• 제목/요약/키워드: adiabatic temperature rising test

검색결과 14건 처리시간 0.021초

석탄 가스화 용융 슬래그를 잔골재로 사용한 콘크리트 단열온도상승 특성 (Properties of Adiabatic Temperature Rising of Concrete Using Coal Gasification Slag as Fine Aggregate)

  • 한준희;임군수;최일경;김종;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.114-115
    • /
    • 2021
  • The research team conducted a series of studies to use CGS as fine aggregate for concrete. In this paper, through the adiabatic temperature rising test, CGS' hydration heating performance and its usability as a mass concrete hydration heating agent were reviewed. According to the analysis, the maximum temperature of the mix of OPC 100 was 53.7℃, and the temperature of CGS 50% was 45.2℃, which was 8.5℃ lower than the OPC 100.

  • PDF

고로슬래그 미분말 치환율에 따른 콘크리트의 단열온도상승 평가 (Evaulation of Adiabatic Temperature Rise for Concrete with Blast-Furnace Slag replacement)

  • 김주형;이도헌;정상화
    • 한국건설순환자원학회논문집
    • /
    • 제8권1호
    • /
    • pp.18-24
    • /
    • 2013
  • 최근 친환경 콘크리트에 대한 관심이 높아지고 있다. 이에 따라 산업부산물인 고로슬래그 사용이 확대되고 있으며, 이에 대한 연구도 활발히 이루어지고 있다. 고로슬래그는 콘크리트 내부의 치밀화를 통해 내구성 향상에 도움이 되는 것으로 알려져 있다. 본 연구에서는 물-결합재비별 다양한 고로슬래그 치환에 따른 단열온도상승시험을 통해 고로슬래그 사용 콘크리트의 발열 및 수화 특성을 알아보려 한다. 콘크리트 배합은 물-결합재비를 각각 0.35, 0.45 0.55 3종류로 하였으며, 치환율은 변수별로 0, 15, 30, 45%를 하여 영향 특성을 파악하기 위한 배합을 선정하였으며, 압축강도 및 단열온도 상승시험을 진행을 실시하였다. 또한, 실험결과를 통해 콘크리트 표준시방서에 있는 단열온도상승식의 회귀분석 계수를 제시하였으며, 고로슬래그 치환율에 영향을 분석하였다. 실험결과에 따르면 압축강도는 고로슬래그 치환율이 높아질수록 약간의 저하 혹은 동등의 결과를 나타내었으며, 단열온도상승시험은 고로슬래그 치환율이 높아질수록 최종온도상승값은 저하하였으며, 회귀분석을 통해 상승계수값도 저하함을 확인할 수 있었다. 추후 좀 더 다양한 고로슬래그 치환율 및 결합재에 따른 단열온도상승식을 제시하는 연구가 필요할 것으로 판단된다.

  • PDF

C급 플라이애쉬 콘크리트의 장기특성에 관한 연구 (The Study on Long-Terms Properties of Concrete Using C Class Fly Ash)

  • 이상수;원철;권영호;안재현;박칠림
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1996년도 봄 학술발표회 논문집
    • /
    • pp.141-145
    • /
    • 1996
  • The primary purpose of this study is to investigate reusal techniques of by-product produced the combined heat power plant in the construction field, which may contribute to the savings of construction materials and the conservation of enviornment. This study is compared and evaluated by testing the chemical resistance, adiabatic temperature rising test, creep and drying shrinkage. As the result of the study, the following conclusions are derived : (1) hydration heat of the fly ash concrete is less than the plain concrete in adiabatic temperature rising test, (2) the fly axh concrete (FA 30%) is similar to the plain concrete in the chemical resistamce, (3) the fly ash concrete (FA 10, 30%) is similar to the plain concrete in drying shrinkage, but the fly ash concrete (FA 50%) is highly increased, (4) the fly ash concrete (FA 30%) is less than the plain concrete in creep test.

  • PDF

결합재 종류에 따른 콘크리트의 단열온도상승특성 및 단열온도상승에 따른 압축강도특성에 관한 연구 (Properties of Adiabatic Temperature Rise of Concrete Using Different Types of Binder and Effects of Adiabatic Temperature on the Compressive Strength)

  • 하재담;김태홍;이종열;김진근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.527-532
    • /
    • 2001
  • The crack of concrete induced by a temperature rise in early age concrete due to the heat of ration of cement is a serious problem for massive or high strength concrete structures. However, re is still no reasonable equations for the prediction of the temperature rising. On this study, the prediction equations of the heat of hydration of different types of binder are pained from the adiabatic temperature rise test, and compared with the results from different nations to obtain the best approximated equation. The strengths of concrete of which specimens were placed in the same chamber for the adiabatic to were compared with those under standard curing.

  • PDF

FA시멘트 및 CGS 치환율에 따른 콘크리트의 단열온도상승 특성 (Characteristics of Adiabatic Temperature Rise for Concrete according to FA Cement and CGS Replacement Rate)

  • 백성진;후윈야오;김수호;한준희;윤치환;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 봄 학술논문 발표대회
    • /
    • pp.117-118
    • /
    • 2022
  • In this study, adiabatic temperature rise of concrete depending on binder compositions and CGS contents is studied to provide informations for CGS low-heating aggregate and mixture designs for upper and lower placement lifts. Test nresults indicate that it is desirable to apply the combination of binders between top and bottom lift. For top lift, SESC or ESC is recommended, and for bottom lift, FAC+CGS 50 % is good for material composition.

  • PDF

A Study on the Optimum Mix Proportion of the Mass Concrete Designed as Massive and Deep Structure

  • Kwon Yeong-Ho;Lee Hwa-Jin
    • 콘크리트학회논문집
    • /
    • 제17권2호
    • /
    • pp.293-302
    • /
    • 2005
  • This study describes data from determination of the optimum mix proportion and site application of the mass concrete placed in bottom slab and side wall having a large depth and section as main structures of LNG in-ground tank. This concrete requires low heat hydration, excellent balance between workability and consistency because concreting work of LNG in-ground tank is usually classified by under-pumping, adaptation of longer vertical and horizontal pumping line than ordinary pumping condition. For this purpose, low heat Portland cement and lime stone powder as cementitious materials are selected and design factors including unit cement and water content, water-binder ratio, fine aggregate ratio and adiabatic temperature rising are tested in the laboratory and batch plant. As experimental results, the optimum unit cement and water content are selected under $270kg/m^3$ and $l55{\~}l60 kg/m^3$ separately to control adiabatic temperature rising below $30^{\circ}C$ and to improve properties of the fresh and hardened concrete. Also, considering test results of the confined water ratio($\beta$p) and deformable coefficient(Ep), $30\%$ of lime stone powder by cement weight is selected as the optimum replacement ratio. After mix proportions of 5cases are tested and compared the adiabatic temperature rising($Q^{\infty}$, r), tensile and compressive strength, modulus of elasticity, teases satisfied with the required performances are chosen as the optimum mix design proportions of the side wall and bottom slab concrete. $Q^{\infty}$ and r are proved smaller than those of another project. Before application in the site, properties of the fresh concrete and actual mixing time by its ampere load are checked in the batch plant. Based on the results of this study, the optimum mix proportions of the massive concrete are applied successfully to the bottom slab and side wall in LNG in-ground tank.

3성분계 시멘트의 구성비 변화에 따른 페이스트 및 콘크리트의 내부온도 특성 (The Properties of Internal Temperature of Paste and Concrete according to Component Ratio Variation of Ternary System Cement)

  • 김연승;김동혁;지남용
    • 콘크리트학회논문집
    • /
    • 제20권6호
    • /
    • pp.797-807
    • /
    • 2008
  • 본 연구에서는 온도균열 저감이 기대되는 3성분계 시멘트를 사용한 페이스트 및 콘크리트의 간이단열온도 상승실험을 실시하여 3성분계 시멘트의 활성화를 위한 기초자료를 제공하고자 하였다. 페이스트 실험은 3가지 결합재를 단독사용 및 혼합사용 하였으며, 콘크리트 실험은 3가지 결합재를 동시에 혼입하여 실시하였다. 페이스트실험 결과 BFS보다 FA의 사용이 온도저감 효과가 좋았으며, 3성분계 시멘트페이스트에서는 BFS의 혼입률이 작고 FA의 혼입률이 클수록 온도가 낮게 나타났다. 온도상승속도 및 하강속도 또한 BFS의 혼입률이 작고 FA의 혼입률이 클수록 늦어졌다. 한편, 물결합재비가 높을수록 최고온도가 낮게 나타났다. 최고온도 도달시간은 OPC100, 2성분계 시멘트, 3성분계 시멘트 순으로 짧게 나타나 3성분계 시멘트 사용은 온도상승지연효과가 있었다. 콘크리트 실험 결과 3성분계 시멘트를 사용한 콘크리트는 OPC사용 콘크리트에 비해 최고온도가 약 $8{\sim}11^{\circ}C$ 정도 낮게 나타났고, 온도상승속도는 $47{\sim}51%$ 수준이며, 온도하강속도는 $37{\sim}42%$ 수준으로 나타났다. 콘크리트 시험체는 페이스트 시험체에 비해 현저히 낮은 온도와 느린 온도상승속도 및 하강속도를 보였는데, 이는 콘크리트 중의 골재에 의한 영향으로 페이스트 시험체보다 열손실량이 컸기 때문이다.

저발열 결합재 및 CGS를 잔골재로 치환한 매스콘크리트의 수화열 해석 (Hydration Heat Analysis of Mass Concrete Replacement of Low Heat Binder and CGS with Fine Aggregate)

  • 한준희;임군수;최일경;윤치환;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.235-236
    • /
    • 2021
  • This study evaluated temperature distribution through adiabatic temperature rising test and hydration heat Analysis as a performance verification to utilize CGS as a hydration heat reduction material for mass concrete when replacing it with fine aggregate. According to the analysis, the temperature difference between the center and the surface was the highest at about 30℃, followed by the CGS 50% at 26℃ and the low heat combiner FA 30% at 23℃.

  • PDF

결합재에 따른 자기충전 콘크리트의 시공성 및 경제성 평가에 관한 실험적 연구 (An Experimental Study on the Construction Performances and Economical Evaluation of the Self-compacting Concrete by Cementitious Materials)

  • 권영호
    • 콘크리트학회논문집
    • /
    • 제29권3호
    • /
    • pp.315-322
    • /
    • 2017
  • 본 연구는 결합재에 따른 자기충전 콘크리트의 현장 최적배합비의 선정 및 이에 따른 현장 시공성과 경제성을 평가하기 위한 것이다. 결합재로 슬래그 함량이 46.5%인 슬래그계와 $C_2S$함량이 51.4%인 벨라이트계, 그리고 석회석 미분말이 사용되었다. 물-시멘트비를 대상으로 유동성, 충전성, 재령별 압축강도를 측정하여 현장 최적배합조건을 선정하였으며, 이에 따른 평가항목으로 응결시간, 블리딩, 침하깊이, 단열온도 상승시험을 실시하였다. 현장 시공성 및 경제성 평가를 위하여 현장시공에 따른 콘크리트 물량과 재료비를 분석하였다. 실험결과, 유동성 및 압축강도에 만족하는 물-시멘트비는 슬래그계 41.0%, 벨라이트계 51.0%이며, 응결시간 및 블리딩량 종료시간은 슬래그계가 빨랐지만, 블리딩량은 슬래그계가 큰 것으로 나타났다. 단열온도 상승량 및 상승속도는 벨라이트계가 낮은 것으로 나타났다. 또한 배처 플랜트의 최적 배합시간은 75초가 적합하였으며 생산량은 $100{\sim}110m^3/hr$이었다. 재료비 및 콘크리트 물량에서 벨라이트계가 슬래그계보다 각각 14.0% 및 3.3% 절감되는 것으로 나타났기 때문에, 재령별 압축강도 발현을 제외하면 벨라이트계 자기충전 콘크리트가 시공성 및 경제성 등에서 우수하였다.

매시브한 해양구조물 적용을 위한 고로슬래그 혼입 콘크리트의 방청성능 평가에 관한 연구 (A Study on the Estimation of Corrosion Protection Performance of Concrete Containing Ground Granulated Blast-Furnace Slag for Massive Coastal Structures)

  • 유재강;김동석;박상준;원철;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2002년도 학술.기술논문발표회
    • /
    • pp.87-91
    • /
    • 2002
  • This paper investigates the corrosion inhibition and the reduction of hydration heat properties of Ground Granulated Blast-Furnace Slag (GGBFS) added concrete. Since the massive civil structure is vulnerable to the thermal crack by hydration. adiabatic temperature rising tests were performed for water-binder ratios from 43.2% to 47.3%, while replacing 15% to 50% of cement with GGBFS of equal weight. Then, the corrosion protection performance was evaluated using cylindrical specimens embedded with steel reinforcement according to the combination of 3 W/B ratios and 2 levels of chloride ion quantity. The corrosion area of the embedded steel ban was determined using the high pressure steam curing method specified in KS F 2561. The test results showed that the replacement of GGBFS was effective in reducing the hydration heat. The corrosion area of the embedded steel ban decreased as the replacement of GGBFS increased. However, the corrosion area of the steel bar was proportional to the autoclave cycle and the chloride ion quantity. Among the tested specimens, compressive strength, reduction of hydration heat, and corrosion inhibition performance were excellent when 50% of cement was replaced with GGBFS of equal weight.

  • PDF