• 제목/요약/키워드: actual condition of using

검색결과 1,079건 처리시간 0.028초

해군함정 GPS의 오차시험과 이용 실태에 관한 연구 (A Study on the Error Test and Actual Using Condition of GPS in the Naval Vessels)

  • 임봉택;고광섭
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2005년도 춘계종합학술대회
    • /
    • pp.1125-1129
    • /
    • 2005
  • 본 연구에서는 GPS의 항법 차원에서의 제한사항 및 문제점들을 해군 실무를 기준으로 도출하고, 장래 GPS의 발전에 따른 항법 발전 방안에 대하여 논의해 보고자 한다. 이를 위해, 해군 함정에 설치된 GPS의 정밀도를 분석 및 확인해 보기 위하여 오차시험을 실시하였고, 사용자가 갖는 GPS에 대한 신뢰도와 그 활용도를 알아보기 위하여 함정근무 장교 및 부사관을 대상으로 한 면담 및 설문 조사를 실시하였다.

  • PDF

히트펌프식 냉난방장치의 철도차량 적용에 관한 연구 (A study on the application Heat Pump to Rolling Stock Air conditioner)

  • 권태균;송영정;정광무
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.1689-1696
    • /
    • 2008
  • Heat pumps transfer heat by circulating a substance called a refrigerant through a cycle of evaporation and condensation. But Heat pumps system by only using heat-source is not efficient. Because the mean temperature of North Korean winter season is low, economy of air heat-source heat pump descend. This paper is practiced the simulation on evaluation criteria for Heat pump heating and cooling systems to Rolling Stock. Efficiency of the heat pump in order improving from certainly the development of the technique will be able to prevent a freezing actual condition must proceed. As a result, Below $-10^{\circ}C$ used heating and cooling systems of heat pump format even in cold winter season and is serviceable confirmed with heat source supply circle of the Rolling Stock.

  • PDF

하우스 캐디유니폼의 치수만족도 및 착용 실태 조사 연구 (A survey on the size satisfaction and wearing conditions of house caddie uniforms)

  • 박우미
    • 한국의상디자인학회지
    • /
    • 제21권2호
    • /
    • pp.15-25
    • /
    • 2019
  • This study was carried out to research the size satisfaction and the actual conditions of house caddie uniforms. Survey participants consisted of 310 caddies at 6 membership golf clubs. In order to perform this study 45 questionnaires were used, which consisted of questions pertaining to size satisfaction and sewing, laundry management, and inconvenience and, most importantly performance. Frequency analysis was implemented using SPSS 10.0. The results of this study could be summarized as followed; The highest dissatisfaction factors in the presently worn uniforms were sleeve length and pants hem width. The highest dissatisfaction factors in the sewing satisfaction were pocket and armpit area. Activity is the most important consideration in the choice of a uniform. These results will be applied to develop a comfortable uniform design.

재활치료와 기능성게임 (Rehabilitation and Serious Games)

  • 김황용
    • 디지털융복합연구
    • /
    • 제12권4호
    • /
    • pp.69-73
    • /
    • 2014
  • 게임은 재미를 추구하지만 게임을 통해 다양한 긍정적 효과도 얻을 수 있다. 이러한 게임의 긍정적 효과를 이용하여 특정 목적을 달성하는 게임이 기능성게임이다. 본 논문에서는 기능성게임과 재활치료에 대하여 알아본다. 또한, 의료용 기능성게임의 유형과 재활치료용 기능성게임의 개발 실태를 알아보고, 재활치료용 기능성게임의 이용 활성화 방안을 제시한다.

Distortion Control of the Curved Panel Using Elastic Bending Method

  • Kim H. G.;Shin S. B.;Youn J. G.
    • International Journal of Korean Welding Society
    • /
    • 제5권1호
    • /
    • pp.29-34
    • /
    • 2005
  • Finite element analysis (FEA) and experimental studies on an elastic bending method have been performed in order to control the angular distortion at the fillet weldment for curved panel. Process parameters for the elastic bending method such as clamping span and release time were analyzed with reference to welding condition and geometric effect of the curved panel, which can minimize or prevent the angular distortion by producing a proper skin stress to the fillet weldment. The amounts of the angular distortion decrease almost in a linear manner with an increase in the skin stress. The skin stress required for non-angular distortion at the fillet weldment is strongly dependent on the plate thickness, not the heat intensity applied. The clamping span for obtaining uniform skin stress was defined as functions of the plate thickness and length of the free edge. Clamp should be removed after the fillet weldment is cooled down to room temperature for non-angular distortion. Effectiveness of the elastic bending method established was verified by its application to an actual curved panel.

  • PDF

肢體障碍人 便宜施設 設置에 관한 實態 分析- 영주시 공공건축물을 중심으로 - (The Analysis on the Actual Condition of Convenient Facilities for the Handicapped)

  • 황용운;금요찬
    • 한국주거학회논문집
    • /
    • 제13권6호
    • /
    • pp.141-150
    • /
    • 2002
  • The disabled peoples increase in number by disasters from the industrialization and urbanization. The physically handicapped people experience many difficulties in using the facilities in the public buildings. So, this survey proposed the necessary conditions for the handicapped peoples to use without any trouble in public buildings. The objects of investigation were public buildings, village offices, a public library, synthesis hospitals banks, an express bus station, a wedding building, a railroad station etc.. Conclusions were as follow \circled1 The most of buildings were established access road in regulations but parking area was established inappropriately in regulations \circled2 The most of convenience facilities were concentrated on first floor but were established barely in more than second floor. \circled3 The most of convenient facilities were established in appropriately in regulations. \circled4 The other convenient facilities(reception desk, ticket agency, work desk etc.) were not established nearly in the buildings of investigation.

지역별 지중 배전계통 공급방식의 공급신뢰도 평가 기법 (A Study on the Reliability Evaluation in Regional Underground Distribution System)

  • 최상봉;정성환;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.155-158
    • /
    • 2001
  • The objective of this study is to evaluate properly reliability of underground distribution system taking into account domestic circumstance. Interruption time and number of interruption customer by distribution system based on actual condition in domestic utility are considered as important index to estimate reliability of underground distribution system. This paper presents evaluation results regarding the reliability of an underground distribution system using a model system as new urban area, evaluation results which is established whether automatic system is introduced or not are shown in detail.

  • PDF

하이포이드 기어의 소음원인규명을 위한 디플렉션 테스트와 전달에러 측정에 대한 연구 (Identify Hypoid gear whine noise for Deflection test and Transmission error measurement)

  • 최병재;오재응;박상길
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1040-1047
    • /
    • 2008
  • Hypoid gears are widely used in rear drive and 4WD vehicle axles. Investigation of their sensitivity to deflections is one of the most important aspects of their design and optimization procedures. The deflection test is performed in the actual gear mounting using completely processed gear. This test should cover the full operating range of gear loads from no load to peak load. Under peak load the contact pattern should extend to the tooth boundaries without showing a concentration of the contact pattern at any point on the tooth surface. Transmission error is tested on an axle assembly triaxial real car load condition.

  • PDF

이중충격파형 충격시험장비를 이용한 충격시험 결과 및 분석 (The Shock-Test Result and Analysis Using Dual-Pulse Shock Testing Machine)

  • 배종수
    • 한국군사과학기술학회지
    • /
    • 제21권3호
    • /
    • pp.342-348
    • /
    • 2018
  • The important issue of equipment installed in maritime weapon system is shock survivability against underwater explosion(UNDEX). If the shock survivability of equipment should not be guaranteed, the successful mission also could not be achieved. For that reason, the shock-resistance of each equipment under UNDEX environment should be demonstrated before deployment at combat field. However, the actual UNDEX test on the ocean is too expensive to conduct. Also, it has diverse dangerous factors. The main characteristic of UNDEX is a dual-pulse shock. The vertical shock test machine able to simulate dual pulse shock signal on the ground will be introduced in this paper. The dual-pulse shock signal presented in certain shock standard was achieved with this shock-test machine on the ground. The analytical procedure to set a test condition was verified by comparing simulation result with experiment result.

환기장치가 설치된 중학교 교실에서 탄산가스 농도변화 측정 및 모델링 ($CO_2$ Gas Concentration Measurement and Modeling at a Classroom with Ventilation System of Middle School in Pusan)

  • 강태욱
    • 한국태양에너지학회 논문집
    • /
    • 제26권1호
    • /
    • pp.65-71
    • /
    • 2006
  • This study describes to analyze variation of carbon dioxide gas concentration by experimental and theoretical method according to the using patterns of ventilation system in a model classroom. Concentration of $CO_2$ gas varied by the occupancy and the ventilation systems are operating or not. More than 850 CMH ventilation system can maintain $CO_2$ gas concentration lower than 1,000 ppm along the class time and can be adopted the government guideline. Theoretical modeling of the concentration was performed at well-mixed ideal condition. Delays of concentration decay were shown at each case compared to actual.