• 제목/요약/키워드: acid corrosion

검색결과 500건 처리시간 0.023초

CP-Ti 및 Ti-6Al-4V 합금의 전기화학적 특성에 미치는 제조공정의 영향 (Effect of Manufacturing Process on Electrochemical Properties of CP-Ti and Ti-6Al-4V Alloys)

  • 김기태;조현우;장현영;김영식
    • Corrosion Science and Technology
    • /
    • 제17권1호
    • /
    • pp.20-29
    • /
    • 2018
  • Ti and its alloys show the excellent corrosion resistance to chloride environments, but they show less corrosion resistance in HCl, $H_2SO_4$, NaOH, $H_3PO_4$, and especially HF environments at high temperature and concentration. In this study, we used the commercially pure titanium and Ti-6Al-4V alloy, and evaluated the effect of the manufacturing process on the electrochemical properties. We used commercial products of rolled and forged materials, and made additive manufactured materials by DMT (Directed Metal Tooling) method. We annealed each specimen at $760^{\circ}C$ for one hour and then air cooled. We performed anodic polarization test, AC impedance measurement, and Mott-Schottky plot to evaluate the electrochemical properties. Despite of the difference of its microstructure of CP-Ti and Ti-6Al-4V alloys by the manufacturing process, the anodic polarization behavior was similar in 20% sulfuric acid. However, the addition of 0.1% hydrofluoric acid degraded the electrochemical properties. Among three kinds of the manufacturing process, the electrochemical properties of additive manufactured CP-Ti, and Ti-6Al-4V alloys were the lowest. It is noted that the test materials showed a Warburg impedance in HF acid environments.

Anthocyanins Extracted from Grapes as Green Corrosion Inhibitors for Tin Metal in Citric Acid Solution

  • Mohamed, Mervate Mohamed;Alsaiari, Raiedhah;Al-Qadri, Fatima A.;Shedaiwa, Iman Mohammad;Alsaiari, Mabkhoot;Musa, Esraa Mohamed;Alkorbi, Faeza;Alkorbi, Ali S.
    • Corrosion Science and Technology
    • /
    • 제21권5호
    • /
    • pp.381-389
    • /
    • 2022
  • Cyclic Voltammetry and weight loss measurements were used to investigate corrosion prevention of tin in a 0.5M citric acid solution containing Anthocyanins extracted from grapes at various concentrations and temperatures. Results showed that the investigated chemicals, Anthocyanins extracted from grapes, performed well as tin corrosion inhibitors in 0.5M citric acid. Increasing the concentration of Anthocyanins increased their corrosion inhibition efficiencies. When the temperature dropped, their inhibition efficiencies, increased indicating that higher temperature tin dissolution predominated the adsorption of Anthocyanins at the surface of tin metal. When inhibitor concentrations were increased, their inhibition efficiencies were also increased. These results revealed that corrosion of tin metal was inhibited by a mixed type of adsorption on the metal surface. The adsorption isotherm of Langmuir governed the adsorption of Anthocyanins. Thermodynamic parameters such as the enthalpy of adsorption, the entropy of adsorption, and Gibbs free energy and kinetic parameters such as activation energy, enthalpy of activation, and entropy of activation were computed and discussed in this study.

Corrosion of Dental Au-Ag-Cu-Pd Alloys in 0.9 % Sodium Chloride Solution

  • Chiba, Atsushi;Kusayanagi, Yukiharu
    • Corrosion Science and Technology
    • /
    • 제4권1호
    • /
    • pp.19-22
    • /
    • 2005
  • Two Au-Ag-Cu-Pd dental casting alloys (Au:12% and 20%) used. The test solutions used 0.9 % NaCl solution (isotonic sodium chloride solution), 0.9 % NaCl solution containing 1 % lactic acid, and 0.9 % NaCl solution containing 1 % lactic acid and 0.1 mol $dm^{-3}$ $Na_2S$. The surface of two samples in three sample solutions was not natural discoloration during one year. The alloy containing 12 % gold was easily alloyed and the composition was uniform comparing with the alloy containing 20 % gold. The rest potentials have not a little effect after three months. The kinds of metals could not definitely from the oxidation and reduction waves of metal on the cyclic voltammograms. The dissolutions of gold and palladium were 12 % Au sample in the 0.9 % NaCl solution containing 1 % lactic acid and 0.1 mol $dm^{-3}$ $Na_{2}S$. The pH of solution had an affect on dissolution of copper, and sulfur ion had an affect on dissolution of silver. The copper dissolved amount from 20 % gold sample was about 26 times comparing with that of 12 % gold sample in the 0.9 % solution containing 1 % lactic acid. Corrosion products were silver chloride and copper chloride in NaCl solution, and silver sulfide and copper sulfide in NaCl solution containing $Na_{2}S$.

산성비 및 배연탈황설비 환경에서 Ni 첨가에 따른 저합금강의 내식성 비교연구 (Comparative Study of Ni effect on the Corrosion Behavior of Low Alloy Steels in FGD and Acid Rain Environments)

  • 한준희;;장영욱;김정구
    • 대한금속재료학회지
    • /
    • 제47권9호
    • /
    • pp.558-566
    • /
    • 2009
  • The alloying effect of a small amount of nickel on low alloy steel for application to flue gas desulfurization(FGD) systems was studied. The structural characteristics of the rust layer were investigated by scanning electron microscopy(SEM). The electrochemical properties were examined by means of potentiostatic polarization test, potentiodynamic polarization test, and electrochemical impedance spectroscopy(EIS) in a modified green death solution of 16.9 vol.% $H_2SO_4$+0.35 vol.% HCl at $60^{\circ}C$ and an acid rain solution of $6.25{\times}10^{-5}M\;H_2SO_4+5.5{\times}10^{-3}M\;NaCl$ at room temperature. It was found that as the amount of nickel increased, the corrosion rate increased in the modified green death solution, which seemed to result from micro-galvanic corrosion between NiS and alloy matrix. In acid rain solution, the corrosion rate decreased as the amount of nickel increased due to the repulsive force of $NiFe_2O_4$ rust against $Cl^-$ ions by electronegativity.

Al2O3 산화 피막의 내식성에 미치는 양극산화 전류밀도의 영향 (Effect of Anodizing Current Density on Anti-Corrosion Characteristics for Al2O3 Oxide Film)

  • 이승준;장석기;김성종
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2016년도 추계학술대회 논문집
    • /
    • pp.153-153
    • /
    • 2016
  • Aluminum alloys have poor corrosion resistance compared to the pure aluminum due to the additive elements. Thus, anodizing technology artificially generating thick oxide films are widely applied nowadays in order to improve corrosion resistance. Anodizing is one of the surface modification techniques, which is commercially applicable to a large surface at a low price. However, most studies up to now have focused on its commercialization with hardly any research on the assessment and improvement of the physical characteristics of the anodized films. Therefore, this study aims to select the optimum temperature of sulfuric electrolyte to perform excellent corrosion resistance in the harsh marine environment through electrochemical experiment in the sea water upon generating porous films by variating the temperatures of sulfuric electrolyte. To fabricate uniform porous film of 5083 aluminum alloy, we conducted electro-polishing under the 25 V at $5^{\circ}C$ condition for three minutes using mixed solution of ethanol (95 %) and perchloric (70 %) acid with volume ratio of 4:1. Afterward, the first step surface modification was performed using sulfuric acid as an electrolyte where the electrolyte concentration was maintained at 10 vol.% by using a jacketed beaker. For anode, 5083 aluminum alloy with thickness of 5 mm and size of $2cm{\times}2cm$ was used, while platinum electrode was used for cathode. The distance between the two was maintained at 3 cm. Afterward, the irregular oxide film that was created in the first step surface modification was removed. For the second step surface modification process (identical to the step 1), etching was performed using mixture of chromic acid (1.8 wt.%) and phosphoric acid (6 wt.%) at $60^{\circ}C$ temperature for 30 minutes. Anodic polarization test was performed at scan rate of 2 mV/s up to +3.0 V vs open circuit potential in natural seawater. Surface morphology was compared using 3D analysis microscope to observe the damage behavior. As a result, the case of surface modification presented a significantly lower corrosion current density than that without modification, indicating excellent corrosion resistance.

  • PDF

탈황설비용 탄소강 코팅조성물의 내산성에 관한 연구 (Study on the corrosion resistance of coating mixture to acid for the desulfurization system)

  • 김인기;유정근
    • 한국결정성장학회지
    • /
    • 제16권6호
    • /
    • pp.278-285
    • /
    • 2006
  • 발전소의 탈황설비에 적용하기 위한 B-H 코팅조성물을 탄소강에 코팅하여 $65^{\circ}C{\sim}80^{\circ}C$에서 경화시켰다. 이들 시편을 $100^{\circ}C$$120^{\circ}C$의 70 wt% $H_2SO_4$ 용액에 접촉시킨 후 코팅조성물의 조성, 비이커스 경도, SEM에 의한 미세구조 등을 분석하였다. 황산에 대한 내산성은 내산성 시험후 코팅 조성물의 $SO_3$양과 관련이 있었다. 경화온도가 높을수록, 경화시간이 짧을수록 내산성이 좋았으나 고온일 경우에는 균열이 더 많이 발생하여 내산성을 떨어뜨렸다 B-H 코팅 조성물의 고온 내산성을 향상시키기 위한 조건은 경화온도 $65^{\circ}C$이상, 경화시간 12시간 이상이었다.

박물관 실내 대기오염물질에 의한 금속 부식 영향 (The metal corrosion caused by museum indoor air pollutants)

  • 강대일
    • 보존과학회지
    • /
    • 제22권
    • /
    • pp.5-14
    • /
    • 2008
  • 본 연구에서는 박물관 내장재료, 유물포장시 사용되는 포장재료에서 나오는 실내대기오염물질로 챔버 테스트 및 오디 테스트를 실시하였다. 오디 테스트 결과 금속에 따라서 목재나 시멘트에 의해 부식되는 형태가 다르게 나타난다는 것을 알 수 있었으며, 금속의 부식에 가장 많은 영향을 미친 목질제품은 18T HS(E0)와 9mm합판(F0,E0)이었으며, 시멘트는 6개월이 지난 시멘트였다. 유해가스 챔버 테스트 결과 대부분의 시편에서 부식이 관찰되었으며, 특히 포름산, 아세트산, 아세트알데히드에서 철, 구리, 청동시편의 부식이 심각하게 진행되었다. 포장재의 폭로실험에서는 저습의 조건에서 표면적으로 큰 변화가 나타나지 않으나, 고습의 조건에서는 금속 시편이 변색되거나 부식되는 현상이 나타났다.

  • PDF

은의 표면 부식 및 변색을 방지하기 위해 설치된 Al 희생양극의 전기화학적 특성에 미치는 황산 농도의 영향 (Effect of concentration of H2SO4 on electrochemical properties of equipped Al sacrificial anode to prevent the corrosion and discolor of silver surface)

  • 신병현;정원섭
    • 한국표면공학회지
    • /
    • 제54권1호
    • /
    • pp.12-17
    • /
    • 2021
  • Among the various precious metals, silver is used in various fields because of its low price than other precious metals. However, the surface of silver remains after rain in the atmosphere containing sulfur ions and chlorine ions, causing silver corrosion and discoloration. Existing documents have developed a anode to prevent corrosion but that are concentrated on secondary batteries. This study tried to prevent corrosion and discoloration of silver by using an Al sacrificial anode. Sulfuric acid decreased the potential of silver and increased the current density at active polarization and OCP. The amount of corrosion of silver with the Al sacrificial anode was reduced from 0.5 % to 6.5%. When silver is used for decoration outside, corrosion and discoloration of silver can be suppressed by installing an Al anode.

다중벽 탄소나노튜브를 이용한 철근 부식 검출 센서 제작 연구 (A study on the Corrosion Detection Sensor using Multi-Wall Carbon Nanotube)

  • 박수빈;김성연;이수정;최문정;홍영준;권성준;유봉영;윤상화
    • 한국표면공학회지
    • /
    • 제54권4호
    • /
    • pp.194-199
    • /
    • 2021
  • In this study, rebar corrosion detection sensor was fabricated using multi-walled carbon nanotubes (MWCNTs). MWCNTs were pre-treated in the acid electrolytes to attach the carboxylic acid to the surface of MWCNTs. The fabricated sensor was attached on the surface of rebar and it detected the corrosion of steel using LCR meter with variation of capacitance. The surface morphology and electrical properties were characterized using scanning electron microscope (SEM) and electrical test equipment, respectively. To verify the corrosion detection characteristics, comparison experiment using plastic bar was performed. Moreover, mechanism of corrosion detection sensor was discussed.

산성안개 하의 구조용강에서 피로균열의 발생 및 정류특성 (Properties of Fatigue Crack Initiation and Arrest in Structural Steel Under Acid Fog)

  • 김민건;김진학;김명섭;지정근;구은회
    • 대한기계학회논문집A
    • /
    • 제26권2호
    • /
    • pp.374-379
    • /
    • 2002
  • Corrosion fatigue tests were carried out to clarify the influence of acid fog as environmental factor on the fatigue strength of SM55C using rotary bending fatigue tester. The fatigue strength of acid fog specimen extremely decreased about 80% compared to that of distilled water specimen. In acid fog environment, a number of cracks commenced at corrosion pit and coalesced with the adjacent cracks during they propagate, and they formed a single non-propagating circumferential crack under the endurance stress of N=5$\times$10$\^$7/ cycles. Also, the depth of the crack is smaller than that of normal fatigue crack, so the crack has a veil small aspect ratio. The reason of this peculiar crack growth characteristics is that the crack opening-closure behaviors are hindered by corrosion products on the surface crack faces, and hence it is thinkable that the strong corrosion action like anodic dissolution for crack growth in depth direction is weaker compared with surface, resulting from faint pumping action of crack during loading-shedding processes.