• Title/Summary/Keyword: a probing

Search Result 679, Processing Time 0.029 seconds

A 2-Year Longitudinal Study of Untreated Periodontal Disease in Young Adults (20대의 치주염 진행에 대한 2년간의 종적연구)

  • Um, Heung-Sik
    • Journal of Periodontal and Implant Science
    • /
    • v.28 no.3
    • /
    • pp.523-531
    • /
    • 1998
  • The purpose of this investigation was to examine the pattern of progression of periodontitis and the change in the extent and severity of the periodontal condition in young adults. Fourteen subjects with periodontitis, 11 males and 3 females in the age range 22-26, participated in the study. Following a baseline examination, the subjects were monitored for gingival index, probing pocket depth, gingival recession, probing attachment level and radiogrphic crestal bone height for 24 months without therapy. Re-examination were performed after 12 and 24 months. Gingival index, probing pocket depth, gingival recession and probing attachment level were assesed at 6 locations per tooth, and crestal bone height was assessed by subtraction radiography. The results from the follow-up examination revealed that the subjects underwent minor changes with respect to a series of different clinical parameters. The mean values of gingival index was improved, however, the mean values of probing pocket depth, gingival recession, probing attchment level and crestal bone height showed no significant change between baseline and the re-examination after 1 and 2 years.

  • PDF

Contact control of a probing manipulator contacting with plastically deformable objects (소성변형가능한 물체와 접촉하는 프로브 매니퓰레이터의 접촉제어)

  • 심재홍;조형석;김성권
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.221-224
    • /
    • 1996
  • Since impact phenomenon is highly nonlinear, the analysis and control of the contact motion has been a challenging subject. Various researches have been carried out mostly for the contact of a rigid robotic manipulator with a stiff and elastic environment. This paper is motivated by a new contact task: the in-circuit test of a printed circuit board. In this process, high speed contact occurs between a rigid probing manipulator and a plastically deformable work environment. A new dynamic model of the impact controlled probing task has been proposed, considering contact with the plastically deformable object. Approaching velocity conditions to avoid an excess of the allowable penetration depth and control the generated impact force properly are derived from the proposed model. The results of the simulation studies are made for various probing conditions and show the validity of the proposed model.

  • PDF

A systematic method of probing channel characteristics of home power line communication network applied to the Internet accessed control of home appliances (인터넷 가전 제어를 위한 전력선 통신망 채널 특성 추정 기법에 관한 연구)

  • Ahn, N.H.;Chang, T.G.;Kim, H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2559-2561
    • /
    • 2002
  • This paper presents a systematic method of probing channel characteristics and communication reliabilities of home PLC (power line communication) network applied to the Internet accessed control of home appliances. The effects of the three performance deterioating factors, i.e., additive noise, channel attenuation, and intersymbol interference, can be systematically measured by applying the channel probing waveform in the frequency range from 100kHz to 450kHz. The agreement between the derived probability of bit error and the measured probability of bit error supports the validity of the proposed approach of probing home power line channel characteristics. The experimental results performed with the constructed test-bed applying the proposed channel probing method also support the feasibility of commercially deploying the PLC modem installed home appliances and their services for the Internet accessed home automation.

  • PDF

The effect of smoking on the healing response following flap debridement surgery (흡연이 치주 판막술후 치유에 미치는 영향)

  • Cho, Kyoo-Sung;Lee, Jung-Tae;Choi, Seong-Ho;Lee, Seung-Won;Chai, Jung-Kiu;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.1
    • /
    • pp.103-115
    • /
    • 1999
  • The ultimate goal of periodontal therapy is the regeneration of periodontal tissue which has been lost due to destructive periodontal disease. Various periodontal procedures have been used throughout the years in an attempt to reestablish attachment of periodontal tissues to root surfaces affected by periodontitis. Flap debridement surgery has been demonstrated to be a successful procedure in gaining the probing attachment level and reducing probing depth. A tendency towards impaired wound healing following periodontal procedures in smokers has been clinically documented. But, previous clinical studies on healing response in smokers are based on a retrospective design. The purpose of this study was to evaluate the treatment outcome following flap debridement surgery in smokers compared to nonsmokers. 25 patients with moderate to advanced periodontitis were included for study. Among these patients, 13 patients were smokers, and 12 patients were nonsmokers. Mucoperiosteal flap was raised with the sulcular incision. No antibiotic treatment was administered postsurgery. The patients was recalled at monthly intervals during a period of 6 months following the surgery. The patients were received supragingival scaling and oral hygiene reinforcement. All the recordings, including modified O' Leary plaque control record, bleeding on probing, probing pocket depth, probing attachment level,were recorded, presurgery and 6 months postsurgery. The changes of all the recordings at 6 months after flap debridement surgery revealed the following results: 1. PI on all the dentitions and surgical sites showed no statistical significance between smokers and nonsmokers at presurgery. But, smokers demonstrated a significantly lower % of PI than nonsmokers at 6 months postsurgery. 2. Smokers demonstrated a greater % of BOP sites than nonsmokers on the surgical sites and all the dentitions, presurgery and 6 months postsurgery. But, there was no statistical significance between two groups. 3. Smokers exhibited significantly less reduction of probing depth in the 3 mm or less probing pocket depth(PPD) group, 6mm or more PPD group and total PPD group when compared to nonsmokers at 6 months postsurgery. 4. Smokers exhibited significantly less gain of probing attachment level(PAL) in the 3mm or less PPD group, 6 mm or more PPD group and total PPD group when compared to nonsmokers at 6 months postsurgery.

  • PDF

A COMPARATIVE STUDY OF THE PROBING ATTACHMENT LEVEL, RADIOGRAPHIC AND SURGICAL MEASUREMENT ACCORDING TO GINGIVAL INFLAMMATORY CONDITION (치은 염증 상태에 따른 치주낭 측정 깊이와 방사선학적 측정 깊이, 외과적 측정 깊이의 비교 연구)

  • Baik, Dong-Hoon;Chai, Jung-Kiu;Cho, Kyoo-Sung;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.24 no.2
    • /
    • pp.261-270
    • /
    • 1994
  • The purpose of this study was to evaluate relationship of probing attachment levels, radiographic measurements and surgical measurements according to gingival inflammatory condition. Patients with incipient to moderate periodontitis were selected. Upper and lower premolar and molar teeth excluding third molars were measured. At first visit, gingival index and bleeding on probing were taken, and subjects were grouped into 4 categories as follows : Experimental group I : gingival index 1 and no bleeding on probing. Experimental group II : gingival index 2 and no bleeding on probing absent. Experimental group III : gingival index 1 and bleeding on probing present. Experimental group IV : gingival index 2 and bleeding on probing present. Probing attachment levels were measured with manual probe on mesial and distal surfaces from cementoenamel junctions to terminal ends of probe. Radiographic measurements were made to assess bone loss by measuring the distance from cementoenamel junction to the alveolar crest. After thorough scating, a flap was raised exposing the alveolar bone and surgical measurements were made from cementoenamel junction to alveolar bone. The results were as follows: 1. Differences between probing attachment level and radiographic measurements showed $1.01{\pm}0.73mm$ for experimental group I, $0.98{\pm}0.48mm$ for experimental group II, $0.59{\pm}0.66mm$ for experimental group III, $0.98{\pm}0.38mm$ for experimental group IV and with no significant difference between groups. 2. Differences between probing attachment level and surgical measurements showed $1.36{\pm}0.80mm$ for experimental group I, $1.47{\pm}0.54mm$ for experimental group II, $1.06{\pm}0.39mm$ for experimental group III, $1.41{\pm}0.40mm$ for experimental group IV and with no significant difference between groups. 3. Differences between surgical and radiographic measurements showed $0.36{\pm}0.48mm$ for experimental group I, $0.51{\pm}0.54mm$ for experimental group II, $0.57{\pm}0.72mm$ for experimental group III, $0.41{\pm}0.49mm$ for experimental group IV and with significant difference between experimental group I and experimental group II, III, IV(P<0.05).

  • PDF

An optical sensor of a probing system for inspection of PCBs (인쇄회로기판 검사용 프로브시스템의 광학센서)

  • 심재홍;조형석;김성권
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1742-1745
    • /
    • 1997
  • We have developed a highly responsible probing system for inspection of electrical properties of assemble PCB$_{s}$ (printed circuit boards). However, as the duration of the impact occurring between a probe and a solder joint on PCB is very short, it is very difficult to control the harmful peak impact force and the slip motion of the probe to sufficient level only by its vorce feedback control with high gains. To overcome these disadvantages of the prototype, it needs ot obtain some information of the solder joint in advance before the contact. In addition, to guarantee the reliability of the probing task, the probing system is required to measure several points around the probale target point at high speed. There fore, to meet such requirements, we propose a new noncontaet sensor capable of detecting simultaneously position and normal vectors of the multiple points around the probable target point in real time. By using this information, we can prepare a control strategy for stable contact motion on impact. In this paper, we described measuring priniciple, design, and development of the sensor. The effectiveness of the proposed sensor is verified through a series of experiments.s.

  • PDF

An Inference Method of Stateless Firewall Policy Considering Attack Detection Threshold (공격 탐지 임계값을 고려한 비상태기반 방화벽 정책 추론 방법)

  • Kim, Hyeonwoo;Kwon, Dongwoo;Ju, Hongtaek
    • Journal of Internet Computing and Services
    • /
    • v.16 no.2
    • /
    • pp.27-40
    • /
    • 2015
  • Inferring firewall policy is to discover firewall policy by analyzing response packets as results of active probing without any prior information. However, a brute-force approach for generating probing packets is unavailable because the probing packets may be regarded as attack traffic and blocked by attack detection threshold of a firewall. In this paper, we propose a firewall policy inference method using an efficient probing algorithm which considers the number of source IP addresses, maximum probing packets per second and interval size of adjacent sweep lines as inference parameters to avoid detection. We then verify whether the generated probing packets are classified as network attack patterns by a firewall, and present the result of evaluation of the correctness by comparing original firewall policy with inferred firewall policy.

A Fine Manipulator with Compliance for Wafer Probing System (컴플라이언스를 갖는 웨이퍼 탐침 시스템용 미동 매니퓰레이터)

  • Choi, Kee-Bong;Kim, Soo-Hyun;Kwak, Yoon Keun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.9
    • /
    • pp.68-79
    • /
    • 1997
  • A six DOF fine manipulator based on magnetic levitation is developed. Since most of magnetic levitation system are inherently unstable, a proposed magnetically levitated fine manipulator is implemented by use of an antagonistic structure to increase stability. From mathematical modeling and experiment, the equations of motion are derived. In addition, a six DOF sensing system is implemented by use of three 2-axis PSD sensors. A model reference-$H_{\infty}$ controller is applied to the system for the position control, In application of the fine manipulator, a wafer probing system is proposed to identify nonfunctional circuts. The probing system requires compliance to avoid destruction of DUT(device under test). A feedfor- ward-PD controllers are presented by the terms of the position accuracy, the settling time and the force accuracy.y.

  • PDF

Wound Probing in Neck Trauma Patients (경부 손상 환자에서의 상처 탐침)

  • Ye, Jin Bong;Sul, Young Hoon;Mun, Yun Su;Go, Seung Je;Kwon, Oh Sang;Ku, Gwan Woo;Lee, Min Koo
    • Journal of Trauma and Injury
    • /
    • v.28 no.3
    • /
    • pp.198-201
    • /
    • 2015
  • Neck trauma is a relatively uncommon but can be a life-threatening injury. Several guidelines for neck trauma is established to recommend a proper management such as no clamping of bleeding vessels, no probing of wounds, Trendelenberg position for preventing venous air embolism. Here, we present a regretful case of 49-year-old man with neck trauma presenting undesired bleeding after probing of wound, and then discuss about treatment guildeline for neck trauma with a review.

  • PDF