• 제목/요약/키워드: accumulated radiation

검색결과 158건 처리시간 0.022초

핵의학과 주사와 분배업무 작업종사자 및 수시출입자 피폭선량연구 (A Study on Exposure Dose from Injection Work and Elution Work for Radiation Workers and Frequent Workers in Nuclear Medicine)

  • 주용진;동경래;최은진;곽종길;류재광;정운관
    • 방사선산업학회지
    • /
    • 제11권1호
    • /
    • pp.47-54
    • /
    • 2017
  • Compared to other occupations, there is a greater risk of exposure to radiation due to the use of radioisotopes in nuclear medicine for diagnostic evaluations and therapy. To consider ways to reduce exposure dose for those in nuclear medicine involved in injection work and elution work among radiation workers as well as for sanitation workers and trainees among frequent workers an investigation into exposure dose and situational analysis from changes in yearly exposure dose evaluations, changes in work environment and changes in forms of inspection were conducted. Exposure dose measurements were taken by using EPD MK2 worn during working hours for one injection worker, one elution worker, two sanitation workers, and one trainee at a general hospital in the Seoul area for three days from July 18th to 20th 2016. Radiation from radioisotopes which are a part of nuclear medicine can significantly affect not only radiation workers who deal with radioisotopes directly but also frequency works as well. According to this study the annual dose limit for elution workers and injection workers were considered safe as the amount of exposure was not large enough to have a significant effect. The limits of this study consist in the duration of this study and the quantity of participants. Also there was a limitation of the measurement device involving accumulated exposure, where the EPD MK2 cannot check the changes in exposure according to a particular activity.

촬상관타입의 원격모듈화 내방사선 카메라시스템 연구 (The Study on the Radiation-Proof Video Camera system Remote Module of the Tube type)

  • 백동현
    • 한국정보전자통신기술학회논문지
    • /
    • 제11권6호
    • /
    • pp.793-799
    • /
    • 2018
  • CCD카메라는 방사선에 쉽게 열화되어 고방사선구역에서는 촬상관을 이용한 일체화된 카메라가 사용되고 있다. 이를 방사선에 강한 전자부품을 사용한 카메라헤드부와 방사선에 약한 TR, IC등을 사용한 원격제어부로 분리제작한 내 방사선 카메라시스템을 구현하였다. 실험결과 전자부품 중 가장 먼저 손상된 것은 수평 및 수직 동기 발생 IC이었으며 $2{\times}10^5{\sim}10^6rad$의 방사선이 누적되면 정상적인 기능이 상실됨을 확인하였다. 또한 원격화를 위한 신호전송 케이블은 입출력 버퍼회로를 부가하고 쉴드와 케이블의 폐루프면적을 감소시켜 신호 손실보정 및 노이즈를 제거하였다. 따라서 전체의 시스템을 교체하는 것이 아니라 카메라 헤드부분만을 교체하여 사용할 수 있으므로 실용적이며 관리 유지비용이 많이 절감 될 것으로 기대된다.

$\gamma$선 실시간 검출을 위한 P채널 Power MOSFET 방사선 선량 시스템 개발 (Development of Radiation Dosimeter on P Channel Power MOSFET for $\gamma$-rays Real-Time Detection)

  • 한상현;지용근;권오상;민홍기;이응혁
    • 센서학회지
    • /
    • 제9권3호
    • /
    • pp.213-223
    • /
    • 2000
  • 원자력 관련시설이나 우주 공간, 방사선 치료 센터 등에서 발생되는 방사선량은 정확히 검출되어야 할 필요성이 있다. 본 논문에서는 상용 P채널 Power MOSFET(metal oxide field effect transistor)를 방사선 누적선량 모니터링 센서로 활용하기 위해 실시간 방사선량 검출 측정 시스템을 설계 제작하였고, 시스템의 성능을 분석하기 위하여 Co-60 $\gamma$선원을 갖춘 고준위 조사시설에서 조사한 후 출력특성의 변화를 분석하였다. 방사선 조사실험 결과 P채널 Power MOSFET은 조사된 누적 방사선량에 비례하여 문턱전압($V_T$)이 변화됨과 곡선 변화의 선형적 특성을 지님을 알 수 있었다. 이 선형 함수관계를 이용하여 저가의 상용 P채널 Power MOSFET를 사용한 방사선 총 누적선량을 모니터링하기 위한 센서로 사용할 수 있음을 확인하였다.

  • PDF

영상유도 및 호흡동조 방사선치료에서의 영상장비에 의한 흡수선량 분석 (Analysis of the Imaging Dose for IGRT/Gated Treatments)

  • 신정석;한영이;주상규;신은혁;홍채선;안용찬
    • Radiation Oncology Journal
    • /
    • 제27권1호
    • /
    • pp.42-48
    • /
    • 2009
  • 목적: 영상유도방사선치료(IGRT)와 호흡동조방사선치료(4DRT)의 도입은 치료계획 및 치료부위 확인에서 환자에게 방사선 조사량을 증가시킬 가능성이 있다. 따라서 IGRT/4DRT용 영상장비와 기존 장비에서 영상선량을 측정 및 비교하였다. 대상 및 방법: IGRT 및 4DRT를 위해 새로이 도입된 4DCT (GE, Ultra Light Speed 16)와 모의치료기(Varian Acuity), 그리고 치료기(Varian IX)에 장착된 kVp (OBI)의 영상장비 및 EPID (aSi 1000)를 대상으로, RANDO 팬톰의 표면 선량을 측정하여 기존의 장비들(single slice CT (GE, Light Speed), 모의치료기(Varian, Ximatron), L-gram (Varian 2100C))과 비교하였다. 측정은 열형광선량계를 이용하여 두뇌부, 눈, 갑상선, 흉부, 복부 및 골반부의 표면에서 측정하였다. 결과: 기존 CT와 비교하여 4DCT모드에서는 흉부와 복부에서 10배 이상의 선량증가를 보였다($1.74{\pm}0.34$ vs $23.23{\pm}3.67$ cGy). Acuity에서의 선량은 모든 측정부위에서 Ximatron보다 감소하였다($0.91{\pm}0.89$ vs $6.77{\pm}3.56$ cGy). EPID는 기존 L-gram 선량의 약 50% ($1.83{\pm}0.36$ vs $3.80{\pm}1.67$ cGy)였다. OBI의 투시영상선량은 $0.97{\pm}0.34$ cGy며, CBCT 선량은 $2.3{\pm}0.67$ cGy였다. 결론: 4DCT가 선량증가의 가장 큰 원인이며, OBI와 CBCT에 의한 선량은 적으나 매번 치료에 적용 시 총 선량 증가에 대한 고려가 필요하다.

정지궤도 위성자료를 이용한 지표면 도달 태양복사량 연구 (A Study on the Retrievals of Downward Solar Radiation at the Surface based on the Observations from Multiple Geostationary Satellites)

  • 지준범;조일성;이규태
    • 대한원격탐사학회지
    • /
    • 제29권1호
    • /
    • pp.123-135
    • /
    • 2013
  • 정지기상 위성의 가시채널에서 관측되는 반사도는 지상의 일사량 관측자료와 비교하여 구름량 계산이 가능하며 이를 이용하여 지표면에 도달되는 일사량을 추정할 수 있다. 기상 센서(MI)의 경우는 675 nm 파장으로 관측된 반사도를 이용하며 해양 센서(GOCI)는 기상 센서(MI)의 관측파장과 유사한 660 nm, 680 nm 파장으로 관측된 자료를 이용할 수 있다. 연구를 위하여 태풍이 있었던 흐린 날과 맑은 날을 선정하였으며 정지위성으로부터 관측된 자료들을 이용하였다. 위성영상의 반사도가 40%이상 높은 화소들은 0.3이하의 청천지수가 나타났으며 70%이상의 태양에너지가 차폐되었다. 또한 15%이하의 반사도가 나타나는 화소들은 0.9이상의 청천지수가 나타났으며 90%이상의 태양에너지가 지표면에 도달되었다. 계산된 일누적 일사량은 기상청 22개 관측소의 관측 일누적 일사량과 비교하였다. COMS와 MTSAT의 MI센서의 경우 관측값과 비교하여 다소 작게 계산되었으며 GOCI센서를 이용한 계산결과인 상관계수 0.96보다 낮은 0.94와 0.93의 상관성을 보였다. 그리고 일사량 관측값에 대한 RMSE는 MTSAT, COMS MI, GOCI순으로 2.21, 2.09, 2.02 MJ/$m^2$로 나타났다. 또한 COMS GOCI센서의 일누적 계산결과를 지상 관측자료와 비교하였을 때 흐린 날과 맑은 날의 상관성은 각각 0.96과 0.86이었으며 RMSE는 1.82 MJ/$m^2$와 2.27 MJ/$m^2$로서 흐린 날의 상관성이 높게 나타났다. COMS 위성의 해양 센서는 기상센서와 비교하여 관측시각이 한정적이고 관측의 불연속이 있으나 높은 해상도의 이점이 있기 때문에 태양에너지 분석 등의 연구에 유용할 것으로 사료된다.

코로나 대전을 통한 옥외용 고분자 절연재료의 자외선 열화특성 연구 (Study on UV degradation in Polymeric Insulating Materials for Use in Outdoor Insulators by Corona-Charging)

  • 연복희;안종식;이상용;허창수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.106-109
    • /
    • 2001
  • In this paper, we have investigated the degradation of shed materials of outdoor insulators by UV-radiation by using corona-charging and XPS analysis. The accumulated charges on polymeric surface having intrinsic hydrophobic property have a negative impact on retaining its hydrophobicity. Therefore, shorter decay times of surface charges are preferred. The surface voltage decay on UV-treated silicone rubber and EPDM show a different decay trend with UV treated time. From the XPS analysis, the oxidized groups of silica-like structure in silicone rubber increase with UV treatment time. For EPDM, the oxidized carbon groups of C=O, O=C-O increase as elapse of UV radiation time. These oxidized surface for each material have different electrostatic characteristics, so deposited charges may be expected to have different impacts on their surface hydrophobicity. The degradation mechanism based on our results is discussed.

  • PDF

Extension Test of Midday Apparent Evapotranspiration toward Daily Value Using a Complete Remotely-Sensed Input

  • Han, Kyung-Soo;Kim, Young-Seup
    • 대한원격탐사학회지
    • /
    • 제19권5호
    • /
    • pp.341-349
    • /
    • 2003
  • The so-called B-method, a simplified surface energy budget, permits calculation of daily actual evapotranspiration (ET) using remotely sensed data, such as NOAA-AVHRR. Even if the use of satellite data allows estimation of the albedo and surface temperature, this model requires meteorological data measured at ground-level to obtain the other inputs. In addition, a difficulty may be occurred by the difference of temporal scales between the net radiation in daily scale and instantaneous measurement at midday of the surface and air temperatures because the data covered whole day are necessary to obtain accumulated daily net radiation. In order to solve these problems, this study attempted a modification of B-method through an extension of hourly ET value calculated using a complete instantaneous inputs. The estimation of the daily apparent ET from newly proposed system showed a root mean square error of 0.26 mm/day as compared the output obtained from the classical model. It is evident that this may offer more rapid estimation and reduced data volume.

방사선 측정장치의 저준위 방사선 측정과 방사선량의 급격한 변화에 따른 장치의 반응 속도개선에 관한 연구 (A Study On Low Radiation Measurement of Radiation Measuring Devices and Improvement of Reaction Speed according to the Rapid Change of Radiation Dose)

  • 이주현;이승호
    • 전기전자학회논문지
    • /
    • 제18권4호
    • /
    • pp.544-551
    • /
    • 2014
  • 본 논문에서는 방사선 측정장치의 저준위 방사선 측정 알고리즘과 방사선량의 급격한 변화에 따른 장치의 반응 속도개선을 위한 알고리즘 및 장치의 구성을 제안한다. 저준위 방사선 측정의 측정 정밀도를 개선하기 위한 알고리즘은 방사선 측정센서로부터 수집된 펄스의 누적평균을 기준으로 하는 듀얼 윈도우 방사선 수치 측정법을 사용한다. 방사선량의 급격한 변화에 따른 장치의 반응 속도개선을 위한 알고리즘은 신규로 입력된 6초 동안의 데이터 패턴분석을 통한 듀얼 윈도우 방사선 수치 측정법을 사용한다. 제안된 알고리즘의 검증을 위한 하드웨어 장치로는 센서 및 고전압 발생부, 제어부, 충전 및 전원회로부, 무선통신부, 디스플레이부 등으로 구성되어 있다. 제안된 알고리즘에서 사용한 듀얼 윈도우 방사선 수치 측정법을 실험한 결과, 기존 5uSv/h 수준의 저선량 한계에서 대체로 불확도가 낮아지고 선형성이 개선됨을 확인할 수 있었다. 또한 급격한 방사선량의 변화에 대한 장비의 반응속도 개선에 대해 실측실험을 통해 6초 이후에 변화된 수치가 반응함을 확인하였다. 따라서 제안된 알고리즘이 급격한 변화에 따른 장치의 반응속도가 개선됨을 확인할 수 있었다.

방사선 작업종사자의 피폭선량 비교 평가 (Comparative evaluation of radiation exposure in radiation-related workers)

  • 백성민;장은성
    • 한국방사선학회논문지
    • /
    • 제5권4호
    • /
    • pp.195-200
    • /
    • 2011
  • 최근의 방사선 피폭 선량을 조사하여 그 경각심을 일깨워주기 위함이다. 그 분석결과, K병원의 2008년도 평균피폭 선량은 $0.75{\pm}0.26mSv$, 2009년은 $0.67{\pm}0.30mSv$, 2010년은 $0.92{\pm}0.33mSv$였다. P병원은 2008년이 $0.43{\pm}0.13mSv$, 2009년 $0.43{\pm}0.20mSv$, 2010년이 $0.33{\pm}0.85mSv$로 나타났으며, 연령별 평균 피폭선량은 K병원의 20대가 13.39mSv, 30대 8.37mSv, 40대 1.19mSv, 50대 0.28mSv, 60대 0.32mSv로 나타났고 P병원은 20대 0.33mSv, 30대 1.41mSv, 40대 0.83mSv, 50대 1.66mSv, 60대 1.12mSv 였다. 또한 3년간 피폭선량의 평균을 성별로 나누어서 나타냈는데 K병원에서 남자의 피폭선량은 $2.92{\pm}1.03mSv$, 여자의 피폭선량은 $0.94{\pm}0.93mSv$였다. P병원에서의 남자의 피폭 선량은 $0.66{\pm}0.18mSv$이고 여자는 $1.80{\pm}0.60mSv$로 나타났다. 방사선을 취급하는 과별로 받는 년간 평균 피폭 선량은 영상의학과 $1.65{\pm}1.54mSv$, 방사선종양학과 $1.17{\pm}0.82mSv$, 핵의학과 $1.79{\pm}1.42mSv$, 기타 $0.99{\pm}0.51mSv$였으며 상대적으로 저선량율 에너지를 사용하는 핵의학과에서 다른 과와 비교해서 방사선 피폭이 높게 나타났으며(p<0.05), 핵의학과내에서는 특히 동위원소 조작실과 주입실의 년간 평균 피폭량이 $3.69{\pm}1.81mSv$으로 많은 피폭을 받고 있었다(p<0.01). 직종별 연평균 피폭선량은 의사 $1.75{\pm}1.17mSv$, 방사선사 $1.60{\pm}1.39mSv$, 간호사 $0.93{\pm}0.35mSv$, 기타 $1.00{\pm}0.3mSv$로 의사와 방사선사가 다른 직종에 비해 높게 나타났다(p<0.05). 방사선 작업 종사자에 대한 피폭측정 및 평가가 철저히 이루어져 피폭 가능성을 줄이는데 관심과 주의가 필요하며 누적 선량을 최소화하여 방사선 작업 종사자의 건강을 유지하고 증진 시켜야 할 것이다.

박막트랜지스터의 방사선 내구성 평가 (Radiation Resistance Evaluation of Thin Film Transistors)

  • 전승익;이봉구
    • 한국방사선학회논문지
    • /
    • 제17권4호
    • /
    • pp.625-631
    • /
    • 2023
  • 24시간/7일 동안 높은 관전압 하에서 높은 프레임 속도로 검사 대상체의 불량을 검사하는 산업용 동영상 엑스레이 디텍터의 중요한 요구사양은 높은 방사선 내구성을 확보하는 것이다. 본 연구는 비정질 실리콘 (a-Si), 다결정 실리콘 (Poly-Si), In-Ga-Zn-O 산화물 (IGZO) 등의 반도체 층을 갖는 다양한 박막트랜지스터를 제작하여 각각의 방사선 내구성을 확인하였다. a-Si TFT 대비 수십 배 높은 전계효과 이동도로 고속 동영상 구현이 가능한 IGZO TFT의 경우, IGZO 반도체 층과 층간절연막 사이에 수소화 처리를 진행할 경우 산업용 요구사양인 10,000 Gy 누선선량까지 엑스레이 영상센서로 적용 가능한 수준 이상으로 전기적 특성의 변화가 없음을 확인하였다. 따라서 수소화한 IGZO TFT는 방사선 내구성을 확보함과 동시에 높은 전계효과 이동도로 동영상 디텍터의 영상센서에 적용 가능한 유일한 소자임을 확인하였다.