• Title/Summary/Keyword: abrasive wear

Search Result 288, Processing Time 0.028 seconds

Mechanical Properties and Solid Lubricant Wear Behavior of MMCs Reinforced with a Hybrid of $Al_{2}O_{3}$ and Carbon Short Fibers (알루미나와 탄소단섬유를 혼합한 금속복합재료의 기계적 성질과 고체윤활 마모거동)

  • 송정일;봉하동;한경섭
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.4
    • /
    • pp.968-980
    • /
    • 1995
  • Al/Al$_{2}$O$_{3}$/C hybrid metal matrix composites are fabricated by the direct squeeze infiltration method. From the microstructure of Al/Al$_{2}$O$_{3}$/C composites, uniform distribution of reinforcements and good bondings are found. Optimum processing conditions for preforms and squeeze castings are suggested. Mechanical properties, such as elastic modulus, elongation, 0.2% offset yield strength and ultimate tensile strength are obtained. Through the abrasive were test and wear surface analsis, wear behavior and its mechanism of AC2B aluminum and Al/Al$_{2}$O$_{3}$/C composites can be characterized under various sliding speed conditions. Tensile strenght elongation of Al/Al$_{2}$O$_{3}$/C composites are decreased with increasing the addition of carbon fiber. On the contrary, elastic modulus of Al/Al$_{2}$O$_{3}$/C composites is slightly improved compared with that of the unreinforced matrix alloy. The addition of carbon fiber to al/al$_{2}$O$_{3}$/C composites gives rise to improvement of the wear resistance. Specially, carbon chopped fibers play an important role in interfering sticking between the counter material and metal matirix composites. Al/Al$_{2}$O$_{3}$/C composites are suitable to high speed due to solid lubication of carbon. And wear model of Al/Al$_{2}$O$_{3}$/C composites is suggested by the examination of worn surfaces.

Comparison of abrasive wear characteristics according to particle size of newly developed dental alumina ceramic dressers (새롭게 개발된 치과용 알루미나 세라믹 드레서의 입자 크기에 따른 연삭 마모 특성의 비교)

  • Soo-Chul Park;Jong-Kyoung Park
    • Journal of Technologic Dentistry
    • /
    • v.46 no.3
    • /
    • pp.107-113
    • /
    • 2024
  • Purpose: This study aimed to develop dental alumina ceramic dressers, evaluate their abrasive wear characteristics based on particle size, and identify dental dressers with optimal particle size and performance. Methods: Commercial ceramic dressers (n=5) were selected as the control group, whereas alumina ceramic dressers with 80-grit and 120-grit particles were fabricated as the experimental groups (n=5 each). Prepared specimens were assessed for surface roughness, wear resistance, and abrasiveness against a wear-inducing element (SUS304 stainless steel ball). Means and standard deviations were calculated for each test. Statistical analysis was performed using the Kruskal-Wallis H test with Bonferroni correction (α=0.05) via SPSS Statistics ver. 23.0 (IBM). Results: Surface roughness was highest in the 80-grit group (22.734±1.308 ㎛), followed by 120-grit group (21.804±0.785 ㎛), and lowest in control group (15.782±0.223 ㎛). Wear resistance was greatest in 120-grit group (0.007±0.002 g), followed by the 80-grit group (0.007±0.004 g), and lowest in the control group (0.370±0.010 g). Furthermore, abrasiveness against the wear-inducing element (SUS304 stainless steel ball) was highest in 120-grit group (0.017±0.003 g), followed by the 80-grit group (0.015±0.003 g), and lowest in control group (0.010±0.001 g). Conclusion: Based on the combined results of surface roughness, wear resistance, and abrasiveness against a wear-inducing element, the newly developed alumina ceramic dressers show promise for clinical application.

Fracture and Wear Behavior of Dental Composite Resins Containing Prepolymerized Particle Fillers (유기복합필러를 함유하는 차과용 컴퍼짓 레진의 파괴와 마멸거동)

  • Kim, Yeong-Bin;Kim, Gyo-Han;Kim, Seok-Sam;Im, Jeong-Il
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.2 s.173
    • /
    • pp.464-471
    • /
    • 2000
  • The fracture and wear behavior of dental composite resins containing prepolymerized particle fillers were investigated. Composite resins such as Metafil, Silux Plus, Heliomolar and Palfique Estelite were selected as specimens and contents of filler in specimens in order to evaluate the effect of prepolymerized particle fillers in fracture and wear characteristics. Ball on flat wear tester was used for the wear test at room temperature. The friction coefficient of Metafil was quite high relatively, and the wear resistances of Silux Plus and Palfique Estelite were better than those of Metafil and Heliomolar at the same experimental condition. It was found that the main wear mechanism was abrasive wear containing of plastic deformation of dental material.

Wear Behaviours of Dental Composite Resins Containing Prepolymerized Particle Fillers (1st Report) (유기복합필러를 포함하는 치과용 콤포짓트 레진의 마모거동(제1보))

  • 임정일;김교한;김석삼
    • Tribology and Lubricants
    • /
    • v.15 no.2
    • /
    • pp.212-217
    • /
    • 1999
  • The wear characteristics and wear mechanisms of dental composite resins were investigated. Composite resins such as Metafil, Silux Plus, Heliomolar and Palfique Estelite were selected as specimens and contents of filler in specimens in order to evaluate the effect of Prepolymerized Particle Fillers in friction and wear characteristics. Ball on flat wear tester was used for the wear test at room temperature. The friction coefficient of Metafil was quite high relatively, and the wear resistances of Silux Plus and Palfique Estelite were better than that of Metafil and Heliomolar at the same experimental condition. It was found that The main wear mechanism is plastic flow and abrasive wear by failure of filler's bond to the matrix.

Nano Wear Behavior of a-C Films with Variation of Surface Roughness (표면거칠기의 변화에 따른 a-C 박막의 나노마멸 거동)

  • 채영훈;장영준;나종주;김석삼
    • Tribology and Lubricants
    • /
    • v.20 no.3
    • /
    • pp.125-131
    • /
    • 2004
  • Nano-wear behavior of amorphous carbon films was studied by Atomic Force Microscopy. The a-C films are deposited on Si(100) substrate by DC magnetron sputtering method. The influences of different surface roughness on the nano-wear are investigated. Nano-wear tests were carried out using a very sharp diamond coated tip. Its spring constant was 1.6 N/m and radius of curvature was 110 nm. Normal force used in the wear tests ranged 0 to 400 nN. It was found that surface depression occurred during scratching because of plastic deformation and abrasive wear (cutting St ploughing). Wear depth increased linearly with normal force. Changing the surface roughness variables according to the bias pulse control, the less surface roughness decreased the wear depth. The thickness did not affect the wear resistance.

Wear Characteristics of Atomic force Microscope Tip (Atomic Force Microscope Tip 의 마멸특성에 관한 연구)

  • 정구현;김대은
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.5
    • /
    • pp.189-195
    • /
    • 2003
  • Atomic Force Microscope (AFM) has been widely used in micro/nano-scale studies and applications for. the last few decade. In this work, wear characteristics of silicon-based AFM tip was investigated. AFM tip shape was observed using a high resolution SEM and the wear coefficient was approximately calculated based on Archard's wear equation. It was shown that the wear coefficient of silicon and silicon nitride were in the range of ${10}^{-1}$~${10}^{-3}$ and ${10}^{-3}$~${10}^{-4}$, respectively. Also, the effect of relative humidity and sliding distance on adhesion-induced tip wear was discussed. It was found that the tip wear has more severe for harder test materials. Finally, the probable wear mechanism was analyzed from the adhesive and abrasive interaction point of view.

The Evaluation on Wear Characteristics of the Crane Sheave (크레인용 시브 강재의 마멸특성 평가)

  • Park Yongjae;Ryu Jungbuk;Kim Seocksam
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.306-311
    • /
    • 2004
  • The sliding wear characteristics of the crane sheave were investigated using a pin-on-disk rig tester The experiment was conducted using a high carbon steel wire that was upper material, also carbon steel castings and carbon steel for machine structural use that was disk material. There are various operating conditions in this work. At the room temperature, we carried out the wear test under a grease lubrication. The results of wear test showed that carbon steel for machine structural use have lower wear volume, also the wear curves are linearly increased with increasing of sliding velocity The wear mechanism of a disk is the abrasive, adhesion, and fatigue wear under lubrication.

  • PDF

Fretting Wear Characteristics of Inconel 690 Tubes in Room Temperature (인코넬 690 튜브의 상온 프레팅 마멸 특성에 대한 연구)

  • Chung, Il-Sup;Lee, Myung-Ho;Chai, Young-Suck
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.4
    • /
    • pp.329-336
    • /
    • 2009
  • A fretting wear test rig for cross contacting tube specimens, which employs a piezoelectric actuator, has been developed. Along with the simple loading scheme using dead weights, the rig is very simple to be used also. The accuracy was found acceptable. Inconel 690 tubes were tested in room temperature and ambient condition. Normal load and sliding amplitude range up to 35N and $100{\mu}m$, respectively. The sizes of wear scar and the wear volumes were measured, and wear coefficients have been calculated based on those. A study on the fretting wear mechanism of the tubes has been attempted via microscopic observation. Rugged wear surfaces are induced by the separation and adhesion of particles and formation and subsequent fracture of surface layers. Lapped specimens were also tested and abrasive wear seems to be playing a dominant role.

Wear Characteristics of Atomic Force Microscope Tip

  • Chung, Koo-Hyun;Kim, Dae-Eun
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.5 no.2
    • /
    • pp.39-45
    • /
    • 2004
  • Atomic Force Microscope (AFM) has been widely used in micro/nano-scale studies and applications for the last few decades. In this work, wear characteristics of silicon-based AFM tip was investigated. AFM tip shape was observed using a high resolution SEM and the wear coefficient was approximately calculated based on Archard's wear equation. It was shown that the wear coefficient of Si and ${Si}_3$$N_4$ tips were in the range of ${10}^{-1}$~${10}^{-3}$and ${10}^{-3}$~${10}^{-4}$, respectively. Also, the effect of relative humidity and sliding distance on adhesion-induced tip wear was investigated. It was found that the tip wear has more severe for harder counter surface materials. Finally, the probable wear mechanism was analyzed from the adhesive and abrasive interaction point of view.

A Study on Friction and Wear Behavior of Carbon Fiber Reinforced Polyetheretherketone (탄소 섬유 보강 폴리에테르에테르케톤의 마찰 및 마모 거동에 관한 연구)

  • Ryoo, Sung-Kuk;Kim, Kyung-Woong
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.772-779
    • /
    • 2000
  • The friction and wear behavior of short carbon fiber reinforced polyetheretherketone was studied experimentally under dry sliding conditions against SCM440(AISI 4140) disks with a different surface roughness and hardness at the low sliding speeds and the high pressures on a pin-on-disk apparatus. Under the low disk surface roughness value the earsplitting noise and stick-slip were occurred. The increased adhesion friction and wear factor with stick-slip made the friction and wear behavior worse. Under the high disk surface hardness the break and falling-off of carbon fibers were accelerated. The carbon fibers fallen off from the matrix were ground into powder between two wear surfaces and this phenomenon caused a abrasive friction and wear factor to increase. So the friction and wear behavior became worse. With the transfer film made of wear particles formed on a disk, the carbon powder film formed on a pin lowered a friction coefficient.

  • PDF