• Title/Summary/Keyword: absorption &

Search Result 45, Processing Time 0.023 seconds

Absorption Characteristics of Carbon Dioxide in Aqueous AMP Solution Adding HMDA (HMDA 첨가에 따른 AMP 수용액의 이산화탄소 흡수특성)

  • Choi Won-Joon;Cho Ki-Chul;Oh Kwang-Joong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.6
    • /
    • pp.605-612
    • /
    • 2005
  • In this study, the possible use of HMDA (Hexamethylenediamine) as additive to enhance reaction between $CO_{2}$ and AMP (2-amino-2-methyl-1-propanol) which has higher absorption capacity than that of MEA (Monoethanolamine) was investigated. Also, the absorption capacity for $CO_{2}$ was compared with addition of HMDA, piperazine or MDEA (N-methyldiethanolamine) into $30\;wt\%$ AMP at $40^{circ}C$ and $CO_{2}$ partial pressure ranging from 0.5 to 120 kPa. Apparent rate constant ($K_{app}$) and absorption capacity with the addition of $5\∼20\;wt\%$ HMDA into AMP increased $214.2\∼276.3\%$ and $29.9\∼91.7\%$ than those of AMP alone. As a result, when $5\;wt\%$ HMDA added into AMP, the increasing rate of the absorption rate and the absorption capacity was found to be the highest. In addition, the absorption capacity increased $6.8\%,\;9.8\%,\;11.6\%$ with addition of MDEA, piperazine or HMDA respectively as compared to AMP alone at $CO_{2}$ partial pressure of 20 kPa. Consequently, HMDA as additive to improve absorption capacity of AMP was superior to other additives.

Absorption and Regeneration of Carbon Dioxide in Aqueous AMP + AEPD and AMP + TIPA Solutions (AMP + AEPD와 AMP + TIPA 수용액을 이용한 이산화탄소의 흡수 및 재생)

  • Kim, Mi-Sook;Choi, Won-Joon;Seo, Jong-Beom;Cho, Ki-Chul;Kim, Soo-Gon;Oh, Kwang-Joong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.5
    • /
    • pp.539-546
    • /
    • 2007
  • Increasing emission of $CO_2$ significantly effects the global warming. Chemical absorption is one of separation methods of $CO_2$ from the industrial flue gases. In this study, the $CO_2$ removal efficiency as well as the $CO_2$ absorption amount of aqueous AMP (2-amino-2-methyl-1-propanol) solutions were measured using the continuous absorption and regeneration apparatus. We investigated the effect of aqueous AMP+AEPD(2-amino-2-ethyl-1, 3-propanediol) and AMP+TIPA (triisopropanolamine) solutions to enhance absorption characteristics of AMP. As a result of this study, the absorption amount and $CO_2$ removal efficiency were increased with adding TIPA into 30 wt.% AMP. The absorption amount and $CO_2$ removal efficiency of aqueous 30 wt.% AMP+5 wt.% TIPA solution were $1.70\;kg-CO_2/kg-absorbent$ and 91.1%, while those of aqueous 30 wt.% AMP solution were $1.58\;kg-CO_2/kg-absorbent$ and 89.3%. In addition, aqueous 30 wt.% AMP+5 wt.% TIPA solution used in the study revealed the high stripping efficiency, which was almost 98%, at the temperature of $110^{\circ}C$. Thus, the temperature of regenerator should be operated at $110^{\circ}C$.

A Study on the Absorption of $CO_2$Using Alkanolamine Solution (Alkanolamine계 수용액을 이용한 이산화탄소 흡수에 관한 연구)

  • 이성남;송호철;현재휴;박진원
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.5
    • /
    • pp.407-414
    • /
    • 2001
  • In this study, the absorption kinetics of $CO_2$onto a mixture of AMP (2-amino-2-methyl-1-propanol) MEA (monoethanolamine) water were investigated at 30 and 4$0^{\circ}C$ using a packed absorption tower. Solubility and absorption rate of $CO_2$into alkanolamine solutions and optimal condition of $CO_2$absorption process were investigated. The experimental conditions are as follows; temperature of 30 and 4$0^{\circ}C$, gas flow rate of 3ι/min for the absorption tower, and liquid flow rate of 0.1ι/min. Feed gas was a mixture of 85% $N_2$and 15% $CO_2$. The experimental results showed that AMP had greater solubilities and faster absorption rates than MEA and DEA. In addition, MEA had the fastest initial reaction rate. To improve the properties of AMP which have low initial reaction rate and high cost, AMP was used with MEA. The mixing ratio was also changed in constant total molarity of 1,2,3 and 4. The experimental results can be summarized as follows: (1) in solubility experiment, the addition of MEA in constant total polarity decreased the solubility of $CO_2$in AMP/MEA mixture. (2) from 0 to about 0.3 in mixing ratio, the solubility of $CO_2$in AMP/MEA mixture had little differences compared with the sum of solubility of AMP only and solubility of MEA only . (3) mixing ratio of 0.3 was found to be an optimal point with the fastest $CO_2$absorption rate.

  • PDF

Absorption Equilibrium of CO2 in the Sterical Hindered Amine, AMP Aqueous Solution (입체장애아민 AMP (2-amino 2-methyl 1-propanol) 수용액의 CO2 흡수평형)

  • Han, Keun-Hee;Lee, Jong-Seop;Min, Byoung-Moo
    • Korean Chemical Engineering Research
    • /
    • v.45 no.2
    • /
    • pp.197-202
    • /
    • 2007
  • This research was basically carried out to extend the application of $CO_2$ absorption processes for flue-gas system, which are mainly applied to a reforming process in petro-chemical industries. In general, MEA absorbent has some problems in flue-gas treatment, such as, degradation, regeneration energy and absorption capacities. As we known, sterical hindered amine, typically AMP (2-amino 2-methyl 1-propanol), have a good potential to improve these problems. In this paper, the characteristics of $CO_2$ absorption in aqueous AMP solution were measured and compared with that of MEA. It has been found that the $CO_2$ absorption capacity in AMP is double than that of MEA in the low $CO_2$ partial pressure system such as flue-gas. Also, the equilibriums of $CO_2$-AMP system were partially suggested, which are essentially needed to design the absorption process.

Effect of PEO viscoelasticity on carbon dioxide absorption in aqueous PEO solution of AMP

  • Park Sang-Wook;Choi Byoung-Sik;Lee Jae-Wook
    • Korea-Australia Rheology Journal
    • /
    • v.17 no.4
    • /
    • pp.199-205
    • /
    • 2005
  • Carbon dioxide was absorbed into aqueous polyethylene oxide (PEO) solution containing AMP in a flat-stirred vessel to investigate the effect of non-Newtonian rheological behavior of PEO on the rate of chemical absorption of $CO_2$, where the reaction between $CO_2$ and AMP was assumed to be a first-order reaction with respect to the molar concentration of $CO_2$ and AMP respectively. The liquid-side mass transfer coefficient, which was obtained from the dimensionless empirical equation containing the properties of viscoelasticity of the non-Newtonian liquid, was used to estimate the enhancement factor due to chemical reaction. PEO with elastic property of non-Newtonian liquid made the rate of chemical absorption of $CO_2$ accelerate compared with Newtonian liquid based on the same viscosity of the solution.

The Removal of Carbon Dioxide using AMP+HMDA in Absorption/Regeneration Continuous Process (흡수/재생 연속공정에서 AMP+HMDA를 이용한 이산화탄소의 제거)

  • Choi, Won-Joon;Cho, Ki-Chul;Oh, Kwang-Joong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.5
    • /
    • pp.507-513
    • /
    • 2005
  • Increasing amounts of anthropogenic $CO_2$ emitted to the atmosphere are believed to be a significant factor in global climate change. Hence, the method of chemical absorption has been suggested to separate and recover acid gases such as $CO_2$. In this study, the characteristics of absorption and regeneration of $CO_2$ for the absorbent which adding HMDA (hexamethylenediamine) into AMP (2-amino-2-methyl-1-propanol), hindered amine, was investigated in lab-scale absorption/regeneration reactor. As a result of this study, the removal efficiency of $CO_2$ increased when adding $5.9\%,\;11.7\%\;and\;23.4\%$ HMDA into $30\%$ AMP respectively. Also, the removal efficiency of $CO_2$ increased $6.5\%,\;8.4\%,\;10.3\%$ respectively as compared to AMP alone when the gas flow rate was 7.5 SL/min. In addition, all absorbents used in the study revealed the high stripping efficiency, which was almost $99\%$, at the temperature of $110^{\circ}C$. Thus, the regeneration tower should be operated at $110^{\circ}C$. At this time, the concentration of exhausted $CO_2$ was higher than $99\%$.

Absorption of Carbon Dioxide into Aqueous AMP Solutions

  • So, Won-Seob;Suh, Dong-Soo;Park, Moon-Ki
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.2 no.1
    • /
    • pp.79-84
    • /
    • 1998
  • The rates of absorption of carbon dioxide into aqueous solutions of 2-amino-2-methyl-1-propanol (AMP) were measured using a semibatch stirred vessel with a plane gas-liquid interface at $25^{\circ}C.$ The absorption rates under the fast reaction regime were analysed using chemical absorption theory. The reaction was found to be first order with respect to both $CO_2$ and the amine.

  • PDF

Effect of Added NH$_3$ to AMP on Absorption Rate for Simultaneous Removal of CO$_2$/NO$_2$ in Composite Absorption Process (복합흡수공정에서 CO$_2$/NO$_2$ 동시제거 시 AMP(2-amino-2-methyl-1-propanol)에 Ammonia 첨가가 흡수속도에 미치는 영향)

  • Seo, Jong-Beom;Choi, Won-Joon;Moon, Seung-Jae;Lee, Gou-Hong;Oh, Kwang-Joong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.12
    • /
    • pp.1287-1293
    • /
    • 2008
  • In this study, a blend of 2-amino-2-methyl-1-propanol (AMP) and ammonia (NH$_3$) was used to achieve high absorption rates for carbon dioxide (CO$_2$) as suggested at several literatures. The absorption rates of aqueous AMP and blended AMP+NH$_3$ solutions with CO$_2$ and nitrogen dioxide (NO$_2$) were measured using a stirred-cell reactor at 303 K. The effect of the added NH$_3$ to enhance absorption characteristics of AMP was studied. The performances were evaluated under various operating conditions. The absorption rates increased following the increase of the concentration of NH$_3$. The absorption rate of NH$_3$ blended into 30 wt.% AMP solution with NO$_2$ at 303 K was 12.6$\sim$32.6% higher than that of aqueous AMP solution without NH3. Also, the addition of 3 wt.% NH$_3$ to 30 wt.% AMP increased 48.2$\sim$41.6% values for the reactions with CO$_2$ and NO$_2$ at 303 K. Therefore, it clearly shows that the reaction rate of AMP with CO$_2$ and NO$_2$ can be increased by the addition of NH$_3$.

Absorption of Carbon Dioxide into Aqueous AMP Solutions

  • Won Seob So;Don
    • Journal of Environmental Science International
    • /
    • v.2 no.1
    • /
    • pp.79-84
    • /
    • 1993
  • The rates of absorption of carbon dioxide into aqueous solutions of 2-amino-2-methyl-1 propanol (AMP) were measured using a semibatch stirred vessel with a plane gas-liquid interface at $25^{\circ}C$. The absorption rates under the fast reaction regime were analysed using chemical absorption theory. The reaction was found to be first order with respect to both $CO_2$ and the amine.

  • PDF

A Study on the EM Wave Absorption Characteristics of Amorphous Metal Powder and Sendust Absorbers for RFID System (RFID 시스템용 Amorphous Metal Powder 및 Sendust 흡수체의 전파흡수 특성 연구)

  • Choi, Dong-Soo;Yoo, Gun-Suk;Choi, Dong-Han;Kim, Dong-Il
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2010.04a
    • /
    • pp.159-160
    • /
    • 2010
  • In this paper, we compared the absorption abilities of AMP and Sendust EM wave absorbers for a port logistics RFID system. Firstly, we fabricated EM wave absorber samples by using each absorbing material, AMP or Sendust, and CPE (Chlorinated Polyethylene) with composition ratios 85 : 15 wt. %. Secondly, we designed the optimum EM wave absorber using the calculated material constants found from the measured input impedance of the samples. Therefore, we confirmed that imaginary factor of complex relative permeability influences absorption ability and that AMP is better absorbing material than Sendust at the frequency band of 433 MHz.

  • PDF