• 제목/요약/키워드: active capacitor

검색결과 357건 처리시간 0.028초

싸이리스터 정류부하를 위한 새로운 저원가 복합형 전력필터 (A New Low Cost Hybrid Power Filter for Thyristor-Controlled Rectifier Load)

  • 한성룡;김수근;석원엽;조정구;송의호;전희종
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권1호
    • /
    • pp.24-29
    • /
    • 2004
  • A new low cost hybrid active filter for thyristor-controlled rectifier load is presented to overcome the high cost problem of the active or the other hybrid active filters. The proposed hybrid active filter which consists of tuned (5th and 7th harmonics) LC passive filters, power factor improvement(PFI) capacitor bank, and active filter compensates power factor as well as harmonic currents. Since most of harmonic currents are filtered by the passive filter and most of reactive power is compensated by the PFI capacitor bank, the power rating of active filter can be minimized, resulting in cost minimization of the proposed hybrid active filter. A 300kVA hybrid active filter system is implemented and tested using 1MVA thyristor rectifier load to verify the operation and performance.

비선형 부하를 위한 복합전력필터 (Hybrid Active Filter System for High Power Non-linear Loads)

  • 강민수;노윤성;김수곤;전희종
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.182-185
    • /
    • 2003
  • Proposed Hybrid System is composed of phase leading capacitor banks, LC passive filters and active power filter. The passive power filter in parallel connection eliminate the 5th and 7th harmonics. The Variable capacitor banks correct the most of power factor, and the active power filter takes charge of remainder,

  • PDF

부하전류 추정기법에 의한 단상능동전력필터 제어 (A Single-Phase Active Power Filter Control with Load Current Estimation Method)

  • 곽상신;이무영;최연호;임성운;권우현
    • 전력전자학회논문지
    • /
    • 제5권4호
    • /
    • pp.335-342
    • /
    • 2000
  • 단상 능동전력필터에 있어서 비선형 부하전류를 직접 검출하지 않고 능통전력필터의 직류측 커패시터 전압을 이용해 추정하여 제어하는 방법을 제안한다. 이는 부하전류와 능동전택필터의 직류측 커패시터 전압을 봉사에 검출하는 기존의 방식에 비해 부하전류 검출단을 제거할 수 있음으로써 설치가 간편할 뿐만 아니라 가격을 낮출 수 있으면서도 동일한 성능의 능동전력필터의 구현을 가능하게 한다. 또한 직류측 커패시터 전압제어를 위해 샘플-흘드와 비례제어빙식을 사용하므로 기존의 저역통괴필터와 PI 제어시 적분기로 인한 지연을 없앨 수 있어 빠르고 우수한 과도응답특성을 나타낸다. 전원전압과 보상전류, 스위치 상태에 따라 8개의 모드로 나누어 능동전력필터의 동작을 설명하였으며, 제안한 방법의 성능을 실험을 통해 확인하였다.

  • PDF

Development of Multi-Cell Active Switched- Capacitor and Switched-Inductor Z-Source Inverter Topologies

  • Ho, Anh-Vu;Chun, Tae-Won;Kim, Heung-Geun
    • Journal of Power Electronics
    • /
    • 제14권5호
    • /
    • pp.834-841
    • /
    • 2014
  • This paper proposes new active switched-capacitor and switched-inductor Z-source inverter (ASC/SL-ZSI) topologies, which can provide a higher boost ability with a small shoot-through time. The proposed ASC/SL-ZSIs inherit all of the advantages of the classical ZSI, and have a stronger voltage boost inversion ability when compared with the classical ZSI. Thus, the output ac voltage quality is significantly improved. In addition, more cells can be cascaded in the impedance network in order to obtain a very high boost ability. The proposed topologies can be applied to photovoltaic or fuel-cell generation systems with low-voltage renewal sources due to their wide range of obtainable voltages. Both simulations and the experimental results are carried out in order to verify performance of the proposed topologies.

능동클램프회로를 갖는 병렬공전 인버터 링크형 DC-DC 컨버터 (A Parallel Resonant inverter linked type DC-DC Converter with active-c1amp circuits)

  • 오경섭;남승식;김동희;김희대;선우영호
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.311-314
    • /
    • 2003
  • In this paper, proposed circuit proposes that Active-Clamp-Circuits basis of a current-fed inverter linked type high frequency resonant dc-dc converter of conventional. and the paper the most of characteristics of the reduced high voltage stress main switches with active clamp circuits and output current constant with the resonant part consists of L, C resonant tank circuit. Also, the capacitor (C$_1$, C$_2$) connected in switches are a common using by resonance capacitor and ZVS capacitor. and circuit analysis used state equation of each part modes. Also we conform a rightfulness theoretical analysis by comparing a parameters values and simulation values obtained from simulation using Power MOS-FET as switching devices.

  • PDF

능동 전력 디커플링을 위한 3권선 방식의 플라이백 인버터 설계 (Design of Three-port Flyback Inverter for Active Power Decoupling)

  • 김규동;김준구;이태원;정용채;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.486-487
    • /
    • 2012
  • In this paper, novel three-port active power decoupling (APD) method for applying 250[W] micro-inverter. This type using third port for active power decoupling stores the surplus energy and supplies sufficient energy to grid. Conventional decoupling circuit is applied in single phase grid connected micro-inverter especially single-stage configuration like flyback-type DC-AC inverter. In this passive power decoupling method, electrolytic capacitor with large capacitance is needed for decoupling from constant DC power and instantaneous AC power. However the decoupling capacitor is replaced with film capacitor by using APD, thus the overall system can achieve smaller size and long lifespan. Proposed three-port flyback inverter is verified by design and simulation.

  • PDF

추가적인 센서가 필요 없는 3상 PWM 인버터의 LCL 필터 능동댐핑 (Active Damping of LCL Filter for Three-phase PWM Inverter without Additional Hardware Sensors)

  • 안병웅;신희근;김학원;조관열;한병문
    • 전력전자학회논문지
    • /
    • 제18권1호
    • /
    • pp.10-17
    • /
    • 2013
  • In this paper, a new active damping method of LCL filter without capacitor voltage sensors is proposed for 3 phase PWM Inverter. Normally, L filter or LCL filter is used as an output filter of grid connected PWM inverter. An LCL filter has more excellent performance than L filter to reduce harmonic current, so the small inductance value can be used. However, the resonance problem in LCL filter is happen due to the zero impedance by the addition of LC branch. To solve the resonance problem, the various active damping method has been proposed so far. Generally, the virtual resistor active damping methods is required to additional hardware sensors for measurement of capacitor voltage and current. In this paper, the new active damping method is proposed without any capacitor voltage or current sensors. In the proposed method, the resonance component of the capacitor voltage of LCL filter can be observed by a simple MRAS(Model Reference Adaptive System) observer without additional hardware sensors, and this component is suppressed by feedforward compensation. The validity of the proposed method is proven by simulation and experiment on the 3-phase PWM inverter system.

단상 액티브 파워 필터를 위한 새로운 전류 보상 방법 (A New Current Compensation Estimation Method For Single Phase Active Power Filter)

  • 곽상신;이무영
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.819-822
    • /
    • 1998
  • A new active power filter (APF) circuit with a current compesation estimation method is proposed. The current compensation estimation method replaces a current sensor with an estimating circuit and therefore reduces the implementation cost In addition, a simple control scheme, based on the energy balance concept, is adopted to control the voltage of a DC capacitor. Therefore energy change in the DC capacitor can be compensanted in the next cycle. Since a sampling technique is used, a larger DC capacitor voltage ripple can be permissible and a relatively smaller DC capacitor can be used. The proposed method has advantages of the reduction of one current sensor, low implementation cost, and fast transient responses. The theoretical analysis and simulation results are given. The proposed control method is successfully verified by computer simulation.

  • PDF

ADSL 모뎀용 CMOS 시그마-델타 DAC 칩 개발 (Development of CMOS Sigma-Delta DAC Chip for Using ADSL Modem)

  • 방준호;김선홍
    • 전기학회논문지P
    • /
    • 제52권4호
    • /
    • pp.148-153
    • /
    • 2003
  • In this paper, the low voltage 3V Sigma-Delta Digital Analog Converter(DAC) is designed for using in the transmitter of ADSL analog front-end. We have developed the CMOS DAC according to ANSI T1.413-2(DMT) standard specifications of the chip. The designed 4th-order DAC is composed of three block which are 1-bit DAC, 1st-order Switched-Capacitor filter and analog active 2nd-order Resistor-Capacitor(RC) filter. The HSPICE simulation of the designed DAC showing 65db SNR, is connected with 1.1MHz continuous lowpass filter. And also, we have performed the circuits verification and layout verification(ERC, DRC, LVS) followed by fabrication using TSMC 2-poly 5-metal p-substrate CMOS $0.35{\mu}m$ processing parameter. Finally, the chip testing has been performed and presented in the results.

A simple method to optimize DC-bus capacitor in 3-phase shunt Active power filter system

  • Phan, Dang-Minh;Lee, Hong-Hee
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.367-368
    • /
    • 2015
  • This paper introduces a shunt active power filter with a small DC bus capacitor by adding additional low-pass filter (LPF). The DC link voltage fluctuation is impressively suppressed with a small value in spite of the low value of DC-link capacitor under the steady-state condition. Consequently, the cost and volume of power converter are significantly reduced thanks to the reduced value of DC-bus capacitor. On the other hand, an indirect control strategy is used to maintain grid-side current when non-linear loads are connected to the system. By using proportional-integral (PI) and modified repetitive controller (RC) in dq0 frame, the calculation time is greatly decreased by 6 times compared with the conventional RC, and the number of measurement devices is also minimized. As a result, the acquired total harmonic distortion (THD) is lower than 2% regardless of the load conditions. Simulation results are carried out in order to verify the effectiveness of the proposed control strategy.

  • PDF