• Title/Summary/Keyword: across-wind

Search Result 194, Processing Time 0.022 seconds

Design Optimization of the Support Frame of an Antenna Positioner Mounted on a Vehicle (차량 탑재형 안테나 포지셔너의 반사판 지지대 최적설계)

  • Jang, Taeho;Kim, Youngshik
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.5
    • /
    • pp.411-416
    • /
    • 2014
  • In this research we present design optimization methods for a vehicle-mounted satellite antenna positioner. Our initial antenna positioner was conservatively designed to satisfy a worst case scenario where wind blew across the positioner at the speed of 120 km/h. Investigating stresses and safety based on Finite Element Methods (FEM), we find reflector support frames can be optimized to significantly reduce the weight of the positioner system. Thus, we optimize the reflector support frame from the given initial design while considering weight, maximum stress, maximum allowable deflection, cross section, and thickness. As a result, Shape C and the thickness of 2 mm are determined for the cross section of the reflector support frame. Applying this result, the weight of the new antenna positioner is 57.343 kg, which is decreased by 10.74% compared to the initial conservative design.

A Study on the Characteristics of Pressure Distribution for Heat Exchanger Types of Domestic Gas Boiler (가정용 가스보일러 열교환기 유형에 따른 압력분포특성에 관한 연구)

  • 최경석;오율권;차경옥
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.4
    • /
    • pp.22-28
    • /
    • 2001
  • Heat transfer and pressure distribution for heat exchanger type of domestic gas boiler are different from shape, pitch, thickness of fin and array of pipe respectively. In order to measure the pressure distribution across the heat exchanger, a suction type wind tunnel was constructed and velocity distribution was measured for pilot tube(4 point) of rack type. The experiments were performed for 5 different air flow mass, rpm=3,6,9,12,15 and transverse axis of heat exchanger(x-length) is 5cm respectively. Results showed that above 9.5m/s, pressure distribution dispersion for wet type of heat exchanger is on the increase and above 5.5m/s, pressure distribution dispersion for dry type of heat exchanger is on the increase. Also, pressure distribution dispersion by comparing two different types heat exchanger, dry type of heat exchanger showed a higher augmentation than wet type of heat exchanger.

  • PDF

Design and testing of a low subsonic wind tunnel gust generator

  • Lancelot, Paul M.G.J.;Sodja, Jurij;Werter, Noud P.M.;Breuker, Roeland De
    • Advances in aircraft and spacecraft science
    • /
    • v.4 no.2
    • /
    • pp.125-144
    • /
    • 2017
  • This paper summarises the design of a gust generator and the comparison between high fidelity numerical results and experimental results. The gust generator has been designed for a low subsonic wind tunnel in order to perform gust response experiments on wings and assess load alleviation. Special attention has been given to the different design parameters that influence the shape of the gust velocity profile by means of CFD simulations. Design parameters include frequency of actuation, flow speed, maximum deflection, chord length and gust vane spacing. The numerical results are compared to experimental results obtained using a hot-wire anemometer and flow visualisation by means of a tuft and smoke. The first assessment of the performance of the gust generator showed proper operation of the gust generator across the entire range of interest.

Evaluation of INPUFF Model Using METREX Tracer Diffusion Experiment Data (METREX 확산실험 자료를 이용한 INPUFF모델의 평가)

  • 이종범;송은영;황윤성
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.6
    • /
    • pp.437-452
    • /
    • 2002
  • The Metropolitan Tracer Experiment (METREX) was performed over the Washington, D.C. area using two inert, non-deposition perfluorocarbon gases for over 1 year period (November 1983∼December 1984). Two perfluorocarbon gas tracers (PDCH, PMCH) were released simultaneously at intervals of every 36 hours for 6 hours, regardless of the meteorological conditions in metropolitan area. Samples were collected continuously for 8 hours at a central downtown and two adjacent suburban locations. Monthly air samples were collected at 93 sites across the whole region (at urban, suburban, and rural locations). The purpose of this study is to simulate INPUFF and ISCST model using METREX data, and to compare calculated and observed concentrations. In the case of INPUFF simulation, two meteorological input data were used. One is result data from wind field model which was calculated by diagnostic wind model (DWM), the other is meteorological data observed at single station. Here, three kinds of model calculation were performed during April and July 1984; they include (1) INPUFF model using DWM data (2) INPUFF model using single meteorological data (3) ISCST model. The monthly average concentration data were used for statistic analysis and to draw their horizontal distribution patterns. Eight-hour-averaged concentration was used to describe movement of puff during the episode period. The results showed that the concentrations calculated by puff model (INPUFF) were better than plume model (ISCST). In the case of puff model (INPUFF), a model run using wind field data produced better results than that derived by single meteorological data.

Experiment of a Liquid Damper Controlling Bi-directional Wind Responses of a Tall Building (초고층 건물의 양방향 풍응답 제어를 위한 액체댐퍼 실험)

  • Lee, Hye-Ri;Min, Kyung-Won
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.3
    • /
    • pp.287-295
    • /
    • 2010
  • This study deals with the design of a bi-directional damper using a tuned liquid damper(TLD) and a tuned liquid column damper(TLCD) for a SDOF building. Two dampers are usually needed to reduce wind-induced responses of tall buildings since they are along and across wind ones. The proposed damper has the advantage of controlling both responses with a single damper. The damper used in this study behaves as both a TLCD in a specific translational direction and a TLD in the other orthogonal direction. This paper presents experimental verification to confirm its control performance. First, shaking table test is carried out to investigate reducing responses by the damper. Control performance of the damper is expressed by the transfer function from shaking table accelerations to SDOF building ones. Testing results show that the damper reduced bi-directional responses of a SDOF building. Also, it reduced torsion responses.

Dynamic characteristics monitoring of a 421-m-tall skyscraper during Typhoon Muifa using smartphone

  • Kang Zhou;Sha Bao;Lun-Hai Zhi;Feng Hu;Kang Xu;Zhen-Ru Shu
    • Structural Engineering and Mechanics
    • /
    • v.87 no.5
    • /
    • pp.451-460
    • /
    • 2023
  • Recently, the use of smartphones for structural health monitoring in civil engineering has drawn increasing attention due to their rapid development and popularization. In this study, the structural responses and dynamic characteristics of a 421-m-tall skyscraper during the landfall of Typhoon Muifa are monitored using an iPhone 13. The measured building acceleration responses are first corrected by the resampling technique since the sampling rate of smartphone-based measurement is unstable. Then, based on the corrected building acceleration, the wind-induced responses (i.e., along-wind and across-wind responses) are investigated and the serviceability performance of the skyscraper is assessed. Next, the amplitude-dependency and time-varying structural dynamic characteristics of the monitored supertall building during Typhoon Muifa are investigated by employing the random decrement technique and Bayesian spectral density approach. Moreover, the estimated results during Muifa are further compared with those of previous studies on the monitored building to discuss its long-term time-varying structural dynamic characteristics. The paper aims to demonstrate the applicability and effectiveness of smartphones for structural health monitoring of high-rise buildings.

Probabilistic analysis of gust factors and turbulence intensities of measured tropical cyclones

  • Tianyou Tao;Zao Jin;Hao Wang
    • Wind and Structures
    • /
    • v.38 no.4
    • /
    • pp.309-323
    • /
    • 2024
  • The gust factor and turbulence intensity are two crucial parameters that characterize the properties of turbulence. In tropical cyclones (TCs), these parameters exhibit significant variability, yet there is a lack of established formulas to account for their probabilistic characteristics with consideration of their inherent connection. On this condition, a probabilistic analysis of gust factors and turbulence intensities of TCs is conducted based on fourteen sets of wind data collected at the Sutong Cable-stayed Bridge site. Initially, the turbulence intensities and gust factors of recorded data are computed, followed by an analysis of their probability densities across different ranges categorized by mean wind speed. The Gaussian, lognormal, and generalized extreme value (GEV) distributions are employed to fit the measured probability densities, with subsequent evaluation of their effectiveness. The Gumbel distribution, which is a specific instance of the GEV distribution, has been identified as an optimal choice for probabilistic characterizations of turbulence intensity and gust factor in TCs. The corresponding empirical models are then established through curve fitting. By utilizing the Gumbel distribution as a template, the nexus between the probability density functions of turbulence intensity and gust factor is built, leading to the development of a generalized probabilistic model that statistically describe turbulence intensity and gust factor in TCs. Finally, these empirical models are validated using measured data and compared with suggestions recommended by specifications.

LARGE-SCALE CURRENTS AND SEA-BOTTOM ELEVATION CHANGE DEVELOPED BY WINTER STORMS

  • Sato, Shinji
    • Proceedings of the Korean Society of Coastal and Ocean Engineers Conference
    • /
    • 1996.10a
    • /
    • pp.89-94
    • /
    • 1996
  • Severe storms are frequently generated in winter along coasts on the Japan Sea side, which are developed by strong northwestern wind caused by periodic passages of low-pressure systems across the sea. The winter storm generally persists for several days, generating strong winds and large waves from northwest. During the storm, strong alongshore currents are also observed in the offshore region, which may continue to flow over a couple of days. (omitted)

  • PDF

Characteristics of Aerodynamic Damping on Helical-Shaped Super Tall Building (나선형 형상의 초고층건물의 공력감쇠의 특성)

  • Kim, Wonsul;Yi, Jin-Hak;Tamura, Yukio
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.1
    • /
    • pp.9-17
    • /
    • 2017
  • Characteristics of aerodynamic damping ratios of a helical $180^{\circ}$ model which shows better aerodynamic behavior in both along-wind and across-wind responses on a super tall building was investigated by an aeroelastic model test. The aerodynamic damping ratio was evaluated from the wind-induced responses of the model by using Random Decrement (RD) technique. Further, various triggering levels in evaluation of aerodynamic damping ratios using RD technique were also examined. As a result, it was found that when at least 2000 segments were used for evaluating aerodynamic damping ratio for ensemble averaging, the aerodynamic damping ratio can be obtained more consistently with lower irregular fluctuations. This is good agreement with those of previous studies. Another notable observation was that for square and helical $180^{\circ}$ models, the aerodynamic damping ratios in along-wind direction showed similar linear trends with reduced wind speeds regarding of building shapes. On the other hand, for the helical $180^{\circ}$ model, the aerodynamic damping ratio in across-wind direction showed quite different trends with those of the square model. In addition, the aerodynamic damping ratios of the helical $180^{\circ}$ model showed very similar trends with respect to the change of wind direction, and showed gradually increasing trends having small fluctuations with reduced wind speeds. Another observation was that in definition of triggering levels in RD technique on aerodynamic damping ratios, it may be possible to adopt the triggering levels of "standard deviation" or "${\sqrt{2}}$ times of the standard deviation" of the response time history if RD functions have a large number of triggering points. Further, these triggering levels may result in similar values and distributions with reduced wind speeds and either may be acceptable.

Experimental study on wake-induced vibrations of two circular cylinders with two degrees of freedom

  • Du, Xiaoqing;Jiang, Benjian;Dai, Chin;Wang, Guoyan;Chen, Suren
    • Wind and Structures
    • /
    • v.26 no.2
    • /
    • pp.57-68
    • /
    • 2018
  • Wind tunnel tests are conducted to investigate wake-induced vibrations of two circular cylinders with a center-to-center spacing of 4 diameters and attack angle varying from $0^{\circ}$ to $20^{\circ}$ for Reynolds numbers between 18,000 and 168,800. Effects of structural damping, Reynolds number, attack angle and reduced velocity on dynamic responses are examined. Results show that wake-induced vortex vibrations of the downstream cylinder occur in a wider range of the reduced velocity and have higher amplitudes in comparison to the vortex-induced vibration of a single circular cylinder. Two types of wake-induced instability phenomena with distinct dynamic characteristics are observed, which may be due to different generation mechanisms. For small attack angles like $5^{\circ}$ and $10^{\circ}$, the instability of the downstream cylinder characterizes a one-degree-of-freedom (1-DOF) oscillation moving in the across-wind direction. For a large attack angle like $20^{\circ}$, the instability characterizes a two-degree-of-freedom (2-DOF) oscillation with elliptical trajectories. For an attack angle of $15^{\circ}$, the instability can transform from the 1-DOF pattern to the 2-DOF one with the increase of the Reynolds number. Furthermore, the two instabilities show different sensitivity to the structural damping. The 1-DOF instability can be either completely suppressed or reduced to an unsteady oscillation, while the 2-DOF one is relatively less sensitive to the damping level. Reynolds number has important effects on the wake-induced instabilities.