• Title/Summary/Keyword: a frequency response

Search Result 4,827, Processing Time 0.032 seconds

Image Enhancement of Simplified Ultrasonic CT Using Frequency Analysis Method

  • Kim, kyung-Cho;Hiroaki Fukuhara;Hisashi Yamawaki
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.12
    • /
    • pp.1627-1632
    • /
    • 2002
  • In this paper, a simplified ultrasonic CT system, which uses the information in three directions, that is, 90°, +45° and -45°about the inspection plane, is applied to the high strength steel, and the frequency analysis method for enhancing the C scan or CT image is developed. This frequency analysis method is based on the frequency response property of the material. By comparing the magnitudes in the frequency domain, the special frequency which shows a significant difference between the welded joint and base material was found and used to obtain a C scan or CT image. Experimental results for several kinds of specimens, having a welded joint by electron beam welding, a weld joint by arc welding, on a fatigue crack, showed that the obtained C scan or CT image has better resolution than the results of previous experiments using the maximum value of the received waveform.

Analysis of Dynamic Characteristics of High Speed Trains Using a Time Varying Frequency Transform (시간-주파수 변환을 이용한 고속철도차량의 동특성 분석)

  • Lee, Jun-Seok;Choi, Sung-Hoon;Kim, Sang-Soo;Park, Choon-Soo
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.841-848
    • /
    • 2008
  • This paper examined dynamic characteristics of high speed trains using a time varying frequency transform. Fourier transform based methods are frequently used for the calculation of the dynamic characteristics of trains in the frequency domain, but they cannot represent the time-varying characteristics. Therefore it is necessary to examine their characteristics using a time-varying frequency transform. For the examination, the non-stationary vibration of wheelset, bogie, and carbody are measured using accelerometers and stored in a data aquisition system. They are processed with localization of the data by modulating with a window function, and Fourier transform is taken to each localized data, called the short-time Fourier transform. From the processed results, time varying auto-spectral density, cross-spectral density, frequency response, and coherence functions have been calculated. From the analysis, it is confirmed that the time varying frequency transform is a useful method for analyzing the dynamic characteristics of high speed trains.

  • PDF

Development of a Portable Automatic Auditory Response Tester for Hearing Loss Screening (난청감별을 위한 휴대용 자동 청성반응 검사기의 개발)

  • Kim, Soo-Chan
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.2
    • /
    • pp.38-45
    • /
    • 2012
  • If an infant with congenital hearing loss is diagnosed in good time and get proper treatment as soon as possible, treatment effect could be maximized and the social costs could be considerably reduced. For these reasons, the medical equipment to screen hearing impairment objectively is needed. The ABR(auditory brainstem response) is typical diagnostic tools for this purpose but there are drawbacks in sense that it does not have frequency specificity and shows hearing information of usually high frequency band. The ASSR(auditory steady-state response) is excellent in frequency specificity, but the rate of wrong diagnosis is slightly high. In this study, we proposed the system which can measure both the ABR and the ASSR, and can show the objective and quantitative indices(Fsp and F-test). It was designed to allow various tests without hardware modification by minimizing hardware components and by increasing software roles. The objective assessment of the developed system was evaluated by experiments with 10 normal persons.

Impedance-Based Stability Analysis of DC-DC Boost Converters Using Harmonic State Space Model

  • Park, Bumsu;Heryanto, Nur A.;Lee, Dong-Choon
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.7 no.2
    • /
    • pp.255-261
    • /
    • 2021
  • This paper proposes impedance-based stability analysis of DC-DC boost converters, where a harmonic state space (HSS) modeling technique is used. At first, the HSS model of the boost converter is developed. Then, the closed-loop output impedance of the converter is derived in frequency domain using small signal modeling including frequency couplings, where harmonic transfer function (HTF) matrices of the open-loop output impedance, the duty-to-output, and the voltage controller are involved. The frequency response of the output impedance reveals a resonance frequency at low frequency region and frequency couplings at sidebands of switching frequency which agree with the simulation and experimental result.

Anti-inflammatory Effects of Low-frequency Stimulator using Superposition of Alternating Microcurrent Wave in the Animal Models

  • Kim, Yoo-Jeong;Lee, Seong gwang;Go, Shin Jee;An, Suyeon;Kim, Ye eun;Kim, Ye in;Hyun, Kyung-Yae;Cho, Dong Shik;Choi, Go-Eun
    • Biomedical Science Letters
    • /
    • v.27 no.2
    • /
    • pp.99-104
    • /
    • 2021
  • Treatment techniques that affect homeostasis by non-invasive regulation in peripheral organs will advance disease research. Here, we demonstrate a non-invasive method of conditioning within an organ using a low-frequency stimulator superposition of alternating microcurrent wave in stages. It is first applied to the inflammatory response in H3N2-infected sinusitis mice. To check the progress of the treatment, mice were sacrificed every week for 3 weeks, nasal tissue was removed, and the inflammatory response was investigated through H & E staining. The low-frequency stimulation treatment group was found to alleviate the proliferation of epithelial cells and invasion of inflammatory cells compared to the control group as the passage of treatment time. The reduction of inflammatory cytokines in the nasal lavage fluid was observed in H3N2-infected sinusitis mice treated with of low-frequency stimulation using superposition of alternating microcurrent wave compared to H3N2-infected sinusitis mice after 3 weeks. These data demonstrate that low-frequency stimulation device in the form of using alternating current wave superposition on within organs provides a new method to regulate specific physiological functions. Therefore, it is necessary to prove the inhibitory effect of low-frequency stimulation using alternating current wave superposition on inflammatory diseases by various methods through further studies and clinical studies.

A Second-order Harmonic Current Reduction with a Fast Dynamic Response for a Two-stage Single-phase Grid-connected Inverter

  • Jung, Hong-Ju;Kim, Rae-Young
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.1988-1994
    • /
    • 2014
  • In a single-phase grid-connected power system consisting of a DC/DC converter and a DC/AC converter, the current drawn from renewable energy sources has a tendency to be pulsated and contains second-order frequency ripple components, which results in several drawback such as a power harvesting loss and a shortening of the energy source's life. This paper presents a new second-order harmonic current reduction scheme with a fast dc-link voltage loop for two-stage dc-dc-ac grid connected systems. In the frequency domain, an adequate control design is performed based on the small signal transfer function of a two-stage dc-dc-ac converter. To verify the effectiveness of proposed control algorithm, a 1 kW hardware prototype has been built and experimental results are presented.

A Study on Response Improvement of a Proportional Solenoid Actuator (비례제어 솔레노이드 액추에이터의 응답성 향상 연구)

  • Yun, So Nam;Ham, Young Bog;Park, Jung Ho
    • Journal of Drive and Control
    • /
    • v.13 no.3
    • /
    • pp.47-52
    • /
    • 2016
  • This paper presents a control method for the performance improvement of a proportional solenoid actuator using a Pulse Width Modulation (PWM) signal. It is very difficult to obtain excellent response performance from a proportional solenoid actuator using a simple proportional controller with no PWM signal or dither because the mass and structure of a proportional solenoid actuator changes according to the application target, friction force in the proportional solenoid tube, operating force and displacement range. To solve the above problems, first, a controller with a PWM function for experimenting with attraction force characteristics was designed and manufactured. Secondly, an experimental setup for solenoid performance measurement with a force sensor and a displacement sensor was also manufactured. The attraction force characteristics according to the frequency and duty ratio variations of a PWM signal were tested and the relationships among the frequency, duty ratio, plunger mass and friction characteristics were analyzed. Finally, response characteristics improvements for proportional solenoid actuators are discussed.

Shaking table test on seismic response and failure characteristics of ground fissures site during earthquakes

  • Chao, Zhang;Xuzhi, Nie;Zhongming, Xiong;Yuekui, Pang;Xiaolu, Yuan;Yan, Zhuge;Youjun, Xu
    • Geomechanics and Engineering
    • /
    • v.32 no.3
    • /
    • pp.307-319
    • /
    • 2023
  • Ground fissures have a huge effect on the integrity of surface structures. In high-intensity ground fissure regions, however, land resource would be wasted and city building and economic development would be limited if the area avoiding principle was used. In view of this challenge, to reveal the seismic response and seismic failure characteristics of ground fissure sites, a shaking table test on model soil based on a 1:15 scale experiment was carried out. In the test, the spatial distribution characteristics of acceleration response and Arias intensity were obtained for a site exposed to earthquakes with different characteristics. Furthermore, the failure characteristics and damage evolution of the model soil were analyzed. The test results indicated that, with the increase in the earthquake acceleration magnitude, the crack width of the ground fissure enlarged from 0 to 5 mm. The soil of the hanging wall was characterized by earlier cracking and a higher abundance of secondary fissures at 45°. Under strong earthquakes, the model soil, especially the soil near the ground fissure, was severely damaged and exhibited reduced stiffness. As a result, its natural frequency also decreased from 11.41 Hz to 8.05 Hz, whereas the damping ratio increased from 4.8% to 9.1%. Due to the existence of ground fissure, the acceleration was amplified to nearly 0.476 m/s2, as high as 2.38 times of the input acceleration magnitude. The maximum of acceleration and Arias intensity appeared at the fissure zone, which decreased from the main fissure toward both sides, showing hanging wall effects. The seismic intensity, duration and frequency spectrum all had certain effects on the seismic response of the ground fissure site, but their influence degrees were different. The seismic response of the site induced by the seismic wave that had richer low-frequency components and longer duration was larger. The discrepancies of seismic response between the hanging wall and the footwall declined obviously when the magnitude of the earthquake acceleration increased. The research results will be propitious to enhancing the utilizing ratio of the limited landing resource, alleviation of property damages and casualties, and provide a good engineering application foreground.

Identification of Whipping Response using Wavelet Cross-Correlation (웨이블릿 교차상관관계를 이용한 변형체 선박의 휘핑 응답 식별)

  • Kim, Yooil;Kim, Jung-Hyun;Kim, Yonghwan
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.51 no.2
    • /
    • pp.122-129
    • /
    • 2014
  • Identification of the whipping response out of the combined wave-vibration response of a flexible sea going vessel is one of the most interesting research topic from ship designer's point of view. In order to achieve this goal, a novel methodology based on the wavelet cross-correlation technique was proposed in this paper. The cross-correlation of the wavelet power spectrum averaged across the frequency axis was introduced to check the similarity between the combined wave-vibration response and impulse response. The calculated cross-correlation of the wavelet power spectrum was normalized by the auto-correlation of the each spectrum with zero time lag, eventually providing the cross-correlation coefficient that stays between 0 and 1, precisely indicating the existence of the impulse response buried in the combined wave-vibration response. Additionally, the weight function was introduced while calculating the cross-correlation of the two spectrums in order to filter out the signal of lower frequency so that the accuracy of the similarity check becomes as high as possible. The validity of the proposed methodology was checked through the application to the artificially generated ideal combined wave-vibration signal, together with the more realistic signal obtained by running 3D hydroelasticity program WISH-Flex. The correspondence of the identified whipping instances between the results, one from the proposed method and the other from the calculated slamming modal force, was excellent.

Beat Map of King Song-Dok Bell (성덕대왕신종의 맥놀이 지도)

  • Kim, Seock-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.353.1-353
    • /
    • 2002
  • Impulse response of a slightly asymmetric cylindrical shell is derived. Receptance method is applied to obtain the vibration mode and natural frequency of the slightly asymmetric cylindrical shell. Impulse response model is used to identify the vibration beat characteristics of King Song-Dok Bell. The theretical mode is compared and verified by the measured mode of King Song-Dok Bell. (omitted)

  • PDF