Anti-islanding Detection Method for BESS Based on 3 Phase Inverter Using Negative-Sequence Current Injection (역상분 전류 주입을 적용한 3상 인버터 기반 BESS의 단독 운전 검출 방법)

  • Sin, Eun-Suk;Kim, Hyun-Jun;Han, Byung-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.9
    • /
    • pp.1315-1322
    • /
    • 2015
  • This paper proposes an active islanding detection method for the BESS (Battery Energy Storage System) with 3-phase inverter which is connected to the AC grid. The proposed method adopts the DDSRF (Decoupled Double Synchronous Reference Frame) PLL (Phase Locked-Loop) so that the independent control of positive-sequence and negative-sequence current is successfully carried out using the detected phase angle information. The islanding state can be detected by sensing the variation of negative-sequence voltage at the PCC (Point of Common Connection) due to the injection of 2-3% negative-sequence current from the BESS. The proposed method provides a secure and rapid detection under the variation of negative-sequence voltage due to the sag and swell. The feasibility of proposed method was verified by computer simulations with PSCAD/EMTDC and experimental analyses with 5kW hardware prototype for the benchmark circuit of islanding detection suggested by IEEE 1547 and UL1741. The proposed method would be applicable for the secure detection of islanding state in the grid-tied Microgrid.

AFDPF(Active Drift Frequency Positive Feedback) Method for Anti - Islanding of Grid - Connected PV Inverter (계통연계형 PV 인버터의 독립운전 방지를 위한 AFDPF기법)

  • Eum, J.H.;Ahn, H.J.;Jung, Y.G.;Lim, Y.C.
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.188-190
    • /
    • 2009
  • 본 연구에서는 독립운전 검출기법의 능동적 기법 중 AFDPF 기법을 IEEE Std 929-2000에 제시된 독립운전 시험 조건하에서 위상동기기법 영점검출방식(Zero Crossing PLL)을 적용하여 독립운전 시 chopping fraction에 따른 PCC(Point of Common Coupling)의 주파수 변동 특성을 PSIM을 통하여 분석하였다

  • PDF

Analysis and design DC-DC converter for solar cell array output control (태양전지 출력제어를 위한 DC-DC 컨버터의 해석 및 설계)

  • 고재석
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.665-669
    • /
    • 2000
  • Recently the problem of energy branch become worse increasingly. Therefore many researches about new energy source are processing in several places around are processing in several places around the world. Especially solar energy has many advantages like as purity and infinity. Photovoltaic(PV) system can be classified into two types : One is stand alone type and the other is utility interactive one. Utility interactive type PV system need some technology that Maximum peak power tracking(MPPT) and Anti-islanding and Active Power filter(APF). For APF operation dc-link voltage should be high to supply sufficient output current which needed for harmonic current compensation so usually DC-DC converter is used for boost. In this paper DC-DC converter for PV system and controller for dc-link voltage control are analyzed and designed.

  • PDF

Evaluation the Non-Detection Zone of Anti-Islanding Methods (단독운전검출기법의 불검출 영역에 대한 비교 고찰)

  • Lee K. O.;So J. H.;Jung Y. S.;Yu G. J.;Choi J. Y.;Jung S. G.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.494-497
    • /
    • 2004
  • 계통연계형 태양광발전 시스템의 확대보급에 따라 단독운전 검출기법의 검출 성능에 대한 검증의 필요성이 대두되고 있다. 본 논문에서는 단독운전 검출기법의 대표적인 능동적 검출기법인 무효전력 변동기법 (reactive power variation method)과 주파수 쉬프트기법(active frequency drift method)을 IEEE Std 929-2000에서 명시된 단독운전검출 시험 방법을 이용하여 단독운전검출기법의 성능 및 불검출 영역(non-detection zone)에 대하여 비교 분석하였다.

  • PDF

Design Method for Frequency Drift Anti-islanding Detection Method Based on Analysis of Non Detection Zone (불검출 영역 분석을 통한 주파수 이동 단독 운전 검출 기법의 설계 방법)

  • Kim, Byeong-Heon;Sul, Seung-Ki
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.9-10
    • /
    • 2012
  • AFD(Active Frequency Drift), SMS(Slip-Mode frequency Shift)를 비롯한 주파수 이동 단독 운전 검출 방법은 단독 운전 발생 후, 계통의 주파수를 정상 운전 범위 밖으로 이동시켜 OUF(Over/Under Frequency) 릴레이를 동작하게 만들어 단독 운전을 검출한다. 이 방법들의 불검출 영역은 알고리즘에 의한 전류 위상각 변화율과 부하 역률 각 변화율 사이의 관계, 그리고 단독 운전 후 정상 상태(steady state) 운전 주파수에 의해 결정된다. 본 논문에서는 불검출 영역에 영향을 미치는 부하 역률 각 변화율을 분석하고 그를 바탕으로, 설계한 Q(Quality)-factor보다 낮은 Q-factor를 갖는 부하 조건에서는 항상 단독 운전을 검출할 수 있는 설계 방법을 제시한다. 제안된 방법의 유효성은 모의실험 및 실험으로 검증되었다.

  • PDF

Evaluation the Non-Detection Zone of Anti-Islanding Methods (단독운전검출기법의 불검출 영역에 대한 비교 고찰)

  • Lee K.O;So J.H;Jung Y.S;Yu G.J;Choi J.Y;Jung S.G;Choy I.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1480-1482
    • /
    • 2004
  • 계통연계형 태양광발전 시스템의 확대보급에 따라 단독운전 검출기법의 검출 성능에 대한 검증의 필요성이 대두되고 있다. 본 논문에서는 단독운전검출기법의 대표적인 능동적 검출기법인 무효전력변동기법 (reactive power variation method)과 주파수 쉬프트기법(active frequency drift method)을 IEEE Std 929-2000에서 명시된 단독운전검출 시험방법을 이용하여 단독운전검출기법의 성능 및 불검출 영역(non-detection zone)에 대하여 비교 분석하였다.

  • PDF

Anti-islanding Detection of a AFD Method applied to Grid Connected Micro Inverter (계통연계형 소용량 태양광 인버터에 적용된 AFD 방식의 단독운전 검출기법)

  • Kwak, Raeho;Lee, June Hee;Lee, Kyo-Beum
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.524-525
    • /
    • 2015
  • 본 논문은 계통연계형 소용량 태양광 인버터에 적용된 AFD(Active Frequency Drift) 기반의 단독 운전 검출 기법을 제안한다. 태양광 시스템에 일반적인 인버터 토폴로지를 사용한 경우, 무효전력 주입을 이용하여 단독운전 검출이 가능하다. 하지만 무효전력의 제어가 불가능한 인버터를 사용한 경우에는 기존의 무효전력을 이용하는 단독운전 검출기법을 사용할 수 없다. 무효전력의 제어가 불가능한 인버터 토폴로지에 새로운 스위칭 기법을 적용하면 무효전력을 주입한 효과를 얻을 수 있고, 이를 통해 기존의 AFD 방식을 응용하여 단독운전 검출이 가능한 새로운 검출기법을 제안하였다. 제안하는 검출기법은 기존의 AFD 방식보다 인버터 출력전류의 THD (Total Harmonic Distortion)를 개선할 수 있는 장점이 있다. 제안하는 기법의 성능을 시뮬레이션을 통해 확인하였다.

  • PDF