• 제목/요약/키워드: adhesive pattern

검색결과 131건 처리시간 0.027초

상아질에 대한 자가 산부식 접착제의 전단결합강도와 SEM 분석 비교 (SHEAR BOND STRENGTH OF SELF-ETCHING ADHESIVES TO DENTIN AND SEM ANALYSIS)

  • 조영곤;노기선;김수미;이영곤;정진호;기영재
    • Restorative Dentistry and Endodontics
    • /
    • 제28권3호
    • /
    • pp.222-231
    • /
    • 2003
  • The purpose of this study was to compare shear bond strength and interfacial pattern of composite bond-ed to dentin using self-etching adhesive systems. Sixty extracted human molars with exposed occlusal dentin were divided into four groups and bonded with four adhesives and composites. Single Bond/Filtek Z 350(SB), Tyrian SPE-One-Step Plus/Aelitefil(TY), Prompt L-Pop/Filtek Z 250(LP), and One-Up Bond F/palfique Toughwell(OU). The results of this study were as follows; 1 Shear bond strength for OU was significantly lower than that of other groups(p<0.05). No significant difference was founded among SB, TY, and LP. 2. Failure modes to dentin showed adhesive and mixed for SB TY and LP, but them for OU showed adhesive in all spceimens. 3. Dentin-resin interface showed close adaptation for SB, TY, and LP, but it showed gap for OU. 4. The hybrid layers for TY, LP OU were thinner than that of SB. Adhesive layers were observed between composite and hybrid layer, which were 5 $\mu\textrm{m}$ thick for TY and 10 $\mu\textrm{m}$ thick for OU.

Gliding-Mobilization이 견관절유착성관절낭염 환자의 관절가동범위에 미치는 영향 (The Effects on the range of motion of joint with Gliding-Mobilization of the patients of adhesive capsulitis of the shoulder)

  • 정병옥;마상렬;김근조;안병헌
    • 대한물리치료과학회지
    • /
    • 제13권4호
    • /
    • pp.27-34
    • /
    • 2006
  • Purpose : The purpose of this study is to prove the increasing range of motion of joint to the patients of adhesive capsulitis of the shoulder applied the gliding-mobilization. Subjects and methods : The subjects are patients of adhesive capsulitis of the shoulder who have limited range of motion due to capsular pattern on the shoulder. The subjects are volunteer patients without a history of neuromuscular problems and randomly distributed into two groups. 15 experimental subjects(4 male, 11 female) received therapy with gliding-mobilization applied on limited shoulder joint and a second group with 15 control subjects(6 male 9 female) was treated by physiological passive range of motion therapy. The data were analyzed with paired t-test to determine striking differences depending on the course of treatment. Result : 1) In the group treated by gliding-mobilization the range of motion in shoulder flexion was increased in accordance to the course of treatment, and paired t-test showed striking differences(p<.05). 2) The range of motion in shoulder extension was increased in accordance to the course of treatment, and paired t-test showed striking differences(p<0.05). 3) The range of motion in shoulder abduction was increased with serise of treatment, and paired t-test showed striking differences(p<0.05). Conclusion : The gliding-mobilization increases the range of motion of the patient of adhesive capsulitis of the shoulder.

  • PDF

탄소복합재 접착공정을 위한 CFRP의 레이저 표면처리 기법의 적용 (Application of Laser Surface Treatment Technique for Adhesive Bonding of Carbon Fiber Reinforced Composites)

  • 황문영;강래형;허몽영
    • Composites Research
    • /
    • 제33권6호
    • /
    • pp.371-376
    • /
    • 2020
  • 접착강도는 표면처리 기술을 통해 향상시킬 수 있다. 가장 일반적인 방법은 기계적인 결합력을 향상시킬 수 있는 접착 표면의 변화이다. 본 연구는 접착면의 레이저 표면 처리가 기계적 결합력에 미치는 영향과 탄소섬유 강화 복합재료(CFRP)의 접착 결합에 대해 설명한다. 1064 nm의 레이저를 활용하여 표면 조도를 패턴화했다. 레이저 샷의 수, 패턴의 방향, 길이가 CFRP/CFRP 단일 조인트의 접착력에 미치는 영향을 인장 시험을 통해 조사했다. ASTM D5868에 따른 시험을 수행하였으며, 파단 후 손상된 표면을 분석하여 결합 메커니즘을 결정했다. 접착 강도의 증가를 위해서는 CFRP 표면에 최적화된 레이저 샷의 수와 조도 깊이가 구성되어야 한다. 인장방향에서의 전단응력을 고려할 때, 접착층의 파단 경로를 길어지게 하는 45°의 방향의 조도가 접착강도의 증가를 야기했다. 그러나 레이저에 의한 조도의 길이는 접착 강도에 크게 영향을 주지 못했다. 레이저를 이용한 접착면의 표면처리는 기계적 결합 메커니즘을 확보하고 CFRP 접착 조인트의 접착 강도를 향상시키는 적합한 방법이라는 결론을 도출할 수 있다. 레이저 처리를 이용한 이점을 완전히 이용하기 위해서는 최적화된 레이저 공정 변수에 대한 연구가 반드시 필요하다.

PDMS와 고분자 전해질 표면을 이용한 간편한 세포 패터닝 방법 (Facile Cell Patterning Based on Selectively Patterned Polydimethylsiloxane (PDMS) and Polyelectrolyte Surface)

  • 정헌호;송환문;황예진;황택성;이창수
    • KSBB Journal
    • /
    • 제24권6호
    • /
    • pp.515-520
    • /
    • 2009
  • This study presented facile method of cell patterning using fabricated PDMS patterns on polyelectrolyte coated surface. This basic principle is the fabrication of functional surface presenting two orthogonal surfaces such as cell adhesive and repellent properties. Cell adhesive surface was firstly fabricated with simple coating of polyelectrolyte multilayer. And then, the desired patterns of PDMS for the prevention of nonspecific binding of cells were transferred onto the previously formed thin film of polyelectrolyte multilayer. Thus, we could prepare novel functional surface simultaneously containing PDMS and polyelectrolyte region. As expected, the PDMS regions showed effective prevention of nonspecific binding of cell and the other region, exposed polyelectrolyte area, provided cell adhesive environment. The height of formed PDMS structure was about 100 nm. Based on this method, cell patterning can be successfully obtained with various pattern shapes and sizes. Therefore, we expect that this simple method will be useful platform technology for the development of cell chip, cell based assay system, and biochip.

유착성 관절낭염 환자에 대한 테이프 적용이 관절가동범위와 통증감소에 미치는 영향 (The Effects of Taping Therapy on the ROM and VAS in Adhesive Capsulitis)

  • 이문환;오성태;박래준
    • The Journal of Korean Physical Therapy
    • /
    • 제15권3호
    • /
    • pp.223-238
    • /
    • 2003
  • The purpose of this study was to assess the effectiveness of taping therapy for adhesive capsulitis patients. The subjects were consisted of 40, male 18, female 22, average age was 59 years old. To find out the effectiveness of taping therapy, we sampled 20 patients treated with H/P, electrical therapy and scapular pattern & hold-relax technique of PNF(control group), and 20 patients treated same as control group with taping therapy(experimental group). The results were as follow : 1. There was a statistical significance of shoulder flexion, abduction, external rotation and VAS in both group(P<0.05). 2. There was not statistical significance of shoulder flexion and external rotation(P>0.05), but abduction had a statistical significance between taping group and non-taping group(P<0.05). 3. VAS was observed a statistical significance between 3rd and 4th post treatment(P<0.05). These results are imply that taping therapy has a effectiveness of shoulder motion and VAS for adhesive capsulitis.

  • PDF

탄소나노튜브 함유 Solderable 도전성 접착제의 전기적/기계적 접합특성 평가 (Electrical and Mechanical Properties of CNT-filled Solderable Electrically Conductive Adhesive)

  • 임병승;정진식;이정일;오승훈;김종민
    • 반도체디스플레이기술학회지
    • /
    • 제10권4호
    • /
    • pp.37-42
    • /
    • 2011
  • In this paper, novel carbon nanotube (CNT)-filled Solderable electrically conductive adhesive (ECA) and joining process have been developed. To investigate the bonding characteristics of CNT-filled Solderable ECA, three types of Solderable ECAs with different CNT weight percent (0, 0.1, 1wt%) were formulated. For a joining process, the quad flat package (QFP) chip was used. The QFP chip had a size of $14{\times}14{\times}2.7$ mm and a 1 mm lead pitch. The test board had a Cu daisy-chained pattern with 18 ${\mu}m$ thick. After the bonding process, the bonding characteristics such as morphology of conduction path, electrical resistance and pull strength were measured for each formulated ECAs. As a result, the electrical and mechanical bonding characteristics for a QFP joints using CNT-filled ECA were improved about 10% compared to those of QFP joints using ECA without CNT.

Plasma arc light를 이용한 bracket 부착시의 전단결합강도와 파절양상의 유형 (Shear bond strength and adhesive failure pattern in bracket bonding with plasma arc light)

  • 유형석;오영근;이승연;박영철
    • 대한치과교정학회지
    • /
    • 제31권2호통권85호
    • /
    • pp.261-270
    • /
    • 2001
  • 본 연구의 목적은 bracket 부착시 광조사시간을 획기적으로 감소시킬 수 있는 plasma arc light의 임상적 유용성을 visible light 중합시의 전단결합강도와 접착파절양상과 비교해 봄으로써 평가해 보는데 있다. 사람의 상하악 소구치를 포매하여 만든 레진블럭시편에 광중합 접착제인 Transbond$^{\circledR}$를 사용하여 수종의 bracket을 각각의 조건에 따라 부착한 후 만능 물성시험기를 이용하여 전단결합강도를 측정하고, 접착파절양상을 stereoscope을 이용하여 관찰하여 다음과 같은 결과를 얻었다. 1. Plasma arc light를 이용한 수종의 bracket 접착시 metal bracket과 ceramic bracket의 전단결합강도는 임상적으로 사용하기에 충분한 값을 나타내었으며, resin bracket 경우 다른 bracket 비해 전단결합강도가 현저히 작은 값을 나타내었지만 임상적으로 사용이 가능한 값을 나타내었다. 2. Visible light를 이용한 metal bracket의 광중합시 광조사시간에 따른 전단결합강도는 광조사 시간에 따른 유의한 차이를 보이지 않았으며, 임상적으로 사용하기에 충분한 강도를 나타내었다. 3. Plasma arc light를 이용한 수종의 bracket 접착시 접착제 잔류지수를 통해 접착파절양상을 관찰한 결과, metal bracket과 resin bracket 경우 bracket기저면에 접착제가 반 이상 남아 있지 않은 경우가 많았으며, ceramic bracket의 경우 bracket기저면에 접착제가 반 이상 남아 있는 경우가 많았다. 4. Metal bracket의 부착시 plasma arc light를 2초간 광조사한 군과 visible light를 10초간 광조사한 군의 전단결합강도와 접착파절양상을 비교시 유의한 차이를 보이지 않았다. 6. Plasma arc light를 이용한 광중합시 광조사 거리에 따른 전단결합강도는 거리가 증가할수록 감소하였다. 이상의 실험 결과는 plasma arc light를 이용한 bracket의 접착시 전단결합강도 저하의 우려 없이 임상적으로 사용 가능함을 시사한다.

  • PDF

Al 판재의 Adhesion Bonding에 미치는 전처리 영향 (Effects of Pretreatment on the Adhesive Bonding of Aluminium Plate)

  • 한성호;김만;장도연;노병호
    • 한국표면공학회지
    • /
    • 제25권2호
    • /
    • pp.97-102
    • /
    • 1992
  • Transimission electron microscope(TEM)/ultramicrotomy were used to characterize the detailed surface morphology of 2024-T3 Al alloy surfaces prepared by various pretreatment process. It was found that, for good and superior initial adhesive strength and durability, chemically pretreated substrates appeared essential. The film morphology developed after CSA etching treatment, ass revealed by TEM, suggested the present of irregular cell pattern with finely separated whisker-like protrusion with was responsible for increase of bond strength.

  • PDF

상아세관의 주행방향에 따른 상아질 접착제의 침투양상에 대한 공초점레이저주사현미경 연구 (EFFECT OF DENTINAL TUBULES ORIENTATION ON PENETRATION PATTERN OF DENTIN ADHESIVES USING CONFOCAL LASER SCANNING MICROSCOPY)

  • 김동준;황윤찬;김선호;오원만;황인남
    • Restorative Dentistry and Endodontics
    • /
    • 제28권5호
    • /
    • pp.392-401
    • /
    • 2003
  • The purpose of this study was to evaluate the penetration pattern of dentin adhesives according to the orientation of dentinal tubules with confocal laser scanning microscopy. Specimens having perpendicular. parallel and oblique surface to dentinal tubules were fabricated. The primer of dentin adhesives (ALL $BOND^{\circledR}{\;}2,{\;}CLEARFIL^{TM}$ SE BOND and PQ1) was mixed with fluorescent material. rhodamine B isothio-cyanate (Aldrich Cherm. CO., Milw., USA), It was applied to the specimens according to the instructions of manufactures. The specimens were covered with composite resin (Estelite, shade A2) and then cut to a thickness of 500$\mu\textrm{m}$ with low speed saw (Isomet^{TM}, Buehler. USA). The adhesive pattern of dentin adhesives were observed by fluorescence image using confocal laser scanning microscopy. The results were as follows. 1. For the groups with tubules perpendicular to bonded surface. funnel shape of resin tag was observed in all specimen. However. resin tags were more prominent in phosphoric acid etching system (ALL $BOND^{\circledR}$ 2 and PQ1) than self etching system ($CLEARFIL^{TM}$ SE BOND). 2. For the groups with tubules parallel to bonded surface. rhodamine-labeled primer penetrated into peritubular dentin parallel to the orientation of dentinal tubules. But rhodamine-labeled primer of PQ1 diffused more radially into surrounding intertubular dentin than other dentin adhesive systems. 3. For the groups with tubules oblique to bonded surface. resin tags appeared irregular and discontinuous. But they penetrated deeper into dentinal tubules than other groups.

소아의 유착성 장폐쇄증에 대한 임상적 고찰 (Clinical Analysis of Adhesive Ileus in Children)

  • 이종재;윤현조;정연준;김재천
    • Advances in pediatric surgery
    • /
    • 제7권2호
    • /
    • pp.118-125
    • /
    • 2001
  • The effectiveness of operative and non-operative management for postoperative adhesive ileus in children has been discussed. This study reviews the clinical characteristics and the treatment consequences of adhesive ileus in our institution. Department of Surgery of Chunbuk National University Hospital, retrospectively. A total of 62 cases of post-operative small bowel obstruction treated between January 1975 and December 1998 under the 15 years of age are included in this study. The patients were divided into two groups, operative(n=26) and non-operative(n=36) groups. The prevalent age was between 11 and 15 years(28 cases; 45.2 %), and the most common previous operation was appendectomy(28 cases; 45.2 %). The most common operative procedures were adhesiolysis(17 cases; 65.4 %). The interval between admission and operation was 1 day in 11 cases(42.3 %). The most common site of adhesion was the ileum in 13 cases(50.0 %) and band constriction was the most frequent pattern(8 cases; 30.8 %). Intestinal resection was significantly high in delayed operations of more than four days, in the patients with three or more classical signs of strangulation(fever, tachycardia, leukocytosis, abdominal pain, rebound tenderness), and in the cases of complete obstruction on plain abdomen film(p < 0.05). In conclusion, operation should be considered in cases with three or more signs of strangulation, no clinical improvement for over four days of conservative treatment, and signs of complete obstruction on plain abdomen film during the observation periods.

  • PDF