• Title/Summary/Keyword: adjustable parameters

검색결과 123건 처리시간 0.027초

DIRECT FREQUENCY REPRESENTATION OF PULSE PATTERNS FOR CONTROLLED VOLTAGE SOURCE INVERTERS

  • Oleschuk, Valentin;Bose, Bimal K.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.165-170
    • /
    • 1998
  • The paper describes developed method of feedforward digital modulation of line-to-line voltage of 3-phase inverter for drive application. It is based on representation of parameters of output voltage of inverter in function of operating frequency of drive system. Pure algebraic control laws and big computational simplicity characterize this scheme of modulation. It has been presented results of simulation of adjustable drive systems with the method of pulse-width modulation described.

  • PDF

적응 뉴로 퍼지추론 기법에 의한 비선형 시스템의 구조 동정에 관한 연구 (Structure Identification of Nonlinear System Using Adaptive Neuro-Fuzzy Inference Technique)

  • 이준탁;정형환;심영진;김형배;박영식
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 1996년도 추계학술대회 학술발표 논문집
    • /
    • pp.298-301
    • /
    • 1996
  • This paper describes the structure Identification of nonlinear function using Adaptive Neuro-Fuzzy Inference Technique(ANFIS). Nonlinear mapping relationship between inputs and outputs were modeled by Sugeno-Takaki's Fuzzy Inference Method. Specially, the consequent parts were identified using a series of 1st order equations and the antecedent parts using triangular type membership function or bell type ones. According to learning Rules of ANFIS, adjustable parameters were converged rapidly and accurately.

  • PDF

BJRNAFold: Prediction of RNA Secondary Structure Base on Constraint Parameters

  • Li, Wuju;Ying, Xiaomin
    • 한국생물정보학회:학술대회논문집
    • /
    • 한국생물정보시스템생물학회 2005년도 BIOINFO 2005
    • /
    • pp.287-293
    • /
    • 2005
  • Predicting RNA secondary structure as accurately as possible is very important in functional analysis of RNA molecules. However, different prediction methods and related parameters including terminal GU pair of helices, minimum length of helices, and free energy systems often give different prediction results for the same RNA sequence. Then, which structure is more important than the others? i.e. which combinations of the methods and related parameters are the optimal? In order to investigate above problems, first, three prediction methods, namely, random stacking of helical regions (RS), helical regions distribution (HD), and Zuker's minimum free energy algorithm (ZMFE) were compared by taking 1139 tRNA sequences from Rfam database as the samples with different combinations of parameters. The optimal parameters are derived. Second, Zuker's dynamic programming method for prediction of RNA secondary structure was revised using the above optimal parameters and related software BJRNAFold was developed. Third, the effects of short-range interaction were studied. The results indicated that the prediction accuracy would be improved much if proper short-range factor were introduced. But the optimal short-range factor was difficult to determine. A user-adjustable parameter for short-range factor was introduced in BJRNAFold software.

  • PDF

Stochastic vibration response of a sandwich beam with nonlinear adjustable visco-elastomer core and supported mass

  • Ying, Z.G.;Ni, Y.Q.;Duan, Y.F.
    • Structural Engineering and Mechanics
    • /
    • 제64권2호
    • /
    • pp.259-270
    • /
    • 2017
  • The stochastic vibration response of the sandwich beam with the nonlinear adjustable visco-elastomer core and supported mass under stochastic support motion excitations is studied. The nonlinear dynamic properties of the visco-elastomer core are considered. The nonlinear partial differential equations for the horizontal and vertical coupling motions of the sandwich beam are derived. An analytical solution method for the stochastic vibration response of the nonlinear sandwich beam is developed. The nonlinear partial differential equations are converted into the nonlinear ordinary differential equations representing the nonlinear stochastic multi-degree-of-freedom system by using the Galerkin method. The nonlinear stochastic system is converted further into the equivalent quasi-linear system by using the statistic linearization method. The frequency-response function, response spectral density and mean square response expressions of the nonlinear sandwich beam are obtained. Numerical results are given to illustrate new stochastic vibration response characteristics and response reduction capability of the sandwich beam with the nonlinear visco-elastomer core and supported mass under stochastic support motion excitations. The influences of geometric and physical parameters on the stochastic response of the nonlinear sandwich beam are discussed, and the numerical results of the nonlinear sandwich beam are compared with those of the sandwich beam with linear visco-elastomer core.

전기자동차용 유·무선 통합 충전 시스템의 고효율 동작을 위한 권선비 가변형 LLC 컨버터 설계 및 제어 방안 (Design and Control of Adjustable Turn-ratio LLC Converter for High-efficiency Operation of Wired/Wireless Integrated Charging System for Electric Vehicles)

  • 조현우;심동현;이주아;손원진;이병국
    • 전력전자학회논문지
    • /
    • 제27권3호
    • /
    • pp.237-246
    • /
    • 2022
  • This paper proposes a method to adjust the turn ratio of a transformer for the high-efficiency operation of an LLC converter with a wide input range in a wired/wireless integrated charging system for electric vehicles. The characteristics of the inductive power transfer converter in the integrated charging system are analyzed to design the LLC converter, and the DC-link voltage range is derived. The aspect of voltage gain following each parameter of the LLC converter is analyzed, and the resonant network and transformer are designed. Based on the designed parameters, the feasibility of the design and control method is verified by implementing the operation of the LLC converter according to the DC-link and battery voltages.

Biphasic Electrical Nerve Stimulator for Medical Applications Generating a Wide Range of Pulse Specifications Without Microcontroller

  • Jun Sang Yu;Dong Rim Kim;Su Bin Kang;Jung Suk Kim
    • 대한의용생체공학회:의공학회지
    • /
    • 제45권4호
    • /
    • pp.173-178
    • /
    • 2024
  • We present an improved biphasic electrical nerve stimulator designed to overcome limitations. Traditional electrical nerve stimulators lacking a microcontroller unit (MCU) have restrictions in terms of frequency, pulse duration, and amplitude control, making them insufficient for medical applications requiring a broader range of pulse specifications. To address this, we developed a stimulator with enhanced capabilities. By not using an MCU, the design reduces power consumption and the required area, simplifying the overall design and increasing efficiency. In addition, our approach optimizes oscillator parameters to achieve wide frequency and pulse duration ranges. Specifically, we expanded the frequency range of the stimulator up to from 1 mHz to 100 kHz and the pulse duration up to from 5 ㎲ to 500 s. Improved amplitude control mechanisms were implemented for adjustable and high biphasic amplitudes. Furthermore, we added a balancing circuit to ensure proper discharging for tissue safety when biphasic pulses do not occur. The improved stimulator demonstrated an increase in operational range compared to traditional MCU-less designs, producing consistent biphasic pulses with adjustable amplitude and duration. The balancing circuit effectively managed discharging, reducing the risk of tissue damage and ensuring safety and efficacy.

High Performance Adjustable-Speed Induction Motor Drive System Incorporating Sensorless Vector Controlled PWM Inverter with Auto-Tuning Machine-Operated Parameter Estimation Schemes

  • Soshin, Koji;Okamura, Yukiniko;Ahmed, Tarek;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제3권2호
    • /
    • pp.99-114
    • /
    • 2003
  • This paper presents a feasible development on a highly accurate quick response adjustable speed drive implementation fur general purpose induction motor which operates on the basis of sensorless slip frequency type vector controlled sine-wave PWM inverter with an automatic tuning machine parameter estimation schemes. In the first place, the sensorless vector control theory on the three-phase voltage source-fed inverter induction motor drive system is developed in slip frequency based vector control principle. In particular, the essential procedure and considerations to measure and estimate the exact stator and rotor circuit parameters of general purpose induction motor are discussed under its operating conditions. The speed regulation characteristics of induction motor operated by the three-phase voltage-fed type current controlled PWM inverter using IGBT's is illustrated and evaluated fur machine parameter variations under the actual conditions of low frequency and high frequency operations for the load torque. In the second place, the variable speed induction motor drive system, employing sensorless vector control scheme which is based on three -phase high frequency carrier PWM inverter with automatic toning estimation schemes of the temperature -dependent and -independent machine circuit parameters, is practically implemented using DSP-based controller. Finally, the dynamic speed response performances for largely changed load torque disturbances as well as steady state speed vs. torque characteristics of this induction motor control implementation are illustrated and discussed from an experimental point of view.

Comparison of the Therapeutic Efficacy and Technical Outcomes between Conventional Fixed Electrodes and Adjustable Electrodes in the Radiofrequency Ablation of Benign Thyroid Nodules

  • Jae Ho Shin;Minkook Seo;Min Kyoung Lee;So Lyung Jung
    • Korean Journal of Radiology
    • /
    • 제25권2호
    • /
    • pp.199-209
    • /
    • 2024
  • Objective: This study aimed to compare therapeutic efficacy and technical outcomes between adjustable electrode (AE) and conventional fixed electrode (FE) for radiofrequency ablation (RFA) of benign thyroid nodules. Materials and Methods: Between 2013 and 2021, RFA was performed on histologically proven benign thyroid nodules. For the AE method, AE length ≥ 1 cm with higher power and < 1 cm with lower power were utilized for ablating feeding vessels and nodules, especially those near anatomical structures, respectively. The therapeutic efficacy (volume reduction rate [VRR], complication rate, and regrowth rate) and technical outcomes (total energy delivery, ablated volume/energy, RFA time, and ablated volume/time) of FE and AE were compared. Continuous parameters were compared using a two-sample t-test or Mann-Whitney U test, and categorical parameters were compared using a chi-squared test or Fisher's exact test. Results: A total of 182 nodules (FE: 92 vs. AE: 90) in 173 patients (mean age ± standard deviation, 47.0 ± 14.7 years; female, 90.8% [157/173]; median follow-up, 726 days [interquartile range, 441-1075 days]) were analyzed. The therapeutic efficacy was comparable, whereas technical outcomes were more favorable for AE. Both electrodes demonstrated comparable overall median VRR (FE: 92.4% vs. AE: 84.9%, P = 0.240) without immediate major complications. Overall regrowth rates were comparable between the two groups (FE: 2.2% [2/90] vs. AE: 1.1% [1/90], P > 0.99). AE demonstrated a shorter median RFA time (FE: 811 vs. AE: 627 seconds, P = 0.009). Both delivered comparable median energy (FE: 42.8 vs. AE: 29.2 kJ, P = 0.069), but AE demonstrated higher median ablated volume/energy and median ablated volume/time (FE: 0.2 vs. AE: 0.3 cc/kJ, P < 0.001; and FE: 0.7 vs. AE: 1.0 cc/min, P < 0.001, respectively). Conclusion: Therapeutic efficacy between FE and AE was comparable. AE demonstrated better technical outcomes than FE in terms of RFA time, ablated volume/energy, and ablated volume/time.

Waypoint Planning Algorithm Using Cost Functions for Surveillance

  • Lim, Seung-Han;Bang, Hyo-Choong
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제11권2호
    • /
    • pp.136-144
    • /
    • 2010
  • This paper presents an algorithm for planning waypoints for the operation of a surveillance mission using cooperative unmanned aerial vehicles (UAVs) in a given map. This algorithm is rather simple and intuitive; therefore, this algorithm is easily applied to actual scenarios as well as easily handled by operators. It is assumed that UAVs do not possess complete information about targets; therefore, kinematics, intelligence, and so forth of the targets are not considered when the algorithm is in operation. This assumption is reasonable since the algorithm is solely focused on a surveillance mission. Various parameters are introduced to make the algorithm flexible and adjustable. They are related to various cost functions, which is the main idea of this algorithm. These cost functions consist of certainty of map, waypoints of co-worker UAVs, their own current positions, and a level of interest. Each cost function is formed by simple and intuitive equations, and features are handled using the aforementioned parameters.

전동기 과전압 억제용 OUTPUT REACTOR의 최적 설계 (Cost-effective Design of an Inverter Output Reactor in ASD application)

  • 김한종;이근호;장철호;이제필
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.65-70
    • /
    • 1999
  • In this paper, the cost-effective design of output reactor which is used to suppress the over-voltage at the motor terminal in the Adjustable Speed Drives(ASD) application is proposed. In the elevator drive system, the power cable length is relatively shorter than other ASD applications and then the over-voltage at the motor terminal depends on the frequency characteristics of the output reactor at the over-voltage operating frequency. The over-voltage suppression mechanism of output reactor in ASD application is analyzed and the dominant parameters of output reactor for the over-voltage suppression are extracted. Using these parameters as the design values and considering the high frequency characteristics of iron core in the reactor, a new cost-effective structure of output reactor is proposed. Experimental results of the conventional reactor and the proposed reactor with a 15kW induction motor are given to verify the proposed scheme.

  • PDF