• 제목/요약/키워드: actual response

검색결과 1,256건 처리시간 0.025초

THEORY OF BACKGROUND NOISE CANCELLATION ON PREDICTION OF RESPONSE PROBABILITY DISTRIBUTION FOR AN ARBITRARY SOUND WALL SYSTEM AND ITS APPLICATION TO ACTUAL SOUND WALL SYSTEMS

  • Ohta, M.;Takaki, N.
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1994년도 FIFTH WESTERN PACIFIC REGIONAL ACOUSTICS CONFERENCE SEOUL KOREA
    • /
    • pp.740-745
    • /
    • 1994
  • In the actual situation of measuring the environmental noise, it is very often that only the resultant phenomenon fluctuation contaminated by the additional noise of arbitrary distribution type can be observed. Furthermore, the observed data is usually given in a sound level form the purpose of estimating only the undisturbed objective output response, some estimation method is necessary to reasonably remove the effect of the above additional noise. In this paper, first, a mathematical model of arbitrary sound insulation systems is introduced in the form of a linear system on intensity scale, by using the well-known additive property of energy quantities. Next, some estimation method of the output response under the existence of background noise is derived. Then, based on the expression of the above estimation method, a new prediction method of only the output response probability function form for arbitrary sound insulation systems without. a background noise is proposed by use of observed data contaminated by a background noise. Finally, the effectiveness of the proposed method is confirmed experimentally too by applying it to the actual various type sound wall systems.

  • PDF

Computing input energy response of MDOF systems to actual ground motions based on modal contributions

  • Ucar, Taner
    • Earthquakes and Structures
    • /
    • 제18권2호
    • /
    • pp.263-273
    • /
    • 2020
  • The use of energy concepts in seismic analysis and design of structures requires the understanding of the input energy response of multi-degree-of-freedom (MDOF) systems subjected to strong ground motions. For design purposes and non-time consuming analysis, however, it would be beneficial to associate the input energy response of MDOF systems with those of single-degree-of-freedom (SDOF) systems. In this paper, the theoretical formulation of energy input to MDOF systems is developed on the basis that only a particular portion of the total mass distributed among floor levels is effective in the nth-mode response. The input energy response histories of several reinforced concrete frames subjected to a set of eleven horizontal acceleration histories selected from actual recorded events and scaled in time domain are obtained. The contribution of the fundamental mode to the total input energy response of MDOF frames is demonstrated both graphically and numerically. The input energy of the fundamental mode is found to be a good indicator of the total energy input to two-dimensional regular MDOF structures. The numerical results computed by the proposed formulation are verified with relative input energy time histories directly computed from linear time history analysis. Finally, the elastic input energies are compared with those computed from time history analysis of nonlinear MDOF systems.

진동응답 계측결과를 이용한 기진력의 추정 (Estimation of Excitation Forces from Measured Response Data)

  • 한상보
    • 대한기계학회논문집
    • /
    • 제19권1호
    • /
    • pp.45-60
    • /
    • 1995
  • It is attempted to estimate excitation force of a linear vibratory system using measured vibration responses. The excitation force is estimated from the relationship between the vibration response and system characteristic matrices which are extracted from both the mathematical model of the system and actual response in contrast to the usual approach of inverting the frequency response matrices. This extraction scheme is based on the fact that the vibration response can be expressed in term of linear combination of frequency domain modal vectors defined as mutually orthonormal basis vectors in frequency domain. The extracted frequency domain basis vectors are very stable in computational manipulation. It is found that the estimated excitation force is in good agreement with actually measured force except at the natural frequencies the structure, which is the common feature still to be overcome by the research efforts in this area. From the results of this paper, this disagreement is considered to come from the discrepancy between the model and actual value of the mass, damping and stiffness of the structure.

실내디자인 프로젝트 매니지먼트에 관한 고찰 (A Study on the Interior Design Project Management)

  • 김상근;유수상
    • 한국실내디자인학회논문집
    • /
    • 제16호
    • /
    • pp.91-97
    • /
    • 1998
  • We have been taught designing process throughout the long period of education. Nevertheless it is hard to make a quick response to actual project However if we are faced with the actual project as a design professionals it is hard to cope with the project at once nothing but ambiguous idea. Also most of designers concemed with the project do not recognize who are responsible for what. Consequently this attitude delays the entire operation causing waste of time and resources and leads to the unacceptable result. This research is designed therefore to come up with the projects control process that is practical enough to encourage interior designers as well as design firms to face actual projects with shrewd response. There is of course no single right answer to certain design projects. But at least there should be a guideline which shows designers more reasonale systematic ways to control design project lest they should waste time and cost : a guideline as an assistance for successful design result.

  • PDF

Simulation of earthquake records using combination of wavelet analysis and non-stationary Kanai-Tajimi model

  • Amiri, G. Ghodrati;Bagheri, A.
    • Structural Engineering and Mechanics
    • /
    • 제33권2호
    • /
    • pp.179-191
    • /
    • 2009
  • This paper is aimed at combining wavelet multiresolution analysis and nonstationary Kanai-Tajimi model for the simulation of earthquake accelerograms. The proposed approach decomposes earthquake accelerograms using wavelet multiresolution analysis for the simulation of earthquake accelerograms. This study is on the basis of some Iranian earthquake records, namely Naghan 1977, Tabas 1978, Manjil 1990 and Bam 2003. The obtained results indicate that the simulated records preserve the significant properties of the actual accelerograms. In order to investigate the efficiency of the model, the spectral response curves obtained from the simulated accelerograms have been compared with those from the actual records. The results revealed that there is a good agreement between the response spectra of simulated and actual records.

대스팬 지붕구조물의 등가정적 풍하중 산정에 관한 연구 (A study on the equivalent static wind load estimation of large span roofs)

  • 김대영;김지영;김한영;이명호;김상대
    • 한국공간정보시스템학회:학술대회논문집
    • /
    • 한국공간정보시스템학회 2004년도 춘계 학술발표회 논문집 제1권1호(통권1호)
    • /
    • pp.245-251
    • /
    • 2004
  • This paper discuss the conditionally sampled actual wind pressure distributions causing peak quasi-static wind loads in the large span roofs using the wind pressures at many locations on dome models measured simultaneously in a wind tunnel. The actual extreme pressure distributions are compared itk load-response-correlation (LRC) method and the quasi-steady pressure distributions. Based on the results, the reason for the discrepancy in the LRC pressure distribution and the actual extreme pressure distribution are discussed. Futhermore, a brief discussion is made of the equivalent static wind load estimation for the large span roofs.

  • PDF

표준형 및 속동형 스프링클러헤드의 반응시간지수와 소화성능 (Response Time Index and Suppression Capability of Standard and Quick Response Sprinkler Head)

  • 정길순;이병곤
    • 한국안전학회지
    • /
    • 제13권4호
    • /
    • pp.59-70
    • /
    • 1998
  • In this study, response time index(RTI) of standard and quick response type sprinkler head are measured and compared through ramp and plunge test in heated wind tunnel. Also discharge rate and water distribution, actual delivered density(ADD), fire test with wood cribs are performed to compare the fire suppression capability and the operation time and temperature between standard and quick response type sprinkler head.

  • PDF

불만고객에 대한 기업의 실제적 반응이 공정성과 신뢰·만족에 미치는 영향 (A Study on the Effects of Company's Actual Response to Customer Complaints on Justice, Trust and Satisfaction)

  • 지희진
    • 한국산학기술학회논문지
    • /
    • 제16권6호
    • /
    • pp.3829-3836
    • /
    • 2015
  • 기업의 실제적인 불만처리 반응은 불만 고객의 이탈을 줄이는 기업의 중요한 성공요인이다. 이에 본 연구는 기업의 불만처리 반응을 실질적인 보상, 종업원(직원)의 호의적인 행동 그리고 기업의 절차로 구분하였다. 이때 고객의 정의인식인 공정성 지각이 신뢰와 만족에 미치는 영향을 실증적으로 검증하여 실제적인 기업 반응의 중요성을 제시하고자 한다. 연구 대상은 기업에게 직접적으로 불만을 제기한 경험이 있는 210명의 설문 자료를 SPSS, AMOS를 이용하여 분석하였다. 연구 결과를 요약하면 불만고객에 대한 보상은 공정성에 유의한 영향을 미치는 것으로 나타났으며, 종업원의 호의적인 태도도 공정성에 유의한 영향을 미치는 것으로 나타났다. 불만에 대한 기업의 절차 역시 공정성에 유의한 영향을 미치는 것으로 본 연구에서는 분석되었다. 특히, 이러한 공정성은 정의 인식으로 고객의 미래 행동인 신뢰와 만족에 영향을 미치는 것으로 나타났다. 이런 연구 결과에 근거하여 시사점을 제시하고 미래 연구를 제안하였다.

Experimental Examination of Multivariable PID Controller Design on Frequency Domain using Liquid Level Process

  • Eguchi, Kazuki;Iwai, Zenta;Mizumoto, Ikuro;Kumon, Makoto
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.786-791
    • /
    • 2005
  • This paper is concerned with the examination and evaluation concerning a tuning method of multivariable PID controllers based on partial model matching on frequency domain proposed by authors from practical view point. In this case, PID controller parameters are determined by minimizing the loss function defined by the difference between frequency response of ideal model transfer function and actual frequency response on several frequency points. The purpose of the paper is to examine and evaluate the performance of the method through actual experiments of MIMO liquid level experimental process control equipment.

  • PDF

간접접촉 심전도 측정용 전극의 주파수 특성 (Frequency Response of the electrode for Indirect-contact ECG)

  • 임용규
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권3호
    • /
    • pp.249-253
    • /
    • 2008
  • The indirect-contact ECG (IDC-ECG) was introduced by a prior study for daily non-intrusive measurements. To improve the signal quality and to extend the application area of IDC-ECG, close study of the frequency characteristics of the IDC-ECG is necessary. In this study, the frequency response of the active electrode for several sample clothes was measured under conditions of actual IDC-ECG measurement with human body. Higher gain in low frequency range than expected by prior study was observed. In addition to it, wide variation in gain according to the cloth type in the low frequency range was observed. Variation in gain caused by moisture variation in the clothes was also observed. This study shows that the parallel R-C connection is proper for electrode model and the resistive factor is influenced by moisture in the clothes. This study is the first that provides the frequency response of the electrode in the actual indirect-contact ECG measurement and it is expected that the results will be helpful to improve the indirect-contact ECG method.