• Title/Summary/Keyword: a noise

Search Result 24,637, Processing Time 0.052 seconds

A Case Study for Analysis on Present Condition and Cause of Indoor Noise in University Cafeteria (대학교 학생식당의 실내소음 실태 및 원인 분석 사례연구)

  • Choi, Yoon-Jung;Lee, Seon-A;Kim, Hye-Kyeong
    • Journal of the Korean housing association
    • /
    • v.18 no.5
    • /
    • pp.85-91
    • /
    • 2007
  • This is a case study for improving the sound environmental quality of cafeteria in university campus. The purpose of the study is to find out the present condition of physical level, type, and cause of indoor noise of cafeteria in university campus by comparison with a restaurant near campus. Research methods were field survey and questionnaire survey. Field survey was consisted of measurement on equivalent and instant noise level and observation on noise type. Respondents of questionnaire survey were 60 students using subject cafeteria or restaurant. Surveys were carried out in the 8th and in the 14th of December 2005. The results are as follows. 1) Indoor noise levels of the cafeteria were measured as $67.2{\sim}76.6$ (average 73.3) dB(A)Leq5min and $60.3{\sim}90.5$ (average 71.2) dB (A), exceeded the indoor noise recommended value of ASHRAE (American Society of Heating, Refrigerating and Air Conditioning Engineers). But noise levels of the restaurant were $61.6{\sim}70.4$ (average 66.9) dB(A)Leq5min and $59.8{\sim}70.6$ (average 64.9) dB(A). 2) The users's responses on major noise type in the cafeteria were 'noise by handling equipment and tableware', 'noise by moving chairs', and 'talcing noise', but 'taking noise' and 'background music' in the restaurant. 3) It was found that indoor noise level of the cafeteria was caused by sound reflection of finishing materials, noise diffusion by open type kitchen, and dragging noise of movable furniture.

An Investigation of the Noise in Ship Engine-Room and Cabins for Hearing Protection (I) (청력보호를 위한 선박 기관실 및 선실소음의 조사(I))

  • Yu, Y.H.
    • Journal of Power System Engineering
    • /
    • v.3 no.3
    • /
    • pp.97-103
    • /
    • 1999
  • As the noise of ship engine room is too loud, the engineer who works in a ship engine-room has the trouble of hearing. In this paper deals the investigation of the noise of ship engine room and cabins with the internationally allowable noise exposure level and noise exposure time. Recently, the problem of engine-room noise is more serious because of shipowner wants to make small number and larger size of cylinder. Therefore, engineers work in a ship engine-room for a long time have the trouble of hearing when they are exposed the high noise level. In this study, two kinds of vessels were used to investigate the noise of engine room, engine-control room, bridge, offices and cabins. As criteria of sound levels, A-weighted sound pressure level and octave band pressure level were used.

  • PDF

A Study on Transfer Characteristics of Vehicle Air-conditioner Booming noise (차량용 에어컨 부밍 소음의 전달 특성에 관한 연구)

  • Lim, Seung Taek;Joo, Kyung Hoon;Ahn, Hew Nam;Park, Young Duk;Kang, Yean Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.476-481
    • /
    • 2013
  • Transfer path analysis(TPA) and operational deflection shape(ODS) have been widely utilized to analyze the characteristics of noise. TPA enables to decompose a noise into air-borne and structure-borne noises then estimate the path contribution of noise. ODS enables to analyze a moving shape and direction of interest components at a particular frequency. In this paper, TPA and ODS are applied to transfer paths of air-conditioner booming noise in a vehicle to reduce noise level, then a fixture is mounted it's path for distributing the high portion path contribution to the low portion path contribution. Through this experiment, the reduction of sound pressure level in air-conditioner booming noise is observed. Thereafter, TPA is again employed to verify the results of contribution.

  • PDF

Improvement of Noise Performance in Phased-Array Receivers

  • Kim, Jung-Hyun;Jeong, Jin-Ho;Jeon, Sang-Geun
    • ETRI Journal
    • /
    • v.33 no.2
    • /
    • pp.176-183
    • /
    • 2011
  • This paper presents a new analytical approach and experimental verification for the improvement of noise performance in phased-array receivers. For analysis purposes, a multi-channel array system is converted into an equivalent single-channel system, such that the two presents the identical signal and noise powers at the output, respectively. We define an effective gain, noise figure, and signal-to-noise ratio in the equivalent system. Through the proposed approach, the noise performance of the array receiver is analyzed in a general and straightforward manner and then compared to that of each individual array channel. In addition, the phase noise of the array system is analyzed in a rigorous manner, showing its effective reduction by a factor of the array size. The predicted improvement of the noise performance is experimentally confirmed with a CMOS integrated phased-array receiver.

A Study on the Residents' Attitudes and Adaptation Behavior of Indoor Noise in Apartment Houses (아파트 내부소음에 대한 거주자 태도 및 적응행위에 관한 연구)

  • 윤복자
    • Journal of the Korean Home Economics Association
    • /
    • v.27 no.1
    • /
    • pp.85-96
    • /
    • 1989
  • The purpose of study was to survey the indoor noise of apartment houses, residents, attitudes and their adaptation behavior in order to offer the information helpful to apartment designers and residents, in their housing policy. Documentary research and questionnaire survey methods were used in this research. The sample was taken from 187 housewives living in apartments in Seoul. Data were analyzed with the SPSS program. The results were as follow : 1. It was found that apartment residents pointed out washing machine noise inside the home, piano and other musical instruments noise outside the home. 2. Piano and other musical instrument noise were heard at 3 to 6 pp.m. when residents heard the noise, and water supply and drainage noise in bathrooms were found most noisy. 3. Apartment residents were discontent with noise outside the home, and they displayed positive adaptation behavior at a reduced noise level. 4. Attitudes arising from indoor noise in apartment houses and human noise, water supply and drainage noise, doorway opening and closing noise were found to be significant in sampled apartment groups. 5. The youngest child's age was a significant variable on the residents' attitudes and adaptation behavior of indoor noise in apartment houses. 6. Between the resident' attitudes and adaptation behavior involving indoor noise in apartment houses. 6. Between the resident' attitueds and adaptation behavior involving indoor noise apartment houses, the more they became discontented, the more quickly they adapted in a postive manner.

  • PDF

Noise Pollution and the Perception of Noise in Seoul (서울시 소음공해 현황과 이에 대한 주민의 인식정도)

  • 정인희;이효수
    • Journal of Environmental Science International
    • /
    • v.6 no.6
    • /
    • pp.551-562
    • /
    • 1997
  • Nine districts in Seoul were chosen randomly and a questionnaire containing 23 questions was distributed to survey the perception of noise pollution by the citizens. The results were primarily analyzed to understand the perception of Seoul citizen as a whole, and then analyzed according to 4 demographic variables -district area, age, gender and occupation -to see if there were any possible relation between nonnoise variables and noise annoyance. Actual noise level data measured by the city government were used to compare quantified noise level with the surveyed people's perception. It was found that people consider road traffic noise to be the naix source of noise pollution In Seoul and that most people have experienced annoyance in everyday life. Also it was verified that the responsibility for noise control should be on both city government and the individuals, but It was generally considered that very little effort Is actually put Into solong norse pollution from both groups. From the survey, It could be analyzed that domographic variables do affect people In the awareness of noise pollution, and that one's sensitifty and annoyance due to noise increase as one ages. From the study, It was concluded that noise pollution Is not considered currently as a hazardous problem to most Seoul citizens, however specific noise reduction policies, especially regarding road traffic noise, should be put Into practice In the near future.

  • PDF

Task-specific Noise Exposure Assessment of Firefighters

  • Kang, Taesun
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.6
    • /
    • pp.569-576
    • /
    • 2019
  • Objectives: The main purpose of this study was to assess firefighters' daily personal noise exposure and explore noise levels related to specific tasks and their contributions to total noise exposure using 24-hour full-shift noise exposure measurements with task-based data. Methods: Noise exposure was assessed for eight firefighters (two rescuers, two drivers, and four suppressors) using time-activity diaries. We collected a total of 24 full-shift personal noise sample sets (three samples per a firefighter). The 24-hour shift-adjusted daily personal noise exposure level (Lep,d), eight weekly personal noise exposures (Leq,w), and 40 task-specific Leq values (Leq activity) were calculated via the ISO/NIOSH method. Results: The firefighter noise-sample datasets showed that most firefighters are exposed to noise levels above EU recommended levels at a low-action value. The highest noise exposure was for rescuers, followed by drivers and suppressors. Noise measurements with time-at-task information revealed that 82.3% of noise exposure occurred when checking equipment and responding to fire or emergency calls. Conclusions: The results indicate that firefighters are at risk of noise-induced hearing loss. Therefore, efforts at noise-control are necessary for their protection. This task-specific noise exposure assessment also shows that protective measures should be focused on certain tasks, such as checking and testing equipment.

Noise Reduction Effect of an Air Bubble Layer on an Infinite Flat Plate Considering the Noise of Multi-bubbles (다중기포 발생소음을 고려한 무한평판 주위에 형성된 수중 기포층의 방사소음 감소 효과)

  • Kim, Jong-Chul;Heo, Bo-Hyun;Cho, Dae-Seung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.11
    • /
    • pp.1222-1230
    • /
    • 2009
  • A theoretical model was developed to compute the effect of a bubble layer in reducing the radiation noise generated by a force applied on an infinite flat plate considering the noise of multi-bubbles. Using the model, the effectiveness of a bubble layer in reducing the structure-borne noise of the plate was evaluated to consider various parameters such as the source noise levels, the thickness of bubble layers, the volume fractions and the frequency characteristics of bubbly fluids. Considering the noise of multi-bubbles, the actual reduction effect of radiation noise using a bubble layer was expected in cases of high source levels, high volume fractions of bubbles and large thickness of the bubble layer above the resonance frequency of the bubble layer. Accordingly, it is recommended that the thickness of a bubble layer, the source noise level and the characteristics of bubbly fluids should be optimized cautiously to maximize noise reduction effects.

Two-Microphone Binary Mask Speech Enhancement in Diffuse and Directional Noise Fields

  • Abdipour, Roohollah;Akbari, Ahmad;Rahmani, Mohsen
    • ETRI Journal
    • /
    • v.36 no.5
    • /
    • pp.772-782
    • /
    • 2014
  • Two-microphone binary mask speech enhancement (2mBMSE) has been of particular interest in recent literature and has shown promising results. Current 2mBMSE systems rely on spatial cues of speech and noise sources. Although these cues are helpful for directional noise sources, they lose their efficiency in diffuse noise fields. We propose a new system that is effective in both directional and diffuse noise conditions. The system exploits two features. The first determines whether a given time-frequency (T-F) unit of the input spectrum is dominated by a diffuse or directional source. A diffuse signal is certainly a noise signal, but a directional signal could correspond to a noise or speech source. The second feature discriminates between T-F units dominated by speech or directional noise signals. Speech enhancement is performed using a binary mask, calculated based on the proposed features. In both directional and diffuse noise fields, the proposed system segregates speech T-F units with hit rates above 85%. It outperforms previous solutions in terms of signal-to-noise ratio and perceptual evaluation of speech quality improvement, especially in diffuse noise conditions.

Criteria for multiple noises in residential buildings uslng combined rating system (공동주택 생활소음의 통합 평가등급 설정)

  • Ryu, Jong-Kwan;Lee, Pyoung-Jik;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.367-371
    • /
    • 2005
  • Social noise survey on multiple residential noises such as nut impact, air-borne, bathroom, drainage and traffic noises was conducted to investigate major variables affecting the overall satisfaction for noise environment The effect of individual noise perception on the evaluation of the overall noise environment was investigated through a questionnaire survey on annoyance, disturbance and noise sensitivity. Auditory experiments was also undertaken to determine noise level according to the percent of satisfaction for individual noise source. As a result of survey, it was found that satisfaction for floor impact noise most greatly affects the overall satisfaction for noise environment and annoyance most greatly affects the satisfaction for individual noise sources. Result of auditory experiment showed that the noise level of floor impact noise by bang machine, airborne, drainage and traffic noise corresponding to 50% satisfaction is 44dB($L_{i,Fmax,AW}$) and 40dBA, respectively.

  • PDF