• 제목/요약/키워드: a set value

검색결과 3,374건 처리시간 0.049초

장비정도관리에 Calibrator[I-125] Set 적용 (The Application of New Calibrator[I-125]Set for Equipment Quality Management)

  • 김지나;안재석;원우재
    • 핵의학기술
    • /
    • 제19권2호
    • /
    • pp.108-111
    • /
    • 2015
  • Purpose Lately, in accordance with the increasing interest about Healthcare accreditation program and International laboratory accreditation scheme, requirements about the instrument quality management are gradually taking shape. In nuclear medicine In vitro laboratory, the most typical instruments are multi detector gamma counter and automatic dispensing system. Each laboratory continue with the quality control adequate for circumstances. The purpose of this study is to application and establish the new Calibrator[I-125]Set which is efficient at standardization of equipment quality management. Materials and Methods Deviation between detectors were measured with 12 solid samples of the Calibrator[I-125]Set. their activities differ from each other by less than 1%. Multi detector gamma counters are GAMMA-10;Shinjin medics. Inc, Goyansi, Korea(Gamma counter A), SR300;Stratec biomedical systems AG, Gewerbestr, Germany(Gamma counter B) and COBRA II; Packard Instrument Co. Inc, Meriden, USA(Gamma counter C). Evaluation of two automatic dispensing system used A, B liquid tracer of the Calibrator[I-125]Set. After dispensing and counting, calculated using the ratio of the measured value and proposed value. We used solution A for 20, 25ul and solution B for 50, 100ul. Method of data analysis and reference range was provided by kit documentation. Furthermore, we could calculate our counter efficiency indirectly. Results The CV(%) of measured values by Gamma counter A, B, C are 0.34, 0.70, 1.30. Calculated value are 1.05314, 2.10419, 4.08485. Provided reference range is less than 3. A dispensing system's calculated values are 0.986, 0.989, 1.023, 1.017 and B are 0.874, 0.725, 1.021, 0.904. Provided reference range is from 0.95 to 1.05. Also, counter's efficiency are 74.18, 72.79, 74.32% at counter A, B, C and efficiency of the one detector counter is 79.26%. Conclusion If using this Calibrator[I-125]Set after verifying whether quality assurance, is applicable to equipment quality management on behalf of the role of gold standard.

  • PDF

A Tuning of Intrusin Detection Model With Fuzzy Set

  • KIM Young-Soo
    • 정보보호학회논문지
    • /
    • 제7권4호
    • /
    • pp.11-21
    • /
    • 1997
  • This paper introduces a statistical approach of intrusion detection and tunes an intrusion detection model using fuzzy ste. We describel the method of applying fuzzy set for NIDES intensity measure. By using fuzzy set, we improve the algorithm for evaluating score value of NIDES, and present a possibility of intrusion detection system.

FPGA를 이용한 DC Servo Motor의 속도제어 (Speed Control of DC Servo Motor using FPGA)

  • 박인수;서용원;박광현
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2009년도 정보 및 제어 심포지움 논문집
    • /
    • pp.313-315
    • /
    • 2009
  • In this thesis, A methodology of system implement for PID controller, PWM logic, HSC logic, Host Communication and external DAC interface are implemented into single FPGA chip is proposed. The implemented system is used to control the speed of DC servo motor. A DATA block transfers set point value(SV) and P, I, D gain parameters to the corresponding Blocks respectively by the Host Communication to Computer. A HSC block generates process value(PV) by a pulse and $90^{\circ}$ shifted pulse from the encoder A PID block makes error(E) signal from the set value and process value and output manufacture value(MV) through the PID controller. In PWM block using the MV from the PID block, drives H-bridge controlling the Motor. Also DAC interface controls the DAC to graph the digital signal such as SV, PV, E, MV in FPGA onto the Oscilloscope.

  • PDF

HAUSDORFF DIMENSION OF DERANGED CANTOR SET WITHOUT SOME BOUNDEDNESS CONDITION

  • Baek, In-Soo
    • 대한수학회논문집
    • /
    • 제19권1호
    • /
    • pp.113-117
    • /
    • 2004
  • A deranged Cantor set (without the uniform bounded-ness condition away from zero of contraction ratios) whose weak local dimensions for all points coincide has its Hausdorff dimension of the same value of weak local dimension. We will show it using an energy theory instead of Frostman's density lemma which was used for the case of the deranged Cantor set with the uniform boundedness condition of contraction ratios. In the end, we will give an example of such a deranged Cantor set.

Combination of Quantitative Parameters of Shear Wave Elastography and Superb Microvascular Imaging to Evaluate Breast Masses

  • Eun Ji Lee;Yun-Woo Chang
    • Korean Journal of Radiology
    • /
    • 제21권9호
    • /
    • pp.1045-1054
    • /
    • 2020
  • Objective: This study aimed to evaluate the diagnostic value of combining the quantitative parameters of shear wave elastography (SWE) and superb microvascular imaging (SMI) to breast ultrasound (US) to differentiate between benign and malignant breast masses. Materials and Methods: A total of 200 pathologically confirmed breast lesions in 192 patients were retrospectively reviewed using breast US with B-mode imaging, SWE, and SMI. Breast masses were assessed based on the breast imaging reporting and data system (BI-RADS) and quantitative parameters using the maximum elasticity (Emax) and ratio (Eratio) in SWE and the vascular index in SMI (SMIVI). The area under the receiver operating characteristic curve (AUC) value, sensitivity, specificity, accuracy, negative predictive value, and positive predictive value of B-mode alone versus the combination of B-mode US with SWE or SMI of both parameters in differentiating between benign and malignant breast masses was compared, respectively. Hypothetical performances of selective downgrading of BI-RADS category 4a (set 1) and both upgrading of category 3 and downgrading of category 4a (set 2) were calculated. Results: Emax with a cutoff value of 86.45 kPa had the highest AUC value compared to Eratio of 3.57 or SMIVI of 3.35%. In set 1, the combination of B-mode with Emax or SMIVI had a significantly higher AUC value (0.829 and 0.778, respectively) than B-mode alone (0.719) (p < 0.001 and p = 0.047, respectively). B-mode US with the addition of Emax, Eratio, and SMIVI had the best diagnostic performance of AUC value (0.849). The accuracy and specificity increased significantly from 68.0% to 84.0% (p < 0.001) and from 46.1% to 79.1% (p < 0.001), respectively, and the sensitivity decreased from 97.6% to 90.6% without statistical loss (p = 0.199). Conclusion: Combining all quantitative values of SWE and SMI with B-mode US improved the diagnostic performance in differentiating between benign and malignant breast lesions.

Random Number Statistical Test Using fuzzy Set Operation

  • Sung-joo;Park, Jin-suk
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2002년도 추계학술대회 및 정기총회
    • /
    • pp.41-45
    • /
    • 2002
  • From the paper which it sees a strong random number generator it uses a fuzzy set from 16 method of the statistical test which is a cryptograph random number test it verifies. 16 statistical test of NIST extends in crptograph and engineering whole it is a scale which is important distinguishes the distinction incapable characterstic of the random numbers which are used. To try introduce a fuzzy set the possibility of having a more strong randomness in order to be, it strengthens the function of the random number generator.

딥러닝을 통한 콘크리트 강도에 대한 배합 방법 예측에 관한 연구 (Prediction of concrete mixing proportions using deep learning)

  • 최주희;양현민;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.30-31
    • /
    • 2021
  • This study aims to build a deep learning model that can predict the value of concrete mixing properties according to a given concrete strength value. A model was created for a total of 1,291 concrete data, including 8 characteristics related to concrete mixing elements and environment, and the compressive strength of concrete. As the deep learning model, DNN-3L-256N, which showed the best performance on the prior study, was used. The average value for each characteristic of the data set was used as the initial input value. In results, in the case of 'curing temperature', which had a narrow range of values in the existing data set, showed the lowest error rate with less than 1% error based on MAE. The highest error rate with an error of 12 to 14% for fly and bfs.

  • PDF

Meromorphic Functions with Weighted Sharing of One Set

  • Alzahary, Thamir C.
    • Kyungpook Mathematical Journal
    • /
    • 제47권1호
    • /
    • pp.57-68
    • /
    • 2007
  • In this article, we investigate the problem of uniqueness of meromorphic functions sharing one set and having deficient values, and obtain a result which improves some earlier results.

  • PDF

도시철도 자동운전 차량의 정밀정차 향상을 위한 기법 연구 (A Technique Study for Improve the Precise Position Stopping of Automatic Train Operation (ATO) Train Vehicle in Urban Railway)

  • 마상견;허대정;김명환;송재청;박준호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1049-1058
    • /
    • 2011
  • This paper suggests blending time adjusting method of braking command characteristics management and Set value test for optimizing of braking deceleration to enhance the precise position stopping. This method minimizes pneumatic-braking degree deviation by characteristics management, and secures braking stability at braking. By Set value test method, braking blending characteristics are analyzed accurately. And by optimal timing tuning at braking blending, It enhanced the precise position stopping with stabilization of deceleration To demonstrate the usefulness of these suggestion, I modeled for Deajeon Line #1. And through comparison with case of related companies, the proposed method which this paper suggested is proved to be superior to others.

  • PDF

THREE-STEP MEAN VALUE ITERATIVE SCHEME FOR VARIATIONAL INCLUSIONS AND NONEXPANSIVE MAPPINGS

  • Zhang, Fang;Su, Yongfu
    • Journal of applied mathematics & informatics
    • /
    • 제27권3_4호
    • /
    • pp.557-566
    • /
    • 2009
  • In this paper, we present the three-step mean value iterative scheme and prove that the iteration sequence converge strongly to a common element of the set of fixed points of a nonexpansive mappings and the set of the solutions of the variational inclusions under some mild conditions. The results presented in this paper extend, generalize and improve the results of Noor and Huang and some others.

  • PDF