• 제목/요약/키워드: additional cooling

검색결과 188건 처리시간 0.035초

분리막을 이용한 주거용 제습공조시스템의 LCC 분석 (LCC Analysis of Residential Dehumidifying Air Conditioning System using Thin Separation Membrane)

  • 정용호;박성룡
    • 설비공학논문집
    • /
    • 제30권1호
    • /
    • pp.10-16
    • /
    • 2018
  • The climate of summer in Korea is quite hot and humid. Many studies have been carried out to reduce the energy required for operating a dehumidifier. The dehumidifier is mainly connected to the cooling system since it operates in the summer. Conventional dehumidification methods often require additional cooling and energy for dehumidification. In this study, a system for increasing the efficiency by applying a membrane was analyzed. Its energy saving effect was analyzed when it was applied to residential buildings. Economic efficiency was also evaluated. As a result of this study, 9.0% energy savings were achieved for residential buildings. The investment recovery period was 28.9 years. Such long investment recovery period was because the initial investment cost was excessive and annual energy saving only appeared in the summer.

FARADAY ROTATION OBSERVATIONS OF MAGNETIC FIELDS IN GALAXY CLUSTERS

  • CLARKE TRACY E.
    • 천문학회지
    • /
    • 제37권5호
    • /
    • pp.337-342
    • /
    • 2004
  • The presence of magnetic fields in the intracluster medium in clusters of galaxies has been revealed through several different observational techniques. These fields may be dynamically important in clusters as they will provide additional pressure support to the intracluster medium as well as inhibit transport mechanisms such as thermal conduction. Here, we review the current observational state of Faraday rotation measure studies of the cluster fields. The fields are generally found to be a few to 10 $\mu$G in non-cooling core clusters and ordered on scales of 10 - 20 kpc. Studies of sources at large impact parameters show that the magnetic fields extend from cluster cores to radii of at least 500 kpc. In central regions of cooling core systems the field strengths are often somewhat higher (10 - 40 $\mu$G) and appear to be ordered on smaller scales of a few to 10 kpc. We also review some of the recent work on interpreting Faraday rotation measure observations through theory and numerical simulations. These techniques allow us to build up a much more detailed view of the strength and topology of the fields.

COCOA: The CO-evolution of cluster COres and the AGNs of central galaxies

  • Baek, Junhyun;Jung, Taehyun;Tremou, Evangelia;Sohn, Bong-Won;Chung, Aeree
    • 천문학회보
    • /
    • 제38권2호
    • /
    • pp.49.2-49.2
    • /
    • 2013
  • We report preliminary results from a radio study of central galaxies in cool and non-cool core clusters. A cooling flow is expected to rapidly form in the center of galaxy clusters unless additional heating mechanisms such as merging with sub clusters are at work. It has been suggested that cool flows can feed the AGN in the central galaxies, increasing their power. On the other hand, the AGN feedback can also affect the surrounding medium, heating back up the gas in the cluster core region. In this study, we investigate the co-evolution of cool flows and the AGN of galaxies located in the cluster center. For this study, we have selected 13 radio bright central galaxies from clusters with a range of cooling time scale. In this work, we present results of our recent observations using the Korean VLBI Network. We discuss the properties of the sample in radio and other wavelengths.

  • PDF

마이크로가속도계의 열응력에 대한 유한요소해석 (Finite Element Analysis for Thermal Stresses of Microaccelerometers)

  • 김옥삼
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2000년도 춘계학술대회 논문집(Proceeding of the KOSME 2000 Spring Annual Meeting)
    • /
    • pp.100-104
    • /
    • 2000
  • This paper deals with finite element analyses of residual stresses causing popping up which are induced in micromachining processes of a mcroaccelerometers. After heating the tunnel gap up to 100 degree and get it through the cooling process and the additional bean up to 80 degree and get is through the cooling process. We learn the thermal internal stress of each shape and compare the results with each other after heating the tunnel gap up to 400 degree during the Pt deposition process. We want to seek after the real cause of this pop up phenomenon and diminish this by change manufacturing processes of microaccelerometer by electrostatic force.

  • PDF

선상가열시 강의 상변태를 고려한 개선된 고유변형도 기반의 등가하중법 (Developed Inherent Strain Method Considering Phase Transformation of Mild Steel in Line Heating)

  • 하윤석;장창두
    • 대한조선학회논문집
    • /
    • 제41권6호
    • /
    • pp.65-74
    • /
    • 2004
  • The inherent strain method is known to be very efficient in predicting the deformation of steel plate by line heating. However, in the actual line heating process in shipyard, the rapid quenching changes the phase of steel. In this study, In order to consider additional effects under phase transformation, inherent strain regions were assumed to expand. Also, when calculating inherent strain, material properties of steel in heating and cooling are applied differently considering phase transformation. In this process, a new method which can reflect thermal volume expansion of martensite is suggested.8y the suggested method, it was possible to predict the plate deformations by line heating more precisely.

SOI웨이퍼를 이용한 마이크로가속도계 센서의 열응력해석(I) (Analyses Thermal Stresses for Microaccelerometer Sensors using SOI Wafer(I))

  • 김옥삼
    • 동력기계공학회지
    • /
    • 제5권2호
    • /
    • pp.36-42
    • /
    • 2001
  • This paper deals with finite element analyses of residual stresses causing popping up which are induced in micromachining processes of a microaccelerometer sensors. The paddle of the micro accelerometer sensor is designed symmetric with respect to the direction of the beam. After heating the tunnel gap up to 100 degree and get it through the cooling process and the additional beam up to 80 degree and get it through the cooling process. We learn the thermal internal stresses of each shape and compare the results with each other, after heating the tunnel gap up to 400 degree during the Pt deposition process. Finally we find the optimal shape which is able to minimize the internal stresses of microaccelerometer sensor. We want to seek after the real cause of this pop up phenomenon and diminish this by change manufacturing processes of microaccelerometer sensor by electrostatic force.

  • PDF

냉동기 부착형 전도냉각식 Cryostat의 설계 및 제작 (Design and Fabrication of a Conductively Cooled Cryostat by Cryocooler)

  • 배준환;심기덕
    • 전기학회논문지
    • /
    • 제56권11호
    • /
    • pp.1921-1924
    • /
    • 2007
  • In order to measure the superconducting transition temperature, the critical current and the alternating current(AC) loss on short samples of high temperature superconductor, a cryocooler cooled cryostat has been designed and built. Two closed-cycle coolers provide cooling with an ultimate sample temperature below 16K. Temperature regulation is provided by 50W of electrical heater that opposes the cooling power from the cold heads. Temperature control feedback is by means of a cernox temperature sensor co-located with the heaters on the second stage of the cold head. Additional temperature sensors are located on the sample mount(B1), on the CVI cold head(B2) and on the Dakin cold head(B3). AC losses on the sample high temperature superconductor were measured at 30K so that the developed device performance was evaluated. In this paper, the design, fabrication and test results on the cryocooler cooled cryostat are presented.

건식공정 바텀애시 경량 잔골재의 입도 조건에 따른 모르타르의 특성 (Properties of Mortar Using Lightweight Fine Aggregate Made by Bottom Ash Discharged Air Cooling Process according to Grading)

  • 최홍범;선정수;유재성;이무;최덕진;김진만
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 추계 학술논문 발표대회
    • /
    • pp.53-54
    • /
    • 2014
  • This study evaluates engineering properties of mortar using lightweight fine aggregate made by bottom ash discharged air cooling process according to grading. Then we confirm possibility of use as lightweight fine aggregate. Consequently, Mix using bottom ash need additional examination for a change with the passage of time of flow. Also, mix of S indicates similar compressive strength with mix of Plain and 16% decrease of unit weight compared to mix of Plain; while mix of B indicates 10% decrease of compressive strength and 16% decrease of unit weight. Therefore, this study shows that mix of S and B is superior compared with other mix.

  • PDF

Computational Fluid Dynamics를 활용한 점/접착 생산 공정 내 Jacketed Vessel 설계 최적화 (Optimization of Plain Jacked Vessel Design in Adhesive Production Process Using Computational Fluid Dynamics)

  • 주종효;박현도;조형태;김정환
    • 공업화학
    • /
    • 제31권6호
    • /
    • pp.596-602
    • /
    • 2020
  • 점/접착제 생산 공정은 배합 과정에서 mineral insulated (MI) cable을 통해 내부 용액을 76 ℃까지 가열 및 혼합 후 제품 출하를 위해 30 ℃까지 상온 냉각을 진행한다. MI cable을 이용한 반응기의 경우, 냉각시간이 평균 10 h 소요되어 생산효율이 낮은 문제점이 있지만, jacketed vessel을 설치하면 위의 문제를 효과적으로 해결할 수 있다. 그러나 jacketed vessel의 종류가 다양해 jacket을 설치하기 전, 배합 공정조건에 적합한 종류를 찾아야 한다. 본 연구에서는 생산효율에 영향을 주는 냉각시간을 최소화하기 위해 computational fluid dynamics (CFD)를 이용하여 jacket 종류에 따른 냉각시간을 비교해 공정에 적합한 jacketed vessel 모델을 개발하고, 점/접착제 생산 공정에 최적화된 jacketed vessel을 설계하였다. 연구 결과, jacket의 높이가 같을 때, half-pipe coil jacket보다 plain jacket의 냉각 성능이 32.7% 더 우수하였고, plain jacket에 60% spiral baffle을 설치하여 냉각 공정에 이용할 경우 냉각시간을 80.4%, 작업시간을 25.1% 단축 가능하다.

0.36Mn이 함유된 구상흑연주철의 냉각조건에 따른 기계적 거동 고찰 (Effect of Post Solidification Cooling Condition on the Mechanical Behavior of the 0.36Mn Containing Ductile Iron)

  • 김석동;김성규
    • 한국주조공학회지
    • /
    • 제41권4호
    • /
    • pp.349-356
    • /
    • 2021
  • 우수한 기계적 성질과 가격경쟁력을 갖는 구상흑연주철 합금 개발을 위해 Cu와 Sn을 소량 첨가한 고 Mn 구상흑연주철의 응고 후 냉각조건에 따른 미세조직과 기계적 특성을 분석하였다. 첨가원소인 Cu와 Sn의 경우 펄라이트 형성 촉진을 통한 인장특성 향상을 위해 선택하였다. 또한 물성에 미치는 냉각속도의 영향을 확인하기 위해, Mg 처리된 다양한 조성의 합금을 블록시편에 주입한 후 주형 내 냉각과 800℃에서 주형 해체 후 공랭의 두 가지 냉각 조건을 비교분석하였다. 주형 내 냉각 시편의 경우, 펄라이트 분율은 27-44%, 인장강도와 연신율은 각각 513-568N/mm2와 10.4-14.3%로 나타났다. 반면, 이른 형해체 공랭 시편의 경우에는 펄라이트 분율은 77~85%, 인장강도와 연신율은 각각 728~758N/mm2와 3.2~6.0% 이었다. 결론적으로, 소량의 Cu 및 Sn 함유 Mn 구상흑연주철의 공랭 시 괄목할만한 인장강도와 연신율의 증가를 확인할 수 있었다.