• 제목/요약/키워드: absorption power

검색결과 849건 처리시간 0.026초

ChlorophyII and suspended sediment specific absorption coefficient in the sea.

  • Ahn, Yu-Hwan;Moon, Jeong-Eon
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 1998년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.399-403
    • /
    • 1998
  • Absorption coefficient per mass unit of particles, specific absorption coefficient, is one of main parameters in developing algorithms for ocean color remote sensing. Specific absorption coefficient of chlorophyll (a$^*_{ph}$) and suspended sediment (SS) were analyzed by "wet filter technique" and "Kishino method" for data sets observed in the Yellow and Mediterranean Seas. A new data-recovering method for the filter technique was also developed using spectrum slopes. This method recovered the baseline of spectrum that was often missed in the Kishino method. High a$^*_{ph}$($\lambda$) values in the oligotrophic Mediterranean Sea and low values in the Yellow Sea were observed, spanning over the range of 0.02 to 0.12 $m^2$/mg, at the chlorophyll maximum absorption wavelength 440nm. The empirical relationship between a$^*_{ph}$ and chlorophyll concentration was found to fit a power function, which was slightly different from that proposed by Bricaud et ai. (1995). Absorption specific coefficients for suspended sediment (a$^*_{SS}$) didn't show any relationship with concentrations of suspended sediment. However, the average value of a$^*_{SS}$ at 440nm was close to the specific absorption coefficient of soil (loess) measured by Ahn (1990). The more-pronounced variability of a$^*_{SS}$ than a$^*_{ph}$ perhaps can explain more wide range of size-distribution for SS, which were determined by their specific gravity and agitation of water mass in the sea surface.

  • PDF

Performance Prediction & Analysis of MGT Co-generation System

  • Hur, Kwang-Beom;Park, Jung-Keuk;Rhim, Sang-Kyu;Kim, Jae-Hoon
    • 신재생에너지
    • /
    • 제2권3호
    • /
    • pp.15-22
    • /
    • 2006
  • As the distributed generation becomes more reliable and economically feasible, it is expected that a higher application of the distributed generation units would be interconnected to the existing grids. This new market penetration using the distributed generation technology is linked to a large number of factors like economics and performance, safety and reliability, market regulations, environmental issues, or grid connection standards. KEPCO, a government company in Korea, has performed the project to identify and evaluate the performance of Micro Gas Turbine(MGT) technologies focused on 30, 60kW-class grid-connected optimization and combined Heat & Power performance. This paper describes the results for the mechanical, electrical, and environmental tests of MGT on actual grid-connection under Korean regulations. As one of the achievements, the simulation model of Exhaust-gas Absorption Chiller was developed, so that it will be able to analyze or propose new distributed generation system using MGT. In addition, KEPCO carried out the field testing of the MGT Cogeneration system at the R&D Center Building, KEPCO. The field test was conducted in order to respond to a wide variety of needs for heat recovery and utilization. The suggested method and experience for the evaluation of the distributed generation will be used for the introduction of other distributed generation technologies into the grid in the future.

  • PDF

헬리콘 플라즈마에서 이온 펌핑 효과의 영향에 대한 수치적 해석 연구 (Numerical studied on consequenses of the ion pumping effect in helicon plasmas)

  • 조수원;박인호;최성을;권명회
    • 한국진공학회지
    • /
    • 제8권3B호
    • /
    • pp.353-360
    • /
    • 1999
  • The global balance model is applied to investigate the transient behavior of the electron density and temperature in helicon plasmas. The power absorption calculated from the solutions of the Maxwell equations is used in solving the power balance equation. A balance model for the neutral gas is also considered to fins its density self-consistently. It is turned out that the numerical results reasonably explain consequences of the ion pumping effect including the occurrence of two distinct modes of pulsed helicon discharge which have been observed experimentally. The behavior of the discharge parameters are fond to be primarily dependent on the power absorption and the gas flow rate, but the pressure controls the electron density and temperature of the final steady state as well as the transient state even with the same flow rate. Finally, it is shown that the electron density virtually the linear relationship between the density and the magnetic field is retained for a higher pressure when the effect of the ion pumping is negligible.

  • PDF

가공된 석탄재를 사용한 석탄재혼합시멘트의 모르터 특성 (The Mortar Properties of Portland Cements Blended with Modified Coal Ashes)

  • 홍원표;노재성;조헌영;정수영;김무한
    • 한국세라믹학회지
    • /
    • 제27권7호
    • /
    • pp.833-840
    • /
    • 1990
  • For the development of multi-functional materials which has water reducing power, air entraining power and waterproofing power as well as blending additive in cement mortar the coal ash was modified with asphalt-stearic acid or asphalt-boiled oil mixtures by mechanical treatment. And the physical properties of cement mortar blended with modified coal ashes were compared with those of the water-tightness-cement mortar and the ordinary-portland-cement mortar added with AE.water reducing agent. The mortar of coalash-blend-cement modified with asphalt-stearic mixture was increased acid about 20% in initial strengths and decreased about 20% in water absorption ratio than those of ordinary coalash-blend-cement. The mortar of coalash-blend-cement modified with asphalt-bolied oil mixture was similar to the cement mortar added with AE.water reducing agent in water reduction ratio, air entraining conents and the initial strengths, also was similar to the water-tightness-cement mortar in water absorption and water permeability ratios.

  • PDF

마이크로 가스터빈 열병합 발전시스템 성능평가 (Performance Test of MGT Combined Heat & Power System)

  • 허광범;박정극;임상규
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.313-316
    • /
    • 2006
  • As Decentralized Generation(DG) becomes more reliable and economically feasible, it is expected that a higher application of DG units would be interconnected to the existing grids. This new market penetration of DG technologies is linked to a large number of factors like technologies costs and performances, interconnection issues, safety, market regulations, environmental issues or grid connection constrains. Korea Electric Power Corporation (KEPCO) has researched performance characteristics of the 60k W class 1) basic start-up & shutdown operation analysis 2) interconnection test 3) MGT -absorption chiller-heater system in the local condition. Variations of heat recovery from exhaust gas has measured according to micro gas turbine output of 15, 30, 45, 60kW. From those results, the performance of the MGT-absorption chiller/heater system has been evaluated. The suggested strategy and experience for the evaluation of the distributed generation will be used for the introduction of other distributed generation technologies into the grid in the future.

  • PDF

구상흑연주철의 $CO_2$레이저 표면경화 특성 (The Characteristics of Ductile Cast Iron Heat-treated by $CO_2$Laser)

  • 정원기;전병철;김재도
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.998-1002
    • /
    • 1997
  • This study has been performed to predict beam absorption with analysis of temperature field by using a FEM in co /sab 2/ laser hardening and to invesrigate into some effects of power density and travel speed of laser beam on the microstructure and hardness of ductile cast iron treated by laser surface hardening technique. Optical micrograph has shown that large martensite and small amount of retained austenite appear in inside hardened zone. Hardness measurement has revealed that the range of maximum hardness value is Hv=415 .+-. 10. The power density increases and the travel speed decreases, the depth of hardened zone increases due to increase of input power density.

  • PDF

화력발전소 보일러내의 열전달에 관한 연구 (A Study on the Heat Transfer in boiler through the performance test in thermal power plant)

  • 권영수;서정세
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.2064-2069
    • /
    • 2004
  • The main reason to analyze heat transfer in boiler inside through the performance test in fossil power plant is to increase plant high efficiency and energy saving movement in the government. Tins study intends to have trend and analyze the boiler heat transfer through the performance test, so it may give us the heat distribution in boiler inside in super-critical and sub-critica1 pressure type power plant

  • PDF

파워기반 소음감소 기법을 이용한 준중형 해치백 후석 고주파성 로드노이즈 전달특성 연구 (A study on the characteristics of high frequency road noise transmission at the rear seat of a hatch back compact car using PBNR (Power Based Noise Reduction) method)

  • 이종현;조세현;이주완;이철현;양정민
    • 한국음향학회지
    • /
    • 제37권4호
    • /
    • pp.248-255
    • /
    • 2018
  • 세단 타입에 비해 해치백 타입의 차량은 실링구조 확보에 어려움이 있기 때문에 후석에서 느껴지는 차폐성능이 열세한 것으로 알려져 있다. 차량의 차폐감 확보를 위해 강건한 실링 시스템과 충분한 흡음/차음 성능이 요구되지만 준중형 이하 세그먼트에서는 원가, 중량의 제약으로 인해 충분한 흡차음 사양 적용에 제한을 받고있어 효율적인 흡차음 사양의 적용이 요구되고 있는 실정이다. 본 연구에서는 정량적인 측정과 비교, 분석이 가능한 파워기반 소음감소(Power Based Noise Reduction, PBNR) 기반의 차음 윈도우 평가를 통해 준중형 해치백 차량의 후석 소음원의 전달 경로를 분석하고 후석 차폐성능 확보를 위한 흡차음 대안을 제시하였다.

마이크로가스터빈 배열부하가 배가스흡수식 냉온수기의 성능에 미치는 영향 (Effect of the Exhaust Heat from Micro Gas Turbine on the Performance Characteristics of the Absorption Chiller)

  • 최경식;손화승;김형식;임상규;허광범
    • 설비공학논문집
    • /
    • 제18권2호
    • /
    • pp.158-162
    • /
    • 2006
  • Micro gas turbine (MGT) has received attention recently as a small-scale distributed power source. Due to many advantages such as their small size, low maintenance cost and minimal vibrations during operation, they are expected to become widespread in a wide range of applications. The exhaust heat emitted by the MGT is in the form of an exhaust gas that is about $270^{\circ}C$ which is an extremely clean gas. Korea Gas Corporation (KOGAS) has researched performance characteristics of a cogeneration system combining 28kW class MGT and 13 USRT class absorption hot and chilled water generator in the local condition. The present results of this study can be summarized as follows: (1) in heating mode, the total efficiency of cogen. system is about $65\%$ and heating capacity is 33kW at 25kW MGP power (2) in cooling mode, COP is about 0.6 at 22kW MGT power.

Comparison of Carbon Dioxide Absorption in Aqueous MEA, DEA, TEA, and AMP Solutions

  • Kim, Young Eun;Lim, Jin Ah;Jeong, Soon Kwan;Yoon, Yeo Il;Bae, Shin Tae;Nam, Sung Chan
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권3호
    • /
    • pp.783-787
    • /
    • 2013
  • The separation and capture process of carbon dioxide from power plants is garnering interest as a method to reduce greenhouse gas emissions. In this study, aqueous alkanolamine solutions were studied as absorbents for $CO_2$ capture. The solubility of $CO_2$ in aqueous alkanolamine solutions was investigated with a continuous stirred reactor at 313, 333 and 353 K. Also, the heat of absorption ($-{\Delta}H_{abs}$) between the absorbent and $CO_2$ molecules was measured with a differential reaction calorimeter (DRC) at 298 K. The solubility and heat of absorption were determined at slightly higher than atmospheric pressure. The enthalpies of $CO_2$ absorption in monoethanolamine (MEA), diethanolamine (DEA), triethanolamine (TEA), and 2-amino-2-methyl-1-propanol (AMP) were 88.91, 70.44, 44.72, and 63.95, respectively. This investigation showed that the heat of absorption is directly related to the quantity of heat for absorbent regeneration, and is dependent on amine type and $CO_2$ loading.