• Title/Summary/Keyword: acceptable limit

Search Result 260, Processing Time 0.024 seconds

RELIABILITY-BASED DESIGN OPTIMIZATION OF AUTOMOTIVE SUSPENSION SYSTEMS

  • Chun, H.H.;Kwon, S.J.;Tak, T.
    • International Journal of Automotive Technology
    • /
    • v.8 no.6
    • /
    • pp.713-722
    • /
    • 2007
  • Design variables for suspension systems cannot always be realized in the actual suspension systems due to tolerances in manufacturing and assembly processes. In order to deal with these tolerances, design variables associated with kinematic configuration and compliance characteristics of suspensions are treated as random variables. The reliability of a design target with respect to a design variable is defined as the probability that the design target is in the acceptable design range for all possible values of the design variable. To compute reliability, the limit state, which is the boundary between the acceptable and unacceptable design, is expressed mathematically by a limit state function with value greater than 0 for acceptable design, and less than 0 for unacceptable design. Through reliability analysis, the acceptable range of design variables that satisfy a reliability target is specified. Furthermore, through sensitivity analysis, a general procedure for optimization of the design target with respect to the design variables has been established.

A brief review on the standards of regulations and compensation in the environmental noise and vibration disputes resolution (환경소음.진동 피해 분쟁 조정을 위한 기준설정에 관한 소고)

  • Lee, Soo-Gab;Kim, Jae-Hwan;Kim, Kyu-Tae;Hong, Ji-Young;Eun, Hee-Joon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.876-878
    • /
    • 2008
  • The standards of acceptable limit and compensation is one of the most important things in environmental noise and vibration disputes resolution. In this paper, review on the present acceptable limit level and compensation standard in National Environmental Dispute Resolution Commission is introduced. Discordance of standards between in the regulation law and in the dispute resolution commission and it's improvement are discussed. Abnormal reasoning for compensation standards is pointed out from a author's private view.

  • PDF

Floor impact sound classification and setting Acceptable limit based on psychoacoustical evaluation (감성평가 기반 바닥충격음 등급화 및 수인한도 설정)

  • Kim, Sung Min;Hong, Joo Young;Jeon, Jin Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.7-9
    • /
    • 2014
  • An auditory experiment was conducted to establish annoyance criteria for floor impact noise in apartment buildings. Heavyweight floor impact sounds were recorded using an impact ball; the impact sound pressure level (SPL) together with the temporal decay rate (DR), which is quantified by the dB drop per second, was analyzed. For the experiment, A-weighted exposure levels of the heavy-weight floor impact sounds ranging 34~73 dB were evaluated at 3 dB intervals. Participants used a 7-point verbal scale to evaluate the level of annoyance from floor impact noise. The results show that the annoyance increases with increasing impact SPL and decreasing DR. Consequently, a classification and an acceptable level of floor impact sounds were proposed.

  • PDF

The acceptable limit of the contrast ratio of LCD TV based on human visual system

  • Shin, Kwang-Hoon;Moon, Jong-Won;Park, Sun-Ah;Ahn, Ji-Young;Kang, Dong-Woo;Shin, Hyun-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1497-1499
    • /
    • 2007
  • Visual perception experiments were conducted to determine the acceptable limit of the contrast ratio of LCD TV under the watching condition. The results showed that the corresponding contrast ratio should be below 10,000:1 at the 3H(height of screen) distance in the living room environment.

  • PDF

Development of A New Efficient Method for Controlling Robot Motion at and near Singularities (특이점 부근의 로봇운동을 효과적으로 제어하기 위한 새로운 방법 개발)

  • 정원지;최은재;홍대선;서영교;홍형표
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.11 no.6
    • /
    • pp.31-37
    • /
    • 2002
  • This paper presents a new motion control strategy for singularity avoidance in 6 DOF articulated robot manipulators, based on a speed limiting algorithm for joint positions and velocities. For a given task, the robot is controlled so that the joints move with acceptable velocities and positions within the reachable range of each joint by considering the velocity limit. This paper aims at the development of a new efficient method to control robot motion near and at singularities. The proposed method has focused on generating the optimal joint trajectory for a Cartesian end-effector path within the speed limit of each joint by using the speed limit avoidance as well as the acceleration/deceleration scheme. The proposed method was verified using MATLAB-based simulations.

Operation Plan of ESS for Increase of Acceptable Product of Renewable Energy to Power System (재생에너지의 전력계통 수용 증대를 위한 ESS 운영방안)

  • Kim, Yeong-Hwan;Myung, Ho-San;Kang, Nam-Ho;Lee, Chang-Woo;Kim, Min-Jae;Kim, Se-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.11
    • /
    • pp.1401-1407
    • /
    • 2018
  • This paper proposed a method of energy storage system (ESS) operation to increase acceptable production of renewable energy (RE). We analyzed the rebound effect that does not show a demand increase even if the capacity of the ESS is increased and considered the charging time by analyzing the time when the output limit is most generated. The rebound effect was mitigated by adjusting the discharging time of the ESS, and the effect of the increase of acceptable production of the renewable energy was analyzed by adjusting the charging time.

Assessment of Microbiological Quality of Cooked Dried-Seafoods in School Foodservice Operations (학교급식에서 제공되는 건포류 조리식품의 미생물적 품질평가)

  • Park, Heon-Guk;Ryu, Gyeong
    • Journal of the Korean Dietetic Association
    • /
    • v.12 no.2
    • /
    • pp.172-184
    • /
    • 2006
  • This study was aimed to provide safety management guidance by evaluating the microbial quality of cooked dried-seafoods in school foodservice operations. Nineteen seafood items were collected from six elementary schools, those were dried-anchovy, dried-seaweed and dried-fish, which were classified as cooking process. The temperatures at receiving and after cooking were measured and the analyses of cooking processes and microbial quality were performed. The temperatures of all foods after cooking were higher than the temperature limit of $74\^circC$. The number of total aerobic bacteria and S. aureus in dried-anchovy over the limit of $10^5$ and even the level of S. aureus was found to be unsatisfactory. The count of total aerobic bacteria was 2.1x$10^8$ CFU/g and the number of total aerobic bacteria after cooking was over the limit in one school. The level of E. coli (3.1x$10^3$ CFU/g) was over the limit at one school and the number of S. aureus (1.2×$10^4$ CFU/g) was considered as unacceptable. Dried- tangle and green laver were contaminated with total aerobic bacteria showing the over the limit. The numbers of total aerobic bacteria in dried- filefish, pollack and squid were 4.3x$10^6$, 3.4x$10^6$-3.9x$10^7$ and 4.6x$10^5$-4.1x$10^7$ CFU/g, respectively, which were in acceptable or unsatisfactory level. The E. coli in dried- filefish and pollack were over the limit. The total aerobic bacteria levels, 4.6x$10^5$-1.5x$10^6$ CFU/g in dried-pollack and 8.0x$10^5$-2.2x$10^7$ CFU/g in dried-squid, were over the limit after cooking except dried-filefish. The E. coli levels, 4.3x$10^3$ CFU/g in dried-filefish and 2.5x$10^2$ CFU/g in dried-pollack, were over the limit of $10^2$ CFU/g. The numbers of Enterobacteriaceae were either acceptable (3.3x$10^3$ CFU/g) or unsatisfactory (1.6x$10^4$ CFU/g) level in dried-pollack. S. aureus was unsatisfactory level (6.5x$10^4$ CFU/g) in dried-filefish while unacceptable in dried-pollack both before and after cooking. Unacceptable levels of S. aureus, 2.4x$10^4$ and 1.3x$10^5$ CFU/g were found from two schools, respectively. These results suggest that the contamination of raw materials and the seasonings added after cooking should be controlled to manage the microbial safety of cooked dried-seafoods.

  • PDF

The Study on Inverter DC Resistance Spot Welding Character & Mechanical Property of DP60 Steels (DP60강의 인버터 DC 저항 용접의 용접 특성 및 기계적 성질에 관한 연구)

  • Kim, In-Ju
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.12b
    • /
    • pp.604-606
    • /
    • 2011
  • Purpose This study analyzes resistance spot weldability of DP60 steels. Methodology To compare the resistance spot weldability of DP60 steels, tensile strength test and macro-section test were conducted for the resistance spot welds. Acceptable welding conditions were determined as a function of the resistance spot welding process parameters such as electrode force, welding time, and welding current. The lower limit of the welding lobe was the minimum shear tension strength for 590MPa-grade steel while the upper limit was determined whether or not expulsion was detected. Findings Welding force is 200kgf more appropriate in terms of 300kgf the larger the width of the welding zone. Acceptable welding current condition and welding lobe were changed depending on welding force. Research limitations This study is forced on inverter DC resistance spot weldability of 590Mpa-grade steels for automotive application. Practical implications This study confirms the weldability of DP60 steel by comparing resistance spot weldability depending on welding force. Originality This study analysed resistance spot weldability depending on welding force. wedability of DP60 steel were determined by welding lobes.

  • PDF

A Study on the Transformer Spare Capacity in the Existing Apartments for the Future Growth of Electric Vehicles (전기자동차 보급에 따른 기존 아파트의 변압기용량 한계시점에 대한 연구)

  • Choi, Jihun;Kim, Sung-Yul;Lee, Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.12
    • /
    • pp.1949-1957
    • /
    • 2016
  • Rapid Expansion of EVs(Electric Vehicles) is inevitable trends, to comply with eco-friendly energy paradigm according to Paris Agreement and to solve the environment problems such as global warming. In this paper, we analyze the limit point of transformer acceptable capacity as the increase of power demand considering EVs supply in the near future. Through the analysis of transformer utilization, we suggest methods to analyze the spare capacity of transformer for the case of optimal efficiency operation and emergency operation respectively. We have the results of 18.4~29% spare capacity for the charging infrastructure to the rated capacity of transformer by analyzing the existing sample apartments. It is analyzed that the acceptable number of EVs is 0.09~0.14 for optimal efficiency operation and 0.06~0.13 for emergency operation. Therefore, it is analyzed the power demand of EV will exceed the existing transformer spare capacity in 7~8 years as the annual growth rate of EVs is prospected 112.5% considering current annual growth rate of EVs and the government EV supply policy.

Development of Probability Computation Program for Standard Normal Distribution (표준정규분포의 확률계산 프로그램 개발)

  • 송서일
    • Journal of Korean Society for Quality Management
    • /
    • v.25 no.1
    • /
    • pp.182-192
    • /
    • 1997
  • The well-known standard normal distribution has been used within the limit of standard variable value of u=3.59. However, the probability values above the limit are not given in the literature. In this study, a probability computation program for standard normal distribution to u=5.99 with the proportional normal distribution a, pp.oximation suggested by Abramowitz and Stegun, Hastings is developed. The new standard normal distribution table developed by the program is presented and will be of help to estimate of probability values for testing and estimation of process mean value, lot acceptable probability, defective percentage of PPM unit of an out-of specification limit, process capability, test power of control charts, probability and statistics.

  • PDF