• 제목/요약/키워드: a valve mode

검색결과 191건 처리시간 0.033초

ER 현가장치 및 ER 브레이크를 적용한 전체차량의 거동분석 (Maneuver Analysis of Full-Vehicle Featuring Electrorheological Suspension and Electrorheological Brake)

  • 성금길;최승복
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.1125-1130
    • /
    • 2007
  • This paper presents a maneuver analysis of a full-vehicle featuring electrorheological (ER) suspension and ER brake. In order to achieve this goal, an ER damper and an ER valve pressure modulator are devised to construct ER suspension and ER brake systems, respectively. After formulating the governing equations of the ER damper and ER valve pressure modulator, they are designed and manufactured for a middle-sized passenger vehicle, and their field-dependent characteristics are experimentally evaluated. The governing equation of motion for the full-vehicle is then established and integrated with the governing equations of the ER suspension and ER brake. Subsequently, a sky-hook controller for the ER suspension and a sliding mode controller for the ER brake are formulated and implemented. Control performances such as vertical displacement and braking distance of vehicle are evaluated under various driving conditions through computer simulations.

  • PDF

기체연료주입계의 긴 원형도관에서 기체 흐름의 유형 (2) (Gas Flow Pattern Through a Long Round Tube of a Gas Fueling System (II))

  • 인상렬
    • 한국진공학회지
    • /
    • 제15권6호
    • /
    • pp.594-604
    • /
    • 2006
  • 일정한 기체 공급 압력에서 정해진 만큼 밸브를 개방하는 방식과 밸브를 조절하여 일정한 유량을 흐르도록 하는 두 가지 기체 주입 방식의 작동특성에 대한 시뮬레이션을 통해 공급 압력, 밸브 컨덕턴스, 유량 등 시스템 조건 및 기체 수송관의 길이와 굵기에 따라 기체흐름의 유형이 어떻게 바뀌는지 조사했다.

역지밸브의 고장 원인 분석 (Analysis of Failure Causes for Check Valves)

  • 송석윤;유성연
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.607-612
    • /
    • 2005
  • Check valves playa vital role in the operation and protection of nuclear power plants. Check valves failure in nuclear power plants often lead to a plant transient or trip. An overview of the failure history of check valves needs to identify key area where resources can be best applied to further improve their reliability, and provide cost effective means for failure reduction. The analysis of historical failure data gives information on the populations of various types of check valves, the systems they are installed in, failure modes, effects, methods of detection, and the mechanisms of the failures. The results presented are based on information derived from operating records, nuclear industry reports, manufacturer supplied information. A majority of check valve failures are caused by improper application. Failure modes are identified for swing and lift check valves. Failures involving improper seating and valve disc stuck comprised the largest percentage of failures.

  • PDF

자동차 제동 솔레노이드 밸브용 디지털 PWM 컨트롤러 설계 (A Design of digital PWM controller for automotive brake solenoid valve)

  • 김동현;신창식;서진호;신경욱
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2014년도 춘계학술대회
    • /
    • pp.152-155
    • /
    • 2014
  • ABS/ESC 기능 통합 SoC에 사용되는 자동차 제동 솔레노이드 밸브 구동용 디지털 PWM 컨트롤러를 설계하였다. 직접 제어와 PI 제어 방식을 지원하도록 설계된 PWM 컨트롤러는 총 12채널로 구성된다. 직접 제어 방식의 6개 채널은 설정된 PWM 듀티값에 따라 일정한 PWM을 출력하며, PI 제어 방식의 6개의 채널은 설정된 전류값을 기준으로 드라이버의 전류 값에 따라 변화하는 PWM을 출력하여 일정한 전류를 갖도록 설계되었다. 또한 솔레노이드 밸브 열림 감지, Dither, PWM 위상 시프트 기능 등을 갖는다. 설계된 PWM 컨트롤러는 44,779 게이트로 구현되었으며, 0.18um CMOS 공정으로 제작된 칩의 측정 결과로부터 기능이 정상적으로 동작하는 것을 확인하였다.

  • PDF

가압펌프장의 수격완화설비에 대한 보수·보강 사례 (Case Study of Repair Works on Surge Suppression Device for Booster Pumping Station)

  • 김상균;이동근;이계복;김경엽
    • 한국유체기계학회 논문집
    • /
    • 제8권4호
    • /
    • pp.20-26
    • /
    • 2005
  • When the pumps are started or stopped for the operation or tripped due to the power failure, the hydraulic transients occur as a result of the sudden change in velocity. The field tests on the waterhammer were carried out for Pangyo booster pumping station in which had six booster pumps and two in-line pumps with the motor of output 1,700 kW, respectively. The booster pumping station was equipped with the pump control valve as the main surge suppression device, and the surge relief valve as auxiliary one. But the pump control valve had not early controlled in the planned closing mode, the slamming occurred to the valve of which abruptly closed during the large reverse flow. Because the positive pressure wave caused by the pump failure was superposed on the slam surge, the upsurge increased so extremely that the pump control valve was damaged. After the air chambers were additionally installed in the booster pumping station, it was preyed that the water supply system acquire the safety and reliability on the pressure surge.

A Study on Vehicle-based Durability Evaluation for Weight-reduced Valve Parts of the Dual Clutch Transmission

  • ChanEun Kim;TaeWook Kim
    • Tribology and Lubricants
    • /
    • 제40권1호
    • /
    • pp.24-27
    • /
    • 2024
  • A monotype valve body for a dual clutch transmission has the potential to reduce costs, weight, and manufacturing time by modularizing various parts, including those of existing solenoid packs and valve bodies, into one through the application of super-precision die casting technology. However, this approach may lead to challenges such as reduced rigidity and increased interference due to modularization and compactness, impacting both product performance due to the reduced weight as well as durability and reliability. Unlike existing products, this approach requires a high-precision thin-wall block to avoid more complicated flow line formation, interference between flow lines, and leaks, as well as a strict quality requirement standard and precise inspections including detection of internal defects. To conduct precise inspections, we built an equivalent model corresponding to a driving distance of 300,000 km. Testing involved simulating actual road loads using a real vehicle and a chassis dynamometer in the FTP-75 mode (EPA Federal Test Procedure). The aim of the study was to establish a vehicle load-based part durability model for manufacturing a mono-type valve body and to develop fundamental technology for part weight reduction through preliminary design by introducing analytical weight reduction technology based on the derived results.

목표치 필터형 2자유도 PID 제어기를 이용한 공기식 제어밸브의 제어 특성 연구 (A Study on the Characteristic of Control Valve using 2DOF PID Controller with Target Value Filter)

  • 유경렬;김동화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 B
    • /
    • pp.809-811
    • /
    • 1999
  • The three-mode PID controller is widely used in plant because control algorithm is simple and tuning method is general. But the conventional PID controller can not have the both purpose of setpoint tracking and disturbance rejection at the same time. In this paper, we studied the application 2DOF PID controller to pneumatic control valve through simulation and experiments. Results are Presented a satisfactory response

  • PDF

Simulation and transient analyses of a complete passive heat removal system in a downward cooling pool-type material testing reactor against a complete station blackout and long-term natural convection mode using the RELAP5/3.2 code

  • Hedayat, Afshin
    • Nuclear Engineering and Technology
    • /
    • 제49권5호
    • /
    • pp.953-967
    • /
    • 2017
  • In this paper, a complete station blackout (SBO) or complete loss of electrical power supplies is simulated and analyzed in a downward cooling 5-MW pool-type Material Testing Reactor (MTR). The scenario is traced in the absence of active cooling systems and operators. The code nodalization is successfully benchmarked against experimental data of the reactor's operating parameters. The passive heat removal system includes downward water cooling after pump breakdown by the force of gravity (where the coolant streams down to the unfilled portion of the holdup tank), safety flapper opening, flow reversal from a downward to an upward cooling direction, and then the upward free convection heat removal throughout the flapper safety valve, lower plenum, and fuel assemblies. Both short-term and long-term natural core cooling conditions are simulated and investigated using the RELAP5 code. Short-term analyses focus on the safety flapper valve operation and flow reversal mode. Long-term analyses include simulation of both complete SBO and long-term operation of the free convection mode. Results are promising for pool-type MTRs because this allows operators to investigate RELAP code abilities for MTR thermal-hydraulic simulations without any oscillation; moreover, the Tehran Research Reactor is conservatively safe against the complete SBO and long-term free convection operation.

멀티형공조시스템의 효과적인 운전을 위한 시스템운전알고리즘 (A System Operating Algorithm for the Effective Operation of a Multi-type Air-conditioning System)

  • 한도영;박관준
    • 설비공학논문집
    • /
    • 제18권7호
    • /
    • pp.587-595
    • /
    • 2006
  • A system operating algorithm was developed for the effective operation of a multi-type air-conditioning system. The system operating algorithm includes control algorithms for a safety mode, an initial operating mode, a stabilization mode, a fault diagnosis mode, an efficiency mode, and a tracking mode. Various tests were performed to show the effectiveness of these algorithms. Tests showed good results for the operation of a multi-type air-conditioning system. Therefore, these algorithms developed for this study may be used for the effective control of a multi-type air-conditioning system.

산화제 탱크 2단계 압력 설정을 위한 벤트/릴리프밸브 설계 (Design of Vent Relief Valve for Bi-level Pressure Setting of Oxidizer Tank)

  • 고현석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.1051-1053
    • /
    • 2017
  • 2단계 압력 설정이 가능하도록 산화제 탱크용 벤트/릴리프밸브를 설계하였다. 압력 편차를 줄이기 위하여 최소 캐비티 부피를 계산하였고 모델링을 활용하여 밸브 작동 특성을 해석하였다. 해석 결과를 토대로 검증을 위한 시제품을 제작할 예정이다.

  • PDF