• 제목/요약/키워드: a hydraulic system

검색결과 2,695건 처리시간 0.032초

유압모터-부하계의 3D CAD 모델링 및 적응제어 (3D CAD Modeling of a Hydraulic Motor-Load System and Adaptive Control)

  • 조승호
    • 유공압시스템학회논문집
    • /
    • 제8권2호
    • /
    • pp.23-28
    • /
    • 2011
  • This paper investigates the motion control of a hydraulic motor-load system using the Simple Adaptive Control (SAC) method. The plant transfer function has been modelled mathematically. The open-loop responses have been obtained experimentally in order to identify the design parameters of transfer function. The hydraulic motor-load system has been modelled using the 3D CAD and imbedded in the hydraulic circuit simulation program to verify the overall performance. The experimental results confirm that the SAC method gives a good tracking performance compared to the PID control.

중대형 굴삭기 유압시스템의 압력 맥동 저감 연구 (A Study on the Pulsation Pressure Reduction for the Hydraulic System of Medium-Large Excavator)

  • 김영현;주원호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 추계학술대회 논문집
    • /
    • pp.421-426
    • /
    • 2010
  • With hydraulic noise test facility, a variety of tests were performed to investigate the pulsation pressure generation mechanism and its transmission characteristics and to derive the noise control methodology. Many experiments were carried out by changing average pressure, flow rate, pump speed, hose length and MCV spool condition. From the test results, the correlations between pulsation pressure and other design parameters, such as static pressure, flow rate and MCV spool opening area and length of hose, were found out. And also each contribution factors were evaluated from the regression analysis. By changing hose length, the pulsation pressure resonance phenomenon was investigated. In order to find out the pulsation pressure reduction measures pulsation pressure analysis, such as pulsation pressure of hydraulic pump itself and pulsation pressure of hydraulic system, by using AMESim were studied. In addition hydraulic silencer was developed based on the Helmholtz resonator. And its performance was evaluated by installing the silencer at the excavator.

  • PDF

유도무기용 날개구동기의 동적 강성 측정을 위한 유압 구동장치의 토크제어 기법에 관한 연구 (A Study on the Torque Control Method of a Hydraulic Actuation System for Measuring the Dynamic Stiffness of Missile Fin Actuators)

  • 이호성
    • 한국군사과학기술학회지
    • /
    • 제10권3호
    • /
    • pp.181-188
    • /
    • 2007
  • This paper presents a torque control method of a hydraulic actuation system for measuring the dynamic stiffness of missile fin actuators. We propose a new control technique called Dual Dynamic Torque Feedback Control(DDTFC), which improves the stability of the torque control system and enables fast tracking of torque command. The developed control scheme is derived from the physical understanding based on mathematical modelling and analysis. The dynamics of hydraulic torque control servo-system is unravelled via physics-based modelling and nonparametric system identification. In order to verify the effectiveness of the method, the experiment is carried out with a test equipment for measuring the dynamic stiffness. The experiment and simulation results show that DDTFC gives stability improvement.

유압펌프용 SRM 구동 시스템의 특성해석 (Characteristics Analysis of SRM Drive System for Hydraulic Pump)

  • 이주현;김봉철;김태형;안진우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.83-86
    • /
    • 2005
  • This paper proposed a hydraulic pump system which uses a variable SR drive and constant capacity pump. The base and maximum speed, torque are determined from displacement capacity of the pump and maximum pressure. The drive system is set to have a minimum power consumption having hydraulic preset pressure, which is operated within a maximum capacity and maximum preset pressure. This is achieved by controlling motor speed and power with feedback signal of pressure of the hydraulic pump. A 2.2kw, 12/8-pole SR motor and DSP based digital controller are designed and prototype drive system is manufactured. The proposed variable speed SR drive system is simulated and tested with experimental set-up. The test results show that the system has some good features such as high efficiency and high response characteristics.

  • PDF

유압 트랜스포머를 이용한 유압 실린더의 에너지 절감에 관한 연구 (A Study on Energy Saving Hydraulic Cylinder System Using Hydraulic Transformer)

  • 이민수;조용래;윤홍수;안경관
    • 한국정밀공학회지
    • /
    • 제25권2호
    • /
    • pp.49-56
    • /
    • 2008
  • In order to reduce energy consumption, secondary controlled system has been applied to many types of equipments. In lifting equipments or press machines using hydraulic cylinder, a hydraulic transformer is used as a control component instead of a valve for motion control and a component for recovering potential energy of load. The transformer is a combination of a variable displacement pump/motor as a secondary controlled element and a fixed displacement pump/motor. In this paper the effect of transformer is studied. Multiple closed loop controllers with displacement feedback of variable pump/motor, speed feedback and position feedback of cylinder are used. The efficiency and energy consumption when cylinder is driven up and down is calculated by simulation. Simulation results show that considerable energy saving is achieved by choosing load ratio, circuit type and supply pressure.

전기.유압펌프 시스템의 설계 및 제어에 관한 연구 (A Study on Design and Control of Electro-Hydraulic Pump System)

  • 박성환;하석홍;이진걸
    • 대한기계학회논문집
    • /
    • 제19권4호
    • /
    • pp.1062-1070
    • /
    • 1995
  • The study deals with controlling the velocity of hydraulic motor with PI controller through the control of displacement pump which has higher efficiency than valve-controlled system. This was done as follows. First, we modified original displacement pump and designed this electrohydraulic puma system. Second, after experimenting static and dynamic characteristics, we identified system parameter of approximated model. Lastly, to control the velocity of hydraulic motor we controlled the angle of the swash plate of displacement pump. Test carried out in the laboratory shows that transient and steady state response could be improved by PI controller reducing power loss.

전기 유압 서어보 시스템의 비표준 PID 제어에 관한 연구 (A study on the non-standard PID control for electro-hydraulic servo system)

  • 이용주;송창섭
    • 한국정밀공학회지
    • /
    • 제14권11호
    • /
    • pp.25-33
    • /
    • 1997
  • This study deals with controlling the velocity of Electr-Hydraulic servo system through the non-stan-dard PIC control. This was done as follows. First, we modeled nonlinearised model and linearised model, second designed analytic program for electro-hydraulic servo system velocity control Lastly, to im- prove dynamic characteristics of system we designed non-standard PID contoller and verifed throughth experi- ment and MATLAB program, commercial used software.

  • PDF

REDUCTION OF PRESSURE RIPPLES USING A PARALLEL LINE IN HYDRAULIC PIPELINE

  • KIM K. H.;JANG J. S.;JUNG D. S.;KIM H. E.
    • International Journal of Automotive Technology
    • /
    • 제6권1호
    • /
    • pp.65-70
    • /
    • 2005
  • Pressure ripples, which are inevitably generated by a fluctuation of flow rate caused by a pump mechanism, include noises and vibrations in hydraulic pipeline. These noises and vibration deteriorate the stability and accuracy of hydraulic systems. The accumulator and hydraulic attenuator are normally used to reduce the pressure ripples. In this study, a parallel line is introduced to the hydraulic pipeline for the hydraulic system with a bent-axis piston pump as a method to reduce the pressure ripples. The dynamic characteristics of the hydraulic pipeline with a parallel line are analyzed by a transfer matrix in the frequency domain. The usefulness of the hydraulic pipeline with a parallel line was ascertained by experiment and simulation. The results from the experiment and simulation show that the hydraulic pipeline with a parallel line were effective in reducing the pressure ripples.

유압 트랜스포머를 이용한 에너지 절감형 유압시스템에 관한 기초연구 (A study on Energy Saving Hydraulic System Using Hydraulic Transformer)

  • 이민수;안경관;조용래;조우근
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.917-922
    • /
    • 2008
  • In order to reduce energy consumption, secondary controlled system has been applied to many types of equipments. In lifting equipments or press machines using hydraulic cylinder, a hydraulic transformer is used as a control component instead of a valve for motion control and a component for recovering potential energy of load. The transformer is combination of a variable displacement pump/motor as a secondary controlled element and a fixed displacement pump/motor. Based on the nominal model derived from mathematical model, the feedback type two-degree-of-freedom controller is designed and implemented. From simulation results, the disturbances including nonlinear friction torque, leakage flow and load force can be compensated and good positioning accuracy is obtained. It show that the proposed controller is effective.

  • PDF