• 제목/요약/키워드: abutment connection type

검색결과 70건 처리시간 0.033초

임플랜트 고정체-지대주 연결부의 형태와 직경이 임플랜트의 기계적 실패에 미치는 영향 (Effect of morphology and diameter of implant fixture-abutment connection on mechanical failure of implants)

  • 윤보혁;신현모;윤미정;허중보;정창모;강은숙
    • 대한치과의사협회지
    • /
    • 제53권9호
    • /
    • pp.644-655
    • /
    • 2015
  • Purpose: This study was conducted to evaluate the effect of the fixture abutment connection type and diameter on the screw joint stability in external butt joint for 2nd surgery and internal cone connected type implant system for 1st and 2nd surgery using ultimate fracture strength. Materials and Methods: USII system, SSII system and GSII system of Osstem Implant were used. Each system used the fixture with two different diameters and cement-retained abutments, and tungsten carbide / carbon coated abutment screws were used. Disc shaped stainless steel metal tube was attached using resin-based temporary cement. The experimental group was divided into seven subgroups, including the platform switching shaped specimen that uses a regular abutment in the fixture with a wide diameter in USII system. A static load was increased to the metal tube at 5mm deviated point from the implant central axis until it reached the compression bending strength at a rate of 1mm/min. Then the deformations and patterns of fracture in threaded connection were compared. Results and Conclusion: 1. In the comparison between the Regular diameter, compression bending strength of SSII system was higher than USII system and GSII system. There was no significant difference between USII system and GSII system. 2. In the comparison between wide diameter, compression bending strength was increased in the order of GSII system, USII system, and SSII system. 3. In comparison between the implant diameter, compression bending strength of the wide diameter was greater than the regular diameter in any system(P<0.05). 4. There was no significant difference between the platform switching (III group) and the regular diameter (I group) in USII system. 5. In USII system, fracture of abutment screw and deformation of both fixture and abutment were observed in I, II and III subgroups. 6. Failure pattern of SSII system, which was the fracture of abutment screw and deformation of the abutment and fixture, was observed in both IV and V subgroups. Fracture of some fixtures was observed in subgroup V. 7. Failure pattern of GSII system, which was the fracture of the abutment screw and deformation of the fixture and the abutment, was observed in both VI and VII subgroups. Apart from other subgroups, subgroup VII demonstrated no bending neither the fracture at the top of the fixture. The compressive deformation of internal slope in the fixture was the only thing observed in subgroup VII.

PS 강봉으로 일체화된 강합성 라멘교의 거더-교대 접합부에 대한 피로 성능 평가 (Fatigue Capacity Evaluation of the Girder-Abutment Connection for the Steel-Concrete Composite Rigid-Frame Bridge Integrated with PS Bar)

  • 안영수;오민호;정지승;이상윤
    • 콘크리트학회논문집
    • /
    • 제24권3호
    • /
    • pp.249-258
    • /
    • 2012
  • 교대 일체식 교량과 강합성 라멘교는 유지보수의 주된 원인이 되는 신축이음 및 받침이 생략되어 유지관리 및 구조적인 장점을 얻을 수 있는 교량 형식이다. 하지만, 통상적으로 거더를 교대에 매립하는 형태로 시공되는 접합부는 시공상세가 복잡하고 접합부의 시공상세를 간략화하여 시공효율을 향상시킨 새로운 교량 형식을 제안하였다. 제안된 형식의 교량은 PS 강봉에 긴장력을 도입하여 강재로 제작된 거더와 교대를 일체화하는 형태의 교량이다. 이 연구에서는 PS 강봉으로 일체화된 접합부의 피로 성능을 평가하기 위하여 접합부에 대한 유한요소해석 및 피로실험을 실시하였다. 유한요소해석 결과, 제안된 교량의 접합부는 기본적으로 피로에 의한 손상의 가능성이 매우 낮은 것으로 나타났으며, 피로시험 결과로부터 2,000,000회의 피로반복하중이 재하된 상태에서도 접합부의 일체화 성능을 유지하고 있는 것을 확인할 수 있었다.

A comparative study of gold UCLA-type and CAD/CAM titanium implant abutments

  • Park, Ji-Man;Lee, Jai-Bong;Heo, Seong-Joo;Park, Eun-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권1호
    • /
    • pp.46-52
    • /
    • 2014
  • PURPOSE. The aim of this study was to evaluate the interface accuracy of computer-assisted designed and manufactured (CAD/CAM) titanium abutments and implant fixture compared to gold-cast UCLA abutments. MATERIALS AND METHODS. An external connection implant system (Mark III, n=10) and an internal connection implant system (Replace Select, n=10) were used, 5 of each group were connected to milled titanium abutment and the rest were connected to the gold-cast UCLA abutments. The implant fixture and abutment were tightened to torque of 35 Ncm using a digital torque gauge, and initial detorque values were measured 10 minutes after tightening. To mimic the mastication, a cyclic loading was applied at 14 Hz for one million cycles, with the stress amplitude range being within 0 N to 100 N. After the cyclic loading, detorque values were measured again. The fixture-abutment gaps were measured under a microscope and recorded with an accuracy of ${\pm}0.1{\mu}m$ at 50 points. RESULTS. Initial detorque values of milled abutment were significantly higher than those of cast abutment (P<.05). Detorque values after one million dynamic cyclic loadings were not significantly different (P>.05). After cyclic loading, detorque values of cast abutment increased, but those of milled abutment decreased (P<.05). There was no significant difference of gap dimension between the milled abutment group and the cast abutment group after cyclic loading. CONCLUSION. In conclusion, CAD/CAM milled titanium abutment can be fabricated with sufficient accuracy to permit screw joint stability between abutment and fixture comparable to that of the traditional gold cast UCLA abutment.

Comparison of implant component fractures in external and internal type: A 12-year retrospective study

  • Yi, Yuseung;Koak, Jai-Young;Kim, Seong-Kyun;Lee, Shin-Jae;Heo, Seong-Joo
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권2호
    • /
    • pp.155-162
    • /
    • 2018
  • PURPOSE. The aim of this study was to compare the fracture of implant component behavior of external and internal type of implants to suggest directions for successful implant treatment. MATERIALS AND METHODS. Data were collected from the clinical records of all patients who received WARANTEC implants at Seoul National University Dental Hospital from February 2002 to January 2014 for 12 years. Total number of implants was 1,289 and an average of 3.2 implants was installed per patient. Information about abutment connection type, implant locations, platform sizes was collected with presence of implant component fractures and their managements. SPSS statistics software (version 24.0, IBM) was used for the statistical analysis. RESULTS. Overall fracture was significantly more frequent in internal type. The most frequently fractured component was abutment in internal type implants, and screw fracture occurred most frequently in external type. Analyzing by fractured components, screw fracture was the most frequent in the maxillary anterior region and the most abutment fracture occurred in the maxillary posterior region and screw fractures occurred more frequently in NP (narrow platform) and abutment fractures occurred more frequently in RP (regular platform). CONCLUSION. In external type, screw fracture occurred most frequently, especially in the maxillary anterior region, and in internal type, abutment fracture occurred frequently in the posterior region. placement of an external type implant rather than an internal type is recommended for the posterior region where abutment fractures frequently occur.

국산 내부연결형 임플란트시스템(GS II$^{(R)}$)에서 지대주 연결방식에 따른 응력분석에 관한 연구 (Three-Dimensional Finite Element Analysis of Internal Connection Implant System (Gsii$^{(R)}$) According to Three Different Abutments and Prosthetic Design)

  • 장미라;곽주희;김명래;박은진;박지만;김선종
    • 구강회복응용과학지
    • /
    • 제26권2호
    • /
    • pp.179-195
    • /
    • 2010
  • 임플란트 보철물에 저작력 등 외부 하중이 작용하면 내부 반응으로 응력이 발생되는데 지지골에 나타난 응력은 골재생 및 흡수 파괴, 임플란트에 나타난 응력은 임플란트 자체의 파절이나 나사의 풀림현상 및 파절, 상부 구조물에 나타난 응력은 보철물의 파절 등을 예견하는 지침이 될 수 있을 것이다. 지대주의 형상과 재질에 따라 연결방법과 보철방법이 달라지고 임플란트 내부의 하중전달 기전이 변하게 되고 이에 따라 악골에 발생하는 응력분포 역시 달라질 수 있다. 본 연구에서는 하악 제 1대구치 부위에 이중나사 구조를 갖고 원추형 내측연결 임플란트 시스템인 GSII$^{(R)}$ (Osstem, Korea)임플란트를 이용해 지대주의 종류를 티타늄 소재의 2-piece Transfer$^{TM}$ abutment (GST), 금합금 소재의 2-piece GoldCast$^{TM}$ abutment(GSG), 외부 연결형태를 가진 3-piece Convertible$^{TM}$ abutment (GSC) 로 분류하여 이에 따른 응력분포 양상을 비교 분석하여 보았다. 결과 하중조건에 관계없이 응력은 주로 지대주와 고정체가 접촉하는 경부에 집중되었다. 또한 하중조건에 관계없이 임플란트의 고정체 상부와 접촉하는 치밀골에 높은 응력이 나타나고 해면골에는 아주 작은 응력이 나타났다. 축하중보다는 중심축을 벗어난 하중조건에서 더 높은 응력이 발생되었고 수직하중보다 경사하중에서 더 높은 응력이 발생되었다. 전체에 걸친 최대응력은 GSG에서는 지대주, 치관 및 고정체에 고르게 분포되었고 GST는 주로 고정체와 지대주 나사에, GSC는 고정체와 지대주에 집중되었다. 세 지대주 간 골내의 최대응력에는 유의한 차이가 없었고 GSG가 전체 구성부의 응력분포에 있어 유리한 것으로 나타났다.

일체 구조형식 교량의 설계 및 시공기법 연구 (Design and Construction of Integral Abutment Bridge)

  • 이성우;나정우;조남훈
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1996년도 가을 학술발표회 논문집
    • /
    • pp.121-128
    • /
    • 1996
  • In this study design and construction technique for joint-less integral abutment for short to mid span bridges was developed. Expansion of superstructure due to thermal effect was absorbed in the flexible pile-type abutment in stead of expansion joint in the conventional bridges. Design method for pile subject to vertical and horizontal force was proposed. Backfill, approach slab and details of its connection joint with pavement was also proposed.

  • PDF

PS 강봉으로 일체화된 강합성 라멘교의 개발을 위한 실험연구 (Experimental Study for Development of the Steel-Concrete Composite Rigid-Frame Bridge Integrated with PS Bar)

  • 안영수;정지승
    • 한국안전학회지
    • /
    • 제27권4호
    • /
    • pp.50-61
    • /
    • 2012
  • In recent years, various research and developments to introduce composite bridges of new concept have been performed. The types of integral bridge and portal rigid frame bridge are having advantages in bridge maintenance and structural efficiency by eliminating expansion joints and bridge supports. However, the detail of typical girder-abutment connection has problems such as complexity of construction and increase of the construction cost. A new type of bridge, called prestress integral composite girder(PIC girder) bridge, is proposed in this study, which decreases the cost of construction and improves the efficiency of construction by simplifying the detail of construction for girder-abutment connection. PIC girder bridge has the connection detail in which the steel girder and the abutment are integrated by using the PS bar installed in the connection. In this study, finite element analysis and mock-up load test are conducted to evaluate the propriety of design, the effective of fabrication and structural safety for PIC girder bridge. The adequacy of the PIC giredr bridge is verified by the results of static/dynamic load test and finite element analyses.

원추형 연결 임플란트에서 지대주 종류에 따른 나사풀림과 침하현상에 관한 연구 (Effect of various abutment systems on the removal torque and the abutment settling in the conical connection implant systems)

  • 이진선;이준석
    • 대한치과보철학회지
    • /
    • 제50권2호
    • /
    • pp.92-98
    • /
    • 2012
  • 연구 목적: 본 연구 목적은 서로 다른 재료로 제작된 지대주를 이용하여 동적하중을 가했을 때 풀림토크와 침하량에 대한 임플란트-지대주 연결부의 안정성에 대하여 알아보는 것이다. 연구 재료 및 방법: 원추형 내부연결 구조를 갖는 임플란트에 이용되는 세 가지 지대주, 티타늄 합금 지대주(Cement abutment, Osstem Co., Seoul, Korea), 귀금속 UCLA 지대주(UCLA Goldcast abutment, Osstem Co., Seoul, Korea), 비귀금속 UCLA 지대주(CCM Metalcast abutment, 3M ESPE, Seefeld, Germany)를 사용하였다. 귀금속 UCLA 지대주와 비귀금속 UCLA 지대주를 티타늄 지대주와 유사한 형태로 납형을 형성 한 후 각각 제 3형 금합금(E-3, Heesung catalyst Co., Seoul, Korea)와 니켈-크롬 합금인(Rexillium $III^{(R)}$, $Pentron^{(R)}$, San Diego, USA)를 사용하여 주조 하였다. 임플란트와 지대주를 디지털 토크 컨트롤러를 이용하여 30 N cm로 체결하였고 전하중 상실을 보상하기 위하여 10분 후 다시 같은 힘으로 체결 하였다. 디지털 토크 게이지를 사용하여 풀림토크를 측정하였고 디지털 마이크로미터를 이용하여 임플란트/지대주 길이를 측정하였다. 그 후 동적 하중 피로 시험기에 지대주를 장착한 후 최대 250 N, 최소 25 N, 주기 14 HZ의 sine형의 하중을 장축과 평행하게 가하였다. 하중 후 임플란트/지대주의 길이를 재측정 하고, 전후 길이변화량을 이용하여 침하량을 계산하였으며 풀림토크를 측정하였다. 결과: 하중 전후의 길이를 비교하였을 때 세 군 모두에서 유의한 차이를 보였다($P$<.05). 군 간의 침하량을 비교하였을 때 통계적으로 유의한 차이를 보이지는 않았다. 하중 전후의 풀림토크를 비교하였을 때 역시 세 군 모두에서 유의한 차이를 보이며 감소하였다 ($P$<.05). 하중 전 풀림토크와 하중 후 풀림토크를 군간 비교하였을 경우에는 통계적으로 유의한 차이를 보이지는 않았다. 결론: 원추형 내부 연결구조를 갖는 임플란트에서 동적하중은 임플란트의 침하량과 풀림토크에 영향을 미치는 것으로 보이나 지대주간 차이는 나타나지 않았다. 비귀금속UCLA 지대주이 사용은 귀금속 UCLA 지대주와 마찬가지로 기능적 하중에서 안정적일 것으로 사료된다.

내부연결 임플란트용 타이타늄 소켓을 이용한 지르코니아 지대주에서 열순환이 나사풀림에 미치는 영향: 예비연구 (The effect of a titanium socket with a zirconia abutment on screw loosening after thermocycling in an internally connected implant: a preliminary study)

  • 경규영;차현석;이주희
    • 구강회복응용과학지
    • /
    • 제33권2호
    • /
    • pp.114-118
    • /
    • 2017
  • 목적: 이 연구의 목적은 타이타늄 구성요소를 가진 지르코니아 지대주가 내부연결 임플란트에 사용되었을 때 나사 풀림에 대해 알아보는 것이다. 열순환 후 타이타늄 소켓을 가진 지르코니아 지대주와 타이타늄 지대주의 나사 풀림과 제거력을 비교 분석하였다. 연구 재료 및 방법: 내측연결 임플란트와 내측연결 타이타늄 지대주, 타이타늄 소켓을 가진 외측연결 지르코니아 지대주를 준비하였다. 내부연결형 임플란트에 5개의 타이타늄 지대주를(대조군), 타이타늄 소켓을 가진 5개의 지르코니아 지대주(실험군)를 각각 연결하고 30 Ncm의 토크로 조인 후 열순환 처리 전후의 지대주 나사 제거력을 측정하였다. 각 시편들은 열순환 장치의 수조에서 $5^{\circ}C$$55^{\circ}C$의 물에 60초씩 교대로 2,000회의 열순환을 시행하였다. 각 시편의 나사 풀림을 조사하고 열순환 전후에 나사 제거력을 통계학적으로 분석하였다. 결과: 두 그룹 모두에서 열순환 후 지대주 나사 풀림을 보이지 않았다. 열순환 전후의 나사 제거력 차이는 대조군에서 $-1.34{\pm}2.53Ncm$, 실험군에서 $-1.26{\pm}2.06Ncm$ 로 나타났다. 독립표본 T 통계분석 결과 두 군간에 유의한 차이를 보이지 않았다(P > 0.05). 결론: 이 실험의 결과 내에서 내부연결 임플란트를 위한 지르코니아 지대주 내 타이타늄 소켓이 열순환 후 지대주 나사풀림에 타이타늄 지대주와 비교하여 유의한 영향을 나타내지 않았다.

임플란트 연결부의 개념과 적용: Part 2. 안착형 외부 및 내부 연결형 임플란트의 식립과 보철 (Concept and application of implant connection systems: Part II. Placement and restoration of external connection implant and tissue level implant)

  • 고경호;강현구;허윤혁;박찬진;조리라
    • 구강회복응용과학지
    • /
    • 제36권4호
    • /
    • pp.222-231
    • /
    • 2020
  • 안착형 외부 연결 임플란트를 적절히 사용하기 위해서는 식립 시에 임플란트 간의 간격에 주의해야 하며 2차 수술 시에 임플란트 상부로 올라간 골을 다듬어야 한다. 육각형태를 가진 지대주가 원형 지대주에 비해 유용하다. 외부 연결형 임플란트는 악간간격이 제한된 경우에 적용할 수 있다. 안착형 외부연결(조직수준) 임플란트는 상부 직경의 두께로 인한 생역학적 장점과 내재된 점막관통부로 인한 생물학적 장점을 가지고 있다. 조직수준 임플란트를 수복할 때 지대주 수준과 임플란트 수준의 변연 중 악간공간에 따라 선택한다. 어떤 한 가지 임플란트 종류로는 모든 증례를 만족시키기 어려우므로 교합력 및 골조건을 고려하여 적절한 임플란트를 선택하는 것이 필요하다.