• Title/Summary/Keyword: acoustic measurements

Search Result 460, Processing Time 0.034 seconds

Acoustic Viscosity Characteristics of Oils with High Molecular Weight VI Improver Additives (고분자량 점도지수향상제가 첨가된 오일의 음향점도 특성)

  • Kong, H.;Ossia, C.V.;Han, H.G.
    • Tribology and Lubricants
    • /
    • v.25 no.4
    • /
    • pp.236-242
    • /
    • 2009
  • Oil viscosity is one of the important parameters for machinery condition monitoring. Basically, it is expressed as kinematic viscosity measured by capillary flow and dynamic or absolute viscosity measured by rotary shear viscometry. Recently, acoustic wave techniques appear in the market, measuring viscosity as the product of dynamic viscosity and density. For Newtonian fluids, knowledge of density allows conversion from one viscosity parameter to the other at a specific shear rate and temperature. In this work, oil samples with different chain lengths of viscosity index (VI) improvers and concentrations were examined by different viscometric techniques. Results showed that acoustic viscosity measurements give misleading results for oil samples with high molecular weight VI improvers and at low temperatures ${\leq}40^{\circ}C$.

Urban soundscape mapping based on GIS (GIS를 이용한 도시 사운드스케이프 지도화)

  • Hong, Joo Young;Kim, Jea Hyeon;Jeon, Jin Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.952-954
    • /
    • 2014
  • Urban sound environments consists of various sound sources such as traffic noise, sounds of people and natural sounds affecting the perception of soundscape in a place. However, noise maps based on sound pressure levels could not distinguish different sound sources and limited to represent perception of acoustic environments. Accordingly, soundscape map based on perception of sounds is necessary to provide useful information for the description of the acoustic environment. Therefore, the aims of this study are to examine soundscape perception in different urban contexts including commercial, office, park and residential spaces and to suggest a method for soundscape maps using GIS techniques. Soundscape perceptions and physical characteristics of acoustic environments at various urban contexts were obtained from surveys and acoustic measurements, respectively. The results show that dominant factors affecting soundscape perceptions were different in urban contexts and spatial variations of urban soundscape are closely related to various urban contexts.

  • PDF

Acoustic impedance model of perforated elements with both grazing and bias flow (스치는 유동과 관통 유동의 영향을 고려한 천공 요소의 음향 임피던스 모델)

  • Lee, Seong-Hyun;Ih, Jeong-Guon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1372-1375
    • /
    • 2006
  • The simplified impedance model which can consider a combined flow condition was suggested. Although the strength and position of the shear layer cannot be obtained by a linear sum of two separate contributions when both flows occur together, it was simply assumed that the impedance under the combined flow follows from summing the separate flow impedance. To validate the simplified impedance model, acoustic properties of a concentric resonator was predicted and measured. The predicted transmission loss using the simplified model shows reasonable agreements with measurements. One can find that the simplified impedance model obtained by the superposition of the separate flow impedances can be adjusted to predict the acoustic properties of a concentric resonator.

  • PDF

Time Domain Acoustic Holography by Step-by-step Measurement (단계적 측정법에 의한 시간 영역 음향 홀로그래피)

  • 윤호성;남경욱;김양한
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.635-639
    • /
    • 2003
  • When we carry out acoustic holography, step-by-step measurement provides us larger aperture size with same number of microphones. But when we carry out step-by-step measurement, it is blown that sound signal must be stationary. However, when transfer function between input and output signal is time-invariant, we can apply step-by-step measurement to acoustic holography even if sound signal is transient We have to do only some Processing on signals from step-by-step measurements to make the signal data of each step compatiable with other steps. This paper accounts for that processing method.

  • PDF

Pressure Dependence of Acoustic Properties of Liquid Ethanol by using High-pressure Brillouin Spectroscopy

  • Ko, Jae-Hyeon;Jeong, Min-Seok;Lee, Byoung Wan;Kim, Jae Hyun;Ko, Young Ho;Kim, Kwang Joo;Kim, Tae Hyun;Kojima, Seiji;Ahart, Muhtar
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.5
    • /
    • pp.279-286
    • /
    • 2013
  • Brillouin spectroscopy has been widely used for the investigation of acoustic properties of condensed matters in the hypersonic region. A high-pressure Brillouin spectrometer was set up by combining a diamond anvil cell and a tandem multi-pass Fabry-Perot interferometer. It was successfully applied to liquid ethanol, and the pressure dependence of the sound velocity, the refractive index and other acoustic properties were derived based on the measurements. The detailed optical setup and experimental procedure are described.

A Study on the Room Acoustic Characteristics according to the Layout System of Speakers in the School Gymnasium (학교체육관에서 스피커 배치방식에 따른 실내음향특성에 관한 연구)

  • Lee, Ju-Yeob;Kim, Jong-Bin;Park, Hyeon-Ku;Choi, Hyung-Wook;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.462-467
    • /
    • 2000
  • The aim of this study is to provide fundamental data for acoustic design by analyzing the room acoustic characteristics according to the PA system used in the school gymnasium. The measurements were carried out accordance with the ISO 3382. The sources used in this study were four types; omni-directional, centralized, distribution, the combination of centralized and distribution sound source system. Omni-directional system is recommended by ISO for the acoustic test and the others are installed on the wall, column and ceiling in the school gymnasium for sound reinforcement.

  • PDF

A Study on Detection of Tool Wear by Cutting Signal Measurements in Multi-insert Face Milling (정면밀링시 절삭신호측정에 의한 공구마모 검출에 관한 연구)

  • 김성일
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.6 no.4
    • /
    • pp.124-129
    • /
    • 1997
  • The experimental investigation is mainly focused to detect tool wear by cutting signal measurements in multi-insert face milling SS 41 and STS 304. This research have investigated the effects on the insert number, which has relationship with mean-cutting force. AE(acoustic emission) signal, tool life and surface roughness in machining SS41 and STS 304. The cutting force and AE signal are monitored to analyse the cutting process, The surface roughness of the specimens machined by TiN coated tool with the various insert numbers measured at various cutting speeds, feed rates and depths of cut, The width of flank wear is also observed.

  • PDF

Radiated Sound from Compliant and Viscoelastic Plates in a Turbulent Boundary Layer (난류 경계층에서 컴플라이언트 코팅과 점탄성 벽면의 방사 소음에 관한 실험적 연구)

  • Lee Seungbae;Lee Chang-Jun;Kwon O-Sup;Jeon Woo-Pyung
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.779-782
    • /
    • 2002
  • We examine the problem in which porous/viscoelastic compliant thin plates are subject to pressure fluctuations under transitional or turbulent boundary layer. Measurements are presented of the frequency spectra of the near-field pressure and radiated sound by compliant surface. A porous plate consisting of 5mm thick, open-cell foam with fabric covering and a viscoelastic painted plate of 1mm thick over an acoustic board of 4m thick were placed over a rigid surface in an anechoic wind tunnel. Streamwise velocity and wall pressure measurements were shown to highly attenuate the convective wall pressure energy when the convective wavenumber ($k_{ch}$) was 3.0 or more. The sound source localization on the compliant walls is applied to the measurement of radiated sound by using an acoustic mirror system.

  • PDF

Realization of Acoustic Scattering Holography (산란 음향 홀로그래피의 구현 방법론)

  • 김양한
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.11
    • /
    • pp.1101-1106
    • /
    • 2004
  • There are many difficulties to get the scattered field generated by obstacle which has arbitrary shape or irregular surface impedance by using analytic solution or numerical methods. In this study, we propose a method of which makes acoustic scattering holography that can predict the far-field scattered field based on nearfield measurements. This method provides the scattered fields of each wave-number components of incident fields. We express the relationship of wave-number components between incident fields and scattered fields using scattering matrix which is transfer matrix of wave-number components. Lastly, we prove the relation between wave-number components of incident and scattered field by experiments. The errors which are caused by measurements and decomposition methods are also analyzed.

Measurements of Sub- and Super Harmonic Waves at the Interfaces of Fatigue-Cracked CT Specimen

  • Jeong, Hyun-Jo;Barnard, Dan
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.1
    • /
    • pp.1-10
    • /
    • 2011
  • Nonlinear harmonic waves generated at cracked interfaces are investigated both experimentally and theoretically. A compact tension specimen is fabricated and the amplitude of transmitted wave is analyzed as a function of position along the fatigued crack surface. In order to measure as many nonlinear harmonic components as possible a broadband Lithium Niobate ($LiNbO_3$) transducers are employed together with a calibration technique for making absolute amplitude measurements with fluid-coupled receiving transducers. Cracked interfaces are shown to generate high acoustic nonlinearities which are manifested as harmonies in the power spectrum of the received signal. The first subharmonic (f/2) and the second harmonic (2f) waves are found to be dominant nonlinear components for an incident toneburst signal of frequency f. To explain the observed nonlinear behavior a partially closed crack is modeled by planar half interfaces that can account for crack parameters such as crack opening displacement and crack surface conditions. The simulation results show reasonable agreements with the experimental results.