• Title/Summary/Keyword: a lower temperature

Search Result 7,560, Processing Time 0.037 seconds

An Effect of the 2nd Land Length of a Piston on Thermal Stress (피스톤의 제2랜드 길이가 열응력에 미치는 영향)

  • Kwon, Y.W.;Park, S.C.
    • Journal of Power System Engineering
    • /
    • v.12 no.2
    • /
    • pp.5-11
    • /
    • 2008
  • An analytical study was performed to have temperature and thermal stress distribution on a piston with the change of the 2nd land length of a piston and the existence of knocking in a cylinder. The result showed that the temperature on the skirt region was about $4\sim10^{\circ}C$ higher than that on the pin region. However the thermal stress on the skirt region was about 4MPa lower than on the pin region. It may be due to the higher heat release rate on the pin boss than on the skirt. The result regarding the variation of the 2nd land length of the piston showed that the temperature distribution on the piston was getting lower and the thermal stress distribution was getting higher as the 2nd land length of the piston was shorter.

  • PDF

A Study on the Thermal Stress Analysis of a Piston in a Turbocharged Diesel Engine (터보 디젤엔진 피스톤의 열응력 해석에 관한 연구)

  • 국종영
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.2
    • /
    • pp.92-98
    • /
    • 2001
  • We determined the transfer coefficient through the analysis of three dimensional temperature distribution in comparison with the measured temperature on the piston in the turbocharged diesel engine. And we analyzed the thermal stress and the thermal deformation with that heat transfer coefficient by using finite element method. According to this results, we found that maximum tempetature range of the piston appeared at the upper part of the piston crown and that the heat transfer coefficient of the upper part of the piston is smaller than that of the lower one. It showed that the maximum thermal deformation is shown at the edge of the upper part of piston and that the maximum thermal stress was shown on the lower part of the piston crown. Finally, we defined the method of determination of a piston heat transfer analysis by using measured temperature on the piston and analyzed temperature with finite element method.

  • PDF

A Semi-Interpenetrating Network for Temperature-Sensitive Polymer System

  • Yuk, Soon-Hong;Cho, Sun-Hang
    • Macromolecular Research
    • /
    • v.8 no.2
    • /
    • pp.89-94
    • /
    • 2000
  • A semi-interpenetrating network (IPN) was prepared for a temperature-sensitive polymer system composed of sodium alginate and poly (N, N-dimethylaminoethyl methacrylate (DMAEMA)-co-ethyl acrylamide (EAAm)). The role of sodium alginate is to provide crosslinked network and that of poly(DMAEMA-co-EAAm) is to provide temperature responsiveness to the polymer system. Semi-IPN gel shows temperature-induced swelling transition at the same temperature of the lower critical solution temperature of poly(DMAEMA-co-EAAm) and its swelling kinetics is manipulated by the control of crosslinking densitv.

  • PDF

Influence of Water Temperature During the Main Spawning Period on Anchovy Catch (멸치의 산란기 수온이 어획량에 미치는 영향)

  • Lee, Chung-Il;Jang, Lee-Hyun;Park, Sung-Eun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.42 no.3
    • /
    • pp.297-301
    • /
    • 2009
  • The water temperature from 1980 to 2000 and the anchovy catch from 1990 to 2000 in the southeastern portion of the South Sea of Korea were used to illustrate the influence of water temperature on the catch of the anchovy, Engraulis japonica. 1993 and 1998 were selected as poor and good fishing years therefore, the horizontal and vertical distribution of water temperature and catch per unit effort in these years was compared. When the anchovy catch was lower, the water temperature at 10 m was also about $0-2^{\circ}C$ lower than during a normal year, which resulted in the formation of a weak thermocline. Conversely, when the anchovy catch was higher, the water temperature at 10m was $0-2^{\circ}C$ greater than during a normal year, which resulted in the formation of a strong thermocline at around 20 m.

The clinical study of Digital Infrared Thermographic Imaging on Hwa-byung(火病) patients (전신체열촬영(全身體熱撮影)에 의한 화병환자(火病患者)의 임상적(臨床的) 연구(硏究))

  • Kim Tae-Heon;Lyu Yeoung-Su
    • Journal of Oriental Neuropsychiatry
    • /
    • v.10 no.1
    • /
    • pp.133-146
    • /
    • 1999
  • First I chose a patient group and a comparative group composed of 23 members each. Then the body temperature differences in these groups was taken with D.I.T.I. The results are as follows. 1. Average body temperature of the Hwa-Byung patient group is $36.6^{\circ}C$ and that of the comparative group is $36.4^{\circ}C$. So there is no meaningful body temperature difference. 2. The hwa-Byung patient group has higher temperature than the comparative group by ${\triangle}T>1.0^{\circ}C$ at the following acupunture points in these body parts upper and lower, left and right, anterior and posterior, trunk and limb. Especially, the body temperature difference was clear in the CV-17 (jun-Joong) and the GV-4(Myung-moon). 3. When the body temperature was compared in the upper and lower part of the back, it had meaningful differences at the upper and lower acupunture points of the back in the Hwa-Byung patient group but not in the comparative group. 4. When the body temperature was compared in the left and right part of the body, its average difference was ${\triangle}T>1.0^{\circ}C$ in the two groups and the result were meaningless. 5. When body temperature was compared in the anterior and posterior part of the body, its average difference was ${\triangle}T>1.0^{\circ}C$ in the two groups and the result were meaningless. 6. When body temperature was compared in the trunk and limb part of the body, its difference in the patient group was meaningful compared with the non-patient group. From the above results, I think that D.I.T.I. could be used to objectively visualize heat sensation of the Hwa-Byung patients and make an objective concept of Han Yul in oriental medicine.

  • PDF

Mitigating the Urban Heat Island Phenomenon Using a Water-Retentive Artificial Turf System

  • Tebakari, Taichi;Maruyama, Tatsuya;Inui, Masahiro
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.91-100
    • /
    • 2010
  • To investigate the thermal properties of a water-retentive artificial turf system (W-ATS), we estimated hydrologic parameters including thermal conductivity, heat capacity, and surface albedo for both the W-ATS and natural grass. We used a model experiment to measure surface temperature and evaporation for both the W-ATS and natural grass. We found that the W-ATS had lower thermal conductivity than natural grass did, and it was difficult for the W-ATS to convey radiant heat to the ground. Compared to natural grass, the W-ATS also had lower heat capacity, which contributed to its larger variation in surface temperature: the W-ATS had higher surface temperatures during daytime and lower surface temperatures during nighttime. The albedo of the W-ATS was one-quarter that of natural grass, and reflected shortwave radiation from the W-ATS surface was lower than that from the surface of natural grass. These results indicate that the W-ATS caused the soil temperature to increase. Furthermore, evaporation from the W-ATS was one-quarter the value of evapotranspiration from natural grass.

  • PDF

Prediction of Temperature Dependence of Explosion Limits and Interrelationship of Explosion Characteristics for Akylketones (알킬케톤류의 폭발 특성치 간의 상관관계 및 폭발한계의 온도의존성 예측)

  • Ha Dong-Myeong
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.2 s.31
    • /
    • pp.7-13
    • /
    • 2006
  • In order to evaluate the fire and explosion involved and to ensure the safe and optimized operation of chemical processes, it is necessary to know combustion characteristics. The explosion limit, the heat of combustion, flame temperature and temperature dependence of the lower explosive limit are the major combustion characteristics used to determine the fire and explosion hazards of the flammable substances. The aim of this study is to investigate interrelationship of explosion characteristics and the temperature dependence of the lower explosion limit at elevated temperature for akylketones. By using the reference data, the empirical equations which describe the interrelationships of explosion properties of akylketones have been derived. Also, the new equations using the mathematical and statistical methods for predicting the temperature dependence of lower explosion limits of akylketones on the basis of the literature data are proposed. The values calculated by the proposed equations agreed with literature data within a few percent. From the given results, using the proposed methodology, it is possible to predict the explosion limits of the other flammable substances.

  • PDF

Reduction in Indoor and Outdoor Temperature of Office Building with Cool Roof (쿨루프 적용에 따른 업무용 건물의 내·외부 온도 저감 효과)

  • Song, Bong-Geun;Kim, Gyeong-Ah;Park, Kyung-Hun
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.95-101
    • /
    • 2016
  • Purpose: This study aims to identify the effect of temperature reduction by the application of cool roof coatings to Changwon City Hall in South Gyeongsang Province. The indoor and outdoor temperatures of the cool roofing building were analyzed and compared to that of an existing building with green-colored roof coated with waterproof polyurethane. Method: The surface temperatures and reflectivity of rooftops, surface temperatures of ceilings and the interior, and outdoor temperature and humidity of the two aforementioned buildings were measured from June to September in 2014. The measurements were taken every 10 min. Result: The surface temperature of the building with the cool roof was lower by a maximum of $9^{\circ}C$ with the reflectivity of the rooftop at an average of 0.55, which is higher than that of the building with green polyurethane by approximately 0.3. The temperature of the ceiling inside the building with the cool roof was about $1{\sim}2^{\circ}C$ lower than that of the ordinary building. Also, the indoor temperature of the office with cool roof coatings was about $0.5{\sim}1.0^{\circ}C$ lower than that of the office with green-colored roofing building. The results show that cool roof coatings can lower the temperature of buildings. In the next research, the reduction in consumption of energy for air conditioning will be investigated by utilizing building energy simulation tools.

Rheological Behavior of Semi-Solid Ointment Base (Vaseline) in Steady Shear Flow Fields (정상전단유동장에서 반고형 연고기제(바셀린)의 레올로지 거동)

  • Song, Ki-Won;Kim, Yoon-Jeong;Lee, Chi-Ho
    • Journal of Pharmaceutical Investigation
    • /
    • v.37 no.3
    • /
    • pp.137-148
    • /
    • 2007
  • Using a strain-controlled rheometer [Rheometrics Dynamic Analyzer (RDA II)], the steady shear flow properties of a semi-solid ointment base (vaseline) have been measured over a wide range of shear rates at temperature range of $25{\sim}60^{\circ}C$. In this article, the steady shear flow properties (shear stress, steady shear viscosity and yield stress) were reported from the experimentally obtained data and the effects of shear rate as well as temperature on these properties were discussed in detail. In addition, several inelastic-viscoplastic flow models including a yield stress parameter were employed to make a quantitative evaluation of the steady shear flow behavior, and then the applicability of these models was examined by calculating the various material parameters (yield stress, consistency index and flow behavior index). Main findings obtained from this study can be summarized as follows : (1) At temperature range lower than $40^{\circ}C$, vaseline is regarded as a viscoplastic material having a finite magnitude of yield stress and its flow behavior beyond a yield stress shows a shear-thinning (or pseudo-plastic) feature, indicating a decrease in steady shear viscosity as an increase in shear rate. At this temperature range, the flow curve of vaseline has two inflection points and the first inflection point occurring at relatively lower shear rate corresponds to a static yield stress. The static yield stress of vaseline is decreased with increasing temperature and takes place at a lower shear rate, due to a progressive breakdown of three dimensional network structure. (2) At temperature range higher than $45^{\circ}C$, vaseline becomes a viscous liquid with no yield stress and its flow character exhibits a Newtonian behavior, demonstrating a constant steady shear viscosity regardless of an increase in shear rate. With increasing temperature, vaseline begins to show a Newtonian behavior at a lower shear rate range, indicating that the microcrystalline structure is completely destroyed due to a synergic effect of high temperature and shear deformation. (3) Over a whole range of temperatures tested, the Herschel-Bulkley, Mizrahi-Berk, and Heinz-Casson models are all applicable and have an almostly equivalent ability to quantitatively describe the steady shear flow behavior of vaseline, whereas the Bingham, Casson,and Vocadlo models do not give a good ability.

The Effects of Physical Aging of PSF/AS4 Laminate on Fatigue (PSE/AS4 복합재료의 가속노화가 피로강도에 미치는 영향)

  • Kim, Hyung-Won
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.11a
    • /
    • pp.39-44
    • /
    • 2005
  • The effects of aging of PSF/AS4 laminates on fatigue was studied using the new energy release rate analysis. The analysis by the variational mechanics has been useful in providing fracture mechanics interpretation of matrix microcracking in cross-ply laminates. This paper describes the changes of the critical energy release rate (microcracking toughness) according to the aging period under fatigue loading. The master plot by modified Paris-law gives a characterization of a material system's resistance to microcrack formation. PSF $[0/90_{s}]_{s}$ laminates were aged at four different temperature based on the glass transition temperature for 0 to 60 days. At all temperatures, the toughness decreased with aging time. The decrease of the toughness at higher temperature was faster than at lower temperature. To assess the effects of aging on fatigue, the unaged laminates were compared with the laminates which had been aged for 60 days at 170$^{\circ}C$ near 180 $^{\circ}C$ t$_g$. The slope of dD/dN versus ${\Delta}G_m$. of the aged laminates was lower than that of the unaged laminates. There was a significant shift of the aged data to formation of microcracks at the lower values of ${\Delta}G_m$.

  • PDF