• 제목/요약/키워드: acoustical comparison

검색결과 255건 처리시간 0.024초

음향라디오시티법을 이용한 잔향수조 음장 해석과 실험검증 (Acoustic Field Analysis of Reverberant Water Tank using Acoustic Radiosity Method and Experimental Verification)

  • 김국현
    • 대한조선학회논문집
    • /
    • 제56권5호
    • /
    • pp.464-471
    • /
    • 2019
  • The acoustic power is a major acoustical characteristic of an underwater vehicle and could be measured in a reverberant water tank. In order to obtain accurate measurement results, the acoustic field formed by the sound source should be investigated quantitatively in the reverberant water tank. In this research, the acoustic field of a reverberant water tank containing an underwater sound source has been analyzed by using an acoustic radiosity method one of the numerical analysis methods suitable for the acoustic analysis of the highly diffused space. The source level of the underwater sound source and acoustical properties of the water tank input to the numerical analysis have been estimated by applying the reverberant tank plot method through a preliminary experiment result. The comparison of the numerical analysis result with that of the experiment has verified the accuracy of the acoustic radiosity method.

OS CFAR 프로세서에 대한 새로운 시스톨릭 어레이 구조 (A New Systolic Array Architecture for the OS CFAR Processor)

  • 송재필
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1991년도 학술발표회 논문집
    • /
    • pp.163-168
    • /
    • 1991
  • In this paper, we propose a new systolic architecture for the order statistics(OS) constant false alarm rate(CFAR) processor. In the proposed architecture, each processing element(PE) can compare two reference data cells with one test cell simultaneously in each clock cycle. So the utilization of each PE in this architecture is 100% whereas the utilization of each PE in the systolic architecture previously reported by Ritcey and Hwang is 50% because of one clock delay between two adjacent PE's active in computation. This can speed up the data processing rate by a factor of two. With this architecture, we can obtain the reduced number of communication links between adjacent PE's and reduction of the latency by half in comparison with the one proposed by Ritcey and Hwang.

  • PDF

다중경로 페이딩 채널에서의 변복조 성능비교 (Performance Comparison for MODEM in MUltipath Fading Channel)

  • 전동근;박형근;이연우
    • 한국음향학회지
    • /
    • 제17권4호
    • /
    • pp.28-34
    • /
    • 1998
  • 미래 개인 휴대통신에서는 고속의 데이터 서비스를 위하여 높은 대역폭 효율을 요 구하게 된다. 무선통신 서비스를 향상시키기 위하여 코딩기법, 변조기법, 다중화기법 등의 다양한 방법이 연구되고 있다. 이중에서 특히 변조기법은 시스템의 성능을 결정하는 중요한 요소가 된다. 본 논문에서는 PSK. OQPSK, π/4 DQPSK, MSK, GMSK의 다섯가지 변조기 법에대한 BER성능을 시뮬레이션하였다. 시뮬레이션을 위한 다중경로 페이딩채널로서 3가지 서로 다른 채널을 적용하였다. 이때 시뮬레이션을 위하여 1.544Mbps의 전송속도와 1.9GHz 의 반성주파수 환경을 고려하였다. 또한 fractional 선형 등화기를 적용하여 변조방식에 따른 성능향상 정도를 비교하였다. 채널 Ⅰ, Ⅱ, Ⅲ에 대해 각각 30dB, 20dB, 10dB 정도에서 error floor현상이 발생했으며 π/4 DQPSKS가 가장 낮은 BER 특성을 보인 반면 QPSK는 가장 높은 BER을 나타냈다. 등화기를 적용했을 때는 GMSK의 성능향상이 가장 크게 나타 났다.

  • PDF

스피커 시스템의 성능 평가용 소프트웨어 패키지의 개발 (A Software Package Development for Loudspeaker Performance Evaluation)

  • 최영하;명형국;성굉모
    • 한국음향학회지
    • /
    • 제15권1호
    • /
    • pp.81-86
    • /
    • 1996
  • 스피커 시스템의 음질을 객관적이면서도 정확하게 평가할 수 있는 방안을 제시한다. 무향실에서 측정한 주파수 특성에 근거하여 사람이 들었을 때의 여러 가지 느낌을 예측해 내는 방법을 제안하고, 이러한 절차를 통합적으로 처리할 수 있는 소프트웨어을 개발하였다. 개발된 소프트웨어를 세 종류의 오디오 스피커에 대하여 적용한 결과, 사람의 시청평가에 의한 결과와 매우 유사한 평가치를 나타내었다.

  • PDF

COMPARISON OF DIFFERENT PROCEDURES FOR TONALITY CALCULATIONS.

  • Weber, R.;Dreesen, T.
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1994년도 FIFTH WESTERN PACIFIC REGIONAL ACOUSTICS CONFERENCE SEOUL KOREA
    • /
    • pp.650-655
    • /
    • 1994
  • The persence of distinct tones in environmental noises leads to an increasing anaoyance especially if the tones are of long duration. Before 1992 in Germany the tonal content of noises had to be subjectively estimated by the acoustic consultants and up to six dB could be added to the measured Leq depending on the tonality content of the noise under consideration. In order to give an objective basis for tonality estimated a DIN norm proposal for tonality evaluations was introduced in 1992. This proposal is compared with two different procedures : the prominece-ratio calculation which was proposed by Bienvenue and Nobile /4/ and the proposal of Ares /5/. The output of the three models is contrasted with subjective tonality judgements. It turns out that the prominence ratio model yields the best agreement with the subjective tonality assessments od the sound set chosen.

  • PDF

잡음 환경하에서의 다 모델 기반인식기와 다 스타일 학습방법과의 성능비교 (Performance Comparison of Multiple-Model Speech Recognizer with Multi-Style Training Method Under Noisy Environments)

  • 윤장혁;정용주
    • The Journal of the Acoustical Society of Korea
    • /
    • 제29권2E호
    • /
    • pp.100-106
    • /
    • 2010
  • Multiple-model speech recognizer has been shown to be quite successful in noisy speech recognition. However, its performance has usually been tested using the general speech front-ends which do not incorporate any noise adaptive algorithms. For the accurate evaluation of the effectiveness of the multiple-model frame in noisy speech recognition, we used the state-of-the-art front-ends and compared its performance with the well-known multi-style training method. In addition, we improved the multiple-model speech recognizer by employing N-best reference HMMs for interpolation and using multiple SNR levels for training each of the reference HMM.

Dialog System Using Multimedia Techniques for the Elderly with Dementia

  • 김성일;정현열
    • 한국음향학회지
    • /
    • 제21권4호
    • /
    • pp.170-170
    • /
    • 2002
  • The goal of the present research is to improve a quality of life of the elderly with a dementia. In this paper, it is realized by developing the dialog system that is controlled by three kinds of modules such as speech recognition engine, graphical agent, or database classified by a nursing schedule. The system was evaluated in an actual environment of a nursing facility by introducing it to an older male patient with dementia. The comparison study between dialog system and professional caregivers was then carried out at nursing home for 5 days in each case. The evaluation results showed that the dialog system was more responsive in catering to needs of dementia patient than professional caregivers. Moreover, the proposed system led the patient to talk more than caregivers did.

관내 평면파를 이용한 유속 측정기술 (Measurement Method of Mean Flow Velocity Using the Plane Waves in the Pipe)

  • 정완섭;권휴상;박경암;백종승
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 2000년도 학술발표대회 논문집 제19권 2호
    • /
    • pp.243-246
    • /
    • 2000
  • This paper addresses a new technique of measuring the mean flow velocity not only over the cross sectional area but also along the pipe by exploiting the acoustic plane waves in the pipe. When fluid flows in the pipe and two plane waves propagate oppositely through the medium in it, the flow velocity causes a change of the wave number of the plane waves. The wave number of the positive going plane wave decreases but oppositely that of negative going one increases in comparison to no flow of the medium in the pipe. Theoretical backgrounds of this method are in details discussed and measurement results of the mean flow velocity are illustrated to reveal the feasibility and effectiveness of the suggested technique.

  • PDF

수중 음향 압전 트랜스듀서의 등가 회로 모델링 (Equivalent Circuit Modeling of Underwater Acoustic Piezoelectric Transducer)

  • 조치영;서희선;이정민
    • 한국음향학회지
    • /
    • 제15권4호
    • /
    • pp.77-82
    • /
    • 1996
  • 본 연구에서는 샌드위치형 압전 트랜스듀서의 등가 회로 모델을 규명하는 방법을 제시하였다. 공기중에서 실험적으로 측정한 트랜스듀서의 전기적 어드미턴스와 이론적으로 계산된 어드미턴스의 오차가 최소가 되도록 하는 비선형 최적화 문제를 풀어 등가 회로에 관련된 미지 상수를 규명하였다. 예제 트랜스듀서에 대해 제안된 방법을 적용하여 등가회로를 모델링하고, 수중에서의 송신 음압 감도(TVR) 및 수신 읍압 감도(RVS)을 예측하고 실험치와 비교하여 규명된 등가 회로 모델의 타당성을 검증하였다.

  • PDF

VIBRO-ACOUSTIC TROUBLESHOOTING SOLVES 5MW BOILERFEED PUMP TESTRING NOISE & VIBRATION PROBLEMS

  • Gielen, L.;Vandenbroeck, D.
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1994년도 FIFTH WESTERN PACIFIC REGIONAL ACOUSTICS CONFERENCE SEOUL KOREA
    • /
    • pp.836-841
    • /
    • 1994
  • This paper describes the global vibro-acoustic troubleshooting approach, used to identify and separate different sources of noise and vibrations on a boilerfeed pump testrig. The pump serves for rotor dynamic research of a EC-funded BRITE-Euram profect. This approach resulted in the identification of local structural flexibilities in the connections between the machinery and the base plate. The relative importance of the modes during normal operation is revealed by comparison with operational deformation shapes. The use of sound intensity mapping allowed to calculate the total sound power and to rank the equipment according to its sound power contribution. High acoustic levels were found and related to the fluid drive and to the piping system. Modification of the piping section resulted in a reduction of noise and vibration levels along the test loop and smooth operation in a wide suction pressure range.

  • PDF