• Title/Summary/Keyword: acryl

Search Result 385, Processing Time 0.025 seconds

Analysis of the Dose Distribution of Moving Organ using a Moving Phantom System (구동팬텀 시스템에 의한 움직이는 장기의 선량분포 분석)

  • Kim, Yon-Lae;Park, Byung-Moon;Bae, Yong-Ki;Kang, Min-Young;Lee, Gui-Won;Bang, Dong-Wan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.81-87
    • /
    • 2006
  • Purpose: Few researches have been peformed on the dose distribution of the moving organ for radiotherapy so far. In order to simulate the organ motion caused by respiratory function, multipurpose phantom and moving device was used and dosimetric measurements for dose distribution of the moving organs were conducted in this study. The purpose of our study was to evaluate how dose distributions are changed due to respiratory motion. Materials and Methods: A multipurpose phantom and a moving device were developed for the measurement of the dose distribution of the moving organ due to respiratory function. Acryl chosen design of the phantom was considered the most obvious choice for phantom material. For construction of the phantom, we used acryl and cork with density of $1.14g/cm^3,\;0.32g/cm^3$ respectively. Acryl and cork slab in the phantom were used to simulate the normal organ and lung respectively. The moving phantom system was composed of moving device, moving control system, and acryl and cork phantom. Gafchromic film and EDR2 film were used to measure dose ditrbutions. The moving device system may be driven by two directional step motors and able to perform 2 dimensional movements (x, z axis), but only 1 dimensional movement(z axis) was used for this study. Results: Larger penumbra was shown in the cork phantom than in the acryl phantom. The dose profile and isodose curve of Gafchromic EBT film were not uniform since the film has small optical density responding to the dose. As the organ motion was increased, the blurrings in penumbra, flatness, and symmetry were increased. Most of measurements of dose distrbutions, Gafchromic EBT film has poor flatness and symmetry than EDR2 film, but both penumbra distributions were more or less comparable. Conclusion: The Gafchromic EBT film is more useful as it does not need development and more radiation dose could be exposed than EDR2 film without losing film characteristics. But as response of the optical density of Gafchromic EBT film to dose is low, beam profiles have more fluctuation at Gafchromic EBT. If the multipurpose phantom and moving device are used for treatment Q.A, and its corrections are made, treatment quality should be improved for the moving organs.

  • PDF

Accuracy Evaluation of CyberKnife $Synchrony^{TM}$ Respiratory Tracking System Using Phantom (Phantom을 이용한 사이버나이프 $Synchrony^{TM}$ 호흡 추적장치의 정확성 평가)

  • Kim, Gha-Jung;Bae, Seok-Hwan;Lim, Chang-Seon;Kim, Chong-Yeal
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.3
    • /
    • pp.137-143
    • /
    • 2009
  • This study was conducted to evaluate the accuracy of CyberKnife $Synchrony^{TM}$ respiratory tracking system which was applied to Stereotactic Radiosurgery (SRS) for moving tumors in chest and abdomen with breathing motion. For accurate evaluation, gold fiducial marks were implanted into a moving phantom. The moving phantom was a cube imbedding an acryl ball as a target. The acryl ball was prescribed to 20 Gy at 70% of isodose curve in a virtual treatment and radiochromic films were inserted into the acryl ball for dose verification and tracking accuracy evaluation. The evaluation of position tracking consists of two parts: fiducial mark tracking in a stationary phantom and $Synchrony^{TM}$ respiratory tracking in a moving phantom. Each measurement was done in three directions and was repeated to 5 times. Range of position error was 0.1957 mm to 0.6520 mm in the stationary phantom and 0.4405 mm to 0.7665 mm in the moving phantom. Average position error was 0.3926 mm and 0.5673 mm in the stationary phantom and the moving phantom respectively. This study evaluates the accuracy of CyberKnife $Synchrony^{TM}$ Respiratory tracking system, and confirms the usefulness when it's used for Stereotactic Radiosurgery of body organs.

Verification of Stereotactic Target Point Achieved by Acquisition of MR Image in Actual Treatment Position of Radiosurgery (정위적 방사선 수술시 치료위치에서의 정위적 표적점 확인을 통한 자기공명영상 획득의 정확도 연구)

  • 윤형근;신교철;김영식
    • Progress in Medical Physics
    • /
    • v.9 no.2
    • /
    • pp.89-94
    • /
    • 1998
  • To make practical application of the MR image for stereotactic radiosurgery, the target point-achieved by acquisition of MR image in stereotactic radiosurgery planning system must agree with the actual isocenter of irradiation in real treatment. And the amount of distortion of the MR image must be known to make a correction for the agreement. A radish containing abundant water content was chosen as a homogeneous phantom for the purpose of verification of the agreement in this experiment. A dosimetric film was firmly attached to the small specially fabricated acryl plate and needle puncture was made through the film just into the acryl plate and a drop of oil was dropped into the hole of the film. The acryl plate with film was inserted into the radish and the dorp of oil represented the target point in MR image. After the image acquisition by stereotatic radiosurgery planning system, we achieved stereotactic coordinate of the target point represented by the oil drop. And we proceeded to actual irradiation to the target point according to the procedure of stereotactic radiosurgery. After the irradiation, the film in the radish was developed and processed and the degree of coincidence between the center of the radiation distribution and the target point represented by the hole in the film was measured. The discrepancy between two points was under 0.5 mm. so we could confirm good coincidence in homogeneous phantom such as radish. On the other hand, authors tried to use our home-made device for estimation of distortion of MR image.

  • PDF

Synthesis of Acrylic Nonionic Reactive Emulsifier with Aromatic Ring and the Properties of Water-based Acryl Pressure Sensitive Adhesive (방향족 고리를 가지는 아크릴계 비이온 반응성 유화제 합성 및 이를 이용한 수성 점착제 물성 연구)

  • Yeom, Do-Young;Kim, Dong Hwan;Hwang, Gaeun;Hwang, Do-Hoon;Jung, Yu Jin
    • Journal of Adhesion and Interface
    • /
    • v.22 no.2
    • /
    • pp.31-38
    • /
    • 2021
  • In this study, a nonionic reactive emulsifier with aromatic and acryl group was synthesized by using polyoxyethylene(10) dodecylphenyl ether with 3-butenoic acid. The synthesized nonionic reactive emulsifier was confirmed by 1H-NMR and FT-IR. In addition, the reactive emulsifier synthesized in the preparation of aqueous acrylic adhesives base emulsion was used and the properties of the solid content, conversion, particle size distribution, peel strength and high temperature holding force were compared to those of nonionic emulsifiers without aromatic group. The particle size was distributed from 370 nm to 698 nm, and the peel strength were measured in the range of 1.507~1.802 kgf. The high temperature holding force of prepared adhesives base emulsion were measured in the range of 0.50~2.00 mm. Especially, in the result of synthesized nonionic reactive emulsifier with aromatic group, it was confirmed that high temperature holding force results were the most excellent than the case of using other nonionic reactive emulsifiers, and it can be useful for water-based acryl pressure sensitive adhesive.

Synthesis and Application of Acrylated Disperse Dyes (Acryl기를 도입한 분산염료의 합성과 염색성)

  • 박종호;한지연;정재윤
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2003.04a
    • /
    • pp.411-412
    • /
    • 2003
  • 1990년 초 일본의 Shingosen이 출현 이후, 합성 섬유가 갖는 일련의 장점을 유지하면서 천연섬유의 특성을 모방한 폴리에스테르 극세섬유의 등장으로 고급화 및 차별화 된 폴리에스테르 섬유의 상품 추구가 가능하게 되었다. 근래에 와서 통상적인 방법으로 얻어지는 극세사(Micro fiber)는 약 1d이며, 현재에는 보통사와는 전혀 다른 고도의 유연성$\boxUl$ 촉감, 외관을 가지는 0.3d이하의 공업적 방사도 가능하게 되었다. (중략)

  • PDF

The Flame Retardent and Electric Properties of Silicone Rubber (실리콘 고무의 내화 및 전기특성)

  • Hong, Sung-Ryool;Lee, Sung-Ill;Kim, Gui-Yeul;Jang, Kyung-Uk;Lee, Won-Jae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05d
    • /
    • pp.69-71
    • /
    • 2003
  • Mechanical Properties, such as tensile strength, elongation, and tear strength, decreased according to increasing the load of ATH, volume resistivity, AC break down strength, and tracking resistance for HVI SC contained ATH treated by vinyl Silane were better than those for HVI SC were contained ATH treated by other surface treatment agent, such as stearic acid and acryl silane.

  • PDF

Noise Neduction in the Stone Cutting Factory by Using Transparent Acrylic Enclosures (투명아크릴 밀폐형 방음상자를 이용한 석재절단공장 소음저감)

  • 이성춘;박상규
    • Journal of KSNVE
    • /
    • v.7 no.1
    • /
    • pp.107-116
    • /
    • 1997
  • Friction between stone and saw of stone cutting machine generates the noise of 96-104 dB in the frequency range of 2kHz-8kHz, which may cause occupational hearing loss. By designing enclosures which are made of transparent acryl, PVC panel and absorption materials, about 15 dB noise reduction has been achieved in the stone cutting factory. It is demonstrated that this kind of enclosures can be effectively used to reduce the noise in the stone cutting factory.

  • PDF

Structural Properties of Polyaniline Blended with PNIPAM

  • Neupane, Kosh-Prasad;Ha, Jin-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.3
    • /
    • pp.209-213
    • /
    • 2003
  • Polyaniline (PANi) composite particles were synthesized by chemical oxidation polymerization of aniline in presence of poly-n-isopropyl acryl amide (PNIPAM). The PANi particles formed in the reaction medium deposited onto non-conducting PNIPAM template to produce PANi-coated composite particles. The formation of composite was confirmed by FT-IR spectroscopy, and UV-VIS spectroscopy, and their morphological structures were examined by scanning electron microscopy (SEM). From the experimental results, it was determined that PANi was successfully coated onto non-conducting PNIPAM.

  • PDF

Parameter Estimation of Tissue Structure Characteristics in Ultrasound Measurement (초음파를 이용한 조직구조 특성변수의 측정)

  • 곽철은;김종원
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.1
    • /
    • pp.41-44
    • /
    • 1986
  • The objective of tissue characterization is to provide quantitative information about the physical state of tissue interrogated by an ultrasound beam. In the computer simulation, it was found that the echoes were composed of the interferences of the ultrasonic waves reflected from both sides of the thin object, and could be separated by the spectral correlation method. Also, the phantom study demonstrates that thickness of the thin acryl layer beyond the resolution of common ultrasonic imaging systems can be measured- using this method.

  • PDF