• 제목/요약/키워드: accuracy index

검색결과 1,237건 처리시간 0.045초

Effect of Dietary Concentrate:forage Ratios and Undegraded Dietary Protein on Nitrogen Balance and Urinary Excretion of Purine Derivatives in Dorper×thin-tailed Han Crossbred Lambs

  • Ma, Tao;Deng, Kai-Dong;Tu, Yan;Jiang, Cheng-Gang;Zhang, Nai-Feng;Li, Yan-Ling;Si, Bing-Wen;Lou, Can;Diao, Qi-Yu
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제27권2호
    • /
    • pp.161-168
    • /
    • 2014
  • This study aimed to investigate dietary concentrate:forage ratios (C:F) and undegraded dietary protein (UDP) on nitrogen balance and urinary excretion of purine derivatives (PD) in lambs. Four Dorper${\times}$thin-tailed Han crossbred castrated lambs with $62.3{\pm}1.9$ kg body weight at 10 months of age were randomly assigned to four dietary treatments in a $2{\times}2$ factorial arrangement of two levels of C:F (40:60 and 60:40) and two levels of UDP (35% and 50% of CP), according to a complete $4{\times}4$ Latin-square design. Each experimental period lasted for 19 d. After a 7-d adaptation period, lambs were moved into individual metabolism crates for 12 d including 7 d of adaption and 5 d of metabolism trial. During the metabolism trial, total urine was collected for 24 h and spot urine samples were also collected at different times. Urinary PD was measured using a colorimetric method and creatinine was measured using an automated analyzer. Intake of dry matter (DM) (p<0.01) and organic matter (OM) (p<0.01) increased as the level of UDP decreased. Fecal N was not affected by dietary treatment (p>0.05) while urinary N increased as the level of UDP decreased (p<0.05), but decreased as dietary C:F increased (p<0.05). Nitrogen retention increased as dietary C:F increased (p<0.05). As dietary C:F increased, urinary excretion of PD increased (p<0.05), but was not affected by dietary UDP (p>0.05) or interaction between dietary treatments (p>0.05). Daily excretion of creatinine was not affected by dietary treatments (p<0.05), with an average value of $0.334{\times}0.005$ mmol/kg $BW^{0.75}$. A linear correlation was found between total PD excretion and PDC index ($R^2$ = 0.93). Concentrations of creatinine and PDC index in spot urine were unaffected by sampling time (p>0.05) and a good correlation was found between the PDC index (average value of three times) of spot urine and daily excretion of PD ($R^2$ = 0.88). These results suggest that for animals fed ad libitum, the PDC index in spot urine is effective to predict daily excretion of PD. In order to improve the accuracy of the spot sampling technique, an appropriate lag phase between the time of feeding and sampling should be determined so that the sampling time can coincide with the peak concentration of PD in the urine.

용적변조회전 방사선치료에서 선량전달의 중단 및 재시작에 따른 정확성 평가 (The Accuracy Evaluation according to Dose Delivery Interruption and Restart for Volumetric Modulated Arc Therapy)

  • 이동형;배선명;곽정원;강태영;백금문
    • 대한방사선치료학회지
    • /
    • 제25권1호
    • /
    • pp.77-85
    • /
    • 2013
  • 목 적: 용적변조회전 방사선치료는 겐트리 회전과 다엽콜리메이터, 선량률이 연동되어 진행되며 치료 중 선량 전달의 중단이 발생한 경우 겐트리와 다엽콜리메이터가 최초위치부터 다시 동작하여 정지된 지점부터 선량전달이 재개된다. 본 연구는 용적 변조회전 방사선치료의 치료 중단과 재 진행에 따른 선량전달의 오차를 분석하고자 하였다. 대상 및 방법: 10명의 환자를 대상으로 전산화치료계획시스템(Eclipse V10.0, Varian, USA)을 이용하여 용적변조회전 방사선 치료 계획을 수립하였다. TRILOGY (Varian, USA)의 6 MV 선속을 이용하여 계획된 선량을 이차원 배열 검출기와 CUBE (IBA dosimetry, Germany)팬텀에 조사하였다. OmniPro I'mRT system (V1.7b, IBA dosimetry, Germany)을 통해 4회에 걸쳐 일반적인 선량전달의 일관성을 평가 하고 선량 전달의 중단 또는 도어 인터락 발생으로 인해 선량 전달이 중단되고 최초지점부터 다시 시작되어 조사되는 경우와 비교하여 감마지수(Gamma index)의 변화를 분석하였다. 결 과: 선량 전달이 정상적으로 이루어진 경우에 각각의 감마 평균 신호 값의 차이는 0.1로 나타났고, 선량 전달의 중단이 발생한 경우 0.128로 나타났으며 도어 인터락의 경우 0.141로 나타났다. 각각의 경우 감마 표준편차 값의 차이는 0.071, 0.091, 0.099로 나타났고, 감마 최대값의 차이는 0.286, 0.379, 0.413으로 나타났다. Gamma pass rate (3%, 3 mm)는 허용 오차 범위를 만족하였고, T검증 결과 95% 신뢰구간에서 P-value가 0.05 미만으로 유의한 차이를 보였다. 결 론: 본 실험에서 치료 중 선량 전달의 중단 및 재시작에 관한 정확성을 평가해 본 결과 통계적으로는 차이가 있으나 임상적으로 허용 오차 범위이내로 문제가 없다는 것을 알 수 있었다. 그러나 겐트리와 다엽콜리메이터, 선량률의 연동으로 정확성이 요구되는 치료방법인 만큼 선량적인 측면에서 치료 중단에 따른 차이는 간과할 수 없다. 그러므로 갑작스러운 치료 중단 상황이 발생한 경우 추가적인 정도관리 절차를 통해 정확한 선량평가가 이루어져야 할 것으로 사료된다.

  • PDF

두경부암에서 2차원 배열 검출기를 이용한 IMRT QA의 불확실성에 대한 연구 (Evaluation of Uncertainty of IMRT QA Using 2Dimensional Array Detector for Head & Neck Patients)

  • 반태준;이우석;김대섭;백금문;곽정원
    • 대한방사선치료학회지
    • /
    • 제23권2호
    • /
    • pp.97-102
    • /
    • 2011
  • 목 적: 2차원 배열 검출기를 이용하여 세기변조 방사선 치료 품질관리를 시행할 때 정량적 분석을 위한 감마(${\gamma}$) 함수의 적용은 일반적으로 연속적인 선량 분포에 대해 정의되어 있으나 임상적으로 불연속적인 지점에 대해 측정된 값이 이용되고 있으며 이는 감마(${\gamma}$) 지수법을 이용한 평가의 불확실성과 관련이 있을 것으로 사료된다. 본 논문은 두경부암 세기변조 방사선 치료 품질관리의 감마(${\gamma}$) 함수 적용에서 표본 추출 간격에 따른 감마(${\gamma}$) 지수 변화정도를 확인하고 불확실성을 평가하여 유효한 범위를 제시하고자 한다. 대상 및 방법: 본원에서 시행한 두경부 세기변조 방사선 치료 환자 10명을 대상으로 IBA Dosimetry사의 OmniPro I'mRT system software version 1.7b를 이용하여 동일한 두 선량 평가면(Plane)에 대해 분석을 시행하였다. 원점에 위치한 표본 추출 간격 0.1 cm의 선량 평가면을 기준으로 다른 하나의 선량 평가면 위치를 Y축 방향으로 0.0 cm, 0.2 cm, 0.5 cm, 1.0 cm씩 이동 시키면서 Gamma pass rate, Average signal, 측정값에 대한 표준편차의 변화를 관찰하였다. 이때 표본 추출 간격을 0.1 cm, 0.5 cm, 1.0 cm, 2.0 cm, 4.0 cm으로 변화시키면서 Y축 방향으로 동일한 거리를 이동했을 때 Gamma index의 변화를 실험하였다. 결 과: 각 표본추출 간격에 대해 Average signal의 차이는 0, -0.0019, -0.0004, -0.0460, -0.832로 나타났고 측정값에 대한 표준편차의 차이는 0, -0.0030, 0.0124, 0.0070, -0.0799로 나타났으며 Gamma pass rate의 차이는 0, 0.0027, -0.0143, 0.0532, 0.0560의 결과를 보였다. 표본추출 간격 0.1~1.0 cm 범위 내에서는 Average signal과 Gamma pass rate의 차이가 1.5% 이내로 나타났으며 2.0 cm 이상 범위에서는 5% 이상 차이를 보였다. 결 론: 감마(${\gamma}$) 함수의 적용에서 표본추출 간격이 1.0 cm 이하인 경우 실제 분석 값에 대해 1.5% 이내의 차이를 나타냈지만 2.0 cm 이상인 경우 Gamma pass rate이 실제 분석 값보다 5%이상 높게 나타났고 감마(${\gamma}$) 지수의 불확실성과 신뢰수준에 영향을 주었다. 세기변조 방사선 치료의 품질관리를 시행할 경우 표본추출 간격에 따른 감마(${\gamma}$) 지수의 불확실성을 고려하여 임상적으로 2.0 cm 미만의 표본 추출 간격이 적용되어야 할 것으로 사료된다.

  • PDF

Total Scalp의 방사선 치료 시 Helmet Bolus 제작방법에 관한 연구 (Comparison of Three Different Helmet Bolus Device for Total Scalp Irradiation)

  • 송용민;김종식;홍채선;주상규;박주영;박수연
    • 대한방사선치료학회지
    • /
    • 제24권1호
    • /
    • pp.31-37
    • /
    • 2012
  • 목 적: Total Scalp의 방사선 치료 시 표면선량(surface dose)을 증가시키기 위해 조직보상체(bolus)를 사용한다. 이에 본 저자는 두피(scalp) 전체를 덮는 조직보상체로서 Bolx-II, paraffin wax, solid thermoplastic물질을 각각 적용한 Helmet bolus를 제작하여 유용성을 비교 평가해보고자 한다. 대상 및 방법: Rando 팬톰을 이용하여 두피 고정용구(mask)를 만든 후 전체 두피에 Bolx-II (Action Products, USA), paraffin wax (Densply, USA), solid thermoplastic 물질(Med-Tec, USA)을 0.5 cm 두께로 동일하게 적용한 Helmet bolus를 각각 제작 하였다. 각 Helmet bolus에 대한 물리적 특성을 평가하기 위해 전산화 단층촬영(computed tomography) (GE, Ultra Light Speed16)을 시행 후 방사선치료계획시스템(radiation therapy planning system) (Philips, Pinnacle)을 이용하여 최적의 치료 계획(radiationtherapy plan)을 세웠으며, 각 조직 보상체(bolus)에 대한 밀도 변화(density variation)화를 분석하였다. 선량 분포(dose distribution)평가(evaluation)를 위해 선량체적히스토그램(Dose-Volume Histogram) (DVH)을 이용해 임상표적체적(Clinical Target Volume) (CTV)에 대한 Dose-homogeneity index (DHI, $D_{90}/D_{10}$), Conformity index (CI, $V_{95}/TV$)를, 정상 뇌 조직(Normal brain tissue)에 있어$V_{20}$, $V_{30}$을 각각 구하여 비교 하였다. 또한 총 제작시간을 측정하여 제작과정에서의 효율성을 평가하였고, 열형광선량계 (Thermoluminescent Dosimeter)를 사용하여 실제 치료 시 각 두피의 표면선량을 확인 하였다. 결 과: Bolx-II, paraffin wax, solid thermoplastic 물질에 대한 밀도측정(density measurement) 결과 $0.952{\pm}0.13g/cm^3$, $0.842{\pm}0.17g/cm^3$, $0.908{\pm}0.24g/cm^3$로 Bolx-II의 밀도변화(density variation)가 가장 작았다. Bolx-II, paraffin wax, solid thermoplastic 물질을 적용한 각 Helmet bolus DHI는 0.89, 0.85, 0.77, CI는 0.86, 0.78, 0.74로 Bolx-II가 가장 우수 하였으며, 정상조직에 있어 뇌(braintissue)의 $V_{20}$은 11.50%, 10.80%, 10.07%, $V_{30}$은 7.62%, 7.40%, 7.31%로 나타났다. 제작 시 총 소요 시간은 30분, 120분, 90분 이였으며, Bolx-II를 적용한 Helmet bolus 제작과정이 가장 간단하였다. 열형광선량계(Thermoluminescent Dosimeter) 측정 결과세 Helmet bolus 모두 ${\pm}7%$ 이내의 선량오차를 보였다. 결 론: Total Scalp의 방사선치료 시 Bolx-II를 사용한 Helmet bolus의 적용은 CTV (Clinical Target Volume)에 대한 Homogeneity와 Conformity를 높여 줄 뿐만 아니라 제작시간 및 제작방법이 간단하여 임상 적용 시 유용하리라 생각된다.

  • PDF

현실임분 생장특성에 의한 편백 임분수확표 개발 (Development of Stand Yield Table Based on Current Growth Characteristics of Chamaecyparis obtusa Stands)

  • 정수영;이광수;이호상;배은지;박준형;고치웅
    • 한국산림과학회지
    • /
    • 제109권4호
    • /
    • pp.477-483
    • /
    • 2020
  • 본 연구는 남부지방 대표수종인 편백 현실림의 생장 특성을 반영한 수확표를 작성하기 위하여 수행되었다. 200개소 이상의 편백의 표준지 생장조사 자료를 분석에 이용하였다. 기존의 임분수확표 작성 절차인 직경분포의 추정, 적합, 예측의 단계를 거쳤으며, 직경분포모델은 Weibull 함수를 이용하였다. 임지생산력을 평가하기 위한 기준인 지위지수(기준임령 30년)는 Chapman-Richards식을 이용하여 추정하였다. 임분수확표 작성을 위한 평균직경 등 여러 추정식은 적합도를 고려하여 최적의식을 선정하고 이용한 결과, 조사된 편백 현실임분의 지위지수는 10~18 범위에 있음이 밝혀졌다. 추정된 임분재적 모델은 편백림의 임분재적에 대해 62%의 설명력을 가지는 것으로 나타났다. 실재적과 추정재적 간의 잔차도분석 결과 '0'을 중심으로 모두 고른 잔차를 보여 본 추정 결과를 이용함은 문제가 없을 것으로 판단되었다. 이번 남부지방을 대표하는 침엽수인 편백에 대한 임분수확표 작성 결과가 현실의 산림경영에 폭넓게 사용되기를 바라며, 향후 편백 임분 생장이 더욱 안정화되고 생육발달로 장벌기 대경재 생산지가 많이 확보되면 더욱 개선된 수확표의 작성도 가능할 것으로 기대된다.

Effect of Family Size and Genetic Correlation between Purebred and Crossbred Halfsisters on Response in Crossbred and Purebred Chickens under Modified Reciprocal Recurrent Selection

  • Singh, Neelam;Singh, Raj Pal;Sangwan, Sandeep;Malik, Baljeet Singh
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제18권1호
    • /
    • pp.8-12
    • /
    • 2005
  • Response in a modified reciprocal recurrent selection scheme for egg production was evaluated considering variable family sizes and genetic correlation between purebred and crossbred half sisters. The criteria of selection of purebred breeders included pullet's own performance, purebred full and half sisters and crossbred half sister's performance. Heritability of egg production of crossbreds (aggregate genotype) and purebred's was assumed to be 0.2 and genetic correlation between purebred and crossbred half sisters ($r_{pc}$) as 0.1, 0.2, 0.3, 0.4, 0.5, 1.0, -0.1, -0.2, -0.3, -0.4, -0.5 and -1.0. Number of dams per sire to produce purebred and crossbred progenies assumed to be 5, 6, 7, 8, while number of purebred female progeny ($N_p$) and crossbred progeny ($N_c$) per dam were considered to be 3, 4, 5 and 6 in each case. Considering phenotypic variance as unity, selection indices were constructed for different combinations of dams and progeny for each value of $r_{pc}$. Following selection index theory, response in crossbred and purebred for egg production was computed. Results indicated that response in crossbreds depended mainly on crossbred family size and also on magnitude of$r_{pc}$ irrespective of its direction, and response was greater with large crossbred family size than the purebred families. Correlated response in purebreds depends both on magnitude and direction of $r_{pc}$ and was expected to be greater with large purebred family size only. Inclusion of purebred information increased the accuracy of selection for crossbred response for higher magnitude of$r_{pc}$ irrespective of its direction. Present results indicate that desirable response in both crossbred and purebred performance is a function of $r_{pc}$ and family sizes. The ratio of crossbred and purebred family sizes can be optimized depending on the objective of improving the performance of crossbreds and/or of purebreds.

임상실천 평가를 위한 단일체계설계의 적용 -우울증 감소를 위한 인지행동치료에 대한 평가를 중심으로- (Use of Single-System Design to Evaluate the Effectiveness of Cognitive Behavioral Therapy of Depression)

  • 김용석;손동균
    • 한국사회복지학
    • /
    • 제60권2호
    • /
    • pp.175-209
    • /
    • 2008
  • 임상실천의 평가를 위한 도구로 단일체계설계를 강조하는 본 연구는 우울증 치료를 위해 정신과 병원에 입원한 3명의 클라이언트들에게 인지행동치료를 제공하고 개입의 효과성을 평가하기 위해 AB 설계를 사용하였다. 본 연구에 참여하기로 동의한 3명의 클라이언트는 모두 약 2주간의 기초선 단계와 약 3주간의 개입단계에 참가하였다. 평가결과의 타당성을 높이기 위해 다각적 측정원칙을 적용하였고, 기초선 단계와 개입단계 동안 수집된 자료는 시각적인 방법과 통계적인 방법으로 분석되었다. 시각적 분석의 정확성을 높이기 위해 추세선, 추세지수 등과 같은 방법을 활용하여 분석한 결과, 클라이언트 3명의 우울증상이 개입단계에서 모두 나아진 것으로 나타났으며 이러한 개선은 통계적으로도 유의미하였다. 본 연구는 모니터링, 클라이언트를 실천과정에 적극적으로 참여시킬 수 있는 기회 제공, 자료분석의 용이성을 임상실천평가를 위해 단일체계설계를 사용함으로써 얻게 되는 장점으로 들고 있다.

  • PDF

Estimation of Corn Growth by Radar Scatterometer Data

  • Kim, Yihyun;Hong, Sukyoung;Lee, Kyoungdo;Na, Sangil;Jung, Gunho
    • 한국토양비료학회지
    • /
    • 제47권2호
    • /
    • pp.85-91
    • /
    • 2014
  • Ground-based polarimetric scatterometers have been effective tools to monitor the growth of crop with multi-polarization and frequencies and various incident angles. An important advantage of these systems that can be exploited is temporal observation of a specific crop target. Polarimetric backscatter data at L-, C- and X-bands were acquired every 10 minutes. We analyzed the relationships between L-, C- and X-band signatures, biophysical measurements over the whole corn growth period. The Vertical transmit and Vertical receive polarization (VV) backscattering coefficients for all bands were greater than those of the Horizontal transmit and Horizontal receive polarization (HH) until early-July, and then thereafter HH-polarization was greater than VV-polarization or Horizontal transmit and Vertical receive polarization (HV) until the harvesting stage (Day Of Year, DOY 240). The results of correlation analysis between the backscattering coefficients for all bands and corn growth data showed that L-band HH-polarization (L-HH) was the most suited for monitoring the fresh weight ($r=0.95^{***}$), dry weight ($r=0.95^{***}$), leaf area index ($r=0.86^{**}$), and vegetation water content ($r=0.93^{***}$). Retrieval equations were developed for estimating corn growth parameters using L-HH. The results indicated that L-HH could be used for estimating the vegetation biophysical parameters considered here with high accuracy. Those results can be useful in determining frequency and polarization of satellite Synthetic Aperture Radar stem and in designing a future ground-based microwave system for a long-term monitoring of corn.

Sex determination by radiographic localization of the inferior alveolar canal using cone-beam computed tomography in an Egyptian population

  • Mousa, Arwa;El Dessouky, Sahar;El Beshlawy, Dina
    • Imaging Science in Dentistry
    • /
    • 제50권2호
    • /
    • pp.117-124
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate possible differences in the location of the inferior alveolar canal in male and female Egyptians. Materials and Methods: This cross-sectional retrospective study involved the evaluation of 210 CBCT scans of Egyptian individuals (18-70 years old). The inferior alveolar canal was localized by measuring 8 linear dimensions: 2 for the vertical localization of the mental foramen (superior and inferior to the mental foramen), 4 at the first molar bifurcation for the vertical and horizontal localization of the inferior alveolar canal (superior, inferior, buccal, and lingual to the inferior alveolar canal), and 2 for the horizontal localization of the mandibular foramen (anterior and posterior to the mandibular foramen). The measurements were statistically analyzed via comparative analysis, stepwise logistic regression, and receiver operating characteristic (ROC) curve analysis. Results: Six of the 8 measured distances differed to a statistically significant extent between the sexes. Regression analysis suggested a logistic function with a concordance index of 84%. The diagnostic accuracy capabilities of the linear measurements as sex predictors were calculated using ROC analysis, and the 6 best predictors for sex determination were selected and ranked from highest to lowest predictive power. Moreover, combining these 6 predictors increased the predictive power to 84%. Conclusion: The location of the inferior alveolar canal in the Egyptian population varies significantly by sex; accordingly, this anatomic landmark could be used as a reliable indicator of sexual dimorphism.

A Study on the Development of Service Quality Scale in Traditional Market for Big Data Analysis

  • HWANG, Moon-Young
    • 한국인공지능학회지
    • /
    • 제7권1호
    • /
    • pp.23-59
    • /
    • 2019
  • The purpose of this study is to develop a measure of service quality in the traditional market by examining previous research on the service quality of the traditional market studied so far. After defining basic concepts through definition of traditional market and existing studies, 5 categories of configuration items for SERVQUAL measurement in traditional market were made up based on existing researches related to definition of service quality and service quality of traditional market. A survey was conducted on the items that fit the intention of this study and various statistical analyzes were conducted. Statistical analysis was performed using SPSS 22.0 and AMOS 22.0. The reliability of the items was measured by the reliability test, and the predictability and accuracy of the items were examined. The validity of the measured variables was verified through confirmatory factor analysis. Reliability, empathy, responsiveness, certainty, and tangibility were the most important factors in this study. Responsiveness factors include communication, time reduction, real time, promptness. Assurance factors include the assurance of delivery, prompt answers, product knowledge items. Tangibility factors include, convenient device systems, location information, presence as a fact, and as a result, the latest modern items are adopted. The quality of service in the traditional market developed in this study was found to be good in reliability and validity test. Confirmatory factor analysis result using structural equation model also met the conformity index standard. If service satisfaction is measured based on this research, basic data can be presented to policy makers who implement policies on traditional markets to make the right decisions. In addition, it will be able to provide traditional market operators with operational strategy and marketing data. In the future, based on the traditional market service quality scale developed in this study, it is necessary to grasp the factors to be continuously managed to improve the service quality of the traditional market, user satisfaction, and intention to use.