• 제목/요약/키워드: adhesive material

검색결과 750건 처리시간 0.027초

전도체 형성 방법에 따른 유무기 복합재료 안테나의 고주파 특성 (Microwave Properties of Organic-inorganic Composite Material Antenna with Various Fabrication Method of Conduction Material)

  • 박상훈;성원모
    • 한국전기전자재료학회논문지
    • /
    • 제19권9호
    • /
    • pp.832-837
    • /
    • 2006
  • Antennas were fabricated by physical(adhesive) and chemical(deposition+plating) method on organic-inorganic composite material. And antennas were measured dielectric constant and gain. Dielectric constant of antennas were fabricated by physical method was decreased with increase of adhesive tape thickness and number of conduction material composition. But antennas were fabricated by chemical method was reached to 90 % of dielectric material. Gain of antennas were fabricated by physical method was decreased with increase of adhesive tape thickness. But they were unrelated with conduction material composition. The other side antennas were fabricated by chemical method excelled more 0.8 dBic than antennas were fabricated by physical method in gain of antenna. Finally, chemical method can expect excellent product process because it can produce smaller size, higher gain and elimination of many handworks.

강재의 마감재로 사용된 도료별 비래염분 부착량 평가 (An Evaluation on Adhesive Weight of Incoming Salt by Paint used for Finishing Material of Steel)

  • 조규환;이영준;김우재;박동천
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.177-178
    • /
    • 2013
  • Steel structures of the seaside area are naturally led to surface corrosion due to incoming salt. Signature measures for this are to replace steel with steel material with a high corrosion-resistance and to block salt and other deteriorative factors beforehand through finishing work such as surface coating. However, the variety in steel materials, finishing type, and construction methods makes adhesive weight of incoming salt different depending on each type. For this research, measurement results derived from an enhancement experiment on artificial incoming salt adhesive to 4 steel finishing types and 2 material types identified a difference of adhesive weight by each sampler.

  • PDF

소독제가 개인용 트레이와 실리콘 인상재의 접착력에 미치는 영향에 대한 연구 (EFFECT OF DISINFECTION OF CUSTOM TRAY MATERIALS ON ADHESIVE PROPERTIES OF SEVERAL IMPRESSION MATERIAL SYSTEMS)

  • 김정한;정창모;전영찬;황의성
    • 대한치과보철학회지
    • /
    • 제34권2호
    • /
    • pp.290-298
    • /
    • 1996
  • The effects of impression tray disinfection procedures on the bond strength of impression-material adhesive to two of types resin trays were evaluated with a tensile test. Autopolyme-rizing acrylic resin was formed into 1x1x1 cm cubes. A hook was attached to each cube with autopolymerizing acrylic resin. Perforated trays were fabricated with stops to maintain an even 3 cm of impression material over the resin block. Hook on the opposite side of the perforated tray permitted attachment of the metal plate to a mechanical testing machine. Before adhesive was applied, one third of the resin specimens were immersed in a 5% sodium hypochlorite solution : one third in a 2% glutaradehyde solution, and one third were kept in the "as fabricated" condition. Three products(Perfect ups, Exafine, and Exp-ress) of polyvynil siloxane impression material-adhesive system were evaluated. The resin-impression material-metal plate couples were attached to a mechanical testing machine and tensile forces were applied at a separation rate of 10 centimeters per second. The results were as follows; 1. Both disinfectant and adhesive had effects on bond strength values, but adhesive had more effect than disinfectant(p<0.01). However, there was no interaction between dinin-fectant and adhesive(p>0.01). 2. Mean bond strength values for the Perfect materials were about 85% less than that of the Exafine or the Express materials. However, there was no stastically significant difference between the mean bond strength values of the Exafine materials and the Express materials(p>0.05). 3. The use of disinfectants produced significant reduction in bond strength values(p<0.05). But there was no stastically significant difference between the mean bond strength values of the groups treated with disinfectants(p>0.05).

  • PDF

피혁봉재에 있어서 부직포 접착심지의 접착방법에 관한 연구 (A Study on the Adhesive Condition of the Nonwoven Fabrics in Sewing of the Leather)

  • 김영자
    • 한국의류학회지
    • /
    • 제5권2호
    • /
    • pp.35-40
    • /
    • 1981
  • This study aims at finding appropriate adhesive conditions with special regard the material of 'fusible padding cloth inter ling' was frequently used for leather. As for leather material, pig suede, sheep suede were selected and drum dyed, cow split, napa have also been used. Mixed spinning non-woven fabric (polyester $50\%$, nylon $50\%$) were used as for padding cloth. Experimental appearance has been observed under the following adhesive conditions: Temperature of press were devided four levers; $120^{\circ}C$, $130^{\circ}C$, $140^{\circ}C$, $150^{\circ}C$, respectively. Adhesive time has been limited 5, 10, 15 second each. And the pressure has been conditioned as $0.2kg/cm^2$ continuously. After all this experiment, it was discovered that the material which had long contact with low temperature conditions has similar adhesive power to material that has short contact with high temperature conditions. There is a great difference according to the leather's dying process, the finishing method of the cloth, and the part of leather surface. The best condition for suede are $140^{\circ}C$, $150^{\circ}C$, at 10 seconds. and for D/D, NAPA, $130^{\circ}C$, at 10 seconds. Although the conditions of $150^{\circ}C$, at 15 seconds was possible for split, the process time can be shortened according to the increase of temperature.

  • PDF

접착제의 두께와 열 응력에 따른 조인트의 토크 특성 (Effects of the Adhesive Thickness and Residual Thermal Stress on the Torque Capacity of Turbular Single Lap Joints)

  • 최진호;이대길
    • 대한기계학회논문집
    • /
    • 제16권10호
    • /
    • pp.1841-1852
    • /
    • 1992
  • 본 연구에서는 Fig.1과 같이 원형튜브 형태로된 시편과 실린더 형태의 시편을 Single Lap Joint의 형태로 접착하여 접착제의 두께에 대한 정적 비틀림 강도특성을 실험하였으며, 접착제의 경화시 외부에서 가해주는 열로 인한 열 잔류응력의 영향에 대한 연구를 수행하였다. 또한 이론적인 해석과 상용 프로그램인 ANSYS를 이용하여 유한요소해석을 병형하여 실험결과와 비교 검토하였다.

전도성 접착제의 열경화 응력에 대한 해석 (Thermal Ratchetting of the Conductive Adhesives Joints Subjected to the Thermal Cycles)

  • 박주혁;서승호
    • 한국마이크로전자및패키징학회:학술대회논문집
    • /
    • 한국마이크로전자및패키징학회 2002년도 춘계 기술심포지움 논문집
    • /
    • pp.208-213
    • /
    • 2002
  • When a thermoset conductive adhesive joints are subjected to the thermal cycles, the thermal stresses are developed around the joints. Most of in-plane, hi-axial components of these residual stresses induces large tensile peel stresses and weakens adhesive joints. Also these stresses vary with thermal cycles, and result in thermal fatigue loading and debonding propagation. In this study, the thermal ratchetting effect in conductive adhesive joints are evaluated by the finite element analysis with the viscoelastic material model. In order to Investigate the relationship between thermal ratchetting and glass transition temperature, the mathematical material model has been developed experimentally by dynamic mechanical analysis. These material models are implemented to the finite element analysis with thermal loading cycles. And the stress profiles around the conductive adhesive joints are calculated. It has been observed that the thermal ratchetting occurs when the maximum temperature of thermal cycles is above the glass transition temperature. The peel and shear stress components increase as the thermal loading time increases. This will contributes to thermal fatigue fracture of the joints.

  • PDF

이종골 이식시 Fibrin adhesive의 사용이 골 재생에 미치는 영향에 관한 조직병리학적 연구 (A Histo-Pathological Study of Effect on Bone Regeneration with Fibrin Adhesive)

  • 고영우;임성빈;정진형;이종헌
    • Journal of Periodontal and Implant Science
    • /
    • 제33권1호
    • /
    • pp.91-102
    • /
    • 2003
  • Several effective treatment methods and materials have been developed for the treatment of furcation involvement. Currently, the combination of guided tissue regeneration (GTR) and bone grafts is the most commonly prescribed method of treating furcation involved defects. But because these cases often present with poor accessibility, placement of the membrane may be difficult and consequently, clinically impractical. In this study, the alveolar bone healing patterns of adult beagle dogs presenting with alveolar bone destruction treated by one of two methods - treatment using solely bone allografts (BBP(R)), or treatment using bone allografts (BBP(R)) stabilized by a fibrin adhesive - were comp ared. The effects of the fibrin adhesive on the initial stabilization of the newly formed bone, subsequent regeneration of bone, and the feasibility of the clinical application of the fibrin adhesive were analyzed. The results of the study were as follows: 1. Clinical signs of inflammation at the 4-8 week interval were not observed: but signs of mild inflammation were histologically observed at the 4-week interval. 2. Allografts stabilized by fibrin adhesive showed good bone formation, whereas defects treated with only the allograft material showed incomplete alveolar bone regeneration. 3. Allografts stabilized by fibrin adhesive showed a decrease in the amount old bone with a concurrent increase in the formation of new lamellar bone four weeks post-op, whereas defects treated with only the allograft material showed no new lamellar bone formation at the same interval. 4. In detects treated with only the allograft material, the defective area was filled with connective tissue 8-weeks post-op, whereas fibrin adhesive stabilized allografts showed viable connections between the original bone and the newly formed bone, in addition to neovascularization 8-weeks post-op. The results of this study show that concurrent use of fibrin adhesive materials can stabilize the allograft material and aid in new bone formation Although the stability of fibrin adhesives fall short of the results achievable by GTR membranes, in cases presenting with poor accessibility that contraindicate the use of membranes, fibrin adhesive materials provide a viable and effective alternative to graft stabilization and new bone formation.

Comparative study of abutment screw loosening with or without adhesive material

  • Arshad, Mahnaz;Shirani, Gholamreza;Refoua, Sina;Yeganeh, Mohammadreza Rahimi
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권2호
    • /
    • pp.99-103
    • /
    • 2017
  • PURPOSE. The purpose of this study was to achieve more retention and stability and to delay or prevent screw loosening. MATERIALS AND METHODS. Twenty implants (Implantium 3.4 mm, Dentium, Seoul, Korea) were divided into 2 groups (n = 20). In the first group, an adhesive material was applied around the screw of the abutments (test group). In the second group, the screws are soaked in saliva (control group). All the screws were torqued under 30 N/cm, Then, the samples were gone through a cyclic fatigue loading process. After cyclic loading, we detorqued screws and calculated detorque value. RESULTS. In comparison with the control group, all the implant screws in the test group were smeared with the adhesive material, showing significant higher detorque value. CONCLUSION. There are significantly higher detorque values in the group with adhesive. It is recommended to make biocompatible adhesive to reduce screw loosening.

핑거공차가 휨강도성능에 미치는 영향 (Effect of Finger Dimensions of Tip and Root Widths on Bending Strength Properties)

  • 변희섭;류현수;안상열;이균필;박한민;김종만
    • 한국가구학회지
    • /
    • 제12권2호
    • /
    • pp.1-10
    • /
    • 2001
  • As finger joint method has a high rate of yield and high strength and ease in working, it has been widely used as an end joint method for solid wood and wood based-material. Therefore, we end-joined the material of Pinus densiflora, Quercus variabilis and populus euramericana with polyvinyl acetate adhesive and resorcinol phenol resin adhesive. The effect of difference (0, 0.15, 0.3, 0.45mm) between the dimensions of tip width and root width of the finger (DTRW) on bending strength properties was as follows: 1. In the case of polyvinyl acetate adhesive, DTRW had no effect on bending modulus of elasticity(MOE) and modulus of rupture(MOR) of the three kinds of species, because their bonding layers were destroyed by slippage, not their woody parts. 2. In the case of resorcinol phenol resin adhesive, the material of Quercus variabilis showed an optimal result at 0.15 or 0.3 of DTRW, while the poplar did at 0 of DTRW 3. The differences in efficiency ratio of bending MOR of populus euramericana, Pinus densiflora and Quercus variabilis species according to the kind of adhesive were 13-29%, 23-30% and 45-53%, respectively.

  • PDF

타닌산-전이 금속-고분자로 구성된 젤의 단일 단계 합성과 점착제로의 이용 (One-step Fabrication of a Tannic Acid-Transition Metal-Polymer Gel as a Pressure-Sensitive Adhesive)

  • 이재홍;이경문;최시영
    • Korean Chemical Engineering Research
    • /
    • 제58권2호
    • /
    • pp.176-183
    • /
    • 2020
  • 이 연구에서는 작은 유기 분자 말단의 하이드록실기와 전이 금속 사이의 배위 결합을 통해 고분자와 유사하게 연결된 복합체를 제작하고, 점착 부여제를 추가하여 해당 물질의 점착제로의 사용 가능성을 확인하였다. 점착제 합성에 사용한 타닌산(tannic acid, TA)은 하이드록실기를 풍부하게 보유하고 있어 전이 금속과는 배위 결합이 가능하고 친수성 고분자와는 수소 결합이 가능하다. 위의 성질을 이용하여 타닌산과 전이 금속, 고분자 세 가지 성분을 한 번에 간단히 섞어 기판에 잘 펴지며 점착 능력을 보유한 특별한 유변 물성을 가지는 물질을 제작하였다. 합성에 사용한 전이 금속의 종류(Fe3+, Ti4+), 고분자의 종류, 처리 조건 등에 따른 유변 물성의 변화를 확인하는 과정을 통해 점착제로 사용하기에 가장 적합한 성분의 조합을 발견하였으며, 인체에 무해하며 높은 응집력과 접착력을 보유한 다목적 점착제로의 사용 가능성을 확인하였다.