• Title/Summary/Keyword: accuracy test

검색결과 4,894건 처리시간 0.029초

반도체 초정밀장비의 진동허용규제치를 고려한 지지구조의 동특성 개선에 관한 연구 (A Study on the Structural Dynamic Modification of Sub-structure of Clean Room Considering Vibration Criteria)

  • 손성완;이홍기;백재호
    • 반도체디스플레이기술학회지
    • /
    • 제2권2호
    • /
    • pp.25-30
    • /
    • 2003
  • In the case of a vibration sensitive equipment, it require a vibration free environment to provide its proper function. Especially, lithography and inspection device, which have sub-nanometer class high accuracy and resolution, have come to necessity for producing more improved Giga Class semi conductor wafers. This high technology equipments require very strict environmental vibration criteria in proportion to the accuracy of the manufacturing. In this paper, the dynamic analysis and modal test were performed to evaluate the dynamic properties of the constructing clean room structure. Based on these results, a structural dynamic modification(SDM) were required to satisfiy the vibration allowable limit for pression machine. Therefore, in order to improve the dynamic stiffness of clean room structure, the VSD system which can control the force applied on structure, were adopted and its utility were proved from dynamic test results of the improved structure after a modification work.

  • PDF

한국 연안의 DGPS망 구축을 위한 장기갑기준국으로부터의 DGPS 측정에 관한 연구 (A Study on DGPS Test Using Chaggi-gap Reference Station to Construct DGPS Network in Korea Coast)

  • 이형욱;홍성래;고광섭;임정빈;정세모
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 1998년도 춘계학술발표회 논문집
    • /
    • pp.36-47
    • /
    • 1998
  • The test transimissionof DGPS correction data has been carried out since early 1996. The data has been sent from marine radiobeacon station at Changgi Gap Ligthouse. It was the first test brosdcast of DGPS correction data based on midium frequency of marine radiobeacon where transmission power and rate are 300W and 100bps respectively. However, there has not been any scientific study on the characteristic of the accuracy of a marine DGPS/radiobeacon. Accordingly. this paper investigates the accuracy of the system, which is currently operating in 310KHz. As a result , planned 8 reference station and coverage verified that the differential positioning accuray using themarine radiobeacon is sufficient to ensure the safetyof marine activities around the coast of Korea(position error of distance 107NM at reference station was about10m(drms)).

  • PDF

Performance Testing of Integrated Strapdwon INS and GPS

  • Lee, Sang-Joog;Yoo, Chang-Sun;Shim, Yo-Han;Kim, Jong-Chul
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제2권1호
    • /
    • pp.67-77
    • /
    • 2001
  • In recent navigation system, the profitable solution is to integrate the GPS and Stapdwon INS (SDINS) system and its integration allows compensation for shortcomings of each system. This paper describes the hardware preparation and presents the test results obtained from the automobile test of the developed system. The automobile tests was conducted with two kinds of inertial sensors and GPS receivers : short range and middle range test, to verify and evaluate the performance of the integrated navigation system. The reference of position is given by the Differential GPS(DGPS) which has cm-level accuracy to compare the accuracy of system. Kalman filtering is used for integrating GPS and SDINS and this filter effectively allows the long-term stability of GPS to correct and decrease the time deviation error of SDINS.

  • PDF

전차선로 드로퍼 클램프 재질 향상에 관한 연구 (The Improvement of Material Quality for Dropper Clamp on the Catenary System)

  • 김연근;창상훈;오기봉
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2002년도 추계학술대회 논문집(I)
    • /
    • pp.547-552
    • /
    • 2002
  • The research sees the catenary dropper clamp using a test equipment which is using actual sample in the field. This test helps the quality improvement of material. For raising the reliability of data, classified it by type and tests especially in the multiple sample but it was under testing in the sample of decimal at circumstance. From the accuracy side of research data it was insufficient because the dropper clamp was in small quantity but it contributes in quality of material improvement. The quality of material data which it gets with spectroscopic was not accurate so hereafter it needs to follow wet analysis and precise analysis to join in the test which is detailed comes to accomplish with the data accuracy.

  • PDF

주파수 응답함수를 이용한 고정밀장비의 진동 허용규제치 결정기법에 관한 연구 (A Study on the Determination Vibration criteria for High Technology Facilities using FRF - Impact Test-)

  • 이홍기;박해동;김두훈;김사수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1996년도 추계학술대회논문집; 한국과학기술회관, 8 Nov. 1996
    • /
    • pp.377-385
    • /
    • 1996
  • In the case of a precision equipment, it requires a vibration free environment to provide its proper function. Especially, lithography and inspection devices, which have sub-nanometer class high accuracy and resolution, have come to necessity for producing more improved giga class semiconductor wafers. This high technology equipments require very strict environmental vibration standard in proportion to the accuracy of the manufacturing, inspecting devices. The vibration criteria are usually obtained either by the real vibration exciting test on the equipment or by the analytical calculation. the former is accurate but requires a great deal of time and efforts while the latter lacks reliability. this paper proposes a new method to solve this problem at a time. the permissible vibration level to a precision equipment can be easily obtained by analyzing a process of Frequency Response Function. This paper also demonstrates its effectiveness by applying the proposed method to finding the vibration criteria of a Computer Hard Disk Drive by impact Test.

  • PDF

Classification in Different Genera by Cytochrome Oxidase Subunit I Gene Using CNN-LSTM Hybrid Model

  • Meijing Li;Dongkeun Kim
    • Journal of information and communication convergence engineering
    • /
    • 제21권2호
    • /
    • pp.159-166
    • /
    • 2023
  • The COI gene is a sequence of approximately 650 bp at the 5' terminal of the mitochondrial Cytochrome c Oxidase subunit I (COI) gene. As an effective DeoxyriboNucleic Acid (DNA) barcode, it is widely used for the taxonomic identification and evolutionary analysis of species. We created a CNN-LSTM hybrid model by combining the gene features partially extracted by the Long Short-Term Memory ( LSTM ) network with the feature maps obtained by the CNN. Compared to K-Means Clustering, Support Vector Machines (SVM), and a single CNN classification model, after training 278 samples in a training set that included 15 genera from two orders, the CNN-LSTM hybrid model achieved 94% accuracy in the test set, which contained 118 samples. We augmented the training set samples and four genera into four orders, and the classification accuracy of the test set reached 100%. This study also proposes calculating the cosine similarity between the training and test sets to initially assess the reliability of the predicted results and discover new species.

The effects of custom tray material on the accuracy of master cast reproduction

  • Kim Hyun-Kyung;Chang Ik-Tae;Heo Seong-Joo;Koak Jai-Young
    • 대한치과보철학회지
    • /
    • 제39권3호
    • /
    • pp.282-296
    • /
    • 2001
  • The accuracy of master cast reproduction by a polyvinylsiloxane impression material using two visible-light curing resin and autopolymerizing polymethyl methacrylate resin custom tray material was investigated. Custom trays were fabricated from a master cast that had three index points marked on both inner and outer vestibules and then poured in yellow stone. The distance between the reproduced index points were measured to be ${\pm}0.001mm$ with a measuring microscope and the algebraic norms calculated for each tray material. No differences were found in the algebraic norms of inner and outer dimensions for upper tray impressions by ANOVA(p>0.05). However, T-test revealed that there were differences between upper and lower impressions and Tukey's hsd test revealed that in lower tray impressions, the Palatray in inner, the Lightplast in outer dimensions respectively were different from other materials. The index points reproduced on the casts compared with the master cast, were closer together for upper tray impressions. All four tray materials produced acceptable casts, 1. Algebraic norms of inner and outer dimensions of the test casts for upper trays were not statistically different irrespective of materials.(P>0.05) 2. T-test showed that there were differences between means with upper and lower trays especially in outer dimension.(P>0.05) 3. But, algebraic norms of inner and outer dimensions of the test casts for lower trays were statistically different between materials. 4. Palatray XL in inner, Lightplast-platten in outer dimensions respectively for lower trays were different from other materials, but, the nearest to the original model.

  • PDF

요 스트립검사 자동화를 위한 동시 비교 스캔 기법 예비 연구 (Automation of urine dipstick test by simultaneous scanning : A pilot study)

  • 이상봉;최성수;이인광;한정수;김완석;김원재;차은종;김경아
    • 센서학회지
    • /
    • 제19권3호
    • /
    • pp.169-175
    • /
    • 2010
  • Urinalysis is an important clinical test to diagnose urinary diseases, and dipstick method with visual inspection is widely applied in practice. Automated optical devices recently developed have disadvantages of long measurement time, big size and heavy weight, accuracy degradation with time, etc. The present study proposed a new computer scanning technique, in which the test strip and the standard chart were simultaneously scanned to remove any environmental artifacts, followed by automated differentiation with the minimum distance algorithm, leading to significant enhancement of accuracy. Experiments demonstrated an accuracy of 100 % in that all test results were identical with the human visual inspection. The present technique only uses a personal computer with scanner and shortens the test time to a great degree. The results are also stored and accumulated for later use which can be transmitted to remote locations through a network, thus could be easily integrated to any ubiquitous health care systems.

종합검진 후 지방간 환자의 복부 초음파 검사와 임상화학적 검사결과의 정확성 분석 (Analysis of the Accuracy about Abdominal Ultrasonography and Clinical Chemical Test with Fatty Liver Patients on the Medical Examination)

  • 김영재;송종남;김민의
    • 한국방사선학회논문지
    • /
    • 제6권3호
    • /
    • pp.183-189
    • /
    • 2012
  • 초음파 검사는 복강내 장기를 검사하는 대표적인 영상의학검사의 한 분야이며. 혈액검사는 체내 이상 징후를 임상화학적으로 검사하는 대표적인 방법이다. 지방간의 진단은 주로 복부초음파 검사와 혈액검사를 동시에 실시하여 수행하며 두 검사의 결과를 바탕으로 진단을 하게 된다. 이 경우에 실시하는 혈액검사의 기준은 TBIL, TC, AST, ALT, ALP, GGT, TG, HDL-C, GLU의 값이다. 본 연구에서는 초음파 영상에서 지방간 진단을 받은 환자의 혈액검사 정확성을 분석하여 두 종류의 검사간 정확도를 분석하고자 하였다. 2012년 1월부터 3월간 종합검진으로 복부초음파검사와 혈액검사를 동시에 받은 환자 1350명 중 초음파 검사상 지방간 판정을 받은 459명을 대상으로 초음파 검사와 혈액검사 결과가 동일한 경우는 459명 중 280명으로 약 60.8% 이며, 초음파 검사와 혈액검사의 결과가 서로 다른 경우는 179명으로 39.2%로 밝혀져 초음파 검사와 혈액검사의 진단 정확도는 60.8% 이었다. 이는 지방간의 초음파 진단시 종사자의 주관적 능력이 병변의 진단에 큰 영향을 미친 것으로 생각되어 지속적인 초음파 임상 교육이 필요할 것으로 사료된다.

진단법의 임상시험연구와 진단정확도 (Clinical Trials and Accuracy of Diagnostic Tests)

  • 이유경;이상무
    • Journal of Genetic Medicine
    • /
    • 제8권1호
    • /
    • pp.28-34
    • /
    • 2011
  • 대부분의 의사들은 임상시험을 치료약제개발 후 의료현장에서 사용하기 위해 진행되는 과정으로 생각할 것이다. 실험실에서 개발된 기술이 진단검사로써 도입되기 위해서는 치료약제의 경우와 유사한 임상시험 과정을 거쳐 그 안정성과 유효성에 대한 검증을 필요로 한다. 치료약제의 효과검증에서 가장 우수한 근거를 얻을 수 있는 연구방법은 무작위대조연구 방법이지만, 이를 검체진단검사에 그대로 적용하기는 어렵다. 검체진단검사의 경우 비교연구가 진단정확도의 검증을 위해 현실적으로 사용할 수 있는 연구방법이지만 대상군의 모집 방법과 구분 방법, 질환대상자의 질환 심각도, 참고표준의 선택과 적용, 눈가림 여부 등 여러 요인들이 진단정확도 지표에 직접적인 영향을 주기 때문에, 좋은 근거수준의 연구결과를 얻기 위해서는 이러한 요소들을 고려한 잘 고안된 연구디자인이 중요하다. 또한 검체진단검사는 치료약제의 경우와 달리 결과를 얻기 위한 검사과정이 사용자인 일선 검사실에 의해 계속 생산되어야 하고, 검사의 개발과 발전의 속도가 빠르며, 일선검사실이 최종사용자이자 개발자인 경우가 흔하다는 특성이 있다. 저자들은 이러한 검사의 특성을 고려하여 검사법 자체의 수행능력에 대한 검증으로부터 검사법 성능평가를 위한 질환확진군과 정상군에 대한 비교연구, 일련의 질환의심자 대상의 진단정확도 평가와 임상 효과성 평가, 도입 후 일상감시로 이어지는 임상시험의 진행단계를 제안하고자 한다.