• Title/Summary/Keyword: absolute values

Search Result 789, Processing Time 0.026 seconds

Dosimetric Evaluation of an Automatically Converted Radiation Therapy Plan between Radixact Machines

  • Lee, Mi Young;Kang, Dae Gyu;Kim, Jin Sung
    • Progress in Medical Physics
    • /
    • v.31 no.4
    • /
    • pp.153-162
    • /
    • 2020
  • Purpose: We aim to evaluate the accuracy and effectiveness of an automatically converted radiation therapy plan between Radixact machines by comparing the original plan with the transferred plan. Methods: The study involved a total of 20 patients for each randomly selected treatment site who received radiation treatment with Radixact. We set up the cheese phantom (Gammex RMI, Middleton, WI, USA) with an Exradin A1SL ion chamber (Standard Imaging, Madison, WI, USA) and GAFCHROMIC EBT3 film (International Specialty Products, Wayne, NJ, USA) inserted. We used three methods to evaluate an automatically converted radiation therapy plan using the features of the Plan transfer. First, we evaluated and compared Planning target volume (PTV) coverage (homogeneity index, HI; conformity index, CI) and organs at risk (OAR) dose statistics. Second, we compared the absolute dose using an ion chamber. Lastly, we analyzed gamma passing rates using film. Results: Our results showed that the difference in PTV coverage was 1.72% in HI and 0.17% in CI, and majority of the difference in OAR was within 1% across all sites. The difference (%) in absolute dose values was averaging 0.74%. In addition, the gamma passing rate was 99.64% for 3%/3 mm and 97.08% for 2%/2 mm. Conclusions: The Plan transfer function can be reliably used in appropriate situations.

Combined effect of glass and carbon fiber in asphalt concrete mix using computing techniques

  • Upadhya, Ankita;Thakur, M.S.;Sharma, Nitisha;Almohammed, Fadi H.;Sihag, Parveen
    • Advances in Computational Design
    • /
    • v.7 no.3
    • /
    • pp.253-279
    • /
    • 2022
  • This study investigated and predicted the Marshall stability of glass-fiber asphalt mix, carbon-fiber asphalt mix and glass-carbon-fiber asphalt (hybrid) mix by using machine learning techniques such as Artificial Neural Network (ANN), Support Vector Machine (SVM) and Random Forest(RF), The data was obtained from the experiments and the research articles. Assessment of results indicated that performance of the Artificial Neural Network (ANN) based model outperformed applied models in training and testing datasets with values of indices as; coefficient of correlation (CC) 0.8492 and 0.8234, mean absolute error (MAE) 2.0999 and 2.5408, root mean squared error (RMSE) 2.8541 and 3.3165, relative absolute error (RAE) 48.16% and 54.05%, relative squared error (RRSE) 53.14% and 57.39%, Willmott's index (WI) 0.7490 and 0.7011, Scattering index (SI) 0.4134 and 0.3702 and BIAS 0.3020 and 0.4300 for both training and testing stages respectively. The Taylor diagram also confirms that the ANN-based model outperforms the other models. Results of sensitivity analysis show that Carbon fiber has a major influence in predicting the Marshall stability. However, the carbon fiber (CF) followed by glass-carbon fiber (50GF:50CF) and the optimal combination CF + (50GF:50CF) are found to be most sensitive in predicting the Marshall stability of fibrous asphalt concrete.

Hourly Water Level Simulation in Tancheon River Using an LSTM (LSTM을 이용한 탄천에서의 시간별 하천수위 모의)

  • Park, Chang Eon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.66 no.4
    • /
    • pp.51-57
    • /
    • 2024
  • This study was conducted on how to simulate runoff, which was done using existing physical models, using an LSTM (Long Short-Term Memory) model based on deep learning. Tancheon, the first tributary of the Han River, was selected as the target area for the model application. To apply the model, one water level observatory and four rainfall observatories were selected, and hourly data from 2020 to 2023 were collected to apply the model. River water level of the outlet of the Tancheon basin was simulated by inputting precipitation data from four rainfall observation stations in the basin and average preceding 72-hour precipitation data for each hour. As a result of water level simulation using 2021 to 2023 data for learning and testing with 2020 data, it was confirmed that reliable simulation results were produced through appropriate learning steps, reaching a certain mean absolute error in a short period time. Despite the short data period, it was found that the mean absolute percentage error was 0.5544~0.6226%, showing an accuracy of over 99.4%. As a result of comparing the simulated and observed values of the rapidly changing river water level during a specific heavy rain period, the coefficient of determination was found to be 0.9754 and 0.9884. It was determined that the performance of LSTM, which aims to simulate river water levels, could be improved by including preceding precipitation in the input data and using precipitation data from various rainfall observation stations within the basin.

The Normal Stress of TiO2 Electrorheological Fluid and Its Model Prediction (이산화티타늄 전기유변 유체의 수직 응력과 정전기 분극 모델에 의한 전산모사)

  • Young Dae Kim
    • Korean Chemical Engineering Research
    • /
    • v.62 no.3
    • /
    • pp.269-273
    • /
    • 2024
  • The normal stress of TiO2 ER fluid under an electric field showed negative values due to the electrostatic attraction force in the normal direction between particles and the absolute value increased dramatically with electric field strengths. The normal yield stress exhibited E2 dependence similar to the dynamic yield stress, indicating that normal stress can be utilized for evaluating the ER effect. Numerical simulation demonstrated good qualitative agreement with the experimental data and suggested that the decrease in the absolute value of normal stress with increasing shear rates was attributed to the rearrangement of particle configurations under shear.

Strains of abutment and bones on implant overdentures (임플란트 피개의치에서 지대주와 골의 변형률에 관한 연구)

  • Kim, Myung-Seok;Heo, Seong-Joo;Koak, Jai-Young;Kim, Sung-Kyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.222-231
    • /
    • 2009
  • Statements of the problem: Over the past decades, conventional complete dentures were used for various patients although they have incomplete function. Overdentures using dental implants could help the improvement of denture function. Purpose: The purpose of this study was to compare the strains of abutment and bone on implant overdenture between splinted and unsplinted type of prosthesis. Additionally, the strain values of parallel placed implant model and unparallel placed implant model were compared. Material and methods: Two acrylic resin model were prepared and two implants were placed at the canine positions in each model. In the first model, two implant were placed parallel. In the second model, two implants were placed with 10 degree labiolingual divergence. Two types of abutment were connected to the fixtures alternatively. One was splint type of Hader bar, the other was unsplint type of ball abutment. Overdentures were fabricated with corresponding attachment systems and seated on abutments. Strains of abutments and labial bone simulants were measured with electric resistance strain gauges when static load from 100 N to 200 N were applied to overdentures. Results: 1. Splinted type of overdentures using bar and clip showed higher absolute strain values. But the strain was compressive and the load was shared by two implants(P<.05). 2. Unsplinted type overdentures using ball and O-ring showed low absolute strain values(P<.05). 3. Labially inclined implant showed higher tensile strain values in unsplinted type of prosthesis than in splinted type of prosthesis. Lingually inclined implant showed rather low strain values under load(P<.05). 4. Non parallel implant model showed higher absolute strain values than parallel placed implant model comprehensively(P<.05).

Development of Continuous Cross-Flow Rice Drying Model (벼의 횡류 연속식 건조 모델 개발)

  • 송대빈;고학균
    • Journal of Biosystems Engineering
    • /
    • v.22 no.3
    • /
    • pp.279-288
    • /
    • 1997
  • This study was worked out to obtain fundamental data needed for developing a continuous type dryer. The drying process in a cross-flow type continuous dryer was expressed as partial differential equations, and a drying simulation model for predicting rice moisture content, rice temperature, drying air absolute humidity, drying air temperature was developed by using the finite difference method. To validate the performance of the drying simulation model, a prototype continuous dryer was constructed in this study. The size of the test dryer was one-tenth to that of a commercial continuous dryer. The difference in the outlet rice moisture content between the predicted values and the measured values was within 0.5%, that of outlet rice temperature was below $3^{\circ}C$, that of drying air temperature in drying bed was within $8^{\circ}C$ and that of relative humidity of outlet drying air was big because of the different measuring point. In addition, a drying simulation model for a actual size continuous dryer with double flow was developed in this study. This drying simulation model included the rice mixing effect in the middle of drying length. The difference of outlet moisture content between the predicted and the measured values showed below 0.5% in this study.

  • PDF

Comparative Analysis on luminous efficiency of bulb type LED lamps using both photogoniometer and integrating shpere (절대광속 측정기와 적분구를 이용한 벌브타입 LED 램프의 광효율 측정분석)

  • Jeon, Sang-Kyoo;Na, Nong-Hyuk;Kim, Do-Hwan;Lee, Hyun-Young;Cho, Mee-Ryoung;Choi, Yong-Woon;Yang, Seong-Yong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.149-151
    • /
    • 2009
  • This paper gives a comparative analysis on the luminous efficiency of the bulb type LED lamps. we compare and analyze the measurement values bulb type LED lamps using both photogoniometer and integrating sphere. The volt and watt of one 1map are 220 V and 7 W, respectively. The volt and watt of other one are 100 V and 5.3 W, respectively. the values of those were 79.7 1m/W and 76.9 1m/W in the integrating sphere, respectively. Similarly, the values of those were 80.2 1m/W and 79.3 1m/W on the photogoniometer, respectively. As a result, the value of luminous efficiency can be measured using either integrating sphere or absolute goniometer regardless of the difference in case of bulb type LED lamps.

  • PDF

Formant Measurements of Complex Waves and Vowels Produced by Students (복합음과 대학생이 발음한 모음 포먼트 측정)

  • Yang, Byung-Gon
    • Speech Sciences
    • /
    • v.15 no.3
    • /
    • pp.39-51
    • /
    • 2008
  • Formant measurements are one of the most important factors to objectively test cross-linguistic differences among vowels produced by speakers of any given languages. However, many speech analysis softwares present erroneous estimates and some researchers use them without any verification procedures. The purposes of this paper are to examine formant measurements of complex waves which were synthesized from the average formant values of five Korean vowels using three default methods in Praat and to verify the measured values of the five vowels produced by 20 students using one of the methods. Variances along the time axis are discussed after determining absolute difference sum from the 1/3 vowel duration point. Results show that there were smaller measurement errors by the burg method. Also, greater errors were observed in the sl or lpc methods mostly caused by the inappropriate formant settings. Formant measurement deviations were greater in those vowels produced by the female students than those of the male students, which were mostly attributed to the settings for the vowels /o, u/. Formant settings can best be corrected by changing the number of formants to the number of visible dark bands on the spectrogram. Those results suggest that researchers should check the validity of the estimates from the speech analysis software. Further studies are recommended on the perception test of the original sound with the synthesized sound by the estimated formant values.

  • PDF

A study on the optimal design of automobile suspension system (자동차 懸架裝置의 최적설계에 관한 연구)

  • Kim, Ho-Ryong;Choi, Sub
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.3
    • /
    • pp.437-443
    • /
    • 1987
  • An optimal design to improve the ride quality was performed with the time and frequency domain analysis based on both of deterministic and random road profiles. The objective function is established to minimize the absorbed power while the constraints are taken so as to satisfy the condition for the stability of vehicle. The result of the optimal design shows that the rms for the acceleration of a driver and his seat is within the critical values for the ride quality from ISO. The optimal values obtained show that the maximum absolute acceleration of the driver and his seat has significantly been reduced and the reference limits on the relative displacement have satisfied their feasibility. As the optimal value according to a specific speed is the results from the optimization process, a global optimum value should be determined to be the one which gives th minimum values of total sum of absorbed power with respect to various speed.

Analysis and Luminous Measurement on Architectural Outdoor Lighting of the Famous Nightscape Cities - Las Vegas, Shanghai, and Hong Kong - (야경이 유명한 도시의 경관조명 고찰 및 휘도분석 - 라스베가스, 상해, 홍콩 -)

  • Choi, An-Seop;Jung, Yeon-Hong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.31-40
    • /
    • 2009
  • Tourist cities as like Las Vegas in USA, Shanghai and Hong Kong in China show various architectural outdoor lighting methodologies and techniques. For these three cities, architectural outdoor lighting methods and techniques were investigated, and the luminous values of advertising illuminants as well as the maximum and minimum luminous values on the walls were measured. Then, based on current CIE luminance standard and IES recommended luminance ratio, characteristics of architectural outdoor lighting in each city are analyzed through the absolute and relative measured luminance values.