• 제목/요약/키워드: accelerated laboratory test

검색결과 104건 처리시간 0.024초

의약품 유통 관리용으로 사용되는 UHF 대역 RFID Tag의 가속수명시험법 개발 (Development of Accelerated Life Test Method for UHF RFID Tags for Medicine Supply Management)

  • 양일영;유상우;박정원;조원서
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제14권2호
    • /
    • pp.93-96
    • /
    • 2014
  • RFID (Radio Frequency IDentification) system is recognition technology which can maintain various object's information. Reliability of RFID tags is the most important factor in RFID system. In this paper, we proposed ALT (Accelerated Life Test) method for UHF RFID tags. Temperature and humidity were adopted as stress factors and the accelerated life tests were conducted in three different conditions. We performed failure analysis for identifying failure mechanism and statistical analysis of test data. In the statistical analysis, we employed Inverse Power law for relationship between tag's life and stress. Through the statistical analysis, we proposed acceleration factor for several levels of temperature-humidity. The reliability qualification test plans were also designed for the tag's target reliability.

0.5wt% 탄소강을 이용한 해안 야외부식시험과 염수분무시험, 가속부식시험의 가속계수에 대한 연구 (The Study on the Acceleration Factor of Coastal Outdoor Corrosion test, Salt Spray Test and Accelerated Corrosion Test using 0.5wt% carbon steel)

  • 조의열;권기봉;조대형;김종렬
    • Corrosion Science and Technology
    • /
    • 제12권5호
    • /
    • pp.209-214
    • /
    • 2013
  • In the industry, accelerated corrosion test is used for the life time prediction. When anti-corrosion test proceeds in real environments, it is difficult that we predict and evaluate the corrosion life time because of the long test time such as 10 years or more time. Accelerated corrosion test and Salt spray test are able to test corrosion life time of products in the laboratory instead of outdoor corrosion test. Experimental procedure is selected for the corrosion standard specimen, exposure of the specimens, measurements of the mass loss and evaluating the mass loss data. As a result, the acceleration factor of the accelerated corrosion test to the outdoor corrosion test is 414.8. Therefore we can predict the corrosion life time of carbon steel during a short time period.

야간투시경용 영상증폭관(KIT-7)의 가속수명시험에 관한 연구 (A STUDY ON THE ACCELERATED LIFE TESTS OF IMAGE INTENSIFIER ASSEMBLY(KIT-7))

  • 김성민;박정원;함중걸;김광연
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제7권3호
    • /
    • pp.127-136
    • /
    • 2007
  • The accelerated life tests(ALTs) and degradation characteristics of image intensifier assembly(KIT-7) under low illuminance and high temperature were investigated. The accelerated life tests were carried out at $5{\times}10^5\;fc-40^{\circ}C,\;10{\times}10^5\;fc-40^{\circ}C,\;5{\times}10^5\;fc-50^{\circ}C,\;10{\times}10^5\;fc-50^{\circ}C$ and relationship related to illuminance and temperature was used as an accelerated life test model. An ALTA program[6] was used to calculate an acceleration factor and the test of life distribution fit, and estimate three parameters of an life test model. To sum up, MTTF 10,000 h at $5{\times}10^{-5}\;fc-40^{\circ}C$ of image intensifier assembly was certificated.

  • PDF

유니버설조인트 시험방식을 이용한 치과용 임플란트의 피로시험 및 가속수명시험에 관한 연구 (Study on the Fatigue Test and the Accelerated Life Test for Dental Implant using Universal-Joint Test Type)

  • 도경훈;이석진;김종미;김성민
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제17권1호
    • /
    • pp.50-57
    • /
    • 2017
  • Purpose : This paper is a comparative analysis results of the fatigue test for dental implants and accelerated life test by using a static type loading device commonly used in Korea and a dynamic type loading device (universal-joint) recommended by FDA. Methods : Fatigue tests of dental implant is based on ISO 14801 and classified into static load test and dynamic load test. The tests were carried out on three test specimens by four load stress steps under each loading device. For analysis on failure mode such as crack, fracture and permanent deformation of test specimens, we used X-ray three-dimensional computed tomography on test specimens before and after the fatigue tests. The design of the accelerated life test was based on the analysis results of the fatigue life data obtained from the dynamic load test and the statistical analysis software (Minitab ver.15) was used to analyze the appropriate life distribution. Results : As a result of the fatigue tests and the accelerated life tests at same acceleration condition under each test method, the fatigue life under the dynamic type loading device (universal-joint) was shorter than when static type loading device was applied. Conclusion : This paper can be used as a reference when the universal-joint type loading device for implants fatigue test is applied as ISO 14801.

실내 가속부식시험을 통한 해양 강관합성 말뚝의 방식 기법 수명 평가 (Evaluation of Life Time for Anti-Corrosive Methods for Marine Steel Sheet by Cyclic Corrosion Test)

  • 박종원;이종구;이경황;김진홍;정문경;이주형
    • Corrosion Science and Technology
    • /
    • 제8권6호
    • /
    • pp.243-250
    • /
    • 2009
  • When a steel sheet pipe applied to marine environment, an anti-corrosive coating should be treated to obtain long-term life-time for steels, especially, splash zone. Although anti-corrosive property of coatings is required to be tested in real marine environment, it is difficult because of long test time such as 20 years or more time. Therefore, we used cyclic corrosion tester in a laboratory, which has similar conditions with salt-dry-wet process such as real marine environment. Anti-corrosive properties of the coatings and two steels were tested their anti-corrosive properties under cyclic corrosion test conditions(KS D ISO 14993) and the results were compared with estimate life-time in real marine environment. According to cyclic corrosion test, accelerated corrosive factor of each anti-corrosive coating was investigated accelerated corrosive factor from impedance with EIS method. Accelerated corrosive factor of type SS400 carbon steel and A690 was also investigated their accelerated corrosive factor from the regression curves of weigh loss results. One of the anti-corrosive coatings showed about 50 years life-time compared with standard sample life-time. Carbon steel SS400 showed from 0.1 mm/yr to 0.06 mm/yr as its corrosion rate.

가속내구성 조건에 따른 건축용 유기계 단열재의 단열성능 변화 (Changes in Insulation Performance of Organic Insulating Materials for Building Construction by Accelerated Durability Test Conditions)

  • 임순현;이건철
    • 한국건축시공학회지
    • /
    • 제16권6호
    • /
    • pp.595-601
    • /
    • 2016
  • 현재 건축구조물에 사용되는 단열재의 단열성능은 초기성능을 기준으로 설계 시에만 반영하고 있으며, 장기 내구성 저하에 따른 단열성능 감소는 반영되고 있지 않다. 본 연구에서는 가속내구성 시험을 통해 단열재의 내구성 저하에 따른 단열성능 저하를 검토하였다. 연구결과, 발포폴리스티렌 단열재 비드법의 경우 표준환경 조건 및 실험실 가속 시험 조건에서는 경시변화에 따른 성능저하가 나타나지 않았으나, 동결 융해 시험 조건에는 성능이 저하하는 것으로 나타났다. 반면, 압출법의 경우 동결 융해 시험 조건에서는 단열성능 저하가 작았지만, 경시변화 초기에 내부 가스의 방출로 급격한 성능저하를 나타내었다. 또한, 경질 폴리우레탄 폼 단열재의 경우 다른 단열재에 비해 초기 단열성능이 매우 뛰어났으나, 실험실 가속 시험조건 및 동결 융해 시험 조건에서는 성능이 다소 저하하는 것으로 나타났다.

접촉연소식 가스센서의 수명시험기준 개발 (Development of Life Test Specification for Catalytic Gas Sensor)

  • 강준구;박정원;황동훈;함중걸
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제6권1호
    • /
    • pp.37-50
    • /
    • 2006
  • The accelerated life tests of the catalytic gas sensor were performed at three different gas concentration conditions. From the test data, the power-Weibull model was estimated and the acceleration factor between test condition 25%LEL(Lowe Explosive Limit) and use condition 5%LEL was about 3 according to this acceleration model. Using this acceleration factor, life test specification for qualifying that B10 lifetime of the catalytic gas sensor meets the goal lifetime (5 years) was designed.

  • PDF

Corrosion Performance of Cu Bonded Grounding-Electrode by Accelerated Corrosion Test

  • Choi, Sun Kyu;Kim, Kyung Chul
    • Corrosion Science and Technology
    • /
    • 제17권5호
    • /
    • pp.211-217
    • /
    • 2018
  • Natural degradation of grounding-electrode in soil environment should be monitored for several decades to predict the lifetime of the grounding electrode for efficient application and management. However, long-term studies for such electrodes have many practical limitations. The conventional accelerated corrosion test is unsuitable for such studies because simulated soil corrosion process cannot represent the actual soil environment. A preliminary experiment of accelerated corrosion test was conducted using existing test standards. The accelerated corrosion test that reflects the actual soil environment has been developed to evaluate corrosion performances of grounding-electrodes in a short period. Several test conditions with different chamber temperatures and salt spray were used to imitate actual field conditions based on ASTM B162, ASTM B117, and ISO 14993 standards. Accelerated degradation specimens of copper-bonded electrodes were made by the facile method and their corrosion performances were investigated. Their corrosion rates were calculated to $0.042{\mu}m/day$, $0.316{\mu}m/day$, and $0.11{\mu}m/day$, respectively. These results indicate that accelerated deterioration of grounding materials can be determined in a short period by using cyclic test condition with salt spray temperature of $50^{\circ}C$.

차수형 케이블의 수트리 가속실험후 와이블분포 해석 (The Analysis of Weibull Distribution after an Accelerated Aging Test of MV Cable)

  • 김진국;임장섭;송일관;이재봉
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.178-181
    • /
    • 2003
  • For many years, testing laboratories, research institutes and manufactures try to find a reliable water tree accelerated ageing test that is able to show whether a polymer Medium Voltage cable os susceptible to water treeing or not. Test on laboratory samples, model cable designs, and fell size cable are presented Apart form aging, another important aspect of any accelerated aging test is the right choice of th preconditioning method. This paper is the analysis of weibull distribution method after an accelerated aging test of MV(Medium Voltage) cable.

  • PDF

배전케이블의 수트리 가속열화 후 와이블분포 해석 (The Analysis of Weibull Distribution after an Accelerated Aging Test of MV Cable)

  • 김진국;임장섭;송일근;김주용;이우선
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 제5회 영호남 학술대회 논문집
    • /
    • pp.7-11
    • /
    • 2003
  • for many years already, testing laboratories, research institutes and manufactures try to find a reliable water tree accelerated ageing test that is able to show whether a polymer Medium Voltage cable os susceptible to water treeing or not. Test on laboratory samples, model cable designs, and fell size cable are presented. Apart form aging, another important aspect of any accelerated aging test is the right choice of th preconditioning method. THTS paper is the analysis of weibull distribution method after an accelerated aging test of MV(Medium Cable) cable.

  • PDF