• Title/Summary/Keyword: accident analysis

Search Result 3,886, Processing Time 0.031 seconds

Analysis of Risk Factors in Coronary Artery Bypass Surgery (관동맥우회술의 위험인자 분석)

  • 정태은;한승세
    • Journal of Chest Surgery
    • /
    • v.31 no.11
    • /
    • pp.1049-1055
    • /
    • 1998
  • Background: Coronary artery bypass surgery is an important treatment for ischemic heart disease. Recently operative mortality and morbidity has decreased, however further improvement is necessary. Materials and methods: This study was designed to evaluate the risk of operative mortality and morbidity by retrospective method. From 1992 to 1997, eighty six patients underwent coronary artery bypass surgery. There were 61 males and 25 females aged 36~74 years(mean, 58.6). Fourteen patients(16%) had previous PTCA or stent insertion, 41 patients(48%) had unstable angina, and 45 patients(52%) had three vessel disease. Patients with low LV ejection fraction(<35%) were 7 cases and urgent or emergent operation were 10 cases. There were 6 cases of combined surgery which were mitral valve replacement(2 cases), aortic valve replacement(2 cases), ASD repair(1 case), and VSD repair(1 case). Average number of distal anastomosis was 3.5 per patient and average aortic cross clamp time was 115±38.3min. Preoperative risk factors were defined as follows: female, old age(>70 years), low body surface area(<1.5M2), PTCA or stent insertion history, hypercholesterolemia, smoking, hypertension, DM, COPD, urgent or emergent operation, left main disease, low LV ejection fraction(<35%), and combined surgery. Results: Operative mortality was 7cases(8%). As a postoperative morbidity, perioperative myocardial infarction was 6 cases, cerebrovascular accident 6 cases, reoperation for bleeding 5 cases, acute renal failure 4 cases, gastrointestinal complication 3 cases, and mediastinitis 3 cases. In the evaluation of operative risk factors, low body surface area, DM and low LV ejection fraction were found to be predictive risk factors of postoperative morbidity(p<0.05), and low ejection fraction was especially a risk factor of hospital mortality(p<0.05). Conclusions: In this study, low body surface area, DM and low LV ejection fraction were risk factors of postoperative morbidity and low ejection fraction was a risk factor of hospital mortality.

  • PDF

A Study on Nursing Service of Chronic Diseases by the First Step and Third Step Medical Treatment (1차 및 3차 진료기관 이용 만성질환자의 간호서비스에 관한 연구)

  • Cho Chong Sook
    • Journal of Korean Public Health Nursing
    • /
    • v.10 no.2
    • /
    • pp.103-118
    • /
    • 1996
  • It is to be growing up the interest of community health affairs through visiting nursing care. The health medical treatment of Korea has been changed largely on the period. The juvenile population has decreased. This means that is has took the population consensus of advanced national organization to be increased by the old age. The transition of disease has changed from the contagious disease importance to the chronicity disease omportance because the domestic district population has experienced the sudden urbanization circumstance district population has experienced the sudden urbanization circumstance to be growing up $70\%$ of the whole population. When the nursing service has common function to be delivering from all direction to home, this study is getting the great important phase velocity in order to manage the kernel questional adult chronicity disease of health medical institution at the present age. (1) community over system or with people particularity (2) the first of third step medical treatments. The variety of medical treatments organization has quantity of the delivery manpower and specially between consumers and rdlated person. A qualitative difference is showed at the purpose to be seizing. That research related person is use at district health center in Seoul, by foundation on nurse registration book of H collage hospital and public health registration book. According the chronicity disease. age. and sex. nature agree-able standard 54 people took the content analysis on nurse registration book of total 108 people. The results of the study were as follows: 1. General background factors are houses or kind of medical facilities and number of patients in family. The first medical treatment is more patients than third medical treatment organization. The first medical treatment of economic environment os appering to be worse. 2. The chronicity disease frequency have been different speciality according to medical treatment organization. On case of the first medical treatment. Diabetes and High Blood Pressure were good but Cerebrum Vascular Accident(CVA) showed many for bed case. In addition. the number of family is comparative large exception of CVA on according for moving condition and health more than the first medical treatment. However. family condition. whole family percentage is decreasing preferably through the potential resource is increasing by the number of and the construction of family. The ability of real resource is considered to be low. 3. The average percentage of nurse service has appered to be differed two groups by the first step medical treatment(33.72 times) and third step medical treatment(45.70 times). However, the difference (the first step medical treatment and third step medical treatment) is to be limited to issue the medicine at the service. The condition of nurse care was the indirect nursing care. Supportiong area was to be related to volunteer service and administration support. 4. The various nursing care average percentage of the chronicity disease was increased by orders of Diabetes. High Blood Pressure. and CVA in examination result and the medical treatment. The indirect nursing care was also same. At third step medical treatment, orders of chronicity disease were same. The case of other area on service conditions were increased by order of Diabetes. High Blood Pressure, and CVA. However. it is never appearing the difference at bottleneck affairs nursing care. 5. When the visiting nursing care demand particularly. the average percentage of nursing care from the first step medical treatment that the time under a person is many more than the time over two people. However, there was no difference in statistic. Third step medical treatment is $49.81\%$ at the time under a person. The average nursing care service is appeared by more many when the visiting nursing care demand is a few by 12.83 at the time over two people. 6. By visiting nursing care percentage to be frequency that nursing care averaghe percentage and inter-relation are large. The related factor of the first medical treatment is 0.96. However, the related factor of third medical treatment has shown the decreased 0.49 for the condition of relation more than that. Therefore. the nursing care average percentage is related to the visiting times of a nurse. This result is be showing the obvious fact that the first step medical treatment is few more than third step medical treatment.

  • PDF

Estimation of the Superelevation Safety Factor Considering Operating Speed at 3-Dimensional Alignment (입체선형의 주행속도를 고려한 편경사 안전율 산정에 관한 연구)

  • Park, Tae-Hoon;Kim, Joong-Hyo;Park, Je-Jin;Park, Ju-Won;Ha, Tae-Jun
    • Journal of Korean Society of Transportation
    • /
    • v.23 no.7 s.85
    • /
    • pp.159-163
    • /
    • 2005
  • The propriety between suppliers and demanders in geometric design is very important. Although the final purpose of constructing roads is to concern about the driver s comfort, unfortunately, it has not been considered so far. We've considered the regularity and quickness in considering driver's comfort but there should be considered the safety for the accident as well. If drivers are appeared to be more speeding than designer's intention, there will be needed some supplements to increase the safety rate for the roads. Even if both an upward and downward section are supposed to exist at the same time for solid geometry of the roads like this, it is true that the recent design for the 3-D solid geometry section has been done as flat 2-D and the minimum plane curve radius and the maximum cant have been decided just by calculating without considering operating speed between an upward and downward section at the same point. In this investigation, thus, I'd like to calculate the safety of the cant by considering the speed features of the solid geometry for the first lane of four lane rural roads. To begin with, we investigated the driving speed of the car, which is not been influenced by a preceding car to analyze the influence of the geometrical structure by using Nc-97. Secondly, we statistically analyzed the driving features of the solid geometry after comparing the 6 sections, that is, measuring the driving speed feature at 12 points and combining the influence of the vertical geometry and plane geometry to the driving speed of the plane curve which was researched before. Finally, we estimated the value of cant which considers the driving speed not by using it which has applied uniformly without considering it properly, though there were some differences between a designed speed and driving speed through the result of the basic statistical analysis but by introducing the new safety rate rule, a notion of ${\alpha}$. As a result of the research, we could see the driving features of the car and suggest the safety rate which considers these. For considering the maximum cant, if we apply the safety rate, the result of this experiment, which considers 3-D solid geometry, there'll be the improvement of the driver's safety for designing roads. In addition, after collecting and analyzing the data for the road sections which have various geometrical structures by expanding this experiment it is considered that there should be developed the models which considers 3-D solid geometry.

A Study on the Black Box Design using Collective Intelligence Analysis (집단지성 분석법을 활용한 블랙박스 디자인 개발 연구)

  • Lee, Hee young;Hong, Jeong Pyo;Cho, Kwang Soo
    • Science of Emotion and Sensibility
    • /
    • v.21 no.2
    • /
    • pp.101-112
    • /
    • 2018
  • This study was carried out to enhance the competitiveness of blackbox design for domestic and international companies, based on the explosive growth of the blackbox market due to development of blackbox design for vehicle accident prevention and post-treatment. In the past, the blackbox market has produced products indiscriminately to meet the ever-increasing demand of consumers. Therefore, we thought a new design method was necessary to effectively investigate the needs of rapidly changing consumers. In this study, we aimed to identify the best-selling blackbox to understand the design flow, and the optimum area for a blackbox, considering the uniqueness of associated vehicle. Based on discussion with blackbox design experts, we studied the direction of design and the problems with blackbox use, which were reflected in blackbox development. Through this research, two types of design - leading blackbox (A type) and mass production blackbox (B type) - were proposed for compatibility of the blackbox with the car. The leading type of blackbox was positioned so that it was wrapped with the room mirror hinge before the screw was fastened, in order to achieve an integrated design. Therefore, we designed an integrated form and resolved the placement problem of an adhesive blackbox. To blend, the mass production blackbox implemented material and surface processing in the same way with the car, and adopted the slide structure to automatically turn off the main body power when removing the SDcard, reflecting consumer needs. This study considers evolving consumer needs through a case study and collective intelligence and deals with implementation of the whole design process during mass production. In this study, we aimed to strengthen the competitiveness of the blackbox design based on design method and its realization.

Oil Fluorescence Spectrum Analysis for the Design of Fluorimeter (형광 광도계 설계인자 도출을 위한 기름의 형광 스펙트럼 분석)

  • Oh, Sangwoo;Seo, Dongmin;Ann, Kiyoung;Kim, Jaewoo;Lee, Moonjin;Chun, Taebyung;Seo, Sungkyu
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.18 no.4
    • /
    • pp.304-309
    • /
    • 2015
  • To evaluate the degree of contamination caused by oil spill accident in the sea, the in-situ sensors which are based on the scientific method are needed in the real site. The sensors which are based on the fluorescence detection theory can provide the useful data, such as the concentration of oil. However these kinds of sensors commonly are composed of the ultraviolet (UV) light source such as UV mercury lamp, the multiple excitation/emission filters and the optical sensor which is mainly photomultiplier tube (PMT) type. Therefore, the size of the total sensing platform is large not suitable to be handled in the oil spill field and also the total price of it is extremely expensive. To overcome these drawbacks, we designed the fluorimeter for the oil spill detection which has compact size and cost effectiveness. Before the detail design process, we conducted the experiments to measure the excitation and emission spectrum of oils using five different kinds of crude oils and three different kinds of processed oils. And the fluorescence spectrometer were used to analyze the excitation and emission spectrum of oil samples. We have compared the spectrum results and drawn the each common spectrum regions of excitation and emission. In the experiments, we can see that the average gap between maximum excitation and emission peak wavelengths is near 50 nm for the every case. In the experiment which were fixed by the excitation wavelength of 365 nm and 405 nm, we can find out that the intensity of emission was weaker than that of 280 nm and 325 nm. So, if the light sources having the wavelength of 365 nm or 405 nm are used in the design process of fluorimeter, the optical sensor needs to have the sensitivity which can cover the weak light intensity. Through the results which were derived by the experiment, we can define the important factors which can be useful to select the effective wavelengths of light source, photo detector and filters.

A Methodology of Ship Detection Using High-Resolution Satellite Optical Image (고해상도 광학 인공위성 영상을 활용한 선박탐지 방법)

  • Park, Jae-Jin;Oh, Sangwoo;Park, Kyung-Ae;Lee, Min-Sun;Jang, Jae-Cheol;Lee, Moonjin
    • Journal of the Korean earth science society
    • /
    • v.39 no.3
    • /
    • pp.241-249
    • /
    • 2018
  • As the international trade increases, vessel traffics around the Korean Peninsula are also increasing. Maritime accidents hence take place more frequently in the southern coast of Korea where many big and small ports are located. Accidents involving ship collision and sinking result in a substantial human and material damage as well as the marine environmental pollution. Therefore, it is necessary to locate the ships quickly when such accidents occur. In this study, we suggest a new ship detection index by comparing and analyzing the reflectivity of each channel of the Korea MultiPurpose SATellite-2 (KOMPSAT-2) images of the area around the Gwangyang Bay. A threshold value of 0.1 is set based on a histogram analysis, and all vessels are detected when compared with RGB composite images. After selecting a relatively large ship as a representative sample, the distribution of spatial reflectivity around the ship is studied. Uniform shadows are detected on the northwest side of the vessel. This indicates that the sun is in the southeast, the azimuth of the actual satellite image is $144.80^{\circ}$, and the azimuth angle of the sun can be estimated using the shadow position. The reflectivity of the shadows is 0.005 lower than the surrounding sea and ship. The shadow height varies with the position of the bow and the stern, perhaps due to the relative heights of the ship deck and the structure. The results of this study can help search technology for missing vessels using optical satellite images in the event of a marine accident around the Korean Peninsula.

A Comment on the Standard for International Jurisdiction to foreign-related cases by the employment contract and tort in Air crash (항공기사고에서 국제근로계약과 불법행위의 국 제재판관할권 판단기준)

  • Cho, Jeong-Hyeon;Hwang, Ho-Won
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.31 no.2
    • /
    • pp.73-98
    • /
    • 2016
  • This is a case review of the Korean Supreme Court about international jurisdiction over a foreign-related case. This case is a guideline to other following cases how Korean court has international jurisdiction over the foreign elements cases. This case was an air crash accident in Busan, Korea. And the applicant was a chinese who was parents of flight attendant. The defendant was Air China. The applicant suid the defendant in Korea court, requesting for compensation for damages based on the contract of employment between died employee and the defendant and tort. The trial court rejected jurisdiction. But Supreme court granted jurisdiction on Korean court. The court determined the jurisdiction by the Korean Private International Law Act(KPILA). The KPILA has a concept of 'substantial connection', it is a main legal analysis to determine the jurisdiction. In the act, Article 2 Paragraph 1 says "In case a party or a case in dispute is substantively related to the Republic of Korea, a court shall have the international jurisdiction. In this case, the court shall obey reasonable principles, compatible to the ideology of the allocation of international jurisdiction, in judging the existence of the substantive relations." And Article 2 Paragraph 2 declares "A court shall judge whether or not it has the international jurisdiction in the light of jurisdictional provisions of domestic laws and shall take a full consideration of the unique nature of international jurisdiction in the light of the purport of the provision of paragraph (1)." In this case review find concepts, theories and cases out to clarify the meaning about Article 2 of the KPILA. Also it quoted from the concept of "the base rule" in Rome I (Regulation (EC) 593/2008 on the law applicable to contractual obligations) to apply the contract of employment between flight attendant and Air carrier.

A basic research for evaluation of a Home Care Nursing Delivery System (가정간호 서비스 질 평가를 위한 도구개발연구)

  • Kim, Mo-Im;Cho, Won-Jung;Kim, Eui-Sook;Kim, Sung-Kyu;Chang, Soon-Bok;Ryu, Ho-Sihn
    • Journal of Home Health Care Nursing
    • /
    • v.6
    • /
    • pp.33-45
    • /
    • 1999
  • The purpose of this study was to develop a basic framework and criteria for evaluation of quality care provided to patients with the attributes of disease in the home care nursing field, and to provide measurement tools for home health care in the future. The study design was a developmental study for evaluation of hospital-based HCN(home care nursing) in Korea. The study process was as follows: a home care nursing study team of College of Nursing. Yonsei University reviewed the nursing records of 47 patients who were enrolled at Yonsei University Medical Center Home Care Center in March, 1995. Twenty-five patients were insured at that time, were selected from 47 patients receiving home care service for study feasibility with six disease groups; Caesarean Section (C/S), simple nephrectomy, Liver cirrhosis(LC), chronic obstructive pulmonary disease(COPD), Lung cancer or cerebrovascular accident(CVA). In this study, the following items were selected : First step : Preliminary study 1. Criteria and items were selected on the basis of related literature on each disease area. 2. Items were identified by home care nurses. 3. A physician in charge reviewed the criteria and content of selected items. 4. Items were revised through preliminary study offered to both HCN patients and discharged patients from the home care center. Second step : Pretest 1. To verify the content of the items, a pretest was conducted with 18 patients of which there were three patients in each of the six selected disease groups. Third step : Test of reliability and validity of tools 1. Using the collected data from 25 patients with either cis, Simple nephrectomy, LC, COPD, Lung cancer, or CVA. the final items were revised through a panel discussion among experts in medical care who were researchers, doctors, or nurses. 2. Reliability and validity of the completed tool were verified with both inpatients and HCN patients in each of field for researches. The study results are as follows: 1. Standard for discharge with HCN referral The referral standard for home care, which included criteria for discharge with HCN referral and criteria leaving the hospital were established. These were developed through content analysis from the results of an open-ended questionnaire to related doctors concerning characteristic for discharge with HCN referral for each of the disease groups. The final criteria was decided by discussion among the researchers. 2. Instrument for measurement of health statusPatient health status was measured pre and post home care by direct observation and interview with an open-ended questionnaire which consisted of 61 items based on Gorden's nursing diagnosis classification. These included seven items on health knowledge and health management, eight items on nutrition and metabolism, three items on elimination, five items on activity and exercise, seven items on perception and cognition, three items on sleep and rest, three items on self-perception, three items on role and interpersonal relations, five items on sexuality and reproduction, five items on coping and stress, four items on value and religion, three items on family. and three items on facilities and environment. 3. Instrument for measurement of self-care The instrument for self-care measurement was classified with scales according to the attributes of the disease. Each scale measured understanding level and practice level by a Yes or No scale. Understanding level was measured by interview but practice level was measured by both observation and interview. Items for self-care measurement included 14 for patients with a CVA, five for women who had a cis, ten for patients with lung cancer, 12 for patients with COPD, five for patients with a simple nephrectomy, and 11 for patients with LC. 4. Record for follow-up management This included (1) OPD visit sheet, (2) ER visit form, (3) complications problem form, (4) readmission sheet. and (5) visit note for others medical centers which included visit date, reason for visit, patient name, caregivers, sex, age, time and cost required for visit, and traffic expenses, that is, there were open-end items that investigated OPD visits, emergency room visits, the problem and solution of complications, readmissions and visits to other medical institution to measure health problems and expenditures during the follow up period. 5. Instrument to measure patients satisfaction The satisfaction measurement instrument by Reisseer(1975) was referred to for the development of a tool to measure patient home care satisfaction. The instrument was an open-ended questionnaire which consisted of 11 domains; treatment, nursing care, information, time consumption, accessibility, rapidity, treatment skill, service relevance, attitude, satisfaction factors, dissatisfaction factors, overall satisfaction about nursing care, and others. In conclusion, Five evaluation instruments were developed for home care nursing. These were (1)standard for discharge with HCN referral. (2)instrument for measurement of health status, (3)instrument for measurement of self-care. (4)record for follow-up management, and (5)instrument to measure patient satisfaction. Also, the five instruments can be used to evaluate the effectiveness of the service to assure quality. Further research is needed to increase the reliability and validity of instrument through a community-based HCN evaluation.

  • PDF

Cardiac Intracoronary Stenting vs CABG: Prevention of Medical Accident (심장 스텐트 시술과 의료사고 예방)

  • Kim, Kyoung Reay;Park, Kook Yang
    • The Korean Society of Law and Medicine
    • /
    • v.18 no.2
    • /
    • pp.163-194
    • /
    • 2017
  • Coronary artery disease has increased in Korea as the country enters the aged society. It is well known that the incidence of coronary artery disease is related to aging, hypertension, diabetes, hyperlipidemia, and dietary habit. For effective treatment of significant coronary stenosis, close coordination between cardiac surgery and cardiology team is essential. Especially cardiologists' decision whether to do the stent placement or CABG is very important because the cardiologists usually start to consult the patients for their treatment. Recently, non-surgical interventions(that is stent placement) in cardiology field have dramatically increased as the national insurance system removed the limitation of the number of stents deployed. However, accidents are often caused by inappropriate use of stents, especially in patients with triple coronary disease or left main disease with heavy coronary calcifications. Another aspect of stent placement is to cope with an emergency case in the event of coronary rupture or pericardial tamponade during coronary interventions without cardiac surgeons. In the past two years, the Korea Consumer Agency (Consumer Dispute Coordination Committee) analyzed eight cases of medical dispute settlement. Only two hospitals were manned with both cardiologists and cardiac surgeons. Seven patients died of procedures of stenting and five patients died on the day of the procedure. Among the 8 cases, 5 cases showed 3 vessel disease and the rest of the cases had either severe calcification, complete occlusion or poor coronary antomies for stenting According to a 2017 national data registry of coronary stenting, less than 3 drug-eluting stents were implanted in 98% of all patients. In 2015, the number of stent procedures was 38,922, and approximately in 800 (2%) cases, more than four stents were used per patient. We emphasize that it is necessary to seriously consider the cost-benefit analysis between stent and CABG. The patient has the right to choose the right procedure by asking the liability of 'instruction explanation obligation'. He should be well informed of the pros and cons of both procedures to avoid overuse of stent. It can be solved by intimate discussion of individual cases with the cardiac surgeon and the patient. Unilateral dialogue with the patient, forceful restriction on the number of stenting, lack of surgeon's backup in difficult cases should all be avoided. It is also necessary to solve the problem not only at the hospital level, such as multidisciplinary integrated medical care, but also a nationwide solution such as expanding cardiac surgeons as essential personnel to public officials.

  • PDF

Estimation of fire Experiment Prediction by Utility Tunnels Fire Experiment and Simulation (지하공동구 화재 실험 및 시뮬레이션에 의한 화재 설칠 예측 평가)

  • 윤명오;고재선;박형주;박성은
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.23-33
    • /
    • 2001
  • The utility tunnels are the important facility as a mainstay of country because of the latest communication developments. However, the utilities tunnel is difficult to deal with in case of a fire accident. When a cable burns, the black smoke containing poisonous gas will be reduced. This black smoke goes into the tunnel, and makes it difficult to extinguish the fire. Therefore, when there was a fire in the utility tunnel, the central nerves of the country had been paralyzed, such as property damage, communication interruption, in addition to inconvenience for people. This paper is based on the fire occurred in the past, and reenacting the fire by making the real utilities tunnel model. The aim of this paper is the scientific analysis of the character image of the fire, and the verification of each fire protection system whether it works well after process of setting up a fire protection system in the utilities tunnel at a constant temperature. The fire experiment was equipped with the linear heat detector, the fire door, the connection water spray system and the ventilation system in the utilities tunnel. Fixed portion of an electric power supply cable was coated with a fire retardant coating, and a heating tube was covered with a fireproof. The result showed that the highest temperature was $932^{\circ}c$ and the linear heat detector was working at the constant temperature, and it pointed at the place of the fire on the receiving board, and Fixed portion of the electric power supply cable coated with the fire retardant coating did not work as the fireproof. The heating tube was covered with the fireproof about 30 minutes.

  • PDF