• 제목/요약/키워드: active inverter

검색결과 467건 처리시간 0.022초

DC Rail Side Series Switch and Parallel Capacitor Snubber-Assisted Edge Resonant Soft-Switching PWM DC-DC Converter with High-Frequency Transformer Link

  • Morimoto, Keiki;Fathy, Khairy;Ogiwara, Hiroyuki;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제7권3호
    • /
    • pp.181-190
    • /
    • 2007
  • This paper presents a novel circuit topology of a DC bus line series switch and parallel snubbing capacitor-assisted soft-switching PWM full-bridge inverter type DC-DC power converter with a high frequency planar transformer link, which is newly developed for high performance arc welding machines in industry. The proposed DC-DC power converter circuit is based upon a voltage source-fed H type full-bridge soft-switching PWM inverter with a high frequency transformer. This DC-DC power converter has a single power semiconductor switching device in series with an input DC low side rail and loss less snubbing capacitor in parallel with the inverter bridge legs. All the active power switches in the full-bridge arms and DC bus line can achieve ZCS turn-on and ZVS turn-off transition commutation. Consequently, the total switching power losses occurred at turn-off switching transition of these power semiconductor devices; IGBTs can be reduced even in higher switching frequency bands ranging from 20 kHz to 100 kHz. The switching frequency of this DC-DC power converter using IGBT power modules can be realized at 60 kHz. It is proved experimentally by power loss analysis that the more the switching frequency increases, the more the proposed DC-DC power converter can achieve a higher control response performance and size miniaturization. The practical and inherent effectiveness of the new DC-DC converter topology proposed here is actually confirmed for low voltage and large current DC-DC power supplies (32V, 300A) for TIG arc welding applications in industry.

전력품질 보상기와 부하모의장치의 연계시험 분석 (Performance Analysis of load simulator interconnected with Power Quality Compensator)

  • 배병열;조윤호;박용희;한병문
    • 전력전자학회논문지
    • /
    • 제12권1호
    • /
    • pp.89-97
    • /
    • 2007
  • 본 논문에서는 새로 개발된 전력품질 보상장치의 성능을 실험실에서 효과적으로 분석하기 위해 필요한 새로운 부하모의장치를 제안하였다. 제안하는 부하모의장치는 2대의 PWM 인버터가 직류 단을 공유한 구조로 선형과 비선형부하를 단일기기로 시험 가능하도록 설계되어 있다. 그리고 전력품질보상기의 하나인 능동전력필터와 연계시험을 수행하였다. 본 논문에서는 제안하는 부하모의장치와 능동전력필터의 연계 특성을 분석할 목적으로 PSCAD/EMTDC 소프트웨어를 이용하여 시뮬레이션 실시하였고 또한 실적용시 타당성을 검증할 목적으로 20kVA 용량의 부하모의장치와 10kVA용량의 능동전력필터를 제작하여 실험을 실시하였다. 시뮬레이션과 하드웨어 실험결과 제안하는 부하모의장치는 능동전력필터의 다양한 보상 능력 검증에 충분히 활용가능함을 알 수 있었다.

Power Control Strategies for Single-Phase Voltage-Controlled Inverters with an Enhanced PLL

  • Gao, Jiayuan;Zhao, Jinbin;He, Chaojie;Zhang, Shuaitao;Li, Fen
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.212-224
    • /
    • 2018
  • For maintaining a reliable and secure power system, this paper describes the design and implement of a single-phase grid-connected inverter with an enhanced phase-locked loop (PLL) and excellent power control performance. For designing the enhanced PLL and power regulator, a full-bridge voltage-controlled inverter (VCI) is investigated. When the grid frequency deviates from its reference values, the output frequency of the VCI is unstable with an oscillation of 2 doubling harmonics. The reason for this oscillation is analyzed mathematically. This oscillation leads to an injection of harmonics into the grid and even causes an output active power oscillation of the VCI. For eliminating the oscillation caused by a PLL, an oscillation compensation method is proposed. With the proposed method, the VCI maintains the original PLL control characteristics and improves the PLL robustness under grid frequency deviations. On the basis of the above analysis, a power regulator with the primary frequency and voltage modulation characteristics is analyzed and designed. Meanwhile, a small-signal model of the power loops is established to determine the control parameters. The VCI can accurately output target power and has primary frequency and voltage modulation characteristics that can provide active and reactive power compensation to the grid. Finally, simulation and experimental results are given to verify the idea.

농업용 전기차량의 전기식 동력인출장치용 전력변환시스템 (Power Conversion System for Electric Power Take-off of Agricultural Electric Vehicle)

  • 곽봉우;김종훈
    • 전기전자학회논문지
    • /
    • 제23권3호
    • /
    • pp.994-1002
    • /
    • 2019
  • 본 논문은 농업용 전기차량의 전기식 동력인출장치용 전력변환시스템에 대해 제안한다. 대부분의 전기식 동력인출장치(Electric Power Take-Off : e-PTO)는 상용전원 $220V_{AC}$를 사용한다. 농업용 전기차량의 낮은 배터리 전압을 사용하여 높은 출력 전압을 공급하기 위한 DC-DC 컨버터와 DC-AC 인버터로 구성된 2단 구조를 갖는 양방향 전력변환시스템이 적합하다. 제안하는 전력변환시스템은 1단의 Dual Active Bridge(DAB)컨버터와 2단의 양방향 풀 브릿지 인버터로 구성된다. 또한, 초기 구동시 DC 버스단 커패시터 충전에 의해 발생되는 돌입 전류 저감을 위해 소프트 스타트 알고리즘을 제안한다. 3kW급 전력변환시스템 시제품 및 알고리즘을 구현하고 실험을 통해서 실용성을 입증하였다.

태양광발전 저압연계시 인버터 출력단 전압상승에 대한 연구 (A study on the voltage rise of the inverter output terminal according to the low voltage Grid connection of solar power generation)

  • 조강연;어익수
    • 한국산학기술학회논문지
    • /
    • 제21권11호
    • /
    • pp.746-752
    • /
    • 2020
  • 환경문제가 세계적으로 심각하게 다뤄지면서 우리나라도 태양광발전 설비가 급속도로 증가하였다. 특히 소용량 태양광발전을 저압배전으로 연계하는 계통에서 인버터 출력단의 전압상승으로 인하여 저압배전계통 품질저하 및 부하설비에 악영향을 주고 있다. 또한 과전압에 의한 인버터 가동중지로 인하여 발전소의 경제적 손실을 줄 수 있다. 본 논문에서는 저압배전계통 연계에 따른 태양광 인버터 출력단 전압 상승 해결방안을 연구 하였다. 첫째, 역률제어 및 능동전압제어 인버터를 사용하여 무효전력을 제어하면 출력단 전압이 230.91V에서 208.99V로 단자전압 비율이 약 10%가 내려갔다. 둘째, 배전전압용 변압기 2차 Tap을 조정하면 약 15V의 전압조정이 가능하지만, 한전배전규정전압이 220±13V의 범위가 벗어나지 않는 한 Tap을 조정해 주지 않는 문제점이 있다. 셋째, 인버터의 댓 수를 제한하면 인버터 과전압 범위 안에서 인버터를 기동할 수 있다. 넷째, 단상이 아닌 삼상으로 연계하면 전압이 분배되어 전압상승을 방지 할 수 있다. 4가지 중 현장 적용이 용이한 것은 역률제어 및 능동전압제어 인버터를 사용하는 것임을 확인하였다.

New Control Method for Power Decoupling of Electrolytic Capacitor-less Photovoltaic Micro-Inverter with Primary Side Regulation

  • Irfan, Mohammad Sameer;Shin, Jong-Hyun;Park, Joung-Hu
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.677-687
    • /
    • 2018
  • This paper presents a novel power decoupling control scheme with the bidirectional buck-boost converter for primary-side regulation photovoltaic (PV) micro-inverter. With the proposed power decoupling control scheme, small-capacitance film capacitors are used to overcome the life-span and reliability limitations of the large-capacitance electrolytic capacitors. Then, an improved flyback PV inverter is employed in continuous conduction mode with primary-side regulation for the PV power conditioning. The proposed power-decoupling controller shares the reference for primary side current regulation of the flyback PV inverter. The decoupling controller shapes the input current of the bidirectional buck-boost converter. The shared reference eliminates the phase-delay between the input current to the bidirectional buck-boost converter and the double frequency current at the PV primary current. The elimination of the phase-delay in dynamic response enhances the ripple rejection capability of the power decoupling buck-boost converter even with small film capacitor. With proposed power decoupling control scheme, the additional advantage of the primary-side regulation of flyback PV inverter is that there is no need to have an extra current sensor for obtaining the ripplecurrent reference of the decoupling current-controller of the power-decoupling buck-boost converter. Therefore, the proposed power decoupling control scheme is cost-effective as well as the size benefit. A new transient analysis is carried out which includes the source voltage dynamics instead of considering the source voltage as a pure voltage source. For verification of the proposed control scheme, simulation and experimental results are presented.

직류급전시스템의 회생 전력 활용을 위한 인버터 시험설비 개발 및 성능시험 (Development and Test of Inverter for Regenerative Power of DC Traction Power Supply System)

  • 김주락;한문섭;김용기;김정훈
    • 한국철도학회논문집
    • /
    • 제12권2호
    • /
    • pp.254-259
    • /
    • 2009
  • 국내 도시철도시스템에서 채용한 직류급전시스템에서 다이오드 정류시스템을 사용하여 역방향 조류가 불가능하다. 이에 따라 전동차의 감속 또는 제동시에 발생하는 회생 전력을 재활용하지 못하고 열에너지로 소비하게 된다. 잉여 회생 전력의 재활용은 에너지 이용의 극대화, 전동차의 제동 성능 향상 및 분진 감소 등의 환경 친화적인 효과를 얻을 수 있으며, 정류기와 역병렬로 인버터를 설치하여 타 계통으로 전달하거나 저장하는 형태로 가능하다. 본 논문에서는 발생한 잉여 회생 전력을 교류 전력으로 변환하여 고압배전계통이나 한전 계통으로 역송전이 기능한 회생용 인버터의 시험 설비 개발 및 성능시험에 대하여 제안하였다. 회생용 인버터 개발 후 개발품의 성능 시험을 위하여 직류급전시스템을 모의할 수 있는 교/직류 전원 설비 및 부하설비를 이용하여 회생용 인버터의 고유 성능을 시험 및 분석하였다.

복공진 인버터를 적용한 고역률 메탈핼라이드 램프용 전자식 안정기에 관한 연구 (A Study on High Power Factor Electronic Ballast for Metal Halide Discharge Lamp Using a Double Resonant Inverter)

  • 박재욱;서철식;남승식;김해준;원재선;김동희
    • 전력전자학회논문지
    • /
    • 제10권4호
    • /
    • pp.313-322
    • /
    • 2005
  • 본 논문은 복공진 인버터를 적용한 250[W] 메탈핼라이드램프를 구동하기 위한 고역률 전자식 안정기를 설계하고 구현하였다. 제안된 전자식 안정기는 역률 개선 회로기능을 갖는 부스트 능동 PFC 회로와 하프 브리지 복공진형 인버터로 구분된 2개의 전력처리단으로 구성되어 있다. 회로 기본동작원리 및 회로 해석은 무차원화 파라미터를 도입하여 범용성을 부여하여 도식적으로 나타내었다. 음향공명을 제거하기 위해 타이머 IC와 구동 IC로 구성된 간단한 주파수 제어기를 구현하였다. 실험을 통해 복공진 인버터를 적용한 고역률 메탈핼라이드램프용 전자식 안정기가 안정적으로 동작함을 확인하였다

A Smooth LVRT Control Strategy for Single-Phase Two-Stage Grid-Connected PV Inverters

  • Xiao, Furong;Dong, Lei;Khahro, Shahnawaz Farhan;Huang, Xiaojiang;Liao, Xiaozhong
    • Journal of Power Electronics
    • /
    • 제15권3호
    • /
    • pp.806-818
    • /
    • 2015
  • Based on the inherent relationship between dc-bus voltage and grid feeding active power, two dc-bus voltage regulators with different references are adopted for a grid-connected PV inverter operating in both normal grid voltage mode and low grid voltage mode. In the proposed scheme, an additional dc-bus voltage regulator paralleled with maximum power point tracking controller is used to guarantee the reliability of the low voltage ride-through (LVRT) of the inverter. Unlike conventional LVRT strategies, the proposed strategy does not require detecting grid voltage sag fault in terms of realizing LVRT. Moreover, the developed method does not have switching operations. The proposed technique can also enhance the stability of a power system in case of varying environmental conditions during a low grid voltage period. The operation principle of the presented LVRT control strategy is presented in detail, together with the design guidelines for the key parameters. Finally, a 3 kW prototype is built to validate the feasibility of the proposed LVRT strategy.

Cost-Effective APF/UPS System with Seamless Mode Transfer

  • Lee, Woo-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.195-204
    • /
    • 2015
  • In this paper, the development of a cost-effective active power filter/uninterruptible power supply (APF/UPS) system with seamless mode transfer is described. The proposed scheme employs a pulse-width-modulation (PWM) voltage-source inverter and has two operational modes. First, when the source voltage is normal, the system operates as an APF, which compensates for the harmonics and power factor while boosting the DC-link voltage to be ready for the disturbance, without an additional DC charging circuit. A simple algorithm to detect the load current harmonics is also proposed. Second, when the source voltage is out of the normal range (owing to sag, swell, or outage), it operates a UPS, which controls the output voltage constantly by discharging the DC-link capacitor. Furthermore, a seamless transfer method for the single-phase inverter between the APF mode and the UPS mode is also proposed, in which an IGBT switch with diodes is used as a static bypass switch. Dissimilar to a conventional SCR switch, the IGBT switch can implement a seamless mode transfer. During the UPS operation, when the source voltage returns to the normal range, the system operates as an APF. The proposed system has good transient and steady-state response characteristics. The APF, charging circuit, and UPS systems are implemented in one inverter system. Finally, the validity of the proposed scheme is investigated with simulated and experimental results for a prototype APF/UPS system rated at 3 kVA.