• 제목/요약/키워드: adjacent building

검색결과 348건 처리시간 0.028초

WUFI를 이용한 공동주택 붙박이가구의 층별·형태별 결로 생성 비교 평가 (Comparative Evaluation of Condensation by Type and Layer Around Built-in Furniture of Apartment Buildings)

  • 유지원;장성진;이종기;위승환;김수민
    • 한국가구학회지
    • /
    • 제29권1호
    • /
    • pp.31-39
    • /
    • 2018
  • Recently, as the continuously increasing of the one-person households, builders were focusing on a built-in furniture development for efficiency. Through the dead space of the space can be reduced. Also, Condensation that occurs in a built-in furnitures installation space may result in different results depending on the room's direction, floor, finish, adjacent room effect, occupant's lifestyle. In this background, it can be considered in terms of functional aspect and morphological aspect by using WUFI2D simulation system. As a result, the tendency of occurrence of condensation was examined by comparing the water content and the growth potential of fungus graph which came from WUFI2D. Results of this study are as followings: Built-in furniture, both top & bottom open, is more stable to condensation than the built-in furniture with the top or bottom open. Also, Among from the top floor built-in furniture to the bottom of it, the bottom one is more stable to condensation.

  • PDF

옥외광고용 발광조명의 야간휘도분포 분석 (Luminance Assessment of Outdoor Lighting for Advertisements at Night)

  • 신화영;이종수;김정태
    • KIEAE Journal
    • /
    • 제9권6호
    • /
    • pp.65-72
    • /
    • 2009
  • Lighting for outdoor advertising is very common feature of building facades as they provide the information and commercial identification. As the interest of improving street beautification more widely, application of various lighting technologies has been develop for advertisement such as electric sign board and signage. Furthermore, the installation of higher sign luminance than needed has many negative consequences, including higher energy consumption and light pollution. There are now no standard for outdoor advertisements in terms of luminance, and installation of indiscreet outdoor advertisement without luminance consideration is becoming more commonplace. This study was to evaluate the luminous characteristics of outdoor advertising as a function of sign and building facade luminance, luminance ratio. Data were collected on 8 electric sign boards, 20 internally illuminated, externally illuminated, neon, and channel letter signs and 4 commercial areas. Photometric measurements were taken by CS-100(Minolta) and ProMetric-1400(Radiant Imaging) for various sign modes and sign design. Also luminance of building facades were analyzed according with CIE standard of maximum obtrusive light permitted for exterior lighting installations. The findings are as follows; (1) There were excessive luminance of electric sign boards that could affect adjacent building facade and night sky luminance. (2) Sings that are externally illuminated providing an inappropriate amount of light on to the outer surface of the sign caused higher building facade luminance and potential of unnecessary glare.

건축구조물의 설계화재정립을 위한 실규모 화재실험 및 분석 (Experiment and Analysis of Real-Scale Fire Test for Establishment of Design Fire in Building Structures)

  • 서동구;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 추계 학술논문 발표대회
    • /
    • pp.119-120
    • /
    • 2014
  • In this study, we looked into the method to establish fire growth rate by buildings use for growing fire at the beginning of a fire considering the characteristics of the combustibles in a performance-based design. Actual conditions survey and literature review were carried out for the fire load and exposed surface area of combustibles to establish design fire by domestic building use. As a results, a simplified prediction equation of fire growth rate which depends on fire load and weight of combustibles could be derived by calculating the relation between the fire load and the fire growth rate of an initial fire through investigation of combustibles by domestic building use.Also, as a result of analyzing the placement of combustibles and location of the ignition source, it was found that the influence of the materials of the combustibles and the materials of the combustibles adjacent to the ignition source is big. Though 4 different experiments were carried out for the evaluation, the result of comparing the findings with those of FGR model showed that the fire growth rate was similarly derived.

  • PDF

방화구획과 수막설비 관한 연구 (Experimental study of water membrane sprinkler in fire prevention block)

  • 오창희;손장열;김화중;김상욱;최진
    • 한국화재소방학회논문지
    • /
    • 제2권3호
    • /
    • pp.3-9
    • /
    • 1988
  • This paper is study about establishment with water membrane sprinkler in fire prevention block of special Building. The testing program was directed toward investigating the temperature of fire and adjacent room. The results of fire test indicated that under the test conditions in this study, adjacent room temperature is very low in compare with fire room temperature at operating of water membrane sprinkler. Therefore, if exclusion of smoking can be soluted, substitution of water membrance sprinkler in fire resistance wall of fire prevention block is possible.

  • PDF

지반굴착공사로 인한 사고사례 분석 (Analysis of accidents due to Urban Ground Excavation)

  • 성주현;윤종구;정수형
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.1087-1094
    • /
    • 2010
  • With recent growth of population and industry, urban development grows into grand scheme of excavation and construction in urban area. As the development progress advanced, the developments get large and deepen. With a progress of technology development in geotechnical engineering in Korea, most our grand scheme of projects follows great progress. On the other hand, some excavation in construction site caused direct or indirect event that affects the adjacent or surrounding structures by excavation from time to time. This event usually happens around residential and commercial area where underground tunnel, subway station, commercial building, and high-rises excavation site is, could lead great damage on economy as well as personal injury or human casualties. In order to prevent this event, the study has to be done with analysis on various events of excavation and its cause. In this paper, the research has collected the various excavation events and their causes to analyze on each site and event to define emphasis on surrounding environment.

  • PDF

미국 CDI사의 건축물 발파해체 기법 (On the explosive demolition technology of construction building CDI, USA)

  • 장병하
    • 화약ㆍ발파
    • /
    • 제13권4호
    • /
    • pp.73-81
    • /
    • 1995
  • Explosives demolition mothod is allowed for more efficient time-saving and safer demolitioni operations as compared to conventional / mechanical demolition methods. CDI has to minimize the effects of noise, dust and various demolition hazards to the public areas, and residences that are located adjacent to the project site. CDI's explosives demolition work on the Nam san Foreigner's Apartment Complex and chosun trading Co's factory are backed by over 45 years of explosives experience in the demolition of over 6,000 structures worldwide, many of these structures are similar to the Nam san Foreigner's Apt. and Chosun trading's factory in construction and proximity to sensitive adjacent exposures. Recoginized worldwide as the founder of the leader in explosives demolitioni technology, CDI always will applied "State-of-the-Art" explosives techniques to safely and successfully achieve the desired demolition results on these project. CDI has never injured, much less caused any fatality, to either a worker on one of our sites or to a third party during the implosion of high-rise structure.

  • PDF

지하철 굴착공사에 따른 인접지반의 침하 해석 (Analysis of Peripheral Surface Settlement during Subway Excavation)

  • 문준석;권강오;김홍석;장연수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.621-628
    • /
    • 2000
  • In this study, the influence of groundwater variation and surface settlement adjacent to the excavation site of subway station on $\bigcirc$$\bigcirc$ Gas station and the $\bigcirc$$\bigcirc$ building is analized. Measurement data of surface settlement, horizontal deformation and groundwater level are used to verify the results of Caspe analytical method and FLAC numerical analysis. Variation of groundwater level adjacent to the excavation site is modelled by the 3-D groundwater flow program, MODFLOW. The results of both the analytical method and the numerical method were quite close to the measurement data of surface settlement.

  • PDF

도심지 터널 굴착에 따른 인접구조물의 손상평가에 관한 연구 (1) -지상 건물의 기하학적 및 위치적 특성을 중심으로- (A Study on the Safety Assessment of Adjacent Structures Caused by Tunnel Excavation in Urban Area -Focused on the Characteristics of Geometries and Locations for Nearby Building-)

  • 김창용;문현구;배규진
    • 한국지반공학회논문집
    • /
    • 제15권4호
    • /
    • pp.19-42
    • /
    • 1999
  • 도심지에 터널을 건설할 때는 설계ㆍ시공에 있어서 중요한 몇몇 고려 사항이 있다. 첫째는 특정한 지반조건과 시공조건에 대해서 지반변위의 크기와 분포를 예측하는 것이다. 두 번째는 예측된 지반거동에 상응하는 인접구조물들의 잠재적 손상을 평가하는 것이고, 셋째는 잠재적 손상이 예견되는 구조물에 대한 적절한 보강대책을 선정하는 것이다. 본 연구는 주로 첫 번째와 두 번째 단계의 문제를 해결하는데 주안점을 두고 있고 특히, 지상에 존재하는 건물의 기하학적 특성과 위치적 특성을 고려한 손상평가 방법에 연구의 초점을 두고 있다. 이를 위해서 도심지 터널 굴착 시 발생할 수 있는 지표침하 거동 예측 결과를 기반으로 예측할 수 있는 지상 건물의 손상평가 인자들(뒤틈각(angular distortion), 처짐비(deflection ratio), 건물의 최대침하량, 부등침하량, 수평변형률)을 도입하였고, 기존의 보수적인 해석 방법을 좀 더 발전시키기 위해서 지상에 존재하는 건물 벽체 각각에 대해서 분석할 수 있도록 이러한 인자들을 3차원적으로 표현할 수 있는 프로그램을 개발하였다. 또한, 건물의 기하학적, 위치적 특성 등의 변화에 대한 손상평가 인자들의 변화를 관찰하고, 실무에서 이러한 평가 결과를 활용할 수 있도록 가이드를 제시하고자 하였다. 한편, 국외의 몇몇 인접 건물에 대한 손상평가 사례와 본 연구에서 제안하고 있는 방법에 대한 비교 연구를 수행하여 현장에서 이를 활용할 수 있는 방법을 모색하였다.

  • PDF

Estimation of elastic seismic demands in TU structures using interactive relations between shear and torsion

  • Abegaz, Ruth A.;Lee, Han Seon
    • Earthquakes and Structures
    • /
    • 제19권1호
    • /
    • pp.59-77
    • /
    • 2020
  • The code static eccentricity model for elastic torsional design of structures has two critical shortcomings: (1) the negation of the inertial torsional moment at the center of mass (CM), particularly for torsionally-unbalanced (TU) building structures, and (2) the confusion caused by the discrepancy in the definition of the design eccentricity in codes and the resistance eccentricity commonly used by engineers such as in FEMA454. To overcome these shortcomings, using the resistance eccentricity model that can accommodate the inertial torsional moment at the CM, interactive relations between shear and torsion are proposed as follows: (1) elastic responses of structures at instants of peak edge-frame drifts are given as functions of resistance eccentricity, and (2) elastic hysteretic relationships between shear and torsion in forces and deformations are bounded by ellipsoids constructed using two adjacent dominant modes. Comparison of demands estimated using these two interactive relations with those from shake-table tests of two TU building structures (a 1:5-scale five-story reinforced concrete (RC) building model and a 1:12-scale 17-story RC building model) under the service level earthquake (SLE) show that these relations match experimental results of models reasonably well. Concepts proposed in this study enable engineers to not only visualize the overall picture of torsional behavior including the relationship between shear and torsion with the range of forces and deformations, but also pinpoint easily the information about critical responses of structures such as the maximum edge-frame drifts and the corresponding shear force and torsion moment with the eccentricity.

광기능성 창호시스템의 동절기 채광특성에 관한 목업연구 (Full-scale Mock-up Measurement of a Double Glazed Window System Equipped with Sunlight Controls)

  • 김곤
    • 한국태양에너지학회 논문집
    • /
    • 제28권4호
    • /
    • pp.35-42
    • /
    • 2008
  • Besides genuine skin and clothes, it is called that building is third skin for us. That means the skin of buildings is the most important factor for our man-made environment. The issues in designing the building envelope include the insulation, infiltration, ventilation and bridging in windows. Getting light into the space safely and providing views to outdoor, additionally, are key things with the building envelope design. A deep-rooted preference for full view is still alive with large area of glass. Balcony expansion is legalized in apartment houses, which causes lots of environmental problems. Without balcony space, the adjacent space to unshaded window is exposed to the direct sun. A window can have many layers and the inner space can be utilized with an automatic blind system. Recently, the refurbished version of a double-glazed window system has been developed for the purpose of minimizing energy loss occurred around windows. For the better daylight control with equipped blind system, a set of adjustment technique of blind slats was tested in a mock-up building and recommended the detail operation. Not surprisingly, the optimized blind system can be oriented to enhance the uniformity in light distribution and direct glare from the sky as well..