• Title/Summary/Keyword: acid corrosion

Search Result 500, Processing Time 0.028 seconds

Performance Evaluation of Antioxidizing Device for Protection of Car Body (자동차 차체 보호를 위한 산화방지 장치의 성능 평가)

  • Kim, Hae Sik;Yun, Yeong Jin;Ji, Jong Gi
    • Journal of the Korean Chemical Society
    • /
    • v.46 no.5
    • /
    • pp.444-456
    • /
    • 2002
  • To protect the occurrence of the oxidation of car body, we developed antioxidizing device made with sacrificial anode. Because car body is made of iron and iron-alloy and oxidation potential of Mg, Al and Zn is higher than that of iron, sacrificial anodes were made with Mg, Al and Zn. Accordingly, Mg, Al and Zn are better oxidizing than car body, iron and iron-alloy can be protected from oxidizing. We have made an antioxidizing device and evaluated their anti-corrosive effect for iron piece in the solution of hydrochloric, nitric and sulfuric acid using balance, SEM and XPS. When iron pieces were connected with antioxidizing device of car body, weight loss by oxidation was remarkably reduced and surface corrosion of iron piece was protected. It was shown that the surface of iron pieces which is not con-nected to the device was changed to iron(Ⅲ) oxide, Fe$_2$O$_3$. Therefore, if this device is attached to car body, corrosion and oxidation of car body will be reduced, considerably.

Spectroscopic and Electrochemical Study on the Citrate-based CuNi Codeposition (구연산 기반 구리-니켈 합금도금에 대한 분광학적/전기화학적 특성 연구)

  • Lee, Joo-Yul;Yim, Seong-Bong;Kim, Man;Jeong, Yong-Soo
    • Journal of the Korean institute of surface engineering
    • /
    • v.44 no.3
    • /
    • pp.117-123
    • /
    • 2011
  • We investigated the spectroscopic and electrochemical properties of the citrate-based CuNi solution at different solution pH and analyzed various surface properties of CuNi codeposition layer. By combining UV-Visible spectroscopic data with potentiodynamic polarization curves, it could be found that the complexation of $Ni^{2+}$-citrate pair was completed at lower solution pH than $Cu^{2+}$-citrate pair and was affected by the coexistent $Cu^{2+}$ ions, while the complexation between $Cu^{2+}$ ions and citrate was not sensitive to the presence of $Ni^{2+}$ ions. Also, the electron transfer from cathode to $Cu^{2+}$-citrate and$Ni^{2+}$-citrate was hindered by strong complexation between $Cu^{2+}/Ni^{2+}$ ions and citrate and so apparent codeposition current densities were reduced as the solution pH increases. CuNi codeposited layers had a higher Cu content when they were prepared at high pH solution due to the suppression of Ni deposition, and when codeposition was executed in an agitated condition due to the acceleration of mass transfer of $Cu^{2+}$ ions in the solution. Actually, solution pH had little effect on the surface morphology and deposits orientation, but greatly influenced the corrosion resistance in 3.5% NaCl solution by modifying the chemical composition of CuNi layers and so pH 3 was expected as the most suitable solution pH in the viewpoint of corrosion coatings.

Development of the vapor film thickness correlation in porous corrosion deposits on the cladding in PWR

  • Yuan Shen;Zhengang Duan;Chuan Lu ;Li Ji ;Caishan Jiao ;Hongguo Hou ;Nan Chao;Meng Zhang;Yu Zhou;Yang Gao
    • Nuclear Engineering and Technology
    • /
    • v.54 no.12
    • /
    • pp.4798-4808
    • /
    • 2022
  • The porous corrosion deposits (known as CRUD) adhered to the cladding have an important effect on the heat transfer from fuel rods to coolant in PWRs. The vapor film is the main constituent in the two-phase film boiling model. This paper presents a vapor film thickness correlation, associated with CRUD porosity, CRUD chimney density, CRUD particle size, CRUD thickness and heat flux. The dependences of the vapor film thickness on the various influential factors can be intuitively reflected from this vapor film thickness correlation. The temperature, pressure, and boric acid concentration distributions in CRUD can be well predicted using the two-phase film boiling model coupled with the vapor film thickness correlation. It suggests that the vapor thickness correlation can estimate the vapor film thickness more conveniently than the previously reported vapor thickness calculation methods.

The Effects of Pretreatment and Surfactants on CNT and Permalloy Composite Electroplating (전처리와 분산제가 CNT-permalloy 복합전기도금에 미치는 영향 연구)

  • Um, Ho-Kyung;Lee, Heung-Yeol;Yim, Tai-Hong;Lee, Jae-Ho
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.17 no.1
    • /
    • pp.63-68
    • /
    • 2010
  • CNT and permalloy composite plating was investigated. CNTs were pretreated prior to electroplating to disassemble the tangled CNT lumps. The ball milling as a physical pretreatment and the acid treatment as a chemical pretreatment were used. 10M nitric acid and 10 M sulfuric acid were used for the chemical pretreatment. Sulfuric acid was more effective than nitric acid to disassemble CNT lumps. To disperse CNT in the solution, surfactants were used. SDS, Triton X-100 and PAA were used for this purpose. More CNTs were incorporated in permalloy coating when PAA was used as a surfactant. The surface morphologies were observed with FESEM after electroplating CNT and permalloy. The current densities were varied from 10 to $80\;mA/cm^2$ and the concentration of PAA was fixed at 2 g/L. The optimum current density without surface cracks was $20\;mA/cm^2$. The crystallinity of the deposit was analyzed with XRD and the surface hardness was analyzed with Vicker's hardness tester. The corrosion behavior was analyzed with polarization plot. The physical properties of permalloy were not improved with CNT composite plating.

Development on Antibiotic Concrete Mixed with Antibacterial Metals and Metallic Salts (금속 및 금속염계 항균제가 혼입된 항균 콘크리트 개발)

  • Choi, Hong-Shik;Heo, Kwon;Lee, Ho-Beom;Lee, Si-Woo;Kwak, Hong-Shin
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.1 no.2
    • /
    • pp.136-143
    • /
    • 2013
  • In the sewage structures and wastewater facilities, concrete is exposed to hydrogen sulfide ($H_2S$) which acts as an acid material in a solution, and a strongly acidic sulfate ion ($SO{_4}^{-2}$) is generated by a sulfuric bacteria. Hence, a degradation of concrete with biochemical corrosion would be accelerated. Finally, durability of concrete and concrete structures may be greatly reduced. In this study, in order to remove the hydrogen sulfide which is used by the sulfuric bacteria organic-biologically, the antibiotic metal and metallic salt powders were mixed to concrete, and a suppressing performance of the sulfate ion was assessed. For the sulfuric acid bacteria, a comparative evaluation of antimicrobial performance on neutralized concrete specimens were carried out, also by a rapid chloride penetration test, chloride penetration depths and diffusion coefficients were measured for antibiotic concrete in accordance with the amount of metal and metallic salt-based antibacterial agents. Eventually, by an observation of the biochemical state of the surface of concrete specimens exposed outdoors, the performance and applicability of antibiotic concrete were confirmed.

Electricity Production by Metallic and Carbon Anodes Immersed in an Estuarine Sediment (퇴적토에 담지된 금속 및 탄소전극에 의한 전기 생산 특성)

  • Song, Hyung-Jin;Rhee, In-Hyoung;Kwon, Sung-Hyun;Cho, Dae-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.12
    • /
    • pp.3731-3739
    • /
    • 2009
  • One-chambered sediment cells with a variety of anodic electrodes were tested for generation of electricity. Material used for anodes was iron, brass, zinc/iron, copper and graphite felt which was used for a common cathode. The estuarine sediment served as supplier of oxidants or electron-producing microbial habitat which evoked electrons via fast metal corrosion reactions or a complicated microbial electron transfer mechanism, respectively. Maximum power density and current density were found to be $6.90\;W/m^2$ (iron/zinc) and $7.76\;A/m^2$ (iron), respectively. Interestingly, copper wrapped with carbon cloth produced better electric performance than copper only, by 60%, possibly because the cloth not only prevented rapid corrosion on the copper surface by some degrees, but also helped growing some electron-emitting microbes on its surface. At anodes oxidation reduction potential(ORP) was kept to be stationary over time except at the very initial period. The pH reduction in the copper and copper/carbon electrodes could be a sign of organic acid production due to a chemical change in the sediment. The simple estimation of interfacial, electrical resistances of electrodes and electrolyte in the sediment cell that a key to the electricity generation should be in how to control corrosion rate or microbial electron transfer activity.

Influence of shape and finishing on the corrosion of palladium-based dental alloys

  • Milheiro, Ana;Muris, Joris;Kleverlaan, Cornelis J.;Feilzer, Albert J.
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.1
    • /
    • pp.56-61
    • /
    • 2015
  • PURPOSE. The purpose of this study was to evaluate the effects of the surface treatment and shape of the dental alloy on the composition of the prosthetic work and its metallic ion release in a corrosive medium after casting. MATERIALS AND METHODS. Orion Argos (Pd-Ag) and Orion Vesta (Pd-Cu) were used to cast two crowns and two disks. One of each was polished while the other was not. Two as-received alloys were also studied making a total of 5 specimens per alloy type. The specimens were submersed for 7 days in a lactic acid/sodium chloride solution (ISO standard 10271) and evaluated for surface structure characterization using SEM/EDAX. The solutions were quantitatively analysed for the presence of metal ions using ICP-MS and the results were statistically analysed with one-way ANOVA and a Tukey post-hoc test. RESULTS. Palladium is released from all specimens studied (range $0.06-7.08{\mu}g{\cdot}cm^{-2}{\cdot}week^{-1}$), with the Pd-Cu alloy releasing the highest amounts. For both types of alloys, ion release of both disk and crown pairs were statistically different from the as-received alloy except for the Pd-Ag polished crown (P>.05). For both alloy type, disk-shaped pairs and unpolished specimens released the highest amounts of Pd ions (range $0.34-7.08{\mu}g{\cdot}cm^{-2}{\cdot}week^{-1}$). Interestingly, in solutions submerged with cast alloys trace amounts of unexpected elements were measured. CONCLUSION. Shape and surface treatment influence ion release from dental alloys; polishing is a determinant factor. The release rate of cast and polished Pd alloys is between $0.06-0.69{\mu}g{\cdot}cm^{-2}{\cdot}week^{-1}$, which is close to or exceeding the EU Nickel Directive 94/27/EC compensated for the molecular mass of Pd ($0.4{\mu}g{\cdot}cm^{-2}{\cdot}week^{-1}$). The composition of the alloy does not represent the element release, therefore we recommend manufacturers to report element release after ISO standard corrosion tests beside the original composition.

Acid Drainage and Damage Reduction Strategy in Construction Site: An Introduction (건설현장 산성배수의 발생현황 및 피해저감대책)

  • Kim, Jae-Gon
    • Economic and Environmental Geology
    • /
    • v.40 no.5
    • /
    • pp.651-660
    • /
    • 2007
  • Acid drainage has been recognized as an environmental concern in abandoned mine sites for long time. Recently, the environmental and structural damage by acid drainage is a current issue in construction sites in Korea. Here, the author introduces the type of damages by acid drainage in construction sites and emphasizes the importance of geoscience discipline in solving the problem. Metasedimentary rock of Okcheon group, coal bed of Pyeongan group, Mesozoic volcanic rock. and Tertiary sedimentary and volcanic rocks are the major rock types with a high potential for acid drainage upon excavation in Korea. The acid drainage causes the acidification and heavy metal contamination of soil, surface water and groundwater, the reduction of slope stability, the corrosion of slope structure, the damage on plant growth, the damage on landscape and the deterioration of concrete and asphalt pavement. The countermeasure for acid drainage is the treatment of acid drainage and the prevention of acid drainage. The treatment of acid drainage can be classified into active and passive treatments depending on the degree of natural process in the treatment. Removal of oxidants, reduction of oxidant generation and encapsulation of sulfide are employed for the prevention of acid drainage generation.

Failure Mode of the Positive Plate on Charging Voltage in Gel Type Valve Regulated Lead Acid Batteries (충전전압에 따른 겔형 VRLA전지 양극판의 파손방식)

  • Oh Sanghyub;Kim Myungsoo;Lee Heung Lark
    • Journal of the Korean Electrochemical Society
    • /
    • v.3 no.2
    • /
    • pp.90-95
    • /
    • 2000
  • Cycle life test was carried out to evaluate the failure modes of the gel type nth batteries at $C_5$ currents and $100\%$ DOD. When the batteries were charged at constant voltage of 2.40 V and 2.50 Vi respectively, cycle lift was over 1,000 cycles. The batteries lost 426.4 g and 391.2 g of electrolyte far each case after the weight measurement. The battery charged at 2.50 V was shown to have a better cyclic performance than charged at 2.40 V, and the amounts of electrolyte loss was proportional to charge factor. After cycle test, the micro-structure of positive active material was completely changed and the corrosion layer of positive grid was about $50{\mu}m$. Failure mode of the positive plate of the gel type battery was a shedding of the positive active material, and the cause of discharge capacity decrease was found to be a electrolyte loss.

A Study on the Properties of Epoxy Based Powder Coating with Various Curing Agents (에폭시 분체도료의 경화제 종류에 따른 물성에 관한 연구)

  • Park, Jae-Hong;Shin, Young-Jo
    • Applied Chemistry for Engineering
    • /
    • v.9 no.1
    • /
    • pp.58-65
    • /
    • 1998
  • Substituted dicyandiamide(Sub-DICY), Accelerated dicyandiamide(Acc-DICY), Trimellitic anhydride(TMA), Pyromellitic dianhydride(PMDA) and Phenolic curing agent(Ph.C.A.) are mainly used for epoxy powder coating curing agent. Various characteristics of epoxy films fully cured by optimum condition such as mechanical properties like $T_g$, tensile strength, elongation at break hardness, abrasion resistance and chemical properties like water absorption, acid resistance, alkali resistance and electrical properties, corrosion resistance are determined by various measuring devices and analyses devices. In conclusion, phenolic curing agent was shown excellent thoughness but severe color change as temperature increased. Acid anhydride has excellent insulation properties and color stability at elevated temperature but lower thoughness and adhesion to substrate. DICY curing agent was shown high water absorption and severe color chance as temperature increased.

  • PDF