• Title/Summary/Keyword: ac ground

Search Result 146, Processing Time 0.027 seconds

A Novel Soft Switching PWM·PFC AC·DC Boost Converter

  • Sahin, Yakup
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.256-262
    • /
    • 2018
  • This study introduces a novel Soft Switching (SS) Pulse Width Modulated (PWM) AC-DC boost converter. In the proposed converter, the main switch is turned on with Zero Voltage Transition (ZVT) and turned off with Zero Current Transition (ZCT). The main diode is turned on with Zero Voltage Switching (ZVS) and turned off with Zero Current Switching (ZCS). The auxiliary switch is turned on and off with ZCS. All auxiliary semiconductor devices are turned on and off with SS. There is no extra current or voltage stress on the main semiconductor devices. The majority of switching energies are transferred to the output by auxiliary transformer. Thus, the current stress of auxiliary switch is significantly reduced. Besides, the proposed converter has simple structure and ease of control due to common ground. The theoretical analysis of the proposed converter is verified by a prototype with 100 kHz switching frequency and 500 W output power. Furthermore, the efficiency of the proposed converter is 98.9% at nominal output power.

Enhanced Voltage Gain Single-Phase Current-Fed qZ-Source Inverter (전압 이득이 향상된 단상 전류형 qZ-소스 인버터)

  • Shin, Hyun-Hak;Cha, Hon-Nyong;Kim, Heung-Geun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.305-311
    • /
    • 2013
  • This paper proposes a performance improvement of existing single-phase current-fed qZ-Source inverter. Voltage gain of the traditional voltage-fed full-bridge inverter and single-phase current-fed qZ-source inverter is only equal to or smaller than input voltage. The proposed inverter can obtain twice higher voltage gain than the single-phase current-fed qZ-Source inverter by adding an extra switch and a capacitor in the circuit. In addition, the proposed inverter shares the common ground between dc input and ac output voltage. Therefore, the proposed inverter can eliminate the possible ground leakage current problem when it is used for grid-tied photovoltaic inverter system. A 120 W prototype inverter is built and tested to verify performances of the proposed inverter.

Dynamic Voltage Compensator using Series and Shunt Inverters (직.병렬 인버터를 이용한 동적전압보상기)

  • Park, Deok-Hui;Lee, Jun-Gi;Han, Byeong-Mun;So, Yong-Cheol;Kim, Hyeon-U
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.11
    • /
    • pp.655-662
    • /
    • 1999
  • This paper describes controller design and simulation-model development of a dynamic voltage compensator using series and shunt inverters. The control system was designed using PI controller and vector relationship between the supply voltage and load voltage. A simulation model with EMTP was developed to analyze performance of the controller and the whole system. The simulation and experiment results confirm that the dynamic compensator can restore the load voltage under the fault of the distribution system, such as single-line-ground fault, three-line-to-ground fault, and line-to-line fault.

  • PDF

A Numerical Analysis on Stability Analysis of Cavity Ground considering Pavement Thickness and Traffic Load (포장층 두께와 교통하중 크기를 고려한 공동 발생 지반의 안정성 분석에 관한 수치해석)

  • You, Seung-Kyong;Ahn, Heechul;Kim, Young-Ho;Han, Jung-Geun;Hong, Gigwon;Park, Jeong-Jun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.4
    • /
    • pp.287-297
    • /
    • 2019
  • In this study, a series of finite element numerical analyzes were performed considering the pavement thickness and traffic load for the purpose of stability analysis on the cavity ground. In order to verify the validity of this numerical method, the previous numerical analysis was used to simulate the mechanical behavior of cavity ground, and the results were compared and analyzed. Also, from the numerical results, it was possible to confirm the dynamic behavior of the ground by confirming the change of ground void ratio, surface settlement, and shear stress, and using the relationship between stress ratio, non-destructive depth and surface settlement, the safety of the was analyzed. As a result, as the pavement thickness decreased and the traffic load increased, the non-destructive depth and the overall stability of the ground decreased with the increase of surface settlement.

PCB Plane Model Including Frequency-Dependent Losses for Generic Circuit Simulators (범용 회로 시뮬레이터를 위한 손실을 반영한 PCB 평판 모형)

  • Baek, Jong-Humn;Jeong, Yong-Jin;Kim, Seok-Yoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.6
    • /
    • pp.91-98
    • /
    • 2004
  • This paper proposes a PCB plane model for generic SPICE circuit simulators. The proposed model reflects two frequency-dependent losses, namely skin and dielectric losses. After power/ground plane pair is divided into arrays of unit-cells, each unit-cell is modeled using a transmission line and two loss models. The loss model is composed of a resistor for DC loss, series HL ladder circuit for skin loss and series RC ladder circuit for dielectric loss. To verify the validity of the proposed model, it is compared with SPICE ac analysis using frequency-dependent resistors. Also, we show that the estimation results using the proposed model have a good correlation with that of VNA measurement for the typical PCB stack-up structure of general desktop PCs. With the proposed model, not only ac analysis but also transient analysis can be easily done for circuits including various non-linear/linear devices since the model consists of passive elements onl.

Analysis of Risk Voltage for Grounding Electrode by Injection of Earth Leakage Current

  • Gil, Hyoung-Jun;Kim, Dong-Woo;Kim, Dong-Ook;Lee, Ki-Yeon;Moon, Hyun-Wook;Kim, Hyang-Kon;Kil, Gyung-Suk
    • International Journal of Safety
    • /
    • v.8 no.2
    • /
    • pp.9-14
    • /
    • 2009
  • This paper describes analysis of risk voltage for grounding electrode where earth leakage current is injected. To assess risk voltage of grounding electrode, the grounding simulator and CDEGS program were used to obtain measured data and theoretical results of this study. The grounding simulator was composed of a hemispherical water tank, AC power supply, a movable potentiometer, and test grounding electrodes. The shapes of grounding electrode model was ground rod. The potential rise was measured by grounding simulator, and the touch and step voltages were computed by CDEGS program. As a consequence, the potential rise of ground rod abruptly decreases with increasing the distance from the grounding electrode to the point to be tested. The touch voltage above the ground rod was low, but the step voltage was high. The measured results were compared with the computer calculated data and were known in good agreement.

Study of Engine Control/Performance Modeling for Helicopter Simulator (헬리콥터 시뮬레이터용 엔진 제어 및 성능 모델링 기법 연구)

  • Jun, Hyang-Sig;Jeon, Dae-Keun;Choi, Hyoung-Sik;Choi, Young-Kiu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.10a
    • /
    • pp.183-188
    • /
    • 2008
  • Engine control/performance model for helicopter simulator is one of the most important models which affect flight performance and handling quality. It is typical to develop the model based on the raw data and models from the engine designers/manufacturers. The approaches in this study were to develop the basic model based on the available resources and to tune and verify it based on the ground/flight test results. The maintenance manuals of TB3-117 which is installed in KA-32T were reviewed and the components to be simulated for the engine control model were categorized and modeled. Piece-wise linear modeling method was used for the engine performance model. The engine performance data in the engine maintenance manuals were incorporated into the engine steady state performance tables, which were incorporated with the transfer functions for the dynamic performance. Engine control/performance model was compared and tuned with the ground/flight test results. It was verified that the fidelity of the model was within the tolerances in FAA AC120-63.

  • PDF

Factors Influencing Field Monitoring of the Oriental Fruit Moth, Grapholita molesta, with Sex Pheromone (성페로몬을 이용한 복숭아순나방(Grapholita molesta) 모니터링에 영향을 주는 요인)

  • Kim, Yong-Gyun;Jung, Sung-Chae;Bae, Sung-Woo;Kwon, Bo-Won;Yoon, Hyang-Mi;Hong, Yong-Pyo
    • Korean journal of applied entomology
    • /
    • v.46 no.3
    • /
    • pp.349-356
    • /
    • 2007
  • Three active components (Z8-12:Ac, E8-12:Ac, and Z8-12:OH) are known in sex pheromone of the oriental fruit moth, Grapholita molesta, and have been commercially available to apply for population monitoring and mating disruption. However, there have been variation among commercial products in pheromone composition and amount impregnated in each pheromone releaser. This study was performed to optimize factors influencing on pheromone monitoring of G. molesta by analyzing pheromone composition/amount, effective period of releaser, and trap type/placement in apple trees. High purity of Z8-12:Ac component was effective to attract males, in which 96% or more of cis acetate isomer component appeared to be optimal composition. Pheromone amounts ($0.01-1\;{\mu}g$) impregnated in each rubber dispenser did not give significant effect on monitoring during 90 days from June to August. "Delta" trap was much more efficient than "cone" trap to collect males. Trap installation was another factor, in which placing traps at canopy level was much efficient than at trunk or ground levels. Pheromone trap monitoring with these optimal factors indicated three to four adult peaks from June to September in addition to high overwintering population from April to May in pesticide-applied orchards in Andong, Korea.

Fabrication of the Optical Fiber-Photodiode Array Module Using Si v-groove (실리콘 v-groove를 이용한 광섬유-광검출기 어레이 모듈 제작)

  • 정종민;지윤규;박찬용;유지범;박경현;김홍만
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.6
    • /
    • pp.88-97
    • /
    • 1994
  • We describe the design, fabrication, and performance of the optical fiber-photodiode 1$\times$12 arry module using mesa-type InS10.53T GaS10.47TAS/INP 1$\times$12 PIN photodiode array. We fabricated the PIN PD array for high-speed optical fiber parallel data link optimizing quantum efficiency, operating speed sensitivity from the PIN-FET structure, and electrical AC crosstalk. For each element of the array, the diameter of the photodetective area is 80 $\mu$m, the diameter of the p-metal pad is 90 $\mu$m, and the photodiode seperation is 250 $\mu$m to use Si v-groove. Ground conductor line is placed around diodes and p-metal pads are formed in zigzag to reduce Ac capacitance coupling between array elements. The dark current (IS1dT) is I nA and the capacitance(CS1pDT) is 0.9 pF at -5 V. No signifcant variations of IS1dT and CPD from element to element in the array were observed. We calulated the coupling efficiency for 10/125 SMF and 50/125 GI MMF, and measured the responsivity of the PD array at the wavelength is 1.55 $\mu$ m. Responsivities are 0.93 A/W for SMF and 0.96 A/W for MMF. The optical fiber-PD array module is useful in numerous high speed digital and analog photonic system applications.

  • PDF