• 제목/요약/키워드: advanced control room

검색결과 124건 처리시간 0.026초

Training Requirements for Control Room Operators of an Advanced Nuclear Power Plant

  • Park, Hong Joon;Park, Geun Ok;Kim, Sa Kil;Byun, Seong Nam
    • 대한인간공학회지
    • /
    • 제32권1호
    • /
    • pp.107-115
    • /
    • 2013
  • Objective: The aim of this study is to identify the training requirements of new nuclear power plant by a comprehensive literature review. Background: The design of instrumental and control systems for New NPP is applied fully digitalized systems. For example, soft-control, large display panels(LDP), and an advanced alarm system were applied to the APR-1400 or SMART. Method: The NUREG-0711 and international guideline of training program was analyzed from the following four phases of SAT(Systemic Approach to Training): Analysis, Design, Development, Implementation and Evaluation. Results: To identify the requirement of training program, 'Feedback' phase was considered and each phase of SAT was classified. Conclusion: A more systematic requirement of training program is needed which considers the computerized system was applied to the new NPP. Application: The results of the publishing can be useful for standardization of the systematic training program for the operators of NPP.

A Study on the Automatic Sensing Device for Gas Leakage of Cooling Plate Using the Microprocessor System

  • Wang, Jee-Seok;Yoon, Hee-Jong;Kang, Ki-Seong;Kim, Jong-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권3호
    • /
    • pp.329-334
    • /
    • 2011
  • The cooling water circulation plates had been used to drop the temperature of refractory outside shell of common cooling system by using cooling plate or stave type. When they are attacked by surrounding gas, they are corroded and the water flows in the refractory due to leakage of water. So, the life of refractory material is shortened and changed due to the worse conditions of cooling system. The automatic sensing device for water leakage of cooling plate is developed to check the position of trouble by using the microprocessor system when cooling water leak and gas are flowed into the cooling plate through the leakage position. The flowed gas is detected in the micro-process system which delivers the detected position of cooling plate or stave to main control room through the wireless-radio relay station. This system can be possible to detect the position of cooling plate or stave against the water leakage part immediately and then deliver the signal to main control room by using the microprocessor system and wireless-radio relay station. This system will be developed in changing the working condition from manual system to unmanned auto alarm system.

가스분무로 제조된 NdFeB 합금분말의 강소성변형을 통한 결정립 미세화 및 이방성 제어 (Control of Grain Refinement and Anisotropy of NdFeB Alloy Powder by Severe Plastic Deformation Fabricated by the Gas Atomization Process)

  • 조주영;박상민;자비드 후세인;송명석;김택수
    • 소성∙가공
    • /
    • 제31권3호
    • /
    • pp.124-128
    • /
    • 2022
  • NdFeB magnets have been positioned as the core materials in advanced technologies such as MRI (magnetic resonance imaging), FA (factory automation system), robot, motors, and so on based on the highest magnetic properties. To effectively improve the refined microstructure, the plastic deformation has been known as the good alternatives by the recrystallization. However, it has been regarded as being impossible because of the few slip systems in the RE-Fe-B magnets at room temperature. The purpose of this study was to investigate the possibility of control of grain refinement and magnetic anisotropy of NdFeB alloy powder by the severe plastic deformation. The NdFeB magnet powder was fabricated by gas atomization process, and the powder was pre-compacted at high temperature. The pre-compacted billets were deformed by HPT (high pressure torsion), and then the deformed billets were observed microstructure and magnetic properties. After the HPT process at room temperature, the grain size decreased with increasing because of the melted Nd-rich phase, and the anisotropy of Nd2Fe14B phase was formed after the HPT process.

신형 원자력발전소 감시제어체계의 인간/체계 인터페이스 평가 방법에 관한 연구 (A Study on an Evaluation Method for Human/System Interface of Advanced Supervisory Control Systems in Nuclear Power Plant)

  • 이동하;임현교;정병용
    • 대한인간공학회지
    • /
    • 제18권3호
    • /
    • pp.153-169
    • /
    • 1999
  • The design of nuclear control room is advancing toward totally computer based human system interfaces (HSI). Computer based interfaces offer the opportunity to provide improved support of operator performance, but if not properly deployed, can introduce new challenges. This paper reviews the Westinghouse AP-600 Human Factors Verification and Validation Plan selected for HSI evaluation model of Korea next generation nuclear control rooms. The AP-600 HSI evaluation model addressed 15 evaluation issues considering major activity class of operator and task complexity factors. This paper also describes the test procedures experimenters should follow to evaluate the addressed issues.

  • PDF

Development of cryogenic free-piston reciprocating expander utilizing phase controller

  • Cha, Jeongmin;Park, Jiho;Kim, Kyungjoong;Jeong, Sangkwon
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제18권2호
    • /
    • pp.42-47
    • /
    • 2016
  • A free-piston reciprocating expander is a device which operates without any mechanical linkage to a stationary part. Since the motion of the floating piston is only controlled by the pressure difference at two ends of the piston, this kind of expander may indispensably require a sophisticated active control system equipped with multiple valves and reservoirs. In this paper, we have suggested a novel design that can further reduce complexity of the previously developed cryogenic free-piston expander configuration. It is a simple replacement of both multiple valves and reservoirs by a combination of an orifice valve and a reservoir. The functional characteristic of the integrated orifice-reservoir configuration is similar to that of a phase controller applied in a pulse tube refrigerator so that we designate the one as a phase controller. Depending on the orifice valve size in the phase controller, the different PV work which affects the expander performance is generated. The numerical model of this unique free-piston reciprocating expander utilizing a phase controller is established to understand and analyze quantitatively the performance variation of the expander under different valve timing and orifice valve size. The room temperature experiments are carried out to examine the performance of this newly developed cryogenic expander.

신형원전 주제어실 인적요소 검증을 위한 인적수행도 평가척도 개발 (Development of Human Performance Measures for Human Factors Validation in Advanced Nuclear Power Plants)

  • 하준수;성풍현
    • 대한인간공학회지
    • /
    • 제25권3호
    • /
    • pp.85-96
    • /
    • 2006
  • Main control room(MCR) man-machine interface(MMI) design of advanced nuclear power plants(NPPs) such as APR(advanced power reactor)-1400 can be validated through performance-based tests to determine whether it acceptably supports safe operation of the plant. In this work, plant performance, personnel task, situation awareness, workload, teamwork, and anthropometric/physiological factor are considered as factors for the human performance evaluation. For development of measures in each of the factors, techniques generally used in various industries and empirically proven to be useful are adopted as main measures and some helpful techniques are developed in order to complement the main measures. Also the development of the measures is addressed based on the theoretical background. Finally we discuss the way in which the measures can be effectively integrated and then HUPESS(HUman Performance Evaluation Support System) which is in development based on the integrated way is briefly introduced.

제주특별자치도 종합병원의 감염관리 현황 (Status of Infection Control in Jeju-area General Hospitals)

  • 정무상;이규택
    • 대한임상검사과학회지
    • /
    • 제48권2호
    • /
    • pp.130-136
    • /
    • 2016
  • 제주지역 종합병원 감염관리 현황을 조사하여, 병원감염관리 실태와 문제점을 파악하고자 하였으며 감염관리의 중요성을 인식시키고 감염관리 실무자로서 임상병리사의 역할 방안을 모색하기 위하여 제주특별자치도 제주시와 서귀포시에 위치한 종합병원 7개 기관을 대상으로 감염관리 현황을 설문지를 통하여 조사하였다. 제주지역 의료기관의 감염관리는 모든 기관이 감염관리실을 운영하고 전담인력을 구성하고 병원감염관리지침을 보유하고 수행하는 우수한 점을 보였지만, 대부분의 기관이 간호사 1인 구성의 감염관리실을 운영하여 전담인력 확보 및 미생물 관련 배양 판독, 다제내성균의 출현빈도, 감염통계 등 미생물 검사에 대한 내용을 보고 받는데 많은 부분 어려움을 호소하였다. 이에 감염관리의 실질적인 업무를 담당할 수 있는 임상병리사가 의료법 시행규칙에 있는 감염관리에 경험과 지식이 있는 사람으로 충분한 자질과 경험이 있다고 생각되며 감염관리실을 운영함에 있어 감염관리간호사와 미생물에 전문적인 지식을 갖춘 임상병리사(감염관리임상병리사)가 전담자로서 업무를 수행한다면 지금보다 더욱 발전된 감염관리실 운영이 될 것으로 보이며, 향후 감염관리를 제대로 하기 위해서는 전국적으로 종합병원을 비롯한 취약한 중소병원의 감염관리에 대한 전폭적 지원과 감염관리 전문 의료시스템 도입이 중요한 과제라 사료된다.

Control of Working Temperature of Isothermal Magnetic Entropy Change in La0.8Nd0.2(Fe0.88Si0.12)13 by Hydrogen Absorption for Magnetic Refrigerants

  • Fujieda, S.;Fujita, A.;Fukamichi, K.;Suzuki, S.
    • Journal of Magnetics
    • /
    • 제18권2호
    • /
    • pp.150-154
    • /
    • 2013
  • $La_{1-z}Nd_z(Fe_{0.88}Si_{0.12})_{13}$ and their hydrides were investigated to obtain large magnetocaloric effects (MCEs) in a wide temperature range, including room temperature, for applications in magnetic refrigents. Since the magnetization change due to the itinerant-electron metamagentic (IEM) transition for $La_{1-z}Nd_z(Fe_{0.88}Si_{0.12})_{13}$ becomes larger with increasing z, the isothermal magnetic entropy change ${\Delta}S_m$ and the relative cooling power (RCP) are enhanced. In addition, the Curie temperatrue $T_C$ of $La_{0.8}Nd_{0.2}(Fe_{0.88}Si_{0.12})_{13}$ is increased from 193 to 319 K by hydrogen absorption, with the IEM transition. The maximum value of $-{\Delta}S_m$, $-{\Delta}S{_m}^{max}$, in a magnetic field change of 2 T for $La_{0.8}Nd_{0.2}(Fe_{0.88}Si_{0.12})_{13}H_{1.1}$ is about 23 J/kg K at $T_C$ = 288 K, which is larger than that of 19 J/kg K at $T_C$ = 276 K for $La(Fe_{0.88}Si_{0.12})_{13}H_{1.0}$. The value of RCP = 179 J/kg of the former is also larger than 160 J/kg of the latter. It is concluded that the partial substitution of Nd improves MCEs in a wide temperautre range, including room temperature.

LCD 제조공정 클린룸의 화재시 CFD를 이용한 제연성능 개선대책에 관한 연구 (A Study on Measures to Improve Smoke Control Performance in Case of Fire in a Clean room as an LCD Manufacturing Process)

  • 손봉세;장찬희
    • 한국화재소방학회논문지
    • /
    • 제26권5호
    • /
    • pp.41-47
    • /
    • 2012
  • 첨단산업기술인 반도체, LCD 등 제조의 핵심공정인 클린룸은 생산제품의 성능 및 품질에 절대적인 영향을 미치는 가장 중요한 공정이다. 그러나 국내는 방화공학적인 측면에서 과학적이고 종합안전대책에 대한 체계적인 연구가 제대로 이루어지지 않고 있다. 본 연구는 LCD 제조공정 클린룸에 설치하는 제연시스템의 성능 및 문제점을 파악하여 이에 대한 개선방안을 도출하기 위하여 여러 시나리오를 고려한 화재시뮬레이션과 피난시뮬레이션을 통하여 분석하였다. LCD 제조공정의 클린룸 화재 및 연기확산에 대하여 분석한 결과 화재시 공조기의 연동정지는 반드시 필요하며 연기의 부력을 고려하여 FAB 상부에 배연을 할 수 있도록 하여야 한다. 또한 대규모 클린룸의 경우 화재특성상 스프링클러헤드의 집열 성능이 떨어지므로, 조기반응형 헤드의 설치 및 작동시간을 빠르게 하기 위한 보조장치를 설치하여야 한다. 특히, 대공간 클린룸은 자동화 공정으로 거주밀도가 낮지만, 복잡한 생산장비의 배치와 방진복을 착용하고 근무해야하는 환경특성 때문에 화재시 피난안전성능 확보가 어렵기 때문에 공정 내 위험요소의 철저한 관리 및 주기적인 교육과 훈련이 필요하며, 방재선진국의 기준에 준하는 수준의 국내 관련기술 기준을 정립할 필요가 있다.

The maintenance record of the KSTAR helium refrigeration system

  • Moon, K.M.;Joo, J.J.;Kim, N.W.;Chang, Y.B.;Park, D.S.;Kwag, S.W.;Song, N.H.;Lee, H.J.;Lee, Y.J.;Park, Y.M.;Yang, H.L.;Oh, Y.K.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권4호
    • /
    • pp.6-9
    • /
    • 2013
  • Korea Superconducting Tokamak Advanced Research (KSTAR) has a helium refrigeration system (HRS) with the cooling capacity of 9 kW at 4.5 K. Main cold components are composed of 300 tons of superconducting (SC) magnets, main cryostat thermal shields, and SC current feeder system. The HRS comprises six gas storage tanks, a liquid nitrogen tank, the room temperature compression sector, the cold box (C/B), the 1st stage helium distribution box (DB#1), the PLC base local control system interconnected to central control tower and so on. Between HRS and cold components, there's another distribution box (DB#2) nearby the KSTAR device. The entire KSTAR device was constructed in 2007 and has been operated since 2008. This paper will present the maintenance result of the KSTAR HRS during the campaign and discuss the operation record and maintenance history of the KSTAR HRS.