sophisticated active control system equipped with multiple valves and reservoirs. In this paper, we have suggested a novel design that can further reduce complexity of the previously developed cryogenic free-piston expander configuration. It is a simple replacement of both multiple valves and reservoirs by a combination of an orifice valve and a reservoir. The functional characteristic of the integrated orifice-reservoir configuration is similar to that of a phase controller applied in a pulse tube refrigerator so that we designate the one as a phase controller. Depending on the orifice valve size in the phase controller, the different PV work which affects the expander performance is generated. The numerical model of this unique free-piston reciprocating expander utilizing a phase controller is established to understand and analyze quantitatively the performance variation of the expander under different valve timing and orifice valve size. The room temperature experiments are carried out to examine the performance of this newly developed cryogenic expander.

Development of Human Performance Measures for Human Factors Validation in Advanced Nuclear Power Plants (신형원전 주제어실 인적요소 검증을 위한 인적수행도 평가척도 개발)

  • Ha, Jun-Su;Seong, Poong-Hyun
    • Journal of the Ergonomics Society of Korea
    • /
    • v.25 no.3
    • /
    • pp.85-96
    • /
    • 2006
  • Main control room(MCR) man-machine interface(MMI) design of advanced nuclear power plants(NPPs) such as APR(advanced power reactor)-1400 can be validated through performance-based tests to determine whether it acceptably supports safe operation of the plant. In this work, plant performance, personnel task, situation awareness, workload, teamwork, and anthropometric/physiological factor are considered as factors for the human performance evaluation. For development of measures in each of the factors, techniques generally used in various industries and empirically proven to be useful are adopted as main measures and some helpful techniques are developed in order to complement the main measures. Also the development of the measures is addressed based on the theoretical background. Finally we discuss the way in which the measures can be effectively integrated and then HUPESS(HUman Performance Evaluation Support System) which is in development based on the integrated way is briefly introduced.

Status of Infection Control in Jeju-area General Hospitals (제주특별자치도 종합병원의 감염관리 현황)

  • Chong, Moo Sang;Lee, Kyutaeg
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.48 no.2
    • /
    • pp.130-136
    • /
    • 2016
  • The aim of this study was to examine and analyze the infection management status of Jeju-area general hospitals, and in order to convey the importance of infection management, and to determine role plans of medical technologists as infection management staff, the infection management status was examined through surveys targeting 7 general hospitals located in Jeju Special Self-Governing Province. The infection management of Jeju-area medical institutions showed excellence in that all institutions operated an infection management room, there was dedicated manpower, and hospital infection management guidelines were established and executed. However most institutions were operating their infection management room with only 1 nurse, reporting many difficulties in securing dedicated manpower, microbe-related culture deciphering, frequency of multiple-resistance bacteria, infection statistics, and details on microbe testing. Accordingly, it is believed that the medical technologist who can perform the practical tasks of infection management has sufficient qualification and experience in infection management as per the medical law enforcement regulations, and in operation of an infection management room. If medical technologists (infection control microbiological technologist) with expert knowledge on microbes and infection control nurses can execute the tasks as dedicated personnel, the operation of the infection management room will be more advanced. In addition, for proper infection management in the future, the introduction of a medical system specialized in infection management and full support for infection management of vulnerable small/medium hospitals in addition to general hospitals across the country is considered important.

Control of Working Temperature of Isothermal Magnetic Entropy Change in La0.8Nd0.2(Fe0.88Si0.12)13 by Hydrogen Absorption for Magnetic Refrigerants

  • Fujieda, S.;Fujita, A.;Fukamichi, K.;Suzuki, S.
    • Journal of Magnetics
    • /
    • v.18 no.2
    • /
    • pp.150-154
    • /
    • 2013
  • $La_{1-z}Nd_z(Fe_{0.88}Si_{0.12})_{13}$ and their hydrides were investigated to obtain large magnetocaloric effects (MCEs) in a wide temperature range, including room temperature, for applications in magnetic refrigents. Since the magnetization change due to the itinerant-electron metamagentic (IEM) transition for $La_{1-z}Nd_z(Fe_{0.88}Si_{0.12})_{13}$ becomes larger with increasing z, the isothermal magnetic entropy change ${\Delta}S_m$ and the relative cooling power (RCP) are enhanced. In addition, the Curie temperatrue $T_C$ of $La_{0.8}Nd_{0.2}(Fe_{0.88}Si_{0.12})_{13}$ is increased from 193 to 319 K by hydrogen absorption, with the IEM transition. The maximum value of $-{\Delta}S_m$, $-{\Delta}S{_m}^{max}$, in a magnetic field change of 2 T for $La_{0.8}Nd_{0.2}(Fe_{0.88}Si_{0.12})_{13}H_{1.1}$ is about 23 J/kg K at $T_C$ = 288 K, which is larger than that of 19 J/kg K at $T_C$ = 276 K for $La(Fe_{0.88}Si_{0.12})_{13}H_{1.0}$. The value of RCP = 179 J/kg of the former is also larger than 160 J/kg of the latter. It is concluded that the partial substitution of Nd improves MCEs in a wide temperautre range, including room temperature.

A Study on Measures to Improve Smoke Control Performance in Case of Fire in a Clean room as an LCD Manufacturing Process (LCD 제조공정 클린룸의 화재시 CFD를 이용한 제연성능 개선대책에 관한 연구)

  • Son, Bong-Sei;Jang, Chan-Hee
    • Fire Science and Engineering
    • /
    • v.26 no.5
    • /
    • pp.41-47
    • /
    • 2012
  • As a core process in the manufacture of state-of-the-art industrial technologies such as semiconductor and LCD, a clean room is the most important process which can affect the performance and quality of products drastically. Nevertheless, scientific research on comprehensive safety measures from a fire protection standpoint is not being carried out in Korea. This study aims to derive measures to improve smoke control systems by identifying performance and problems of smoke systems installed in clean rooms as an LCD manufacturing process and analyzing fire and evacuation simulations considering several scenarios. As a result of analysis of fires and smoke in a clean roomas an LCD manufacturing process, it is found to be necessary to stop air handling units through interlocking in case of a fire and exhaust smoke out of the room through the top of FAB in consideration of buoyancy of smoke. It is also found to be necessary to install quick response sprinkler heads and accessories to accelerate the response time, because the heat-accumulating performance of sprinkler heads decreases in this application. Despite its low density of dwelling due to the automation process, clean room is characterized by an array of complex production equipment and working environment requiring dustproof clothes, which makes it difficult to acquire evacuation safety performance. Thus, thorough control of danger factors in processes and periodic education and training are required. It is also necessary to establish a level of domestic technologies equivalent to the level of standards of advanced countries in fire protection.

The maintenance record of the KSTAR helium refrigeration system

  • Moon, K.M.;Joo, J.J.;Kim, N.W.;Chang, Y.B.;Park, D.S.;Kwag, S.W.;Song, N.H.;Lee, H.J.;Lee, Y.J.;Park, Y.M.;Yang, H.L.;Oh, Y.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.4
    • /
    • pp.6-9
    • /
    • 2013
  • Korea Superconducting Tokamak Advanced Research (KSTAR) has a helium refrigeration system (HRS) with the cooling capacity of 9 kW at 4.5 K. Main cold components are composed of 300 tons of superconducting (SC) magnets, main cryostat thermal shields, and SC current feeder system. The HRS comprises six gas storage tanks, a liquid nitrogen tank, the room temperature compression sector, the cold box (C/B), the 1st stage helium distribution box (DB#1), the PLC base local control system interconnected to central control tower and so on. Between HRS and cold components, there's another distribution box (DB#2) nearby the KSTAR device. The entire KSTAR device was constructed in 2007 and has been operated since 2008. This paper will present the maintenance result of the KSTAR HRS during the campaign and discuss the operation record and maintenance history of the KSTAR HRS.